108 resultados para Tachycardia, Ventricular
Resumo:
Patients with Ebstein's anomaly can present after childhood or adolescence with cyanosis, arrhythmias, severe right ventricular dysfunction and frequently with left ventricular dysfunction secondary to the prolonged cyanosis and to the right ventricular interference. At this point conventional repair is accompanied by elevated mortality and morbidity and poor functional results. We report our experience with three patients (8, 16 and 35 years of age) with Ebstein's anomaly, very dilated right atrium, severe tricuspid valve regurgitation (4/4), bi-directional shunt through an atrial septal defect and reduced left ventricular function (mean ejection fraction = 58%, mean shortening fraction = 25%). All underwent one and a half ventricular repair consisting of closure of the atrial septal defect, tricuspid repair with reduction of the atrialised portion of the right ventricle and end-to-side anastomosis of the superior vena cava to the right pulmonary artery. All patients survived, with a mean follow-up of 33 months. In all there was complete regression of the cyanosis and of the signs of heart failure. Postoperative echocardiography showed reduced degree of tricuspid regurgitation (2/4) and improvement of the left ventricular function (mean ejection fraction = 77%, mean shortening fraction = 40%). In patients with Ebstein's anomaly referred late for surgery with severely compromised right ventricular function or even with reduced biventricular function, the presence of a relatively hypoplastic and/or malfunctioning right ventricular chamber inadequate to sustain the entire systemic venous return but capable of managing part of the systemic venous return, permits a one and a half ventricular repair with good functional results.
Resumo:
Objective: Tachycardia is associated with hypertension and is a predictor of cardiovascular events. The predictive effect of tachycardia might reflect its connection with hypertension. In this analysis of 15,245 VALUE study patients we explore whether tachycardia predicts cardiovascular endpoints in high risk hypertension and whether the in-trial blood pressure lowering modified the tachycardia - related risk. Methods: Heart rate from ECG readings at baseline and annually throughout the trial. Results: In the Cox Regression analysis the primary endpoint hazard ratio for a 10 beats per minute increment of baseline heart rate was 1.16 (1.12-1.2) p < 0.0001, 1.17 (1.13-1.22) p < 0.0001 and 1.22 (1.18-1.27) p < 0.0001 unadjusted, adjusted for baseline blood pressure and for blood pressure plus risk factors, respectively. Primary endpoints strikingly increased in the highest quintile of baseline heart rate (=/>79 beats). Primary endpoints in the highest heart rate quintile were 30 % higher in first, 55 % in second, 55 % in third, 52 % in fourth and 46 % in the fifth year of the study. The in-trial heart rate was also a potent predictor. The primary endpoint hazard ratios of highest heart rate quintile versus pooled lower 4 quintiles was (1.34-1.66) p < 0.0001 unadjusted, 1.52 (1.36-1.69) p <0.0001 adjusted for baseline blood pressure and risk factors and 1.52 (1.36-1.69) p < 0.0001 further adjusted for in trial pressure. The increase of primary events in the upper quintile of in-trial heart rate was 68% in the group with good and 63% in the group with inadequate blood pressure control (both p < 0.0001 by log rank test). Conclusions: 1./ Tachycardia is a short term marker and a long term predictor of adverse event in high risk hypertension. 2./ Tachycardia contributes to the residual cardiovascular risk regardless of the degree of BP control. We hypothesize heart rate lowering with appropriate drugs may further decrease the cardiovascular risk in patients with high risk hypertension and tachycardia.
