110 resultados para Tendon digital sheath


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Isolated avulsion fracture at the plantar lateral base of the first metatarsal (M1) is very rare. Case report: A 35 year old overweight woman sustained an eversion strain of her right foot. Despite pain along M1 she was able to continue walking for three days before presenting to her family doctor. Swelling on the plantar aspect of the foot was noticed, there was also pain at eversion of the foot and extension of the ankle. Plain X-ray showed no abnormalities. A MRI showed minimal bone bruise at the basis of M1 and a partial rupture of the peroneus longus tendon at its insertion. The patient was allowed to walk with partial weight bearing with a soft ankle brace. After 6 months she presented at our hospital because of persistent pain. There was still a painful insertion of the peroneus longus but active plantarflexion of M1 was possible. Plain X-rays were poorly contributive except for a discrete flattening of the longitunal arch. CT-scan showed a non displaced fracture at the M1-basis. A protocol with partial weight-bearing in a short-leg cast and partial weight-bearing orthosis each for 6 weeks was unsuccessfully attempted. Therefore, an excision of the non healed bone fragment at the basis of M1 and a first tarsometatarsal joint arthrodesis were performed. Postoperatively the patient wore a partial weight-bearing short leg cast for 6 weeks followed by a weight-bearing short leg cast for 6 weeks with favourable outcome. Discussion: Initial internal fixation has been reported to lead to good results [1, 2]. In our case the conservative treatment failed and leaded to non union. At that time we considered as too risky (overweight) to excise the fragment and reattach the peroneus longus tendon. Therefore, we excised the fragment and fused the first tarsometatarsal joint. This procedure allowed, at least partially, to compensate for the function of the peroneus longus tendon. 1 Murakami T, et al. Avulsion fracture of the peroneus longus at the first metatarsal insertion: a case report. Br J Sports Med. 2004. 2 Kwak HY, and Bae SW. Isolated avulsion fracture at the plantar lateral base of the first metatarsal: a case report. Foot Ankle Int 2000.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isolated avulsion fracture of the peroneus longus tendon insertion at the base of the first metatarsal is very rare. Similar to most avulsion fractures that result from excessive strain at a tendon or ligament insertion, this type of injury is caused by the strong tension exerted by the peroneus longus tendon. The mechanisms leading to this lesion and treatment options are not clearly defined. We present the case of an isolated minimally displaced intra-articular avulsion fracture at the plantar lateral base of the first metatarsal. Faced with a painful non-union following conservative treatment we considered excision of the bony fragment and first tarsometatarsal arthrodesis. This leads to a favourable functional outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was carried out to check whether classic osteometric parameters can be determined from the 3D reconstructions of MSCT (multislice computed tomography) scans acquired in the context of the Virtopsy project. To this end, four isolated and macerated skulls were examined by six examiners. First the skulls were conventionally (manually) measured using 32 internationally accepted linear measurements. Then the skulls were scanned by the use of MSCT with slice thicknesses of 1.25 mm and 0.63 mm, and the 33 measurements were virtually determined on the digital 3D reconstructions of the skulls. The results of the traditional and the digital measurements were compared for each examiner to figure out variations. Furthermore, several parameters were measured on the cranium and postcranium during an autopsy and compared to the values that had been measured on a 3D reconstruction from a previously acquired postmortem MSCT scan. The results indicate that equivalent osteometric values can be obtained from digital 3D reconstructions from MSCT scans using a slice thickness of 1.25 mm, and from conventional manual examinations. The measurements taken from a corpse during an autopsy could also be validated with the methods used for the digital 3D reconstructions in the context of the Virtopsy project. Future aims are the assessment and biostatistical evaluation in respect to sex, age and stature of all data sets stored in the Virtopsy project so far, as well as of future data sets. Furthermore, a definition of new parameters, only measurable with the aid of MSCT data would be conceivable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: There is a trend towards surgical treatment of acute ruptured Achilles tendon. While classical open surgical procedures have been shown to restore good functional capacity, they are potentially associated with significant complications like wound infection and paresthesia. Modern mini-invasive surgical techniques significantly reduce these complications and are also associated with good functional results so that they can be considered as the surgical treatment of choice. Nevertheless, there is still a need for conservative alternative and recent studies report good results with conservative treatment in rigid casts or braces. PATIENTS/METHOD: We report the use of a dynamic ankle brace in the conservative treatment of Achilles tendon rupture in a prospective non-randomised study of 57 consecutive patients. Patients were evaluated at an average follow-up time of 5 years using the modified Leppilahti Ankle Score, and the first 30 patients additionally underwent a clinical examination and muscular testing with a Cybex isokinetic dynamometer at 6 and 12 months. RESULTS: We found good and excellent results in most cases. We observed five complete re-ruptures, almost exclusively in case of poor patient's compliance, two partial re-ruptures and one deep venous thrombosis complicated by pulmonary embolism. CONCLUSION: Although prospective comparison with other modern treatment options is still required, the functional outcome after early ankle mobilisation in a dynamic cast is good enough to ethically propose this method as an alternative to surgical treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this review, we summarize how the new concept of digital optics applied to the field of holographic microscopy has allowed the development of a reliable and flexible digital holographic quantitative phase microscopy (DH-QPM) technique at the nanoscale particularly suitable for cell imaging. Particular emphasis is placed on the original biological information provided by the quantitative phase signal. We present the most relevant DH-QPM applications in the field of cell biology, including automated cell counts, recognition, classification, three-dimensional tracking, discrimination between physiological and pathophysiological states, and the study of cell membrane fluctuations at the nanoscale. In the last part, original results show how DH-QPM can address two important issues in the field of neurobiology, namely, multiple-site optical recording of neuronal activity and noninvasive visualization of dendritic spine dynamics resulting from a full digital holographic microscopy tomographic approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efficacy of optic nerve sheath decompression (ONSD) in treating non-arteritic ischemic optic neuropathy (NAION) is not clear. We retrospectively analyzed the records of 91 patients with NAION, who were examined during a two-year period, and compared the final Snellen visual acuities of eyes treated with ONSD with those of eyes that did not have surgery. Seven of 18 eyes with ONSD (39%) demonstrated increased visual acuity of two or more lines; whereas 23 of 71 eyes without surgery (32%) had increased acuity. The ONSD group and no surgery group were further subdivided into eyes with progressive visual loss and nonprogressive visual loss. No statistically significant differences in visual outcome between groups were found. We did not find the high frequency of visual improvement that has been reported in some studies of ONSD for NAION.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative method based on the detectability index (d') calculated for a non-prewhitened model observer with an eye filter (NPWE). The detectability index was calculated from the normalized noise power spectrum and image contrast, both measured from an image of a 5 cm poly(methyl methacrylate) phantom containing a 0.2 mm thick aluminium square, and the pre-sampling modulation transfer function. This was performed as a function of air kerma at the detector for 11 different digital mammography systems. These calculated d' values were compared against threshold gold thickness (T) results measured with the CDMAM test object and against derived theoretical relationships. A simple relationship was found between T and d', as a function of detector air kerma; a linear relationship was found between d' and contrast-to-noise ratio. The values of threshold thickness used to specify acceptable performance in the European Guidelines for 0.10 and 0.25 mm diameter discs were equivalent to threshold calculated detectability indices of 1.05 and 6.30, respectively. The NPWE method is a validated alternative to CDMAM scoring for use in the image quality specification, quality control and optimization of digital x-ray systems for screening mammography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.