159 resultados para aorta pressoreceptor


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Apoptotic arterial wall vascular smooth muscle cell death is known to contribute to plaque vulnerability and rupture. Novel apoptotic markers like apolipoprotein C-I have been implicated in apoptotic human vascular smooth muscle cell death via recruiting a neutral sphingomyelinase (N-SMase)-ceramide pathway. In vivo relevance of these observations in an animal model of plaque rupture has not been shown. METHODS AND RESULTS: Using Watanabe rabbits, we investigated three different groups (group 1, three normal Watanabe rabbits; group 2, six Watanabe rabbits fed with high cholesterol diet for 3 months; group 3, five Watanabe rabbits with similar diet but additional endothelial denudation). We followed progression of atherosclerosis to pharmacologically induced plaque rupture non-invasively using novel 3D magnetic resonance Fast-Field-Echo angiography (TR=7.2, TE=3.6 ms, matrix=512 x 512) and Fast-Spin-Echo vessel wall imaging methods (TR=3 heart beats, TE=10.5 ms, matrix=304 x 304) on 1.5 T MRI. MRI provided excellent image quality with good MRI versus histology vessel wall thickness correlation (r=0.8). In six animals of group 2/3 MRI detected neo-intimal dissection in the abdominal aorta which was accompanied by immuno-histochemical demonstration of concomitant aforementioned novel apoptotic markers, previously implicated in the apoptotic smooth muscle cell death in vitro. CONCLUSIONS: Our studies suggest a potential role for the signal transduction pathway involving apolipoprotein C-I for in vivo apoptosis and atherosclerotic plaque rupture visualized by MRI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the case of a young man with compression of both renal arteries by the crura of the diaphragm. Correct diagnosis of renal artery entrapment is difficult but crucial. The investigations rely on an high index of suspicion and include Doppler ultrasound and spiral computed tomography angiography, which permits visualization of the diaphragm and its relationships with the aorta. This pathology, unlike common renal artery stenoses, requires surgical decompression and sometimes aortorenal bypass graft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Due to patency of the arterial duct and the parallel circulation during the fetal life, coarctation remains a difficult diagnosis prenatally and even shortly after birth. Fisrtly, our study aimed to assess accuracy of a new cardiographie index based on morphologie measurements of the distal aortic arch, the Carotid-Subclavian Artery Index (CSA Index), the ratio of the distal transverse aortic arch diameter to the distance between the left carotid artery and the left subclavian artery, in detecting coarctation in newborns, infants and children, independently of other cardiac lesions. Secondly, to assess the additive value of another morphologie index in predicting coarctation, the 1/0 ratio, the ratio of isthmus to descending aorta diameter. Methods: It is a retrospective cohort study in a tertiary care children's hospital. Offline echocardiographic measurements of great vessels and aortic arch dimensions were done in 69 patients with coarctation. We calculate their CSA index, and their 1/0 ratio. Values of CSA Index and 1/0 ratio from coarctation group were compared with those from a normal local control population. Results: 69 echocardiograms from patients with coarctation were analysed. Compared with controls, patients with coarctation had a significantly lower CSA index (0.88 ±0.49 vs 2.65 ±0.82, p <0.0001) and 1/0 ratio. The same significant difference was observed, independently of age and other associated defects, even complex ones. CSA Index confirmed its good sensitivity and specificity (99% and 96% respectively). This was not improved by adding the I/D ratio. Conclusions: An abnormal CSA index is highly suggestive of coarctation independently of age, of the presence of a patent ductus arteriosus or of other cardiac defects. The addition of another anatomie index, the I/D ratio, was not helpful in our study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hybrid treatment of aortic aneurysms is indicated in patients having the ostia of supra aortic or visceral branches taken in to the aneurysm. Indeed, these lesions are not eligible for classic endovascular treatment because the existing endoprostheses cannot provide perfusion of the side branches without inducing major endoleaks. The surgical technique consists of 2 steps: firstly, a by-pass between normal aorta and the major aortic branches involved in the aneurysm is performed to guarantee the perfusion of the organs such as brain, bowel, and after endoprosthesis deployment. Secondly, the endoprosthesis is deployed using the classical technique to isolate the aneurysm. The hybrid approach provides safe and reliable treatment of complex aortic aneurysms with mortality and morbidity rate far below the classical open surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intra-aortic balloon pump (IABP) is the most frequently used mechanical circulatory support. Repeated trauma on the aortic wall has been reported as a cause of balloon perforation by endothelial denudation of atheromatous plaque. This study analyses the effect of IABP on the endothelium of the calf aorta. In 12 calves (mean weight: 72 +/- 6 kg) an IABP was inserted by femoral route and left during 6 hours on internal mode with a frequency of 80 cycles/min. The animals were sacrificed after the procedure (n = 4), at postoperative day (POD) 7 (n = 4), and at POD 14 (n = 4). In the aorta facing the balloon, nine transmural samples were taken proximally (n = 3), at mid height (n = 3) and distally (n = 3), for