246 resultados para accelerated permeability test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We advocate the use of a novel compressed sensing technique for accelerating the magnetic resonance image acquisition process, coined spread spectrum MR imaging or simply s2MRI. The method resides in pre-modulating the signal of interest by a linear chirp, resulting from the application of quadratic phase profiles, before random k-space under-sampling with uniform average density. The effectiveness of the procedure is theoretically underpinned by the optimization of the coherence between the sparsity and sensing bases. The application of the technique for single coil acquisitions is thoroughly studied by means of numerical simulations as well as phantom and in vivo experiments on a 7T scanner. The corresponding results suggest a favorable comparison with state-of-the-art variable density k-space under-sampling approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A test kit based on living, lyophilized bacterial bioreporters emitting bioluminescence as a response to arsenite and arsenate was applied during a field campaign in six villages across Bangladesh. Bioreporter field measurements of arsenic in groundwater from tube wells were in satisfying agreement with the results of spectroscopic analyses of the same samples conducted in the lab. The practicability of the bioreporter test in terms of logistics and material requirements, suitability for high sample throughput, and waste disposal was much better than that of two commercial chemical test kits that were included as references. The campaigns furthermore demonstrated large local heterogeneity of arsenic in groundwater, underscoring the use of well switching as an effective remedy to avoid high arsenic exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare species have restricted geographic ranges, habitat specialization, and/or small population sizes. Datasets on rare species distribution usually have few observations, limited spatial accuracy and lack of valid absences; conversely they provide comprehensive views of species distributions allowing to realistically capture most of their realized environmental niche. Rare species are the most in need of predictive distribution modelling but also the most difficult to model. We refer to this contrast as the "rare species modelling paradox" and propose as a solution developing modelling approaches that deal with a sufficiently large set of predictors, ensuring that statistical models aren't overfitted. Our novel approach fulfils this condition by fitting a large number of bivariate models and averaging them with a weighted ensemble approach. We further propose that this ensemble forecasting is conducted within a hierarchic multi-scale framework. We present two ensemble models for a test species, one at regional and one at local scale, each based on the combination of 630 models. In both cases, we obtained excellent spatial projections, unusual when modelling rare species. Model results highlight, from a statistically sound approach, the effects of multiple drivers in a same modelling framework and at two distinct scales. From this added information, regional models can support accurate forecasts of range dynamics under climate change scenarios, whereas local models allow the assessment of isolated or synergistic impacts of changes in multiple predictors. This novel framework provides a baseline for adaptive conservation, management and monitoring of rare species at distinct spatial and temporal scales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND/AIMS: While several risk factors for the histological progression of chronic hepatitis C have been identified, the contribution of HCV genotypes to liver fibrosis evolution remains controversial. The aim of this study was to assess independent predictors for fibrosis progression. METHODS: We identified 1189 patients from the Swiss Hepatitis C Cohort database with at least one biopsy prior to antiviral treatment and assessable date of infection. Stage-constant fibrosis progression rate was assessed using the ratio of fibrosis Metavir score to duration of infection. Stage-specific fibrosis progression rates were obtained using a Markov model. Risk factors were assessed by univariate and multivariate regression models. RESULTS: Independent risk factors for accelerated stage-constant fibrosis progression (>0.083 fibrosis units/year) included male sex (OR=1.60, [95% CI 1.21-2.12], P<0.001), age at infection (OR=1.08, [1.06-1.09], P<0.001), histological activity (OR=2.03, [1.54-2.68], P<0.001) and genotype 3 (OR=1.89, [1.37-2.61], P<0.001). Slower progression rates were observed in patients infected by blood transfusion (P=0.02) and invasive procedures or needle stick (P=0.03), compared to those infected by intravenous drug use. Maximum likelihood estimates (95% CI) of stage-specific progression rates (fibrosis units/year) for genotype 3 versus the other genotypes were: F0-->F1: 0.126 (0.106-0.145) versus 0.091 (0.083-0.100), F1-->F2: 0.099 (0.080-0.117) versus 0.065 (0.058-0.073), F2-->F3: 0.077 (0.058-0.096) versus 0.068 (0.057-0.080) and F3-->F4: 0.171 (0.106-0.236) versus 0.112 (0.083-0.142, overall P<0.001). CONCLUSIONS: This study shows a significant association of genotype 3 with accelerated fibrosis using both stage-constant and stage-specific estimates of fibrosis progression rates. This observation may have important consequences for the management of patients infected with this genotype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using quantitative fluorescence in situ hybridization and flow cytometry, the telomere length of telomere repeat sequences after stem cell transplantation (SCT) were measured. The study included the telomeres of peripheral blood monocytes that should reflect the length of telomeres in stem cells and the telomeres of T lymphocytes that could shorten as a result of peripheral expansion. The loss of telomeres in monocytes and in memory T cells, although accelerated initially, became comparable to the loss of telomeres in healthy