195 resultados para Symbolism in medicine.
Resumo:
OBJECTIVE: To investigate the prevalence of discontinuation and nonpublication of surgical versus medical randomized controlled trials (RCTs) and to explore risk factors for discontinuation and nonpublication of surgical RCTs. BACKGROUND: Trial discontinuation has significant scientific, ethical, and economic implications. To date, the prevalence of discontinuation of surgical RCTs is unknown. METHODS: All RCT protocols approved between 2000 and 2003 by 6 ethics committees in Canada, Germany, and Switzerland were screened. Baseline characteristics were collected and, if published, full reports retrieved. Risk factors for early discontinuation for slow recruitment and nonpublication were explored using multivariable logistic regression analyses. RESULTS: In total, 863 RCT protocols involving adult patients were identified, 127 in surgery (15%) and 736 in medicine (85%). Surgical trials were discontinued for any reason more often than medical trials [43% vs 27%, risk difference 16% (95% confidence interval [CI]: 5%-26%); P = 0.001] and more often discontinued for slow recruitment [18% vs 11%, risk difference 8% (95% CI: 0.1%-16%); P = 0.020]. The percentage of trials not published as full journal article was similar in surgical and medical trials (44% vs 40%, risk difference 4% (95% CI: -5% to 14%); P = 0.373). Discontinuation of surgical trials was a strong risk factor for nonpublication (odds ratio = 4.18, 95% CI: 1.45-12.06; P = 0.008). CONCLUSIONS: Discontinuation and nonpublication rates were substantial in surgical RCTs and trial discontinuation was strongly associated with nonpublication. These findings need to be taken into account when interpreting surgical literature. Surgical trialists should consider feasibility studies before embarking on full-scale trials.
Resumo:
UNLABELLED: Phenomenon: Assuring quality medical care for all persons requires that healthcare providers understand how sociocultural factors affect a patient's health beliefs/behaviors. Switzerland's changing demographics highlight the importance of provider cross-cultural preparedness for all patients-especially those at risk for social/health precarity. We evaluated healthcare provider cross-cultural preparedness for commonly encountered vulnerable patient profiles. APPROACH: A survey on cross-cultural care was mailed to Lausanne University hospital's "front-line healthcare providers": clinical nurses and resident physicians at our institution. Preparedness items asked "How prepared do you feel to care for ... ?" (referring to example patient profiles) on an ascending 5-point Likert scale. We examined proportions of "4 - well/5 - very well prepared" and the mean composite score for preparedness. We used linear regression to examine the adjusted effect of demographics, work context, cultural-competence training, and cross-cultural care problem awareness, on preparedness. FINDINGS: Of 885 questionnaires, 368 (41.2%) were returned: 124 (33.6%) physicians and 244 (66.4%) nurses. Mean preparedness composite was 3.30 (SD = 0.70), with the lowest proportion of healthcare providers feeling prepared for patients "whose religious beliefs affect treatment" (22%). After adjustment, working in a sensitized department (β = 0.21, p = .01), training on the history/culture of a specific group (β = 0.25, p = .03), and awareness regarding (a) a lack of practical experience caring for diverse populations (β = 0.25, p = .004) and (b) inadequate cross-cultural training (β = 0.18, p = .04) were associated with higher preparedness. Speaking French as a dominant language and physician role (vs. nurse) were negatively associated with preparedness (β = -0.26, p = .01; β = -0.22, p = .01). Insights: The state of cross-cultural care preparedness among Lausanne's front-line healthcare providers leaves room for improvement. Our study points toward institutional strategies to improve preparedness: notably, making sure departments are sensitized to cross-cultural care resources and increasing provider diversity to reflect the changing Swiss demographic.
Resumo:
Mapping the microstructure properties of the local tissues in the brain is crucial to understand any pathological condition from a biological perspective. Most of the existing techniques to estimate the microstructure of the white matter assume a single axon orientation whereas numerous regions of the brain actually present a fiber-crossing configuration. The purpose of the present study is to extend a recent convex optimization framework to recover microstructure parameters in regions with multiple fibers.
Resumo:
NlmCategory="UNASSIGNED">A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.
