197 resultados para photographic chart method
Resumo:
BACKGROUND: Radiation dose exposure is of particular concern in children due to the possible harmful effects of ionizing radiation. The adaptive statistical iterative reconstruction (ASIR) method is a promising new technique that reduces image noise and produces better overall image quality compared with routine-dose contrast-enhanced methods. OBJECTIVE: To assess the benefits of ASIR on the diagnostic image quality in paediatric cardiac CT examinations. MATERIALS AND METHODS: Four paediatric radiologists based at two major hospitals evaluated ten low-dose paediatric cardiac examinations (80 kVp, CTDI(vol) 4.8-7.9 mGy, DLP 37.1-178.9 mGy·cm). The average age of the cohort studied was 2.6 years (range 1 day to 7 years). Acquisitions were performed on a 64-MDCT scanner. All images were reconstructed at various ASIR percentages (0-100%). For each examination, radiologists scored 19 anatomical structures using the relative visual grading analysis method. To estimate the potential for dose reduction, acquisitions were also performed on a Catphan phantom and a paediatric phantom. RESULTS: The best image quality for all clinical images was obtained with 20% and 40% ASIR (p < 0.001) whereas with ASIR above 50%, image quality significantly decreased (p < 0.001). With 100% ASIR, a strong noise-free appearance of the structures reduced image conspicuity. A potential for dose reduction of about 36% is predicted for a 2- to 3-year-old child when using 40% ASIR rather than the standard filtered back-projection method. CONCLUSION: Reconstruction including 20% to 40% ASIR slightly improved the conspicuity of various paediatric cardiac structures in newborns and children with respect to conventional reconstruction (filtered back-projection) alone.
Resumo:
The trabecular bone score (TBS) is a gray-level textural metric that can be extracted from the two-dimensional lumbar spine dual-energy X-ray absorptiometry (DXA) image. TBS is related to bone microarchitecture and provides skeletal information that is not captured from the standard bone mineral density (BMD) measurement. Based on experimental variograms of the projected DXA image, TBS has the potential to discern differences between DXA scans that show similar BMD measurements. An elevated TBS value correlates with better skeletal microstructure; a low TBS value correlates with weaker skeletal microstructure. Lumbar spine TBS has been evaluated in cross-sectional and longitudinal studies. The following conclusions are based upon publications reviewed in this article: 1) TBS gives lower values in postmenopausal women and in men with previous fragility fractures than their nonfractured counterparts; 2) TBS is complementary to data available by lumbar spine DXA measurements; 3) TBS results are lower in women who have sustained a fragility fracture but in whom DXA does not indicate osteoporosis or even osteopenia; 4) TBS predicts fracture risk as well as lumbar spine BMD measurements in postmenopausal women; 5) efficacious therapies for osteoporosis differ in the extent to which they influence the TBS; 6) TBS is associated with fracture risk in individuals with conditions related to reduced bone mass or bone quality. Based on these data, lumbar spine TBS holds promise as an emerging technology that could well become a valuable clinical tool in the diagnosis of osteoporosis and in fracture risk assessment.
