179 resultados para Robust epipolar-geometry estimation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. ABSTRACTS - RÉSUMÉSSCIENTIFIC ABSTRACT - ENGLISH VERSIONGeometry, petrology and growth of a shallow crustal laccolith: the Torres del Paine Mafi c Complex (Patagonia)The Torres del Paine intrusive complex (TPIC) is a composite mafic-granitic intrusion, ~70km2, belonging to a chain of isolated Miocene plutons in southern Patagonia. Their position is intermediate between the Mesozoic-Cenozoic calc-alkaline subduction related Patagonian batholith in the West and the late Cenozoic alkaline basaltic back-arc related plateau lavas in the East. The Torres del Paine complex formed during an important reconfiguration of the Patagonian geodynamic setting, with a migration of magmatism from the arc to the back-arc, possibly related to the Chile ridge subductionThe complex intruded the flysch of the Cretaceous Cerro Toro and Punta Barrosa Formations during the Miocene, creating a well-defined narrow contact aureole of 200-400 m width.In its eastern part, the Torres del Paine intrusive complex is a laccolith, composed of a succession of hornblende-gabbro to diorite sills at its base, with a total thickness of ~250m, showing brittle contacts with the overlying granitic sills, that form spectacular cliffs of more than 1000m. This laccolith is connected, in the western part, to its feeding system, with vertical alternating sheets of layered gabbronorite and Hbl-gabbro, surrounded and percolated by diorites. ID-TIMS U-Pb on zircons on feeder zone (FZ) gab- bros yield 12.593±0.009Ma and 12.587±0.009Ma, which is identifcal within error to the oldest granite dated so far by Michel et al. (2008). In contrast, the laccolith mafic complex is younger than than the youngest granite (12.50±0.02Ma), and has been emplaced from 12.472±0.009Ma to 12.431 ±0.006Ma, by under-accretion beneath the youngest granite at the interface with previously emplaced mafic sills.The gabbronorite crystallization sequence in the feeder zone is dominated by olivine, plagioclase, clinopyroxene and orthopyroxene, while amphibole forms late interstitial crystals. The crystallization sequence is identical in Hornblende-gabbro from the feeder zone, with higher modal hornblende. Gabbronorite and Hornblende-gabbro both display distinct Eu and Sr positive anomalies. In the laccolith, a lower Hornblende-gabbro crystallized in sills and evolved to a high alkali shoshonitic series. The Al203, Ti02, Na20, K20, Ba and Sr composition of these gabbros is highly variable and increases up to ~50wt% Si02. The lower hornblende-gabbro is characterized by kaersutite anhedral cores with inclusions of olivine, clino- and orthopyroxene and rare apatite and An70 plagioclase. Trace element modelling indicates that hornblende and clinopyroxene are in equilibrium with a liquid whose composition is similar to late basaltic trachyandesitic dikes that cut the complex. The matrix in the lower hornblende gabbro is composed of normally zoned oligoclase, Magnesio-hornblende, biotite, ilmenite and rare quartz and potassium feldspar. This assemblage crystallized in-situ from a Ba and Sr-depleted melts. In contrast, the upper Hbl-gabbro is high-K calc-alkaline. Poikilitic pargasite cores have inclusions of euhedral An70 plagioclase inclusions, and contain occasionally clinopyroxene, olivine and orthopyroxene. The matrix composition is identical to the lower hornblende-gabbro and similar to the diorite. Diorite bulk rock compositions show the same mineralogy but different modal proportions relative to hornblende-gabbrosThe Torres del Paine Intrusive Complex isotopic composition is 87Sr/86Sr=0.704, 143Nd/144Nd=0.5127, 206Pb/204Pb=18.70 and 207Pb/204Pb=15.65. Differentiated dioritic and granitic units may be linked to the gabbroic cumulates series, with 20-50% trapped interstitial melt, through fractionation of olivine-bearing