Resumo:
Les systèmes d'assistance ventriculaire sont apparus durant la dernière décade comme une approche thérapeutique efficace du traitement de l'insuffisance cardiaque terminale, en particulier dans le contexte de manque de donneurs d'organes. Néanmoins, et ceci malgré les progrès techniques majeurs, les taux de complications restent élevés et sont en partie liés à la configuration géométrique, en particulier le site d'implantation de la cannule de sortie à l'aorte thoracique. Bien que l'anastomose à l'aorte descendante permette une chirurgie moins invasive, les bénéfices de cette technique sont toujours controversés, comparée à la méthode standard de l'aorte ascendante, en raison du risque thrombo-embolique possiblement augmenté et des modifications hémodynamiques induites au niveau de l'arc aortique. Dans ce travail, nous comparons in silico en terme de débit et pression les deux possibilités anastomotiques. Nous développons un réseau de modèles mathématiques unidimensionnels, et l'appliquons à diverses situations cliniques, pour différents stades d'insuffisance cardiaque et de vitesses de rotation de la machine. Les données initiales sont obtenues grâce à un modèle OD (c'est-à-dire qui dépend uniquement du temps mais pas de l'espace) du système cardiovasculaire comprenant une assistance circulatoire, validé avec des données cliniques. Les simulations réalisées montrent que les deux méthodes sont similaires, en terme de débit et courbes de pression, ceci pour tous les cas cliniques étudiés. Ces résultats numériques soutiennent la possibilité d'utiliser la technique d'anastomose à l'aorte thoracique descendante, permettant une chirurgie moins invasive. Sur un plan plus fondamental, le système cardiovasculaire peut être simulé par le biais de multiples modèles de niveau de complexité différents, au prix d'un coût computationnel toujours plus élevé. Nous évaluons les avantages de modèles géométriques à plusieurs échelles (uni- et tridimensionnelle) avec données provenant de patients, comparés à des modèles simplifiés. Les résultats montrent que ces modèles de dimensions hétérogènes apportent un bénéfice important en terme de ressources de calcul, tout en conservant une précision acceptable. En conclusion, ces résultats encourageant montrent la relevance des études numériques dans le domaine médical, tant sur le plan fondamental et la compréhension des mécanismes physiopathologiques, que sur le plan applicatif et le développement de nouvelles thérapeutiques.
Resumo:
Background: Graft right ventricular (RV) function is compromised directly posttransplant, especially in heart transplantation (HTx) recipients with pretransplant pulmonary hypertension (PH). Graft RV size and systolic function, and the effect of the recipient's pulmonary haemodynamics on the graft extracellular matrix are not well characterised in the patients long-term after HTx. Aim: Comparison of RV size and systolic function in HTx recipients' long-term posttransplant stratified by the presence of pretransplant PH. Methods: HTx survivors >/=2 years posttransplant were divided into group I without pretransplant PH (pulmonary vascular resistance, PVR <2.5Wood units, n=37) and group II with PH (PVR >/=2.5Wood units, n=16). RV size and systolic function were measured using cardiac magnetic resonance imaging (CMR). The collagen content was assessed in septal endomyocardial biopsies obtained at HTx and at study inclusion. Results: Mean posttransplant follow-up was 5.2+/-2.9 years (group I) and 4.9+/-2.2 years (group II) (p=0.70). PVR was 1.5+/-0.6 vs 4.1+/-1.7Wood units pretransplant (p<0.001), and 1.2+/-0.5 vs 1.3+/-0.5Wood units at study inclusion (p=0.43). Allograft RV size and systolic function were similar in both groups (p always >/=0.07). Collagen content at transplantation and at follow-up were not different (p always >/=0.60). Conclusion: Posttransplant normalisation of pretransplant PH is associated with normal graft RV function long-term after HTx.