Resumo:
Objectives: The aim of this study was to compare specificity and sensitivity of different biological markers that can be used in a forensic field to identify potentially dangerous drivers because of their alcohol habits. Methods: We studied 280 Swiss drivers after driving while under the alcohol influence. 33 were excluded for not having CDT N results, 247 were included (218 men (88%) and 29 women (12%). Mean age was 42,4 (SD:12, min: 20 max: 76). The evaluation of the alcohol consumption concerned the month before the CDT test and was considered as such after the interview: Heavy drinkers (>3 drinks per day): 60 (32.7%), < 3 drinks per day and moderate: 127 (51.4%) 114 (46.5%), abstinent: 60 (24.3%) 51 (21%). Alcohol intake was monitored by structured interviews, self-reported drinking habits and the C-Audit questionnaire as well as information provided by their family and general practitioner. Consumption was quantified in terms of standard drinks, which contain approximately 10 grams of pure alcohol (Ref. WHO). Results: comparison between moderate (less or equal to 3 drinks per day) and excessive drinkers (more than 3 drinks) Marker ROC area 95% CI cut-off sensitivity specificity CDT TIA 0.852 0.786-0917 2.6* 0.93 LR+1.43 0.35 LR-0.192 CDT N latex 0.875 0.821-0.930 2.5* 0.66 LR+ 6.93 0.90 LR- 0.369 Asialo+disialo-tf 0.881 0.826-0.936 1.2* 0.78 LR+4.07 0.80 LR-0.268 1.7° 0.66 LR+8.9 0.93 LR-0.360 GGT 0.659 0.580-0.737 85* 0.37 LR+2.14 0.83 LR-0.764 * cut-off point suggested by the manufacturer ° cut-off point suggested by our laboratory Conclusion: With the cut-off point established by the manufacturer, CDT TIA performed poorly in term of specificity. N latex CDT and CZE CDT were better, especially if a 1.7 cut-off is used with CZE
Resumo:
The sequence profile method (Gribskov M, McLachlan AD, Eisenberg D, 1987, Proc Natl Acad Sci USA 84:4355-4358) is a powerful tool to detect distant relationships between amino acid sequences. A profile is a table of position-specific scores and gap penalties, providing a generalized description of a protein motif, which can be used for sequence alignments and database searches instead of an individual sequence. A sequence profile is derived from a multiple sequence alignment. We have found 2 ways to improve the sensitivity of sequence profiles: (1) Sequence weights: Usage of individual weights for each sequence avoids bias toward closely related sequences. These weights are automatically assigned based on the distance of the sequences using a published procedure (Sibbald PR, Argos P, 1990, J Mol Biol 216:813-818). (2) Amino acid substitution table: In addition to the alignment, the construction of a profile also needs an amino acid substitution table. We have found that in some cases a new table, the BLOSUM45 table (Henikoff S, Henikoff JG, 1992, Proc Natl Acad Sci USA 89:10915-10919), is more sensitive than the original Dayhoff table or the modified Dayhoff table used in the current implementation. Profiles derived by the improved method are more sensitive and selective in a number of cases where previous methods have failed to completely separate true members from false positives.
Resumo:
PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.
Resumo:
Peripheral venous cannulation is the preferred method of inserting central venous silastic catheters in premature infants. The standard techniques are placement of the catheter using a breakaway introducer needle or introduction of the catheter through a cannula. In extremely low birth weight infants (<1000 g) successful cannulation is impeded by the small size of the vessels. After repeated attempts, both procedures can be time-consuming and stressful to the infant. We present a modified insertion technique of the standard 2-French silastic catheter with an increased success rate, thus reducing insertion time, stress to the infant, and costs. The method uses the tip of a 20-gauge cannula as dilator/introducer for the 2-French catheter. This tip is inserted into the vessel with a standard 24-gauge cannula. After successful insertion of the dilator/introducer cannula, the standard 2-French catheter can then be advanced easily.
Resumo:
We present a novel numerical approach for the comprehensive, flexible, and accurate simulation of poro-elastic wave propagation in 2D polar coordinates. An important application of this method and its extensions will be the modeling of complex seismic wave phenomena in fluid-filled boreholes, which represents a major, and as of yet largely unresolved, computational problem in exploration geophysics. In view of this, we consider a numerical mesh, which can be arbitrarily heterogeneous, consisting of two or more concentric rings representing the fluid in the center and the surrounding porous medium. The spatial discretization is based on a Chebyshev expansion in the radial direction and a Fourier expansion in the azimuthal direction and a Runge-Kutta integration scheme for the time evolution. A domain decomposition method is used to match the fluid-solid boundary conditions based on the method of characteristics. This multi-domain approach allows for significant reductions of the number of grid points in the azimuthal direction for the inner grid domain and thus for corresponding increases of the time step and enhancements of computational efficiency. The viability and accuracy of the proposed method has been rigorously tested and verified through comparisons with analytical solutions as well as with the results obtained with a corresponding, previously published, and independently bench-marked solution for 2D Cartesian coordinates. Finally, the proposed numerical solution also satisfies the reciprocity theorem, which indicates that the inherent singularity associated with the origin of the polar coordinate system is adequately handled.