gabbronorite or hornblende-gabbro fractionation The relative homogeneity of the isotopic compositions indicate that only small amounts of assimilation occurred. Two-pyroxenes thermometry, clinopyroxene barometry and amphibole-plagioclase thermometry was used to estimate pressure and temperature conditions. The early fractionation of ultramafic cumulates occurs at mid to lower crustal conditions, at temperatures exceeding 900°C. In contrast, the TPIC emplacement conditions have been estimated to ~0.7±0.5kbar and 790±60°C.Based on field and microtextural observations and geochemical modelling, fractionation of basaltic-trachyandesitic liquids at intermediate to lower crustal levels, has led to the formation of the Torres del Paine granites. Repetitive replenishment of basaltic trachy- andesitic liquid in crustal reservoirs led to mixed magmas that will ascend via the feeder zone, and crystallize into a laccolith, in the form of successive dioritic and gabbroic sills. Dynamic fractionation during emplacement concentrated hornblende rich cumulates in the center of individual sills. Variable degrees.of post-emplacement compaction led to the expulsion of felsic liquids that preferentially concentrated at the top of the sills. Incremental sills amalgamation of the entire Torres del Paine Intrusive Complex has lasted for ~160ka.RESUME SCIENTIFIQUE - VERSION FRANÇAISEGéométrie, pétrologie et croissance d'un laccolite peu profond : Le complexe ma- fique du Torres del Paine (Patagonie)Le Complexe Intrusif du Torres del Paine (CITP) est une intrusion bimodale, d'environ 70km2, appartenant à une chaîne de plutons Miocènes isolés, dans le sud de la Patago-nie. Leur position est intermédiaire entre le batholite patagonien calco-alcalin, à l'Ouest, mis en place au Mesozoïque-Cenozoïque dans un contexte de subduction, et les basal-tes andésitiques et trachybasaltes alcalins de plateau, plus jeune, à l'Est, lié à l'ouverture d'un arrière-arc.A son extrémité Est, le CITP est une succession de sills de gabbro à Hbl et de diorite, sur une épaisseur de ~250m, avec des évidences de mélange. Les contacts avec les sills de granite au-dessus, formant des parois de plus de 1000m, sont cassants. Ce laccolite est connecté, dans sa partie Ouest, à une zone d'alimentation, avec des intrusions sub-ver- ticales de gabbronorite litée et de gabbro à Hbl, en alternance. Celles-ci sont traversées et entourées par des diorites. Les zircons des gabbros de la zone d'alimentation, datés par ID-TIMS, ont cristallisés à 12.593±0.009Ma et 12.587±0.009Ma, ce qui correspond au plus vieux granite daté à ce jour par Michel et al. (2008). A l'inverse, les roches manques du laccolite se sont mises en place entre 12.472±0.009Ma et 12.431 ±0.006Ma, par sous-plaquage successifs à l'interface avec le granite le plus jeune daté à ce jour (12.50±0.02Ma).La séquence de cristallisation des gabbronorites est dominée par Ol, Plg, Cpx et Opx, alors que la Hbl est un cristal interstitiel. Elle est identique dans les gabbros à Hbl de la zone d'alimentation, avec ~30%vol de Hbl. Les gabbros de la zone d'alimentation montrent des anomalies positives en Eu et Sr distinctes. Dans le laccolite, le gabbro à Hbl inférieur évolue le long d'une série shoshonitique, riche en éléments incompatibles. Sa concentration en Al203, Ti02, Na20, K20, Ba et Sr est très variable et augmente rapide-ment jusqu'à ~50wt% Si02. Il est caractérisé par la présence de coeurs résorbés de kaer- sutite, entourés de Bt, et contenant des inclusions d'OI, Cpx et Opx, ou alors d'Ap et de rares Plg (An70). Hbl et Cpx ont cristallisés à partir d'un liquide de composition similaire aux dykes trachy-andesite basaltique du CITP. La matrice, cristallisée in-situ à partir d'un liquide pauvre en Ba et Sr, est composée d'oligoclase zoné de façon simple, de Mg-Hbl, Bt, llm ainsi que de rares Qtz et KF. Le gabbro à Hbl supérieur, quant à lui, appartient à une suite