histological analysis of the percentage of aortic surface covered with endothelium. The percentage of aortic surface covered with endothelium at POD 0, 7 and 14 was proximally: 72.5 +/- 27.5%, 83.7 +/- 16.9% and 93.3 +/- 8.9% respectively; at mid-height: 50.8 +/- 30.7%, 65 +/- 25% and 95 +/- 5%; and distally: 31.4 +/- 20.1%, 48.3 +/- 34.4% and 85 +/- 10%. A large portion of the aortic endothelium is abraded after 6 hours of IAB pumping. This effect is more important at the distal level of the aorta. After two weeks, most of the endothelium has regenerated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Interventional catheterization is being increasingly used for relief of residual lesions in congenital heart disease. Exact anatomical imaging is crucial in the planning of an intervention. This can be provided non-invasively and without radiation by contrast-enhanced MR angiography (CEMRA). Aim: To evaluate the accuracy of the measurements of the vessels obtained by CEMRA in comparison to those obtained by conventional X-ray angiography (CXA). Methods: Retrospective blinded measurement of the diameters of aorta and pulmonary arteries on the CEMRA and CXA images, in the same locations. Comparison of the results by Pearson correlation and by calculating the limits of agreement. Results: Twenty-one children with congenital heart disease, mean age 5.6 +- 5.2 years, weight 21.1 +- 18.4 kg, underwent CEMRA and catheterization for assessment or treatment of a residual lesion. The time interval between the CEMRA and the CXA examination was 2.6 +- 2.3 months. A total of 98 measurements, 37 of the aorta and 61 of the pulmonary arteries were performed on the images obtained by each technique. The correlation between CEMRA and CXA measurements was excellent, r = 0.97, p < 0.0001. The mean difference between the two techniques was 0.018 +- 1.1mm; the limits of agreement were -2.14 and +2.18mm. Similar agreement was found for measures of the aorta (r +- 0.97, mean difference 0.20 = 1.08 mm) and of the pulmonary arteries (r +- 0.97, mean difference 0.048 = 0.89 mm). Conclusions: CEMRA provide accurate quantitative anatomical information, which highly agrees with CXA data, and can therefore be used for planning interventional catheterization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: This study evaluates sealing characteristics of two designs of endovascular grafts by angiographic demonstration of exclusion of porcine lumbar arteries. METHODS: 6 endovascular grafts (3 self-expandable with integrated polyurethane wall versus 3 nitinol structures covered with polyester fabric) were implanted in 6 porcine aortae. Perfusion of lumbar arteries was assessed by angiography after implantation and by angiography and dissection at graft explantation after 4 +/- 2 months. Tissue healing was evaluated by light and scanning electron microscopy. RESULTS: Immediate exclusion of the lumbar arteries was achieved in 14/31 vessels (12 by polyurethane grafts and 2 by polyester grafts, p < 0.001). Follow-up angiography and dissection at explantation revealed perfusion of 30/31 lumbar arteries with a collateral network in most cases. Another reason for reperfusion of initially excluded branches was distention of the polyurethane grafts with resulting shortening allowing reperfusion of 8 of the 31 originally covered branches. Histological examination revealed a complete neointimal lining and a tight contact between endovascular grafts and aorta. CONCLUSIONS: The immediate angiographic demonstration of exclusion of lumbar arteries predicts sealing characteristics of endovascular grafts. Later angiographic reappearance is due to development of a collateral network and possible shortening of self-expandable devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the utility of inversion recovery with on-resonant water suppression (IRON) in combination with injection of the long-circulating monocrystalline iron oxide nanoparticle (MION)-47 for contrast material-enhanced magnetic resonance (MR) angiography. MATERIALS AND METhods: Experiments were approved by the institutional animal care committee. Eleven rabbits were imaged at baseline before injection of a contrast agent and then serially 5-30 minutes, 2 hours, 1 day, and 3 days after a single intravenous bolus injection of 80 micromol of MION-47 per kilogram of body weight (n = 6) or 250 micromol/kg MION-47 (n = 5). Conventional T1-weighted MR angiography and IRON MR angiography were performed on a clinical 3.0-T imager. Signal-to-noise and contrast-to-noise ratios were measured in the aorta of rabbits in vivo. Venous blood was obtained from the rabbits before and after MION-47 injection for use in phantom studies. RESULTS: In vitro blood that contained MION-47 appeared signal attenuated on T1-weighted angiograms, while characteristic signal-enhanced dipolar fields were observed on IRON angiograms. In vivo, the vessel lumen was signal attenuated on T1-weighted MR angiograms after MION-47 injection, while IRON supported high intravascular contrast by simultaneously providing positive signal within the vessels and suppressing background tissue (mean contrast-to-noise ratio, 61.9 +/- 12.4 [standard deviation] after injection vs 1.1 +/- 0.4 at baseline, P < .001). Contrast-to-noise ratio was higher on IRON MR angiograms than on conventional T1-weighted MR angiograms (9.0 +/- 2.5, P < .001 vs IRON MR angiography) and persisted up to 24 hours after MION-47 injection (76.2 +/- 15.9, P < .001 vs baseline). CONCLUSION: IRON MR angiography in conjunction with superparamagnetic nanoparticle administration provides high intravascular contrast over a long time and without the need for image subtraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. MATERIAL