95 resultados para Strong comparison principle
Resumo:
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.
Resumo:
The response of Arabidopsis to stress caused by mechanical wounding was chosen as a model to compare the performances of high resolution quadrupole-time-of-flight (Q-TOF) and single stage Orbitrap (Exactive Plus) mass spectrometers in untargeted metabolomics. Both instruments were coupled to ultra-high pressure liquid chromatography (UHPLC) systems set under identical conditions. The experiment was divided in two steps: the first analyses involved sixteen unwounded plants, half of which were spiked with pure standards that are not present in Arabidopsis. The second analyses compared the metabolomes of mechanically wounded plants to unwounded plants. Data from both systems were extracted using the same feature detection software and submitted to unsupervised and supervised multivariate analysis methods. Both mass spectrometers were compared in terms of number and identity of detected features, capacity to discriminate between samples, repeatability and sensitivity. Although analytical variability was lower for the UHPLC-Q-TOF, generally the results for the two detectors were quite similar, both of them proving to be highly efficient at detecting even subtle differences between plant groups. Overall, sensitivity was found to be comparable, although the Exactive Plus Orbitrap provided slightly lower detection limits for specific compounds. Finally, to evaluate the potential of the two mass spectrometers for the identification of unknown markers, mass and spectral accuracies were calculated on selected identified compounds. While both instruments showed excellent mass accuracy (<2.5ppm for all measured compounds), better spectral accuracy was recorded on the Q-TOF. Taken together, our results demonstrate that comparable performances can be obtained at acquisition frequencies compatible with UHPLC on Q-TOF and Exactive Plus MS, which may thus be equivalently used for plant metabolomics.
Resumo:
Neutrality tests in quantitative genetics provide a statistical framework for the detection of selection on polygenic traits in wild populations. However, the existing method based on comparisons of divergence at neutral markers and quantitative traits (Q(st)-F(st)) suffers from several limitations that hinder a clear interpretation of the results with typical empirical designs. In this article, we propose a multivariate extension of this neutrality test based on empirical estimates of the among-populations (D) and within-populations (G) covariance matrices by MANOVA. A simple pattern is expected under neutrality: D = 2F(st)/(1 - F(st))G, so that neutrality implies both proportionality of the two matrices and a specific value of the proportionality coefficient. This pattern is tested using Flury's framework for matrix comparison [common principal-component (CPC) analysis], a well-known tool in G matrix evolution studies. We show the importance of using a Bartlett adjustment of the test for the small sample sizes typically found in empirical studies. We propose a dual test: (i) that the proportionality coefficient is not different from its neutral expectation [2F(st)/(1 - F(st))] and (ii) that the MANOVA estimates of mean square matrices between and among populations are proportional. These two tests combined provide a more stringent test for neutrality than the classic Q(st)-F(st) comparison and avoid several statistical problems. Extensive simulations of realistic empirical designs suggest that these tests correctly detect the expected pattern under neutrality and have enough power to efficiently detect mild to strong selection (homogeneous, heterogeneous, or mixed) when it is occurring on a set of traits. This method also provides a rigorous and quantitative framework for disentangling the effects of different selection regimes and of drift on the evolution of the G matrix. We discuss practical requirements for the proper application of our test in empirical studies and potential extensions.
Resumo:
Bacteria can survive on hospital textiles and surfaces, from which they can be disseminated, representing a source of health care-associated infections (HCAIs). Surfaces containing copper (Cu), which is known for its bactericidal properties, could be an efficient way to lower the burden of potential pathogens. The antimicrobial activity of Cu-sputtered polyester surfaces, obtained by direct-current magnetron sputtering (DCMS), against methicillin-resistant Staphylococcus aureus (MRSA) was tested. The Cu-polyester microstructure was characterized by high-resolution transmission electron microscopy to determine the microstructure of the Cu nanoparticles and by profilometry to assess the thickness of the layers. Sputtering at 300 mA for 160 s led to a Cu film thickness of 20 nm (100 Cu layers) containing 0.209% (wt/wt) polyester. The viability of MRSA strain ATCC 43300 on Cu-sputtered polyester was evaluated by four methods: (i) mechanical detachment, (ii) microcalorimetry, (iii) direct transfer onto plates, and (iv) stereomicroscopy. The low efficacy of mechanical detachment impeded bacterial viability estimations. Microcalorimetry provided only semiquantitative results. Direct transfer onto plates and stereomicroscopy seemed to be the most suitable methods to evaluate the bacterial inactivation potential of Cu-sputtered polyester surfaces, since they presented the least experimental bias. Cu-polyester samples sputtered for 160 s by DCMS were further tested against 10 clinical MRSA isolates and showed a high level of bactericidal activity, with a 4-log(10) reduction in the initial MRSA load (10(6) CFU) within 1 h. Cu-sputtered polyester surfaces might be of use to prevent the transmission of HCAI pathogens.
