286 resultados para Transcatheter aortic valve replacement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mitral valve injury after blunt chest trauma is a rare occurrence. We recently admitted a patient with severe traumatic mitral regurgitation who was successfully treated with surgery. Review of the literature aimed at taking an inventory of cases of traumatic nonpenetrating mitral insufficiency that were operated on, since the earliest report in 1964. Eighty-two cases were found and analyzed allowing for a better understanding of the epidemiology, etiology, natural history, pathology, and treatment of this rare condition. The most common lesions reach the papillary muscles (PM), followed by the chordae and then the mitral valve leaflets. Among the 82 cases reported that have been treated with surgery, 57% required a valve replacement. More than half of the patients had a PM injury with a complete or partial rupture. When the rupture is complete, and especially when it involves the anterior PM, the clinical picture is most always acute with clinically important hemodynamic repercussions, often necessitating emergency surgery, most of the time with mitral valve replacement. One must always suspect traumatic mitral injury after blunt chest trauma. The most common mitral lesions affect the PM. The clinical course can be indolent or devastating, and most often requires urgent or delayed surgical treatment, either with mitral valve repair or replacement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The Contegra bioprosthesis (valved heterologous bovine jugular vein) is used for reconstruction of the right ventricular outflow tract (RVOT) in congenital heart malformations and pulmonary valve replacement in different settings. Compared to pulmonary homografts, the Contegra conduit is readily available 'on the shelf'. So far, its use was mainly described in children. The aim of this study is to evaluate the feasibility and the outcome of Contegra graft implantation in the adult. METHODS: Between November 1999 and December 2007, a total of 32 Contegra grafts were implanted in 31 patients (24 men and 7 women), with a mean age of 35.7+/-10.5 years (range 18-54 years). All operations have been completed through median sternotomy with cardiopulmonary bypass. Indications included: Ross procedure for aortic valve disease (n=22); re-operation of corrected Fallot-tetralogy (n=5); isolated pulmonary valve disease (n=2); re-operation of double outlet right ventricle (DORV) (n=1); pulmonary stenosis in congenital dilated cardiomyopathy (DCM) (n=1). Conduit sizes included 22 mm (n=31), 20 mm (n=1). RESULTS: There was no hospital mortality and no valved conduit related early morbidity. In the median follow-up of 38 months (range 1-99 months) of 28 patients there was one late death, not conduit related (total mortality 3.6%). Re-operation for symptomatic graft stenosis was realised in two patients, 7 and 16 months after primo-implantation, corresponding to graft related late morbidity of 7.1%. CONCLUSIONS: In this small review of 32 operations using the Contegra graft for RVOT reconstruction in adult cardiac surgery for different indications, we observed good postoperative mid-term results concerning conduit function. Mean transpulmonary pressure gradients remain low (13.3+/-6.6 mmHg postoperative, 14.5+/-7.9 mmHg at follow-up). The use of the Contegra graft seems to be a good alternative to the homograft with low operative mortality and morbidity. Long-term outcome data are not available and further investigations must be performed to evaluate results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Echocardiography is a key tool in the diagnosis of infective endocarditis. Although transthoracic echocardiography is the first step in the work-up, transoesophageal echocardiography is mandatory for the evaluation of the exact extent of the infectious process. Indeed, perivalvular abscess can fistulate towards different heart chambers, leading sometimes to critical clinical situations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An unusual case of localized amyloid light-chain (AL) amyloidosis and extramedullary plasmacytoma of the mitral valve is described. The worsening of a mitral regurgitation led to investigations and surgery. The valve presented marked distortion and thickening by type AL amyloid associated with a monotypic CD138+ immunoglobulin lambda plasma cell proliferation. Systemic staging showed a normal bone marrow and no evidence of amyloid deposition in other localizations. The patient's outcome after mitral valve replacement was excellent. To our knowledge, this is the first description of a localized AL amyloidosis as well as of a primary extramedullary plasmacytoma of the mitral valve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: MR tissue tagging allows the noninvasive assessment of the locally and temporally resolved motion pattern of the left ventricle. Alterations in cardiac torsion and diastolic relaxation of the left ventricle were studied in patients with aortic stenosis and were compared with those of healthy control subjects and championship rowers with physiological volume-overload hypertrophy. METHODS AND RESULTS: Twelve aortic stenosis patients, 11 healthy control subjects with normal left ventricular function, and 11 world-championship rowers were investigated for systolic and diastolic heart wall motion on a basal and an apical level of the myocardium. Systolic torsion and untwisting during diastole were examined by use of a novel tagging technique (CSPAMM) that provides access to systolic and diastolic motion data. In the healthy heart, the left ventricle performs a systolic wringing motion, with a counterclockwise rotation at the apex and a clockwise rotation at the base. Apical untwisting precedes diastolic filling. In the athlete's heart, torsion and untwisting remain unchanged compared with those of the control subjects. In aortic stenosis patients, torsion is significantly increased and diastolic apical untwisting is prolonged compared with those of control subjects or athletes. CONCLUSIONS: Torsional behavior as observed in pressure- and volume-overloaded hearts is consistent with current theoretical findings. A delayed diastolic untwisting in the pressure-overloaded hearts of the patients may contribute to a tendency toward diastolic dysfunction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interventional paediatric and congenital cardiology is expanding at a rapid pace. Validated techniques (such as aortic or pulmonary valve dilatations and occlusion of persistent ductus arteriosus and atrial septal defects) are improving thanks to the use of smaller introducers and sheaths, low-profile balloons and novel devices. Moreover, catheter-based interventions have emerged as an attractive alternative to surgery in other fields: pulmonary valve replacement, balloon and stent implantation for native and recurrent coarctation, and percutaneous closure of ventricular septal defects. On the other hand, percutaneous interventions in the paediatric population may be limited by patient size or the anatomy of the defect. