206 resultados para component classification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new radiolarian order - Archaeospicularia - is proposed for some Lower Paleozoic radiolarians previously considered to belong to Spumellaria and to Collodaria. It is characterized by a globular shell made of several spicules which can be free, interlocked, or fused to formed a latticed wall. The present paper gives the definition of this order and proposes a first classification. It is supposed that the Archaeospicularia represents the oldest radiolarian group and that in the Lower Paleozoic it gave rise to the orders Entactinaria, Albaillellaria, and probably Spumellaria by the reduction of the number of initial spicules. The origin of this order and its relationships with other groups of organisms with siliceous skeletons are also briefly discussed. (C) 2000 Academie des sciences / Editions scientifiques et medicales Elsevier SAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Performing total knee replacement, accurate alignment and neutral rotation of the femoral component are widely believed to be crucial for the ultimate success. Contrary to absolute bone referenced alignment, using a ligament balancing technique does not automatically rotate the femoral component parallel to the transepicondylar axis. In this context we established the hypothesis that rotational alignment of the femoral component parallel to the transepicondylar axis (0° ± 3°) results in better outcome than alignment outside of this range. METHODS: We analysed 204 primary cemented mobile bearing total knee replacements five years postoperatively. Femoral component rotation was measured on axial radiographs using the condylar twist angle (CTA). Knee society score, range of motion as well as subjective rating documented outcome. RESULTS: In 96 knees the femoral component rotation was within the range 0 ± 3° (neutral rotation group), and in 108 knees the five-year postoperative rotational alignment of the femoral component was outside of this range (outlier group). Postoperative CTA showed a mean of 2.8° (±3.4°) internal rotation (IR) with a range between 6° external rotation (ER) and 15° IR (CI 95). No difference with regard to subjective and objective outcome could be detected. CONCLUSION: The present work shows that there is a large given natural variability in optimal rotational orientation, in this study between 6° ER and 15° IR, with numerous co-factors determining correct positioning of the femoral component. Further studies substantiating pre- and postoperative determinants are required to complete the understanding of resulting biomechanics in primary TKA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glioblastoma (GBM) is a morphologically heterogeneous tumor type with a median survival of only 15 months in clinical trial populations. However, survival varies greatly among patients. As part of a central pathology review, we addressed the question if patients with GBM displaying distinct morphologic features respond differently to combined chemo-radiotherapy with temozolomide. Morphologic features were systematically recorded for 360 cases with particular focus on the presence of an oligodendroglioma-like component and respective correlations with outcome and relevant molecular markers. GBM with an oligodendroglioma-like component (GBM-O) represented 15% of all confirmed GBM (52/339) and was not associated with a more favorable outcome. GBM-O encompassed a pathogenetically heterogeneous group, significantly enriched for IDH1 mutations (19 vs. 3%, p = 0.003) and EGFR amplifications (71 vs. 48%, p = 0.04) compared with other GBM, while co-deletion of 1p/19q was found in only one case and the MGMT methylation frequency was alike (47 vs. 46%). Expression profiles classified most of the GBM-O into two subtypes, 36% (5/14 evaluable) as proneural and 43% as classical GBM. The detection of pseudo-palisading necrosis (PPN) was associated with benefit from chemotherapy (p = 0.0002), while no such effect was present in the absence of PPN (p = 0.86). In the adjusted interaction model including clinical prognostic factors and MGMT status, PPN was borderline nonsignificant (p = 0.063). Taken together, recognition of an oligodendroglioma-like component in an otherwise classic GBM identifies a pathogenetically mixed group without prognostic significance. However, the presence of PPN may indicate biological features of clinical relevance for further improvement of therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anorectal malformations (ARMs) are a complex group of congenital anomalies involving the distal anus and rectum, as well as the urinary and genital tracts in a significant number of cases. Most ARMs result from abnormal development of the urorectal septum in early fetal life. In most cases, the anus is not perforated and the distal enteric component ends blindly (atresia) or as a fistula into the urinary tract, genital tract, or perineum. ARMs are also present in a great number of syndromes and associations of congenital anomalies. The classification of ARMs is mainly based on the position of the rectal pouch relative to the puborectal sling, the presence or absence of fistulas, and the types and locations of the fistulas. All of this information is crucial in determining the most appropriate surgical approach for each case. Imaging studies play a key role in evaluation and classification of ARMs. In neonates, clinical and radiologic examinations in the first 3 days of life help determine the type of ARM and the need for early colostomy. In older children, preoperative pelvic magnetic resonance imaging is the most efficient diagnostic method for evaluating the size, morphology, and grade of development of the sphincteric musculature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first AO comprehensive pediatric long-bone fracture classification system has been proposed following a structured path of development and validation with experienced pediatric surgeons. A Web-based multicenter agreement study involving 70 surgeons in 15 clinics and 5 countries was conducted to assess the reliability and accuracy of this classification when used by a wide range of surgeons with various levels of experience. Training was provided at each clinic before the session. Using the Internet, participants could log in at any time and classify 275 supracondylar, radius, and tibia fractures at their own pace. The fracture diagnosis was made following the hierarchy of the classification system using both clinical terminology and codes. kappa coefficients for the single-surgeon diagnosis of epiphyseal, metaphyseal, or diaphyseal fracture type were 0.66, 0.80, and 0.91, respectively. Median accuracy estimates for each bone and type were all greater than 