Resumo:
To compare autofluorescence (AF) images obtained with the confocal scanning laser ophthalmoscope (using the Heidelberg retina angiograph; HRA) and the modified Topcon fundus camera, in a routine clinical setting. A prospective comparative study conducted at the Jules-Gonin Eye Hospital. Fifty-six patients from the medical retina clinic. All patients had complete ophthalmic slit-lamp and fundus examinations, colour and red-free fundus photography, AF imaging with both instruments, and fluorescein angiography. Cataract and fixation were graded clinically. AF patterns were analyzed for healthy and pathological features. Differences of image noise were analyzed by cataract grading and fixation. A total of 105 eyes were included. AF patterns discovered by the retina angiograph and the fundus camera images, respectively, were a dark optic disc in 72 % versus 15 %, a dark fovea in 92 % versus 4 %, sub- and intraretinal fluid visible as hyperautofluorescence on HRA images only, lipid exudates visible as hypoautofluorescence on HRA images only. The same autofluorescent pattern was found on both images for geographic atrophy, retinal pigment changes, drusen and haemorrhage. Image noise was significantly associated with the degree of cataract and/or poor fixation, favouring the fundus camera. Images acquired by the fundus camera before and after fluorescein angiography were identical. Fundus AF images differ according to the technical differences of the instruments used. Knowledge of these differences is important not only for correctly interpreting images, but also for selecting the most appropriate instrument for the clinical situation.
Functional late outgrowth endothelial progenitors isolated from peripheral blood of burned patients.
Resumo:
BACKGROUND: Bioengineered skin substitutes are increasingly considered as a useful option for the treatment of full thickness burn injury. Their viability following grafting can be enhanced by seeding the skin substitute with late outgrowth endothelial progenitor cells (EPCs). However, it is not known whether autologous EPCs can be obtained from burned patients shortly after injury. METHODS: Late outgrowth EPCs were isolated from peripheral blood sampled obtained from 10 burned patients (extent 19.6±10.3% TBSA) within the first 24h of hospital admission, and from 7 healthy subjects. Late outgrowth EPCs were phenotyped in vitro. RESULTS: In comparison with similar cells obtained from healthy subjects, growing colonies from burned patients yielded a higher percentage of EPC clones (46 versus 17%, p=0.013). Furthermore, EPCs from burned patients secreted more vascular endothelial growth factor (VEGF) into the culture medium than did their counterparts from healthy subjects (85.8±56.2 versus 17.6±14pg/mg protein, p=0.018). When injected to athymic nude mice 6h after unilateral ligation of the femoral artery, EPCs from both groups of subjects greatly accelerated the reperfusion of the ischaemic hindlimb and increased the number of vascular smooth muscle cells. CONCLUSIONS: The present study supports that, in patients with burns of moderate extension, it is feasible to obtain functional autologous late outgrowth EPCs from peripheral blood. These results constitute a strong incentive to pursue approaches based on using autotransplantation of these cells to improve the therapy of full thickness burns.
Resumo:
OBJECTIVES: To assess whether patients' characteristics and healthcare resources consumption and costs were different between native and migrant populations in Switzerland. METHODS: All adult patients followed-up in the Swiss HIV-cohort study in our institution during 2000-2003 were considered. Patients' characteristics were retrieved from the cohort database. Hospital and outpatient resource use were extracted from individual charts and valued with 2002 tariffs. RESULTS: The 66 migrants were younger (29 +/- 8 years versus 37 +/- 11, p < 0.001), less often of male gender (38 % versus 70 %, p < 0.001), predominantly infected via heterosexual contact (87 % versus 52 %, p < 0.01), with lower mean CD4 level at enrollment (326 +/- 235 versus 437 +/- 305, p = 0.002) than their 200 native counterparts. Migrants had fewer hospitalizations, more frequent outpatient visits, laboratory tests, and lower total cost of care per year of follow-up (<euro> 2'215 +/- 4'206 versus 4'155 +/- 12'304, p = 0.037). Resource use and costs were significantly higher in people with < 200 CD4 cell counts in both groups. CONCLUSIONS: Migrant population had more advanced disease, more outpatient visits but less hospitalizations, resulting in lower costs of care when compared with native population.