Resumo:
Objective: Previous studies reported on the association of left ventricular mass index (LVMI) with urinary sodium or with circulating or urinary aldosterone.We investigated the independent associations of LVMI with the urinary excretion of both sodium and aldosterone. Design and method: We randomly recruited 317 untreated subjects from a White population (45.1%women; mean age 48.2 years).Measurements included echocardiographic left ventricular (LV) properties, the 24 h urinary excretion of sodium and aldosterone, plasma renin activity (PRA), and proximal (RNaprox) and distal (RNadist) renal sodium reabsorption, assessed fromthe endogenous lithium clearance. Inmultivariable-adjusted models,we expressed changes in LVMI per 1 SD increase in the explanatory variables, while accounting for sex, age, systolic blood pressure and the waist-to-hip ratio. Results: LVMI increased independentlywith the urinary excretion of both sodium (+2.48 g/m2; P=0.005) and aldosterone (+2.63 g/m2; P=0.004). Higher sodium excretion was associated with increased mean wall thickness (MWT: +0.126 mm, P=0.054), but with no change in LV end-diastolic diameter (LVID: +0.12mm, P=0.64). In contrast, higher aldosterone excretion was associated with higher LVID (+0.54 mm; P=0.017), but with no change in MWT (+0.070mm; P=0.28).Higher RNadistwas associatedwith lower relativewall thickness (−0.81×10−2, P=0.017), because of opposite trends in LVID(+0.33 mm; P=0.13) and MWT (−0.130mm; P=0.040). LVMI was not associated with PRA or RNaprox. Conclusions: LVMI independently increased with both urinary sodium and aldosterone excretion. IncreasedMWT explained the association of LVMI with urinary sodium and increased LVID the association of LVMI with urinary aldosterone.
Resumo:
AIMS: Diabetes in pregnant women is increasing and with that the complications in their offspring. We studied our population of diabetic mothers (2003-2005) for pathologic ventricular hypertrophy (PVH). METHODS AND RESULTS: In our retrospective study of all 87 diabetic pregnancies (92 neonates), 16 were type 1, 17 were type 2, and 54 were gestational diabetes (GD). Haemoglobin glycated (HbA1c) median was 5.8% (5.3-6.5): 17 with HbA1c above normal 2 with congenital heart disease (CHD) and six with PVH. A total of 75 neonates were normal, five had CHD, and 12 had PVH (1/12 died post-natally, 1/12 stillborn, 2/12 required premature delivery, 8/12 normal). The 16 type 1 pregnancies resulted in three neonates with CHD and in 50% PVH, including one death, one premature Cesarean section because of PVH. The 17 neonates of type 2 pregnancies showed in one CHD and in 25% PVH. Of the 54 GD pregnancies, one had CHD and one had PVH. CONCLUSION: Pregnancies of both type 1 and 2 diabetes carry an increased risk for foetal development of PVH compared with those with GD. The insufficient effect of preventive glycaemia controls leads to conclude that although no definite predictive parameters for malignant outcome can be presented, close monitoring of these pregnancies may prevent perinatal catastrophes.
Resumo:
An implantable cardiac defibrillator (ICD) is a cardiac implantable electronic device that is capable of identifying and treating ventricular arrhythmias. Consideration about the type of ICD to select for a given patient include whether the patient has bradycardia requiring pacing support, has associated atrial tachyarrhythmias, or would benefit from cardiac resynchronization therapy. The ICD functions by continuously monitoring the patient's cardiac rate and delivering therapies (anti-tachycardia pacing, shocks) when the rate exceeds the programmed rate "cutoff". Secondary prevention trials have demonstrated that ICDs reduce the incidence of arrhythmic death and total mortality in patients presenting with a cardiac arrest. ICDs are also indicated for primary prevention of sudden cardiac death in specific high-risk subgroups of patients.
Resumo:
Introduction: We recently observed in a chronic ovine model that a shortening of action potential duration (APD) as assessed by the activation recovery interval (ARI) may be a mechanism whereby pacing-induced atrial tachycardia (PIAT) facilitates atrial fibrillation (AF), mediated by a return to 1:1 atrial capture after the effective refractory period has been reached. The aim of the present study is to evaluate the effect of long term intermittent burst pacing on ARI before induction of AF.Methods: We specifically developed a chronic ovine model of PIAT using two pacemakers (PM) each with a right atrial (RA) lead separated by ∼2cm. The 1st PM (Vitatron T70) was used to record a broadband unipolar RA EGM (800 Hz, 0.4 Hz high pass filter). The 2nd was used to deliver PIAT during electrophysiological protocols at decremental pacing CL (400 beats, from 400 to 110ms) and long term intermittent RA burst pacing to promote electrical remodeling (5s of burst followed by 2s of sinus rhythm) until onset of sustained AF. ARI was defined as the time difference between the peak of the atrial repolarization wave and the first atrial depolarization. The mean ARIs of paired sequences (before and after remodeling), each consisting of 20 beats were compared.Results: As shown in the figure, ARIs (n=4 sheep, 46 recordings) decreased post remodeling compared to baseline (86±19 vs 103±12 ms, p<0.05). There was no difference in atrial structure as assessed by light microscopy between control and remodeled sheep.Conclusions: Using standard pacemaker technology, atrial ARIs as a surrogate of APDs were successfully measured in vivo during the electrical remodeling process leading to AF. The facilitation of AF by PIAT mimicking salvos from pulmonary veins is heralded by a significant shortening of ARI.
