118 resultados para animal precision
Resumo:
Background and Objectives: Precursor lesions of oesophagus adenocarcinoma constitute a clinical dilemma. Photodynamic therapy (PDT) is an effective treatment for this indication, but it is difficult to optimise without an appropriate animal model. For this reason, we assessed the sheep model for PDT in the oesophagus with the photosensitiser meta-(tetra-hydroxyphenyl) chlorin (mTHPC). Materials and Methods: Twelve sheep underwent intravenous mTHPC injection, blood sampling and fluorescence measurements. mTHPC's pharmacokinetics was measured in vivo and in plasma by fluorescence spectroscopy. Biopsies of sheep oesophagus were compared to corresponding human tissue, and the mTHPC's biodistribution was studied under fluorescence microscopy. Finally, the sheep oesophageal mucosa was irradiated, 4 days after mTHPC's injection. Results: Histologically, the sheep and human oesophagus were closely comparable, with the exception of additional fatty tissue in the sheep oesophagus. mTHPC's pharmacokinetics in sheep and human plasmas were similar, with a maximum of concentration in the sheep 10 hours after i.v. injection. mTHPC's pharmacokinetics in vivo reached its maximum after 30-50 hours, then decreased to background levels, as in humans under similar conditions. Two days after injection, mTHPC was mainly distributed in the lamina propria, followed by a penetration into the epithelium. The sheep and human tissue sensitivity to mTHPC PDT was similar. Conclusion: In conclusion, this model showed many similarities with humans as to mTHPC's plasma and tissue pharmacokinetics, and for tissue PDT response, making it suitable to optimise oesophagus PDT. Lasers Surg. Med. 41:643-652,2009. (C) 2009Wiley-Liss,Inc.
Resumo:
Peptide toxins synthesized by venomous animals have been extensively studied in the last decades. To be useful to the scientific community, this knowledge has been stored, annotated and made easy to retrieve by several databases. The aim of this article is to present what type of information users can access from each database. ArachnoServer and ConoServer focus on spider toxins and cone snail toxins, respectively. UniProtKB, a generalist protein knowledgebase, has an animal toxin-dedicated annotation program that includes toxins from all venomous animals. Finally, the ATDB metadatabase compiles data and annotations from other databases and provides toxin ontology.
Resumo:
Introduction: Accurate and reproducible tibial tunnel placement minimizing the risk of neurovascular damage is a crucial condition for successful arthroscopic reconstruction of the posterior cruciate ligament (PCL). This step is commonly performed under fluoroscopic control. Hypothesis: Performing the tibial tunnel under exclusive arthroscopic control allows accurate and reliable tunnel placement according to recommendations in the literature. Materials and Methods: Between February 2007 and December 2009, 108 arthroscopic single bundle PCL reconstructions in tibial tunnel technique were performed. The routine postoperative radiographs were screened according to previously defined quality criterions. After critical analysis, the radiographs of 48 patients (48 knees) were enrolled in the study. 10 patients had simultaneous ACL reconstruction and 7 had PCL revision surgery. The tibial tunnel was placed under direct arthroscopic control through a posteromedial portal using a standard tibial aming device. Key anatomical landmarks were the exposed tibial insertion of the PCL and the posterior horn of the medial meniscus. First, the centre of the posterior tibial tunnel outlet on the a-p view was determined by digital analysis of the postoperative radiographes. Its distance to the medial tibial spine was measured parallel to the tibia plateau. The mediolateral position was expressed by the ratio between the distance of the tunnel outlet to the medial border and the total width of the tibial plateau. On the lateral view the vertical tunnel position was measured perpendicularly to a tangent of the medial tibial plateau. All measurement were repeated at least twice and carried out by two examiners. Results: The mean mediolateral tunnel position was 49.3 ± 4.6% (ratio), 6.7 ± 3.6 mm lateral to the medial tibial spine. On the lateral view the tunnel centre was 10.1 ± 4.5 mm distal to the bony surface of the medial tibial plateau. Neurovascular damage was observed in none of our patients. Conclusion: The results of this radiological study confirm that exclusive arthroscopic control for tibial tunnel placement in PCL reconstruction yields reproducible and accurate results according to the literature. Our technique avoids radiation, facilitates the operation room setting and enables the surgeon to visualize the anatomic key landmarks for tibial tunnel placement.