Resumo:
Aims: A rapid and simple HPLC-MS method was developed for the simultaneousdetermination of antidementia drugs, including donepezil, galantamine, rivastigmineand its major metabolite NAP 226 - 90, and memantine, for TherapeuticDrug Monitoring (TDM). In the elderly population treated with antidementiadrugs, the presence of several comorbidities, drug interactions resulting frompolypharmacy, and variations in drug metabolism and elimination, are possiblefactors leading to the observed high interindividual variability in plasma levels.Although evidence for the benefit of TDM for antidementia drugs still remains tobe demonstrated, an individually adapted dosage through TDM might contributeto minimize the risk of adverse reactions and to increase the probability of efficienttherapeutic response. Methods: A solid-phase extraction procedure with amixed-mode cation exchange sorbent was used to isolate the drugs from 0.5 mL ofplasma. The compounds were analyzed on a reverse-phase column with a gradientelution consisting of an ammonium acetate buffer at pH 9.3 and acetonitrile anddetected by mass spectrometry in the single ion monitoring mode. Isotope-labeledinternal standards were used for quantification where possible. The validatedmethod was used to measure the plasma levels of antidementia drugs in 300patients treated with these drugs. Results: The method was validated accordingto international standards of validation, including the assessment of the trueness(-8 - 11 %), the imprecision (repeatability: 1-5%, intermediate imprecision:2 - 9 %), selectivity and matrix effects variability (less than 6 %). Furthermore,short and long-term stability of the analytes in plasma was ascertained. Themethod proved to be robust in the calibrated ranges of 1 - 300 ng/mL for rivastigmineand memantine and 2 - 300 mg/mL for donepezil, galantamine and NAP226 - 90. We recently published a full description of the method (1). We found ahigh interindividual variability in plasma levels of these drugs in a study populationof 300 patients. The plasma level measurements, with some preliminaryclinical and pharmacogenetic results, will be presented. Conclusion: A simpleLC-MS method was developed for plasma level determination of antidementiadrugs which was successfully used in a clinical study with 300 patients.
Resumo:
The pericentric inversion on chromosome 16 [inv(16)(p13q22)] and related t(16;16)(p13;q22) are recurrent aberrations associated with acute myeloid leukemia (AML) M4 Eo. Both abberations result in a fusion of the core binding factor beta (CBFB) and smooth muscle myosin heavy chain gene (MYH11). A selected genomic 6.9-kb BamHl probe detects MYH11 DNA rearrangements in 18 of 19 inv(16)/t(16;16) patients tested using HindIII digested DNA. The rearranged fragments were not detectable after remission in two cases tested, while they were present after relapse in one of these two cases tested.
Resumo:
Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility.
Resumo:
In this paper, an extension of the multi-scale finite-volume (MSFV) method is devised, which allows to Simulate flow and transport in reservoirs with complex well configurations. The new framework fits nicely into the data Structure of the original MSFV method,and has the important property that large patches covering the whole well are not required. For each well. an additional degree of freedom is introduced. While the treatment of pressure-constraint wells is trivial (the well-bore reference pressure is explicitly specified), additional equations have to be solved to obtain the unknown well-bore pressure of rate-constraint wells. Numerical Simulations of test cases with multiple complex wells demonstrate the ability of the new algorithm to capture the interference between the various wells and the reservoir accurately. (c) 2008 Elsevier Inc. All rights reserved.