Resumo:
OBJECTIVES: Skin notations are used as a hazard identification tool to flag chemicals associated with a potential risk related to transdermal penetration. The transparency and rigorousness of the skin notation assignment process have recently been questioned. We compared different approaches proposed as criteria for these notations as a starting point for improving and systematizing current practice. METHODS: In this study, skin notations, dermal acute lethal dose 50 in mammals (LD(50)s) and two dermal risk indices derived from previously published work were compared using the lists of Swiss maximum allowable concentrations (MACs) and threshold limit values (TLVs) from the American Conference of Governmental Industrial Hygienists (ACGIH). The indices were both based on quantitative structure-activity relationship (QSAR) estimation of transdermal fluxes. One index compared the cumulative dose received through skin given specific exposure surface and duration to that received through lungs following inhalation 8 h at the MAC or TLV. The other index estimated the blood level increase caused by adding skin exposure to the inhalation route at kinetic steady state. Dermal-to-other route ratios of LD(50) were calculated as secondary indices of dermal penetrability. RESULTS: The working data set included 364 substances. Depending on the subdataset, agreement between the Swiss and ACGIH skin notations varied between 82 and 87%. Chemicals with a skin notation were more likely to have higher dermal risk indices and lower dermal LD(50) than chemicals without a notation (probabilities between 60 and 70%). The risk indices, based on cumulative dose and kinetic steady state, respectively, appeared proportional up to a constant independent of chemical-specific properties. They agreed well with dermal LD(50)s (Spearman correlation coefficients -0.42 to -0.43). Dermal-to-other routes LD(50) ratios were moderately associated with QSAR-based transdermal fluxes (Spearman correlation coefficients -0.2 to -0.3). CONCLUSIONS: The plausible but variable relationship between current skin notations and the different approaches tested confirm the need to improve current skin notations. QSAR-based risk indices and dermal toxicity data might be successfully integrated in a systematic alternative to current skin notations for detecting chemicals associated with potential dermal risk in the workplace. [Authors]
Resumo:
BACKGROUND: Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METHODS: The following nebulizers were tested: Sidestream Disposable jet nebulizer, Multisonic Infra Control ultrasonic nebulizer, and the Aerogen Pro and Aerogen Solo vibrating mesh nebulizers. Aerosol duration, temperature, and drug solution osmolality were measured during nebulization. Albuterol delivery was measured by a high-performance liquid chromatography system with fluorometric detection. The droplet size distribution was analyzed with a laser granulometer. RESULTS: The ultrasonic nebulizer was the fastest device based on the duration of nebulization; the jet nebulizer was the slowest. Solution temperature decreased during nebulization when the jet nebulizer and vibrating mesh nebulizers were used, but it increased with the ultrasonic nebulizer. Osmolality was stable during nebulization with the vibrating mesh nebulizers, but increased with the jet nebulizer and ultrasonic nebulizer, indicating solvent evaporation. Albuterol delivery was 1.6 and 2.3 times higher with the ultrasonic nebulizer and vibrating mesh nebulizers devices, respectively, than with the jet nebulizer. Particle size was significantly higher with the ultrasonic nebulizer. CONCLUSIONS: The in vitro model was effective for comparing nebulizer types, demonstrating important differences between nebulizer types. The new devices, both the ultrasonic nebulizers and vibrating mesh nebulizers, delivered more aerosolized drug than traditional jet nebulizers.