Resumo:
PURPOSE: To introduce a new k-space traversal strategy for segmented three-dimensional echo planar imaging (3D EPI) that encodes two partitions per radiofrequency excitation, effectively reducing the number excitations used to acquire a 3D EPI dataset by half. METHODS: The strategy was evaluated in the context of functional MRI applications for: image quality compared with segmented 3D EPI, temporal signal-to-noise ratio (tSNR) (the ability to detect resting state networks compared with multislice two-dimensional (2D) EPI and segmented 3D EPI, and temporal resolution (the ability to separate cardiac- and respiration-related fluctuations from the desired blood oxygen level-dependent signal of interest). RESULTS: Whole brain images with a nominal voxel size of 2 mm isotropic could be acquired with a temporal resolution under half a second using traditional parallel imaging acceleration up to 4× in the partition-encode direction and using novel data acquisition speed-up of 2× with a 32-channel coil. With 8× data acquisition speed-up in the partition-encode direction, 3D reduced excitations (RE)-EPI produced acceptable image quality without introduction of noticeable additional artifacts. Due to increased tSNR and better characterization of physiological fluctuations, the new strategy allowed detection of more resting state networks compared with multislice 2D-EPI and segmented 3D EPI. CONCLUSION: 3D RE-EPI resulted in significant increases in temporal resolution for whole brain acquisitions and in improved physiological noise characterization compared with 2D-EPI and segmented 3D EPI. Magn Reson Med 72:786-792, 2014. © 2013 Wiley Periodicals, Inc.
Resumo:
Fall prevention in elderly subjects is often based on training and rehabilitation programs that include mostly traditional balance and strength exercises. By applying such conventional interventions to improve gait performance and decrease fall risk, some important factors are neglected such as the dynamics of the gait and the motor learning processes. The EU project "Self Mobility Improvement in the eLderly by counteractING falls" (SMILING project) aimed to improve age-related gait and balance performance by using unpredicted external perturbations during walking through motorized shoes that change insole inclination at each stance. This paper describes the shoe-worn inertial module and the gait analysis method needed to control in real-time the shoe insole inclination during training, as well as gait spatio-temporal parameters obtained during long distance walking before and after the 8-week training program that assessed the efficacy of training with these motorized shoes.
Resumo:
This work explores a concept for motion detection in brain MR examinations using high channel-count RF coil arrays. It applies ultrashort (<100 μsec) free induction decay signals, making use of the knowledge that motion induces variations in these signals when compared to a reference free induction decay signal. As a proof-of-concept, the method was implemented in a standard structural MRI sequence. The stability of the free induction decay-signal was verified in phantom experiments. Human experiments demonstrated that the observed variations in the navigator data provide a sensitive measure for detection of relevant and common subject motion patterns. The proposed methodology provides a means to monitor subject motion throughout a MRI scan while causing little or no impact on the sequence timing and image contrast. It could hence complement available motion detection and correction methods, thus further reducing motion sensitivity in MR applications.
Resumo:
A technique for fast imaging of regional myocardial function using a spiral acquisition in combination with strain-encoded (SENC) magnetic resonance imaging (MRI) is presented in this paper. This technique, which is termed fast-SENC, enables scan durations as short as a single heartbeat. A reduced field of view (FOV) without foldover artifacts was achieved by localized SENC, which selectively excited the region around the heart. The two images required for SENC imaging (low- and high-tuning) were acquired in an interleaved fashion throughout the cardiac cycle to further shorten the scan time. Regional circumferential contraction and longitudinal shortening of both the left ventricle (LV) and right ventricle (RV) were examined in long- and short-axis views, respectively. The in vivo results obtained from five human subjects and five infarcted dogs are presented. The results of the fast-SENC technique in a single heartbeat acquisition were comparable to those obtained by conventional SENC in a long acquisition time. Therefore, fast-SENC may prove useful for imaging during stress or arrhythmia.