Resumo:
RESUME Dès le printemps 2004, la construction d'une 2ème ligne de métro est entreprise dans la ville de Lausanne en Suisse. En reliant Ouchy, au bord du lac Léman (alt. 373 m) à Epalinges (alt. 711 m), le nouveau métro "M2" traversera dès 2008 l'agglomération lausannoise du Sud au Nord sur une distance de 6 km. Depuis l'avant-projet, en 1999, une grande quantité de données géologiques a été récolté et de nombreux forages exécutés sur le site. Ceci nous a donné une occasion unique d'entreprendre une étude de microgravimétrique urbaine de détail. Le mode de creusement du tunnel dépend fortement des matériaux à excaver et il est classiquement du domaine du géologue, avec ses connaissances de la géologie régionale et de la stratigraphie des forages, de fournir à l'ingénieur un modèle géologique. Ce modèle indiquera dans ce cas l'épaisseur des terrains meubles qui recouvrent le soubassement rocheux. La représentativité spatiale d'une information très localisée, comme celle d'un forage, est d'autant plus compliquée que le détail recherché est petit. C'est à ce moment là que la prospection géophysique, plus spécialement gravimétrique, peut apporter des informations complémentaires déterminantes pour régionaliser les données ponctuelles des forages. La microgravimétrie en milieu urbain implique de corriger avec soin les perturbations gravifiques sur la mesure de la pesanteur dues aux effets de la topographie, des bâtiments et des caves afin d'isoler l'effet gravifique dû exclusivement à l'épaisseur du remplissage des terrains meubles. Tenant compte de l'intensité des corrections topographiques en milieu urbain, nous avons donné une grande importance aux sous-sols, leurs effets gravifiques pouvant atteindre l'ordre du dixième de mGal. Nous avons donc intégré ces corrections celle de topographie et traité les effets des bâtiments de manière indépendante. Nous avons inclus dans le modèle numérique de terrain (MNT) la chaussée et les sous-sols afin de construire un modèle numérique de terrain urbain. Nous utiliserons un nouvel acronyme « MNTU »pour décrire ce modèle. Nous proposons d'établir des cartes de corrections topographiques préalables, basées sur les données à disposition fournies par le cadastre en faisant des hypothèses sur la profondeur des sous-sols et la hauteur des bâtiments. Les deux zones de test choisies sont caractéristiques des différents types d'urbanisation présente à Lausanne et se révèlent par conséquent très intéressantes pour élaborer une méthodologie globale de la microgravimétrie urbaine. Le but était d'évaluer l'épaisseur du remplissage morainique sur un fond rocheux molassique se situant à une profondeur variable de quelques mètres à une trentaine de mètres et d'en établir une coupe dans l'axe du futur tracé du métro. Les résultats des modélisations se sont révélés très convaincants en détectant des zones qui diffèrent sensiblement du modèle géologique d'avant projet. Nous avons également démontré que l'application de cette méthode géophysique, non destructive, est à même de limiter le nombre de sondages mécaniques lors de l'avant-projet et du projet définitif, ce qui peut limiter à la fois les coûts et le dérangement engendré par ces travaux de surface. L'adaptabilité de la technique gravimétrique permet d'intervenir dans toutes les différentes phases d'un projet de génie civil comme celui de la construction d'un métro en souterrain. KURZFASSUNG Seit dem Frühling 2004 ist in der Stadt Lausanne (Schweiz) die neue U-Bahn "M2" in Konstruktion. Diese soll auf 6 km Länge die Lausanner Agglomeration von Süd nach Nord durchqueren. Die dem Projekt zu Grunde liegende technische Planung sieht vor, daß die Bahnlinie hauptsächlich in der Molasse angesiedelt sein wird. Seit dem Vorentwurf (1999) ist eine große Anzahl geologischer Angaben gesammelt worden. Daraus ergab sich die einmalige Gelegenheit, die Informationen aus den damit verbundenen zahlreichen Bohrungen zu einer detaillierten mikrogravimetrischen Studie der Stadt Lausanne zu erweitern und zu vervollständigen. Das Ziel bestand darin, die Mächtigkeit der die Molasseüberdeckenden Moräneablagerung abzuschätzen, um eine