controls from the second year after transplantation. In addition, the telomere length in the naive T cells that were produced by the thymus was comparable to the telomere length in the naive T cells of the donor. Compared to the total length of telomeres available, the loss of telomere repeats in leukocytes after SCT resembles the accelerated shortening seen in early childhood and remains, therefore, relatively insignificant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The epithelial Na(+) channel (ENaC), located in the apical membrane of tight epithelia, allows vectorial Na(+) absorption. The amiloride-sensitive ENaC is highly selective for Na(+) and Li(+) ions. There is growing evidence that the short stretch of amino acid residues (preM2) preceding the putative second transmembrane domain M2 forms the outer channel pore with the amiloride binding site and the narrow ion-selective region of the pore. We have shown previously that mutations of the alphaS589 residue in the preM2 segment change the ion selectivity, making the channel permeant to K(+) ions. To understand the molecular basis of this important change in ionic selectivity, we have substituted alphaS589 with amino acids of different sizes and physicochemical properties. Here, we show that the molecular cutoff of the channel pore for inorganic and organic cations increases with the size of the amino acid residue at position alpha589, indicating that alphaS589 mutations enlarge the pore at the selectivity filter. Mutants with an increased permeability to large cations show a decrease in the ENaC unitary conductance of small cations such as Na(+) and Li(+). These findings demonstrate the critical role of the pore size at the alphaS589 residue for the selectivity properties of ENaC. Our data are consistent with the main chain carbonyl oxygens of the alphaS589 residues lining the channel pore at the selectivity filter with their side chain pointing away from the pore lumen. We propose that the alphaS589 side chain is oriented toward the subunit-subunit interface and that substitution of alphaS589 by larger residues increases the pore diameter by adding extra volume at the subunit-subunit interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From November 1992 to December 1997, 25 patients (inoperable or refusing cystectomy) were included in a prospective study to assess the feasibility, tolerance, and curative potential of accelerated radiotherapy (RT) and concomitant cisplatin. Median age was 74 years (range 49-86). Stage distribution was as follows: 1 T1, 10 T2, 8 T3, and 6 T4. Two patients had clinically positive pelvic nodes. The goal was to deliver a total dose of 40 Gy to the whole pelvis and bladder in 4 weeks using a concomitant boost of 20 Gy to the tumor or to the whole bladder during the third and fourth weeks (total dose 60 Gy), with daily cisplatin (6 mg/m(2)) before RT for patients with creatinine clearance > 50 ml/min. All but one patient completed the RT protocol. Daily cisplatin was successfully delivered in 18 patients. One patient presented with grade III ototoxicity. Diarrhea was scored grade III in two and grade IV in two patients. Acute urinary toxicity was scored grade III in one patient. Posttreatment late effects included bladder grade II and grade III in two patients and one patient, respectively; large bowel grade III in one; urethral grade III in one; and femoral head radionecrosis in one. Four-year overall and disease-specific survival rates were 23% and 35%, respectively. The latter was 60% for patients with T2 tumors. The 4-year actuarial locoregional control rate for all patients was 61%. In summary, accelerated RT and concomitant cisplatin is feasible with acceptable tolerance even in relatively old patients. Although outcome was better for patients with low-stage tumors, local control and survival rates appeared similar to those of standard RT schedules for a similar patient population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern sonic logging tools designed for shallow environmental and engineering applications allow for P-wave phase velocity measurements over a wide frequency band. Methodological considerations indicate that, for saturated unconsolidated sediments in the silt to sand range and source frequencies ranging from approximately 1 to 30 kHz, the observable poro-elastic P-wave velocity dispersion is sufficiently pronounced to allow for reliable first-order estimations of the underlying permeability structure. These predictions have been tested on and verified for a surficial alluvial aquifer. Our results indicate that, even without any further calibration, the thus obtained permeability estimates as well as their variabilities within the pertinent lithological units are remarkably close to those expected based on the corresponding granulometric characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims and objectives  This study aimed to determine the discriminant validity and the test-retest reliability of a questionnaire testing the impact of evidence-based medicine (EBM) training on doctors' knowledge and skills. Methods  Questionnaires were sent electronically to all doctors working as residents and chief residents in two French speaking hospital networks in Switzerland. Participants completed the questionnaire twice, within a 4-week interval. The discriminant validity was examined in comparing doctors' performance according to their reported EBM previous training. Proportion of agreement between both sessions of the questionnaire, Cohen's kappa and 'uniform kappa' determined its test-retest reliability. Results  The participation rate was 9.8%/7.1% to first/second session. Performance increased according to the level of doctors' previous training in EBM. The observed proportion of agreement between both sessions was over 70% for 14/19 questions, and the 'uniform kappa' was superior to 0.60 for 15/19 questions. Conclusion  The discriminant validity and test-retest reliability of the questionnaire were satisfying. The low participation rate did not prevent the study from achieving its aims.