Resumo:
Purpose: To evaluate the toxicity focussing on hepatic, gastrointestinal and cardiac parameters following PRECISION TACE with DC Bead? versus conventional transarterial chemoembolization (cTACE) in the treatment of intermediate-stage hepatocellular carcinoma (HCC). Methods and Materials: This prospective, randomized, multicentre study was conducted under best practice trial management and authorized by local institutional review boards. Informed consent was obtained. 212 patients (185 men/27 women; mean: 67 years) were randomized to be treated with DC Beads? or cTACE. The majority of both groups presented in a more advanced stage. Safety was measured by rate of adverse events (South West Oncology Group criteria) and changes in laboratory parameters. Cardiotoxicity was assessed by means of left ventricular ejection fraction (LVEF) in MRI or echocardiography. The results of the two groups were compared using the chi-square test and Student`s t-test. Results: Mean maximum alanine transaminase increase in the DC Bead group was 50% in the cTACE group (p < 0.001) and 59% for aspartate transaminase (p < 0.001). For bilirubin, mean increase was 5.30±15.13 vs. 13.53±73.89 µmol/L. Concerning gastrointestinal disorders, 120 adverse events (AEs) occurred in 57/93 (61.3%) patients in the DC Bead group vs. 114 in 49/108 (45.4%) in cTACE. Concerning hepatobiliary disorders, serious AEs occurred in 8/93 (8.6%) vs. 11/108 (10.2%) patients. LVEF showed an increase in the DC Bead group by +2.7±10.1 percentage points and a small decrease by -1.5±7.6 in the cTACE group, p=0.018. Conclusion: PRECISION TACE is safe, even in more advanced HCC patients. Serious liver and cardiac toxicity were significantly lower in the DC Bead group.
Resumo:
We present a novel and straightforward method for estimating recent migration rates between discrete populations using multilocus genotype data. The approach builds upon a two-step sampling design, where individual genotypes are sampled before and after dispersal. We develop a model that estimates all pairwise backwards migration rates (m(ij), the probability that an individual sampled in population i is a migrant from population j) between a set of populations. The method is validated with simulated data and compared with the methods of BayesAss and Structure. First, we use data for an island model and then we consider more realistic data simulations for a metapopulation of the greater white-toothed shrew (Crocidura russula). We show that the precision and bias of estimates primarily depend upon the proportion of individuals sampled in each population. Weak sampling designs may particularly affect the quality of the coverage provided by 95% highest posterior density intervals. We further show that it is relatively insensitive to the number of loci sampled and the overall strength of genetic structure. The method can easily be extended and makes fewer assumptions about the underlying demographic and genetic processes than currently available methods. It allows backwards migration rates to be estimated across a wide range of realistic conditions.
Resumo:
Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.
Resumo:
The antifungal agent fluconazole (FLC) is widely used in clinical practice. Monitoring FLC levels is useful in complicated clinical settings and in experimental infection models. A bioassay using Candida pseudotropicalis, a simple and cost-effective method, is validated only for FLC levels ranging from 5 to 40 mg/liter. An extension of the analytical range is needed to cover most yeast MICs. A new bioassay in RPMI agar containing methylene blue was developed using C. albicans DSY1024, a mutant rendered hypersusceptible to FLC constructed by the deletion of the multidrug efflux transporter genes CDR1, CDR2, CaMDR1, and FLU1. Reproducible standard curves were obtained with FLC concentrations in plasma ranging from 1 to 100 mg/liter (quadratic regression coefficient > 0.997). The absolute sensitivity was 0.026 microg of FLC. The method was internally validated according to current guidelines for analytical method validation. Both accuracy and precision lied in the required +/-15% range. FLC levels measured by bioassay and by high-performance liquid chromatography (HPLC) performed with 62 plasma samples from humans and rats showed a strong correlation (coefficients, 0.979 and 0.995, respectively; percent deviations of bioassay from HPLC values, 0.44% +/- 15.31% and 2.66% +/- 7.54%, respectively). In summary, this newly developed bioassay is sensitive, simple, rapid, and inexpensive. It allows nonspecialized laboratories to determine FLC levels in plasma to within the clinically relevant concentration range and represents a useful tool for experimental treatment models.