entsprechendes geologisches Profile entlang der künftigen Bahnlinie zu erstellen. Weiterhin sollte gezeigt werden, daß die Anwendung dieser nicht-invasiven geophysikalischen Methode es ermöglicht, die Anzahl der benötigten Bohrungen sowohl in der Pilotphase wie auch im endgültigen Projekt zu reduzieren, was zu wesentlichen finanziellen Einsparungen in der Ausführung des Werkes beitragen würde. Die beiden in dieser Studie bearbeiteten Testzonen befinden sich im Nordteil und im Stadtzentrum von Lausanne und sind durch eine unterschiedliche Urbanisierung charakterisiert. Das anstehende Gestein liegt in verschiedenen Tiefen: von einigen Metern bis zu etwa dreißig Metern. Diese Zonen weisen alle Schwierigkeiten einer urbanen Bebauung mit hoher Verkehrsdichte auf und waren daher massgebend bei der Ausarbeitung einer globalen mikrogravimetrischen Methodologie für die Stadt Lausanne. Die so entwickelte Technik ermöglicht, die störenden Auswirkungen der Topographie, der Gebäude, der Keller und der Öffentlichen Infrastrukturen sorgfältig zu korrigieren, um so die ausschließlich auf die Mächtigkeit des Lockergesteins zurückzuführenden Effekte zu isolieren. In Bezug auf die Intensität der Auswirkungen der topographischen Korrekturen im Stadtgebiet wurde den Untergeschossen eine besonders grosse Bedeutung zugemessen da die entsprechenden Schwerkrafteffekte eine Grösse von rund einem Zehntel mGal erreichen können. Wir schlagen deshalb vor, vorläufige Karten der topographischen Korrekturen zu erstellen. Diese Korrekturen basieren auf den uns vom Katasterplan gelieferten Daten und einigen Hypothesen bezüglich der Tiefe der Untergeschosse und der Höhe der Gebäude. Die Verfügbarkeit einer derartigen Karte vor der eigentlichen gravimetrischen Messkampagne würde uns erlauben, die Position der Meßstationen besser zu wählen. Wir sahen zudem, daß ein entsprechenden a priori Filter benutzt werden kann, wenn die Form und die Intensität der Anomalie offensichtlich dem entsprechenden Gebäude zugeordnet werden können. Diese Strategie muß jedoch mit Vorsicht angewandt werden, denn falls weitere Anomalien dazukommen, können bedeutende Verschiebungen durch Übèrlagerungen der Schwerewirkung verschiedener Strukturen entstehen. Die Ergebnisse der Modellierung haben sich als sehr überzeugend erwiesen, da sie im Voraus unbekannte sensible Zonen korrekt identifiziert haben. Die Anwendbarkeit der in dieser Arbeit entwickelten gravimetrischen Technik ermöglicht es, während allen Phasen eines Grossbauprojekts, wie zum Beispiel bei der Konstruktion einer unterirdischen U-Bahn, einzugreifen. ABSTRACT Since Spring of 2004 a new metro line has been under construction in the city of Lausanne in Switzerland. The new line, the M2, will be 6 km long and will traverse the city from south to north. The civil engineering project determined that the line would be located primarily in the Molasse. Since the preparatory project in 1999, a great quantity of geological data has been collected, and the many drillings made on the site have proved to be a unique opportunity to undertake a study of urban microgravimetry. The goal was to evaluate the thickness of the morainic filling over the molassic bedrock, and to establish a section along the axis of the future line. It then had to be shown that the application of this nondestructive geophysical method could reduce the number of mechanical surveys required both for a preparatory and a definitive project, which would lead to real savings in the realization of a civil engineering project. The two test zones chosen, one in the northern part of the city and one in the city centre, are characterised by various types of urbanisation. Bedrock is at a depth varying from a few metres to about thirty metres. These zones well exemplify the various difficulties encountered in an urban environment and are therefore very interesting for the development of an overall methodology of urban microgravimetry. Microgravimetry in an urban environment requires careful corrections for gravific disturbances due to the effects of topography, buildings, cellars, and the infrastructure of distribution networks, in order to isolate the