181 resultados para mitral valve replacement
Resumo:
AIMS: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. METHODS AND RESULTS: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. CONCLUSION: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.
Resumo:
BACKGROUND: We analysed 5-year treatment with agalsidase alfa enzyme replacement therapy in patients with Fabry's disease who were enrolled in the Fabry Outcome Survey observational database (FOS). METHODS: Baseline and 5-year data were available for up to 181 adults (126 men) in FOS. Serial data for cardiac mass and function, renal function, pain, and quality of life were assessed. Safety and sensitivity analyses were done in patients with baseline and at least one relevant follow-up measurement during the 5 years (n=555 and n=475, respectively). FINDINGS: In patients with baseline cardiac hypertrophy, treatment resulted in a sustained reduction in left ventricular mass (LVM) index after 5 years (from 71.4 [SD 22.5] g/m(2.7) to 64.1 [18.7] g/m(2.7), p=0.0111) and a significant increase in midwall fractional shortening (MFS) from 14.3% (2.3) to 16.0% (3.8) after 3 years (p=0.02). In patients without baseline hypertrophy, LVM index and MFS remained stable. Mean yearly fall in estimated glomerular filtration rate versus baseline after 5 years of enzyme replacement therapy was -3.17 mL/min per 1.73 m(2) for men and -0.89 mL/min per 1.73 m(2) for women. Average pain, measured by Brief Pain Inventory score, improved significantly, from 3.7 (2.3) at baseline to 2.5 (2.4) after 5 years (p=0.0023). Quality of life, measured by deviation scores from normal EuroQol values, improved significantly, from -0.24 (0.3) at baseline to -0.17 (0.3) after 5 years (p=0.0483). Findings were confirmed by sensitivity analysis. No unexpected safety concerns were identified. INTERPRETATION: By comparison with historical natural history data for patients with Fabry's disease who were not treated with enzyme replacement therapy, long-term treatment with agalsidase alfa leads to substantial and sustained clinical benefits. FUNDING: Shire Human Genetic Therapies AB.
Resumo:
INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.
Resumo:
The treatment of hip osteoarthritis with total hip arthroplasty has continuously evolved since it was first introduced in the sixties. The problem of aseptic loosening of the cemented prostheses, mainly in young active patients, has stimulated two different types of research: on one side the improvement of cementing techniques and on the other side the development of cementless osteoinegrable implants. We discuss the problems of these cementless hip prostheses. Recently published anatomic and biomechanic studies have led to the development of personalized custom femoral stems for each patient. The conception technique and first clinical results are described.
Resumo:
This study aimed to investigate the influence of ankle osteoarthritis (AOA) treatments, i.e., ankle arthrodesis (AA) and total ankle replacement (TAR), on the kinematics of multi-segment foot and ankle complex during relatively long-distance gait. Forty-five subjects in four groups (AOA, AA, TAR, and control) were equipped with a wearable system consisting of inertial sensors installed on the tibia, calcaneus, and medial metatarsals. The subjects walked 50-m twice while the system measured the kinematic parameters of their multi-segment foot: the range of motion of joints between tibia, calcaneus, and medial metatarsals in three anatomical planes, and the peaks of angular velocity of these segments in the sagittal plane. These parameters were then compared among the four groups. It was observed that the range of motion and peak of angular velocities generally improved after TAR and were similar to the control subjects. However, unlike AOA and TAR, AA imposed impairments in the range of motion in the coronal plane for both the tibia-calcaneus and tibia-metatarsals joints. In general, the kinematic parameters showed significant correlation with established clinical scales (FFI and AOFAS), which shows their convergent validity. Based on the kinematic parameters of multi-segment foot during 50-m gait, this study showed significant improvements in foot mobility after TAR, but several significant impairments remained after AA.
Resumo:
Lymphatic valves are essential for efficient lymphatic transport, but the mechanisms of early lymphatic-valve morphogenesis and the role of biomechanical forces are not well understood. We found that the transcription factors PROX1 and FOXC2, highly expressed from the onset of valve formation, mediate segregation of lymphatic-valve-forming cells and cell mechanosensory responses to shear stress in vitro. Mechanistically, PROX1, FOXC2, and flow coordinately control expression of the gap junction protein connexin37 and activation of calcineurin/NFAT signaling. Connexin37 and calcineurin are required for the assembly and delimitation of lymphatic valve territory during development and for its postnatal maintenance. We propose a model in which regionally increased levels/activation states of transcription factors cooperate with mechanotransduction to induce a discrete cell-signaling pattern and morphogenetic event, such as formation of lymphatic valves. Our results also provide molecular insights into the role of endothelial cell identity in the regulation of vascular mechanotransduction.
Resumo:
Introduction and Aims: Fabry disease is an X-linked lysosomal storage disorder caused by absence or deficient activity of the lysosomal enzyme alpha-galactosidase A. Renal manifestations occur early in life in a significant proportion of children, in many women and in almost all men with Fabry disease. These manifestations ultimately progress to end-stage renal disease in nearly all males and in some female patients. Data on kidney transplantation in patients with Fabry disease who are receiving enzyme replacement therapy (ERT), however, are scarce. Methods: We examined the clinical characteristics of kidney transplant recipients (KTRs) in the Fabry Outcome Survey (FOS) - a European database of patients with Fabry disease that was established to monitor the safety and outcome of ERT. Results: Of the 752 patients enrolled in FOS up to October 2005, 34 (4.5%) were reported to be KTRs. The mean age of these 32 male and 2 female patients was 45 ± 9 years, the median time since the transplant was 9 years, the median estimated glomerular filtration rate (eGFR) was 46 mL/min/1.73 m2 and the median level of proteinuria was 180 mg/24 hours. ERT was well tolerated, with mild infusion-related reactions reported in only one patient. Amongst these patients, 53% were reported to have hypertension, 71% left ventricular hypertrophy, 27% cardiac valve disease and 27% arrhythmia. A total of 23 (68%) of the patients (1 female, 22 males) were receiving ERT with agalsidase alfa (Replagal; Shire Human Genetic Therapies, UK), with a median duration of treatment of 2.5 years. There were no differences in age or time since transplantation between treated and untreated patients. The median eGFRs were 46 and 49 mL/min/1.73 m2 and the median levels of proteinuria were 200 and 160 mg/24 hours, respectively. Conclusions: KTRs represent a significant minority of individuals enrolled in a large international registry of patients with Fabry disease (FOS). Approximately two-thirds of KTRs with Fabry disease enrolled in FOS receive ERT with agalsidase alfa, which is well tolerated. Comparison of treated and untreated patients has the potential to examine effects of ERT on the progression of renal and cardiovascular disease.
Resumo:
METHODS: Twenty-two patients receiving (R)-methadone maintenance treatment were switched to a double dose of (R,S)-methadone: blood samples were collected before and after the change, and the concentrations of the enantiomers were measured. In the second period, during racemic methadone treatment, important interindividual variability in the stereoselective disposition of the enantiomers of methadone was measured, with (R)/(S) ratios ranging from 0.63 to 2.40. This point should be taken into account particularly with respect to therapeutic drug monitoring of racemic methadone. RESULTS: A significant decrease P < 0.005 in the mean serum concentration/dose ratios of the active (R)-enantiomer before and after the change was measured (mean 3.97 and 3.33). CONCLUSION: Although of small amplitude (16%), this decrease confirms previously described adaptive changes in methadone pharmacokinetics during racemic methadone maintenance treatment and may necessitate, in some patients, a dose adjustment.
Resumo:
Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.