Resumo:
Stress radiographs have been recommended in order to obtain a better objective quantification of abnormal compartment knee motion. This tool has showed to be superior in quantifying a posterior cruciate ligament (PCL) lesion compared to clinical or arthrometer evaluation. Different radiographic techniques have been described in literature to quantify posterior pathological laxity. In this study we evaluated the total amount of posterior displacement (PTD) and side to side difference (SSD), before and after surgical reconstruction of PCL or PCL and posterolateral complex (PLC), using two different stress radiography techniques (Telos stress and kneeling view). Twenty patients were included in this study. We found a statistical significant difference about both total PTD and SSD among the two techniques preoperatively and at follow-up, with greatest values occurring using the kneeling view. Although stress radiographies has been introduced to allow an objective quantification of laxity in ligamentous injured knee, we believe that further studies on a large numbers of subjects are required to define the relationship between PTD values, measured with stress knee radiography, particularly using kneeling view, and ligamentous knee injury, in order to obtain a real useful tool in the decision making process, as well as to evaluate the outcome after ligamentous surgery.
Resumo:
This randomized study compares the coronary perfusion rate in patients with acute myocardial infarction (AMI) treated with 2 different intravenous thrombolytic agents: streptokinase 1.5 million U given over 60 minutes and anisoylated human plasminogen streptokinase activator complex (anistreplase) administrated as a bolus of 30 U over 5 minutes. One hundred seventy-five patients (149 men and 26 women, mean age 54 years) have been included in this study. Eighty-nine patients were treated with anistreplase and 86 patients with streptokinase. AMI was inferior in 54 patients (61%) in the anistreplase group and in 54 patients (63%) in the streptokinase group. It was anterior in 35 (40%) and 32 (37%) patients, respectively. Coronary angiography and ventriculography were performed at a mean time (+/- SEM) of 207 +/- 11 minutes after the beginning of thrombolysis in 170 patients. A perfusion score grade of 2 or 3 according to the Thrombolysis in Myocardial Infarction trial was found in 63 patients (72%) in the anistreplase group and in 56 patients (68%) in the streptokinase group (p = NS). Severe bleeding occurred in 7 patients (8%) after anistreplase and in 6 patients (7%) after streptokinase. No cerebral hemorrhage occurred. Nine patients (5%) died during their hospital stay: 6 after anistreplase and 3 after streptokinase. It is concluded that intravenous administration of anistreplase or streptokinase is efficient and safe. Coronary patency 207 minutes after fibrinolysis, incidence of adverse events and mortality are similar in both groups.
Resumo:
Copper-67 has comparable beta-particle emissions to that of 131I, but it displays more favorable gamma emission characteristics for application in radioimmunotherapy (RIT). This study investigates the potential of 67Cu-labeled monoclonal antibody (MAb) 35 for RIT of colorectal carcinoma. METHODS: Biokinetics of simultaneously injected 67Cu- and 125I-labeled MAb35 were studied in six patients scheduled for surgery of primary colorectal cancer. RESULTS: Whole-body clearance (T 1/2) of 67Cu, estimated from sequential anterior and posterior whole-body scans and corrected for decay of 67Cu, was 41 hr. Serum clearance of 67Cu was faster (27.41 hr) than that of 125I (38.33 hr). Mean tumor uptake of the 67Cu-labeled compound (0.0133% ID/g) exceeded that of 125I (0.0095% ID/g), and tumor-to-blood ratios were higher for 67Cu than for 125I, with averages of 6.07 and 2.41, respectively. The average 67Cu/125I ratio was 1.9 for tumor uptake, 0.7 for blood and 2.6 for tumor-to-blood ratios. Nonspecific liver uptake of 67Cu as calculated from whole-body scans was high in four patients, up to 25% of residual whole-body activity at 48 hr, but did not increase with time. We also observed some nonspecific bowel activity, as well as moderate to high uptake in benign polyps. CONCLUSION: Copper-67-labeled MAb35 is more favorable than its radioiodine-labeled counterpart for RIT of colorectal carcinoma due to higher tumor-to-blood ratios, but the problem of nonspecific liver and bowel uptake must first be overcome. The absolute accumulation of activity in tumor remains low, however, so the probability of cure with this compound alone is questionable. The use of 67Cu as one component of a multimodality adjuvant treatment seems to remain the most appropriate application for RIT.