80%. Depending on their experience and specialization, surgeons greatly varied in their ability to classify fractures. Pediatric training and at least 2 years of experience were associated with significant improvement in reliability and accuracy. Kappa coefficients for diagnosis of specific child patterns were 0.51, 0.63, and 0.48 for epiphyseal, metaphyseal, and diaphyseal fractures, respectively. Identified reasons for coding discrepancies were related to different understandings of terminology and definitions, as well as poor quality radiographic images. Results supported some minor adjustments in the coding of fracture type and child patterns. This classification system received wide acceptance and support among the surgeons involved. As long as appropriate training could be performed, the system classification was reliable, especially among surgeons with a minimum of 2 years of clinical experience. We encourage broad-based consultation between surgeons' international societies and the use of this classification system in the context of clinical practice as well as prospectively for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the diagnostic efficiency of plain film and spiral CT examinations with 3D reconstructions of 42 tibial plateau fractures and to assess the accuracy of these two techniques in the pre-operative surgical plan in 22 cases. Forty-two tibial plateau fractures were examined with plain film (anteroposterior, lateral, two obliques) and spiral CT with surface-shaded-display 3D reconstructions. The Swiss AO-ASIF classification system of bone fracture from Muller was used. In 22 cases the surgical plans and the sequence of reconstruction of the fragments were prospectively determined with both techniques, successively, and then correlated with the surgical reports and post-operative plain film. The fractures were underestimated with plain film in 18 of 42 cases (43%). Due to the spiral CT 3D reconstructions, and precise pre-operative information, the surgical plans based on plain film were modified and adjusted in 13 cases among 22 (59%). Spiral CT 3D reconstructions give a better and more accurate demonstration of the tibial plateau fracture and allows a more precise pre-operative surgical plan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comme la classification de Savary-Miller dont elle adopte l'essentiel, la classification de l'oesophagite par refluxen 5 types de Savary-Monnier repose sur une analyse rigoureuse et précise des lésions endoscopiques. Ses principales qualités sont d'être simple, complète, logique et souple. Son impact sur la pratique est certain puisqu'elle a une excellente valeur pronostique et qu'elle permet de choisir la bonne stratégie thérapeutique. De plus, en isolant les cicatrices cylindriques (seules précancéroses à surveiller à long terme) elle permet de les utiliser pour préciser la topographie des oesophagites de reflux.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The InterPro database (http://www.ebi.ac.uk/interpro/) is a freely available resource that can be used to classify sequences into protein families and to predict the presence of important domains and sites. Central to the InterPro database are predictive models, known as signatures, from a range of different protein family databases that have different biological focuses and use different methodological approaches to classify protein families and domains. InterPro integrates these signatures, capitalizing on the respective strengths of the individual databases, to produce a powerful protein classification resource. Here, we report on the status of InterPro as it enters its 15th year of operation, and give an overview of new developments with the database and its associated Web interfaces and software. In particular, the new domain architecture search tool is described and the process of mapping of Gene Ontology terms to InterPro is outlined. We also discuss the challenges faced by the resource given the explosive growth in sequence data in recent years. InterPro (version 48.0) contains 36 766 member database signatures integrated into 26 238 InterPro entries, an increase of over 3993 entries (5081 signatures), since 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of type-2 fuzzy sets for managing high levels of uncertainty in the subjective knowledge of experts or of numerical information has focused on control and pattern classification systems in recent years. One of the main challenges in designing a type-2 fuzzy logic system is how to estimate the parameters of type-2 fuzzy membership function (T2MF) and the Footprint of Uncertainty (FOU) from imperfect and noisy datasets. This paper presents an automatic approach for learning and tuning Gaussian interval type-2 membership functions (IT2MFs) with application to multi-dimensional pattern classification problems. T2MFs and their FOUs are tuned according to the uncertainties in the training dataset by a combination of genetic algorithm (GA) and crossvalidation techniques. In our GA-based approach, the structure of the chromosome has fewer genes than other GA methods and chromosome initialization is more precise. The proposed approach addresses the application of the interval type-2 fuzzy logic system (IT2FLS) for the problem of nodule classification in a lung Computer Aided Detection (CAD) system. The designed IT2FLS is compared with its type-1 fuzzy logic system (T1FLS) counterpart. The results demonstrate that the IT2FLS outperforms the T1FLS by more than 30% in terms of classification accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: MCI was recently subdivided into sd-aMCI, sd-fMCI, and md-aMCI. The current investigation aimed to discriminate between MCI subtypes by using DTI. MATERIALS AND METHODS: Sixty-six prospective participants were included: 18 with sd-aMCI, 13 with sd-fMCI, and 35 with md-aMCI. Statistics included group comparisons using TBSS and individual classification using SVMs. RESULTS: The group-level analysis revealed a decrease in FA in md-aMCI versus sd-aMCI in an extensive bilateral, right-dominant network, and a more pronounced reduction of FA in md-aMCI compared with sd-fMCI in right inferior fronto-occipital fasciculus and inferior longitudinal fasciculus. The comparison between sd-fMCI and sd-aMCI, as well as the analysis of the other diffusion parameters, yielded no significant group differences. The individual-level SVM analysis provided discrimination between the MCI subtypes with accuracies around 97%. The major limitation is the relatively small number of cases of MCI. CONCLUSIONS: Our data show that, at the group level, the md-aMCI subgroup has the most pronounced damage in white matter integrity. Individually, SVM analysis of white matter FA provided highly accurate classification of MCI subtypes.