AND METHODS: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. RESULTS: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. CONCLUSION: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aortic access problems due to diseased or small peripheral vessels are a major issue in endovascular aneurysm repair (EVAR). In the emergency setting, like aortic rupture after blunt trauma, or in patients with a hostile abdomen, a more proximal access to the aorta is not a pleasant perspective. We developed in situ introducer sheath dilatation as a bail-out technique for patients with difficult aortic access under various circumstances including EVAR, intra-aortic balloon pump insertion and cannulation for perfusion. The method described allows to increase the access vessel diameter by 50% (from 6 to 9 mm) or the luminal circumference from 18 to 27 F. We have used this technique in five patients without complication, very much in contrast to the traditionally practiced 'forced device insertion'.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Between September 1979 and December 1982, 56 St Jude Medical valvular prostheses were implanted in 54 patients over 65 years of age. Surgery consisted in simple aortic valve replacement (35 cases), simple mitral valve replacement (12 cases), double aortic and mitral valve replacement (2 cases), valve replacement and coronary artery bypass surgery (3 cases), aortic valve replacement and replacement of the ascending aorta (1 case) and mitral valve replacement and tricuspid annuloplasty (1 case). The operative mortality (within 30 days of surgery) was 3.5% (2 cases). Patients were assessed by clinical examination, ECG, chest X-ray, echocardiogram and laboratory investigations on average 19 months after surgery. There were 3 late deaths (1 endocarditis, 1 cardiac failure and 1 subdural haematoma). No cases of significant haemolysis were observed. There were no cases of thrombosis of the valve or any deaths directly related to the valve. Four patients had cerebral embolism (4.9% per patient/year). None were fatal and only 1 patient had sequellae. Clinical improvement was very significant; 96% of the patients are now in the NYHA Classes I and II whilst 80% were in Class III or IV before surgery. The cardiothoracic ratio decreased significantly from 0.56 to 0.51 (p less than 0.01). The authors conclude that elderly patients may derive great benefits from valvular cardiac surgery and that age in itself is not a contraindication to this type of surgery. The St Jude Medical prosthesis is an excellent prosthesis but thromboembolism remains a major problem as with other mechanical prostheses. Anticoagulation for life is essential.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In pediatric echocardiography, cardiac dimensions are often normalized for weight, height, or body surface area (BSA). The combined influence of height and weight on cardiac size is complex and likely varies with age. We hypothesized that increasing weight for height, as represented by body mass index (BMI) adjusted for age, is poorly accounted for in Z scores normalized for weight, height, or BSA. We aimed to evaluate whether a bias related to BMI was introduced when proximal aorta diameter Z scores are derived from bivariate models (only one normalizing variable), and whether such a bias was reduced when multivariable models are used. We analyzed 1,422 echocardiograms read as normal in children ≤18 years. We computed Z scores of the proximal aorta using allometric, polynomial, and multivariable models with four body size variables. We then assessed the level of residual association of Z scores and BMI adjusted for age and sex. In children ≥6 years, we found a significant residual linear association with BMI-for-age and Z scores for most regression models. Only a multivariable model including weight and height as independent predictors produced a Z score free of linear association with BMI. We concluded that a bias related to BMI was present in Z scores of proximal aorta diameter when normalization was done using bivariate models, regardless of the regression model or the normalizing variable. The use of multivariable models with weight and height as independent predictors should be explored to reduce this potential pitfall when pediatric echocardiography reference values are evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Urgent reoperative transapical aortic valve-in-valve has never been proposed as a treatment option in case of a failed transcatheter aortic valve implantation (TAVI) or in case of worsening of an existing paravalvular leak, if this complication occurs right after, or a few days after, the primary transapical aortic valve implantation. Experienced surgeons should argue that after a transapical TAVI, the apex is damaged and fragile, with a high risk of irreparable ventricular tears and life-threatening bleeding if a second transapical procedure is scheduled during the acute phase. Nevertheless, if the patient is inoperable and the vascular status, including the ascending aorta, limits alternative accesses, the urgent reoperative transapical valve-in-valve becomes an alternative. We illustrate, for the first time ever, our experience with an 81-year old female patient who underwent a transapical (TA) TAVI with a Sapien? XT 23 mm. The day after the procedure, the patient haemodynamically worsened in combination with a worsening of a known (grade 1-2) paravalvular leak. Thus, on postoperative day two, an urgent transapical valve-in-valve was performed, and a second Sapien? XT 23 mm was placed, with an excellent haemodynamic result and absence of leak. The redo apical access did not appear very complicated and the postoperative recovery was uneventful.