Resumo:
PURPOSE: Corticosteroids have recorded beneficial clinical effects and are widely used in medicine. In ophthalmology, besides their treatment benefits, side effects, including ocular toxicity have been observed especially when intraocular delivery is used. The mechanism of these toxic events remains, however, poorly understood. In our present study, we investigated the mechanisms and potential pathways of corticosteroid-induced retinal cell death. METHODS: Rats were sacrificed 24 h and 8 days after an intravitreous injection of 1 microl (40 microg) of Kenacort Retard. The eyes were processed for ultra structure analysis and detection of activated caspase-3, cytochrome-C, apoptosis-inducing factor (AIF), LEI-L-Dnase II, terminal transferase dUTP nick end labeling (TUNEL), and microtubule-associated protein 1-light chain 3 (MAP-LC3). In vitro, rat retinal pigment epithelial cells (RPE), retinal Müller glial cells (RMG) and human ARPE-19 cells were treated with triamcinolone acetonide (TA) or other glucocorticoids. Cell viability was quantified by 3-(4,5-dimethylthiazol-2-yl)-2,5 phenyltetrazolium bromide test (MTT) assay and cell counts. Nuclei staining, TUNEL assay, annexin-V binding, activated caspase-3 and lactate dehydrogenase (LDH) production characterized cell death. Localization of cytochrome-C, AIF, LEI-and L-Dnase II, and staining with MAP-LC3 or monodansylcadaverine were also carried out. Finally, ARPE-19 cells transfected with AIP-1/Alix were exposed to TA. RESULTS: In vitro incubation of retinal cell in the presence of corticosteroids induced a specific and dose-dependent reduction of cell viability. These toxic events were not associated with the anti-inflammatory activity of these compounds but depended on the hydro solubility of their formulation. Before cell death, extensive cytoplasmic vacuolization was observed in the retinal pigment epithelial (RPE) cells in vivo and in vitro. The cells however, did not show known caspase-dependent or caspase-independent apoptotic reactions. These intracellular vacuoles were negative for MAP-LC3 but some stained positive for monodansylcadaverine. Furthermore, over expression of AIP-1/Alix inhibited RPE cell death. CONCLUSIONS: These observations suggest that corticosteroid-induced retinal cell death may be carried out mainly through a paraptosis pathway.
Resumo:
Recently, the spin-echo full-intensity acquired localized (SPECIAL) spectroscopy technique was proposed to unite the advantages of short TEs on the order of milliseconds (ms) with full sensitivity and applied to in vivo rat brain. In the present study, SPECIAL was adapted and optimized for use on a clinical platform at 3T and 7T by combining interleaved water suppression (WS) and outer volume saturation (OVS), optimized sequence timing, and improved shimming using FASTMAP. High-quality single voxel spectra of human brain were acquired at TEs below or equal to 6 ms on a clinical 3T and 7T system for six volunteers. Narrow linewidths (6.6 +/- 0.6 Hz at 3T and 12.1 +/- 1.0 Hz at 7T for water) and the high signal-to-noise ratio (SNR) of the artifact-free spectra enabled the quantification of a neurochemical profile consisting of 18 metabolites with Cramér-Rao lower bounds (CRLBs) below 20% at both field strengths. The enhanced sensitivity and increased spectral resolution at 7T compared to 3T allowed a two-fold reduction in scan time, an increased precision of quantification for 12 metabolites, and the additional quantification of lactate with CRLB below 20%. Improved sensitivity at 7T was also demonstrated by a 1.7-fold increase in average SNR (= peak height/root mean square [RMS]-of-noise) per unit-time.
Resumo:
The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).
Resumo:
The 2009 news in medicine regarding dependence confirm the bio-psycho-social field of addiction medicine and psychiatry. First a statement is made about the risk of cardiac arythmy in opioid substitution treatments. Then a review of the treatment of C hepatitis shows its importance in an addicted population. In the field of cognitive neuroscience, progress has been made in the knowledge of "craving" and of its endophenotypical components. Electronic medias related disorders are on the border of addiction: a case study is exploring this new domain. At last, recent datas are presented on the relationship between cannabis and psychosis. Les nouveautés en médecine 2009 concernant les dépendances confirment l'étendue du champ bio-psychosocial de la médecine et de la psychiatrie de l'addiction. Tout d'abord un point de situation est fait sur le risque d'arythmie cardiaque dans les traitements de substitution opiacée. Puis une revue de l'actualité du traitement de l'hépatite C dans la toxicodépendance en montre la pertinence. Sur le plan de la recherche plus fondamentale, les neurosciences cognitives progressent dans l'approche de la nature du craving et de ses composantes endophénotypiques. Les troubles liés aux médias électroniques illustrent les frontières de l'addiction : une étude de cas vient en explorer le contenu. Enfin, des données récentes sur les rapports entre cannabis et psychoses sont présentées.