Resumo:
BACKGROUND: Recent data suggest that beta-blockers can be beneficial in subgroups of patients with chronic heart failure (CHF). For metoprolol and carvedilol, an increase in ejection fraction has been shown and favorable effects on the myocardial remodeling process have been reported in some studies. We examined the effects of bisoprolol fumarate on exercise capacity and left ventricular volume with magnetic resonance imaging (MRI) and applied a novel high-resolution MRI tagging technique to determine myocardial rotation and relaxation velocity. METHODS: Twenty-eight patients (mean age, 57 +/- 11 years; mean ejection fraction, 26 +/- 6%) were randomized to bisoprolol fumarate (n = 13) or to placebo therapy (n = 15). The dosage of the drugs was titrated to match that of the the Cardiac Insufficiency Bisoprolol Study protocol. Hemodynamic and gas exchange responses to exercise, MRI measurements of left ventricular end-systolic and end-diastolic volumes and ejection fraction, and left ventricular rotation and relaxation velocities were measured before the administration of the drug and 6 and 12 months later. RESULTS: After 1 year, heart rate was reduced in the bisoprolol fumarate group both at rest (81 +/- 12 before therapy versus 61 +/- 11 after therapy; P <.01) and peak exercise (144 +/- 20 before therapy versus 127 +/- 17 after therapy; P <.01), which indicated a reduction in sympathetic drive. No differences were observed in heart rate responses in the placebo group. No differences were observed within or between groups in peak oxygen uptake, although work rate achieved was higher (117.9 +/- 36 watts versus 146.1 +/- 33 watts; P <.05) and exercise time tended to be higher (9.1 +/- 1.7 minutes versus 11.4 +/- 2.8 minutes; P =.06) in the bisoprolol fumarate group. A trend for a reduction in left ventricular end-diastolic volume (-54 mL) and left ventricular end-systolic volume (-62 mL) in the bisoprolol fumarate group occurred after 1 year. Ejection fraction was higher in the bisoprolol fumarate group (25.0 +/- 7 versus 36.2 +/- 9%; P <.05), and the placebo group remained unchanged. Most changes in volume and ejection fraction occurred during the latter 6 months of treatment. With myocardial tagging, insignificant reductions in left ventricular rotation velocity were observed in both groups, whereas relaxation velocity was reduced only after bisoprolol fumarate therapy (by 39%; P <.05). CONCLUSION: One year of bisoprolol fumarate therapy resulted in an improvement in exercise capacity, showed trends for reductions in end-diastolic and end-systolic volumes, increased ejection fraction, and significantly reduced relaxation velocity. Although these results generally confirm the beneficial effects of beta-blockade in patients with chronic heart failure, they show differential effects on systolic and diastolic function.