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. Based on a better understanding of cardiac development, fetal cardiac interventions are being attempted in order to alter the history of severe obstructive lesions. Finally, some interventional procedures still carry a low success rate-for example, pulmonary vein stenosis, even with the use of conventional stents. Biodegradable stents and devices are being developed and may find an application in this setting as well as in others. The purpose of this review is to highlight the advances in paediatric interventional cardiology since the beginning of the third millennium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three cases are reported of salmonella aortitis observed in three men aged 55, 60 and 48 years, the last of whom had a prosthetic aortic valve and ascending aorta. The microorganisms were S. typhi murium, S. paratyphi B, and S. wien. Despite antibiotic treatment two patients died of perforating aortitis. The third patient developed S. wien gastroenteritis a few days after surgical replacement of the aortic valve and the ascending aorta. Five years later he presented with several bacteremic episodes due to S. wien, which recurred despite several courses of cotrimoxazole treatment. He has now been asymptomatic for over one year under prolonged cotrimoxazole treatment. Since vascular infection may occur following non typhi salmonellosis in 5% of patients over 50, or who have underlying endothelial lesions, the question arises as to whether non typhi S. gastroenteritis should be treated with antibiotics in these high risk patients, in contrast to present recommendations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Left ventricular hypertrophy (LVH) is due to pressure overload or mechanical stretch and is thought to be associated with remodeling of gap-junctions. We investigated whether the expression of connexin 43 (Cx43) is altered in humans in response to different degrees of LVH. The expression of Cx43 was analyzed by quantitative polymerase chain reaction, Western blot analysis and immunohistochemistry on left ventricular biopsies from patients undergoing aortic or mitral valve replacement. Three groups were analyzed: patients with aortic stenosis with severe LVH (n=9) versus only mild LVH (n=7), and patients with LVH caused by mitral regurgitation (n=5). Cx43 mRNA expression and protein expression were similar in the three groups studied. Furthermore, immunohistochemistry revealed no change in Cx43 distribution. We can conclude that when compared with mild LVH or with LVH due to volume overload, severe LVH due to chronic pressure overload is not accompanied by detectable changes of Cx43 expression or spatial distribution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary artery sarcomas are uncommon intracardiac tumours with poor prognosis. We report the case of a 69-year-old woman in good health presenting with rapidly progressive dyspnoea and an unfamiliar systolic murmur. Echocardiography revealed pulmonary valve stenosis due to an obstructing mobile mass. Imaging studies confirmed the presence of a contrast-enhancing lesion adherent to the valve, extending into the pulmonary trunk and right ventricular outflow tract, and suggestive of malignancy. Endovascular biopsy was attempted with no success. Surgical resection with autologous graft valve replacement and pulmonary artery reconstruction was performed. Postoperative histological examination confirmed the diagnosis of an undifferentiated pleomorphic sarcoma. Pulmonary artery sarcoma should be considered as a rare differential diagnosis in patients presenting with dyspnoea and a crescendo-decrescendo systolic murmur increasing with inspiration. Echocardiography is a useful first diagnostic approach but multi-imaging assessment is almost always necessary for definite diagnosis. Our case provides insights into the challenges met by cardiologists, radiologists and cardiac surgeons in the management of such cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Revolutionary endovascular treatments are on the verge of being available for management of ascending aortic diseases. Morphometric measurements of the ascending aorta have already been done with ECG-gated MDCT to help such therapeutic development. However the reliability of these measurements remains unknown. The objective of this work was to compare the intraobserver and interobserver variability of CAD (computer aided diagnosis) versus manual measurements in the ascending aorta. Methods and materials: Twenty-six consecutive patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters at mid-distance between the brachiocephalic artery and the aortic valve were obtained automatically with a commercially available CAD and manually by two observers separately. Both observers repeated the measurements during a different session at least one month after the first measurements. Intraclass coefficients as well the Bland and Altman method were used for comparison between measurements. Two-paired t-test was used to determine the significance of intraobserver and interobserver differences (alpha = 0.05). Results: There is a significant difference between CAD and manual measurements in the maximum diameter (p = 0.004) for the first observer, whereas the difference was significant for minimum diameter between the second observer and the CAD (p <0.001). Interobserver variability showed a weak agreement when measurements were done manually. Intraobserver variability was lower with the CAD compared to the manual measurements (limits of variability: from -0.7 to 0.9 mm for the former and from -1.2 to 1.3 mm for the latter). Conclusion: In order to improve reproductibility of measurements whenever needed, pre- and post-therapeutic management of the ascending aorta may benefit from follow-up done by a unique observer with the help of CAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When we think of cardiac affection in the context of systemic lupus erythematosus (SLE), we usually refer to pericarditis first. As frequent as this affection is, it is actually not the only cardio-vascular problem that occurs with this systemic inflammatory disease. Are the cardiac events--ranging from multiple heart valve involvements to increased cardiovascular risks--clinically significant? And are they involving a specific follow-up, treatment or support? We are therefore trying to evaluate these questions in order to give some recommendations to any practitioners following up a lupus patient, or a patient suffering from any other inflammatory systemic disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.