gravific effect due exclusively to the thickness of loose soil filling. Bearing in mind the intensity of the topographic corrections in an urban environment, we gave particular importance to basements. Their gravific effects can reach the order of one tenth of one meal, and can influence above all the precision of the Bouguer anomaly. We propose to establish preliminary topographic correction charts based on data provided to us by the land register, by making assumptions on the depths of basements and the heights of buildings. Availability of this chart previous to a gravimetry campaign would enable us to choose optimum measuring sites. We have also seen that an a priori filter can be used when the form and the intensity of the anomaly correspond visually to the corresponding building. This strategy must be used with caution because if other anomalies are to be associated, important shifts can be generated by the superposition of the effects of different structures. The results of the model have proved to be very convincing in detecting previously unknown sensitive zones. The adaptability of the gravimetry technique allows for application in all phases of a civil engineering project such as the construction of an underground metro line. RIASSUNTO Dalla primavera 2004 una nuova linea metropolitana é in costruzione nella città di Losanna in Svizzera. La nuova metropolitana "M2" traverserà per la lunghezza di 6 km il centro urbano di Losanna da sud a nord. II progetto d'ingegneria civile prevedeva un tracciato situato essenzialmente nel fondo roccioso arenaceo terziario (molassa). Dalla redazione del progetto preliminare, avvenuta nel 1999, una grande quantità di dati geologici sono stati raccolti e sono stati eseguiti numerosi sondaggi. Questo sì é presentato come un'occasione unica per mettere a punto uno studio microgravimetrico in ambiente urbano con lo scopo di valutare lo spessore dei terreni sciolti di origine glaciale che ricoprono il fondo roccioso di molassa e di mettere in evidenza come l'applicazione di questo metodo geofisico non distruttivo possa limitare il numero di sondaggi meccanici nella fase di progetto preliminare ed esecutivo con conseguente reale risparmio economico nella realizzazione di una tale opera. Le due zone di test sono situate una nella zona nord e la seconda nel centro storico di Losanna e sono caratterizzate da stili architettonici differenti. II fondo roccioso é situato ad una profondità variabile da qualche metro ad una trentina. Queste due zone sembrano ben rappresentare tutte le difficoltà di un ambiente urbano e ben si prestano per elaborare una metodologia globale per la microgravimetria in ambiente urbano. L'applicazione di questa tecnica nell'ambiente suddetto implica la correzione attenta delle perturbazioni sulla misura dell'accelerazione gravitazionale, causate dalla topografia, gli edifici, le cantine e le infrastrutture dei sottoservizi, per ben isolare il segnale esclusivamente causato dallo spessore dei terreni sciolti. Tenuto conto, dell'intensità delle correzioni topografiche, abbiamo dato grande importanza alle cantine, poiché il loro effetto sulle misure può raggiungere il decimo di mGal. Proponiamo quindi di redigere una carta delle correzioni topografiche preliminare all'acquisizione, facendo delle ipotesi sulla profondità delle cantine e sull'altezza degli edifici, sulla base delle planimetrie catastali. L'analisi di questa carta permetterà di scegliere le posizioni più adatte per le stazioni gravimetriche. Abbiamo anche osservato che un filtro a priori, qualora la forma e l'intensità dell'anomalia fosse facilmente riconducibile in maniera visuale ad un edificio, possa essere efficace. Tuttavia questa strategia deve essere utilizzata con precauzione, poiché può introdurre uno scarto, qualora più anomalie, dovute a differenti strutture, si sovrappongano. I risultati delle modellizzazioni si sono rivelati convincenti, evidenziando zone sensibili non conosciute preventivamente. L'adattabilità della tecnica gravimetrica ha mostrato di poter intervenire in differenti fasi di un progetto di ingegneria civile, quale è quella di un'opera in sotterraneo.