Resumo:
Profiling miRNA levels in cells with miRNA microarrays is becoming a widely used technique. Although normalization methods for mRNA gene expression arrays are well established, miRNA array normalization has so far not been investigated in detail. In this study we investigate the impact of normalization on data generated with the Agilent miRNA array platform. We have developed a method to select nonchanging miRNAs (invariants) and use them to compute linear regression normalization coefficients or variance stabilizing normalization (VSN) parameters. We compared the invariants normalization to normalization by scaling, quantile, and VSN with default parameters as well as to no normalization using samples with strong differential expression of miRNAs (heart-brain comparison) and samples where only a few miRNAs are affected (by p53 overexpression in squamous carcinoma cells versus control). All normalization methods performed better than no normalization. Normalization procedures based on the set of invariants and quantile were the most robust over all experimental conditions tested. Our method of invariant selection and normalization is not limited to Agilent miRNA arrays and can be applied to other data sets including those from one color miRNA microarray platforms, focused gene expression arrays, and gene expression analysis using quantitative PCR.
Resumo:
PURPOSE: Hypoxia is known to reduce maximal oxygen uptake (VO(2max)) more in trained than in untrained subjects in several lowland sports. Ski mountaineering is practiced mainly at altitude, so elite ski mountaineers spend significantly longer training duration at altitude than their lower-level counterparts. Since acclimatization in hypobaric hypoxia is effective, the authors hypothesized that elite ski mountaineers would exhibit a VO2max decrement in hypoxia similar to that of recreational ski mountaineers. METHODS: Eleven elite (E, Swiss national team) and 12 recreational (R) ski mountaineers completed an incremental treadmill test to exhaustion in normobaric hypoxia (H, 3000 m, F(1)O(2) 14.6% ± 0.1%) and in normoxia (N, 485 m, F(1)O(2) 20.9% ± 0.0%). Pulse oxygen saturation in blood (SpO(2)), VO(2max), minute ventilation, and heart rate were recorded. RESULTS: At rest, hypoxic ventilatory response was higher (P < .05) in E than in R (1.4 ± 1.9 vs 0.3 ± 0.6 L · min⁻¹ · kg⁻¹). At maximal intensity, SpO(2) was significantly lower (P < .01) in E than in R, both in N (91.1% ± 3.3% vs 94.3% ± 2.3%) and in H (76.4% ± 5.4% vs 82.3% ± 3.5%). In both groups, SpO(2) was lower (P < .01) in H. Between N and H, VO(2max) decreased to a greater extent (P < .05) in E than in R (-18% and -12%, P < .01). In E only, the VO(2max) decrement was significantly correlated with the SpO(2) decrement (r = .74, P < .01) but also with VO(2max) measured in N (r = .64, P < .05). CONCLUSION: Despite a probable better acclimatization to altitude, VO(2max) was more reduced in E than in R ski mountaineers, confirming previous results observed in lowlander E athletes.
Resumo:
OBJECTIVE: In general population survey instruments that measure volume of drinking, additional questions and shorter reference periods yield higher volumes. Comparison studies have focused on volume but not on associations between volume and consequences. METHOD: From a cohort study on substance use risk factors (Cohort Study on Substance Use Risk Factors [C-SURF]), baseline data were analyzed for 5,074 young (approximately 20-year-old) men who were drinkers in the past 12 months. Volume of drinking was measured by a generic quantity-frequency (QF) instrument, an extended QF (separately for weekends and weekdays) instrument with 12-months recall, and a retrospective past-week diary. Associations of consequences with and without attribution of alcohol as a cause, Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), criteria for dependence, and DSM-5 alcohol use disorder in the past 12 months were analyzed. RESULTS: The generic QF measure resulted in lower volume compared with either the extended QF measure (more questions) or the retrospective diary (the most questions and the shortest recall period). For outcomes, however, the extended QF assessment performed the best and the diary the worst. CONCLUSIONS: Higher volume yields are not always better regarding associations with outcomes. The extended QF instrument better captures the variability of drinking. The retrospective diary performs poorly for associations because of the mismatch with the recall period for past-12-months consequences and the potential for misclassification of past-week abstainers and heavy drinkers because of an uncommon past week. Diaries are not recommended for research investigating individual associations between exposure and outcomes in young populations if consequences are measured with a sufficiently long interval to capture rare consequences. (J. Stud. Alcohol Drugs, 75, 880-888, 2014).