Resumo:
Morphogen gradients infer cell fate as a function of cellular position. Experiments in Drosophila embryos have shown that the Bicoid (Bcd) gradient is precise and exhibits some degree of scaling. We present experimental results on the precision of Bcd target genes for embryos with a single, double or quadruple dose of bicoid demonstrating that precision is highest at mid-embryo and position dependent, rather than gene dependent. This confirms that the major contribution to precision is achieved already at the Bcd gradient formation. Modeling this dynamic process, we investigate precision for inter-embryo fluctuations in different parameters affecting gradient formation. Within our modeling framework, the observed precision can only be achieved by a transient Bcd profile. Studying different extensions of our modeling framework reveals that scaling is generally position dependent and decreases toward the posterior pole. Our measurements confirm this trend, indicating almost perfect scaling except for anterior most expression domains, which overcompensate fluctuations in embryo length.
Resumo:
Precise MEG estimates of neuronal current flow are undermined by uncertain knowledge of the head location with respect to the MEG sensors. This is either due to head movements within the scanning session or systematic errors in co-registration to anatomy. Here we show how such errors can be minimized using subject-specific head-casts produced using 3D printing technology. The casts fit the scalp of the subject internally and the inside of the MEG dewar externally, reducing within session and between session head movements. Systematic errors in matching to MRI coordinate system are also reduced through the use of MRI-visible fiducial markers placed on the same cast. Bootstrap estimates of absolute co-registration error were of the order of 1mm. Estimates of relative co-registration error were <1.5mm between sessions. We corroborated these scalp based estimates by looking at the MEG data recorded over a 6month period. We found that the between session sensor variability of the subject's evoked response was of the order of the within session noise, showing no appreciable noise due to between-session movement. Simulations suggest that the between-session sensor level amplitude SNR improved by a factor of 5 over conventional strategies. We show that at this level of coregistration accuracy there is strong evidence for anatomical models based on the individual rather than canonical anatomy; but that this advantage disappears for errors of greater than 5mm. This work paves the way for source reconstruction methods which can exploit very high SNR signals and accurate anatomical models; and also significantly increases the sensitivity of longitudinal studies with MEG.
Resumo:
With the aim of improving human health, scientists have been using an approach referred to as translational research, in which they aim to convey their laboratory discoveries into clinical applications to help prevent and cure disease. Such discoveries often arise from cellular, molecular, and physiological studies that progress to the clinical level. Most of the translational work is done using animal models that share common genes, molecular pathways, or phenotypes with humans. In this article, we discuss how translational work is carried out in various animal models and illustrate its relevance for human sleep research and sleep-related disorders.
Resumo:
A carrier system for gases and nutrients became mandatory when primitive animals grew larger and developed different organs. The first circulatory systems are peristaltic tubes pushing slowly the haemolymph into an open vascular tree without capillaries (worms). Arthropods developed contractile bulges on the abdominal aorta assisted by accessory hearts for wings or legs and by abdominal respiratory motions. Two-chamber heart (atrium and ventricle) appeared among mollusks. Vertebrates have a multi-chamber heart and a closed circulation with capillaries. Their heart has two chambers in fishes, three chambers (two atria and one ventricle) in amphibians and reptiles, and four chambers in birds and mammals. The ventricle of reptiles is partially divided in two cavities by an interventricular septum, leaving only a communication of variable size leading to a variable shunt. Blood pressure increases progressively from 15 mmHg (worms) to 170/70 mmHg (birds) according to the increase in metabolic rate. When systemic pressure exceeds 50 mmHg, a lower pressure system appears for the circulation through gills or lungs in order to improve gas exchange. A four-chamber heart allows a complete separation of systemic and pulmonary circuits. This review describes the circulatory pumping systems used in the different classes of animals, their advantages and failures, and the way they have been modified with evolution.