Resumo:
BACKGROUND: Determining a specific death cause may facilitate individualized therapy in patients with heart failure (HF). Cardiac resynchronization therapy (CRT) decreased mortality in the Cardiac Resynchronization in Heart Failure trial by reducing pump failure and sudden cardiac death (SCD). This study analyzes predictors of specific causes of death. METHODS AND RESULTS: Univariate and multivariate analyses used 8 baseline and 3-month post-randomization variables to predict pump failure and SCD (categorized as "definite," "probable," and "possible"). Of 255 deaths, 197 were cardiovascular. There were 71 SCDs with a risk reduction by CRT of 0.47 (95% confidence interval 0.29-0.76; P = .002) with similar reductions in SCD classified as definite, probable, and possible. Univariate SCD predictors were 3-month HF status (mitral regurgitation [MR] severity, plasma brain natriuretic peptide [BNP], end-diastolic volume, and systolic blood pressure), whereas randomization to CRT decreased risk. Multivariate SCD predictors were randomization to CRT 0.56 (0.53-0.96, P = .035) and 3-month MR severity 1.82 (1.77-2.60, P = .0012). Univariate pump failure death predictors related to baseline HF state (quality of life score, interventricular mechanical delay, end-diastolic volume, plasma BNP, MR severity, and systolic pressure), whereas randomization to CRT and nonischemic cardiomyopathy decreased risk; multivariate predictors of pump failure death were baseline plasma BNP and systolic pressure and randomization to CRT. CONCLUSION: CRT decreased SCD in patients with systolic HF and ventricular dyssynchrony. SCD risk was increased with increased severity of MR (including the 3-month value for MR as a time-dependent covariate) and reduced by randomization to CRT. HF death was increased related to the level of systolic blood pressure, log BNP, and randomization to CRT. These results emphasize the importance and interdependence of HF severity to mortality from pump failure and SCD.
Resumo:
Zebrafish and Xenopus have become popular model organisms for studying vertebrate development of many organ systems, including the heart. However, it is not clear whether the single ventricular hearts of these species possess any equivalent of the specialized ventricular conduction system found in higher vertebrates. Isolated hearts of adult zebrafish (Danio rerio) and African toads (Xenopus laevis) were stained with voltage-sensitive dye and optically mapped in spontaneous and paced rhythms followed by histological examination focusing on myocardial continuity between the atrium and the ventricle. Spread of the excitation wave through the atria was uniform with average activation times of 20 +/- 2 and 50 +/- 2 ms for zebrafish and Xenopus toads, respectively. After a delay of 47 +/- 8 and 414 +/- 16 ms, the ventricle became activated first in the apical region. Ectopic ventricular activation was propagated significantly more slowly (total ventricular activation times: 24 +/- 3 vs. 14 +/- 2 ms in zebrafish and 74 +/- 14 vs. 35 +/- 9 ms in Xenopus). Although we did not observe any histologically defined tracts of specialized conduction cells within the ventricle, there were trabecular bands with prominent polysialic acid-neural cell adhesion molecule staining forming direct myocardial continuity between the atrioventricular canal and the apex of the ventricle; i.e., the site of the epicardial breakthrough. We thus conclude that these hearts are able to achieve the apex-to-base ventricular activation pattern observed in higher vertebrates in the apparent absence of differentiated conduction fascicles, suggesting that the ventricular trabeculae serve as a functional equivalent of the His-Purkinje system.
Resumo:
OBJECTIVES: Current indications for therapeutic hypothermia (TH) are restricted to comatose patients with cardiac arrest (CA) due to ventricular fibrillation (VF) and without circulatory shock. Additional studies are needed to evaluate the benefit of this treatment in more heterogeneous groups of patients, including those with non-VF rhythms and/or shock and to identify early predictors of outcome in this setting. DESIGN: Prospective study, from December 2004 to October 2006. SETTING: 32-bed medico-surgical intensive care unit, university hospital. PATIENTS: Comatose patients with out-of-hospital CA. INTERVENTIONS: TH to 33 +/- 1 degrees C (external cooling, 24 hrs) was administered to patients resuscitated from CA due to VF and non-VF (including asystole or pulseless electrical activity), independently from the presence of shock. MEASUREMENTS AND MAIN RESULTS: We hypothesized that simple clinical criteria available on hospital admission (initial arrest rhythm, duration of CA, and presence of shock) might help to identify patients who eventually survive and might most benefit from TH. For this purpose, outcome was related to these predefined variables. Seventy-four patients (VF 38, non-VF 36) were included; 46% had circulatory shock. Median duration of CA (time from collapse to return of spontaneous circulation [ROSC]) was 25 mins. Overall survival was 39.2%. However, only 3.1% of patients with time to ROSC > 25 mins survived, as compared to 65.7% with time to ROSC < or = 25 mins. Using a logistic regression analysis, time from collapse to ROSC, but not initial arrest rhythm or presence of shock, independently predicted survival at hospital discharge. CONCLUSIONS: Time from collapse to ROSC is strongly associated with outcome following VF and non-VF cardiac arrest treated with therapeutic hypothermia and could therefore be helpful to identify patients who benefit most from active induced cooling.
Resumo:
It has not been well established whether the mechanisms participating in pH regulation in the anoxic-reoxygenated developing myocardium resemble those operating in the adult. We have specially examined the importance of Na+/H+ exchange (NHE) and HCO3-dependent transports in cardiac activity after changes in extracellular pH (pHo). Spontaneously contracting hearts isolated from 4-day-old chick embryos were submitted to single or repeated anoxia (1 min) followed by reoxygenation (10 min). The chronotropic, dromotropic and inotropic responses of the hearts were determined in standard HCO3- buffer at pHo 7.4 and at pHo 6.5 (hypercapnic acidosis). In distinct experiments, acidotic anoxia preceded reoxygenation at pHo 7.4. NHE was blocked with amiloride derivative HMA (1 micro mol/l) and HCO3-dependent transports were inactivated by replacement of HCO3 or blockade with stilbene derivative DIDS (100 micro mol/l). Anoxia caused transient tachycardia, depressed mechanical function and induced contracture. Reoxygenation temporarily provoked cardiac arrest, atrio-ventricular (AV) block, arrhythmias and depression of contractility. Addition of DIDS or substitution of HCO3 at pHo 7.4 had the same effects as acidosis per se, i.e. shortened contractile activity and increased incidence of arrhythmias during anoxia, prolonged cardioplegia and provoked arrhythmias at reoxygenation. Under anoxia at pHo 6.5/reoxygenation at pHo 7.4, cardioplegia, AV block and arrhythmias were all markedly prolonged. Interestingly, in the latter protocol, DIDS suppressed AV block and arrhythmias during reoxygenation, whereas HMA had no effect. Thus, intracellular pH regulation in the anoxic-reoxygenated embryonic heart appears to depend predominantly on HCO3 availability and transport. Furthermore, pharmacological inhibition of anion transport can protect against reoxygenation-induced dysfunction.
Resumo:
Objective: Existing VADs are single-ventricle pumps needing anticoagulation. We developed a bi ventricular external assist device that reproduces the physiological heart muscle movement completely avoiding anticoagulants. Methods: The device has a carbon fibre skeleton fitting a 30-40 kg patient's heart, to which a Nitinol based artificial muscle is connected. The artificial muscle wraps both ventricles. The strength of the Nitinol fibres is amplified by a pivot articulation in contact with the ventricle wall. The fibres are electrically driven and a dedicated control unit has been developed. We assessed hemodynamic performances of this device using a previously described dedicated bench test. Volume ejected and pressure gradient has been measured with afterload ranging from 25 to 50mmHg. Results: With anafterload of 50mmHg the system has an ejection fraction (EF) of 10% on the right side and 8% on the left side. The system is able to generate a systolic ejection of 5,5 ml on the right side and 4,4 ml on the left side. With anafterload of 25mmHg the results are reduced of about 20%. The activation frequency is 80/minute resulting in a total volume displacement of 440 ml/minute on the right side and 352 ml/minute on the left side. Conclusions: The artificial muscle follows Starling's law as the ejected volume increases when afterload increases. These preliminary studies confirmed the possibility of improving the EF of a failing heart using artificial muscle for external cardiac compression. This device could be helpful in weaning CPB and/or for short-term cardio-circulatory support in paediatric population with cardiac failure.