chimique calco-alcaline riche en K. Des coeurs poecilitiques de pargasite con-tiennent de nombreuses inclusions de Plg (An70) automorphe, ainsi que des Ol, Cpx et Opx. La composition de la matrice est identique à celle des gabbros à Hbl inférieurs et toutes deux sont similaires à la minéralogie des diorites. Les analyses sur roches totales de diorites montrent la même variabilité que celles de gabbros à Hbl, mais avec une ten-eur en Si02 plus élevée.La composition isotopique des liquides primitifs du CITP a été mesurée à 87Sr/86Sr=0.704, 143Nd/144Nd=0.5127, 206Pb/204Pb=18.70 et 207Pb/204Pb=15.65. Les granites et diorites différenciés peuvent être reliés à des cumulais gabbronoritiques (F=0.74 pour les granites et F=1-0.5 pour les diorites) et gabbroïques à Hbl (fractionnement supplémentaire pour les granites, avec F=0.3). La cristallisation de 20 à 50%vol de liquide interstitiel piégé dans les gabbros du CITP explique leur signature géochimique. Seules de faibles quantités de croûte continentale ont été assimilées. La température et la pression de fractionnement ont été estimées, sur la base des thermobaromètres Opx-Cpx, Hbl-Plg et Cpx, à plus de 900°C et une profondeur correspondant à la croûte inférieure-moyenne. A l'inverse, les conditions de cristallisation de la matrice des gabbros et diorites du laccolite ont été estimées à 790±60°C et ~0.7±0.5kbar.Je propose que les liquides felsiques du CITP se soient formés par cristallisation frac-tionnée en profondeur des assemblages minéralogiques observés dans les gabbros du CITP, à partir d'un liquide trachy-andesite basaltique. La percolation de magma dans les cristaux accumulés permet la remontée du mélange à travers la zone d'alimentation, vers le laccolite, où des sills se mettent en place successivement. L'amalgamation de sills dans le CITP a duré ~160ka.Le CITP s'est formé durant une reconfiguration importante du contexte géodynamique en Patagonie, avec un changement du magmatisme d'arc vers un volcanisme d'arrière- arc. Ce changement est certainement lié à la subduction de la ride du Chili.RESUME GRAND PUBLIC - VERSION FRANÇAISEGéométrie, pétrologie et croissance d'une chambre magmatique peu profonde : Le complexe mafique du Torres del Paine (Patagonie)Le pourtour de l'Océan Pacifique est caractérisé par une zone de convergence de plaques tectoniques, appelée zone de subduction, avec le plongement de croûte océa-nique sous les Andes dans le cas de la Patagonie. De nombreux volcans y sont associés, formant la ceinture de feu. Mais seuls quelques pourcents de tout le magma traversant la croûte terrestre parviennent à la surface et la majeure partie cristallise en profondeur, dans des chambres magmatiques. Quelles est leur forme, croissance, cristallisation et durée de vie ? Le complexe magmatique du Torres del Paine représente l'un des meilleurs endroits au monde pour répondre à ces questions. Il se situe au sud de la Patagonie, formant un massif de 70km2. Des réponses peuvent être trouvées à différentes échelles, variant de la montagne à des minéraux de quelques 1000ème de millimètres.Il est possible de distinguer trois types de roches : des gabbros et des diorites sur une épaisseur de 250m, surmontées par des parois de granite de plus de 1000m. Les contacts entre ces roches sont tous horizontaux. Entre granites et gabbro-diorite, le contact est net, indiquant que le second magma s'est mis en place au contact avec un magma plus ancien, totalement solidifié. Entre gabbros et diorites, les contacts sont diffus, souvent non-linéaires, indiquant à l'inverse la mise en contact de magmas encore partiellement liquides. Dans la partie Ouest de cette chambre magmatique, les contacts entre roches sont verticaux. Il s'agit certainement du lieu de remplissage de la chambre magmatique.Lors du refroidissement d'un magma, différents cristaux vont se former. Leur stabilité et leur composition varient en fonction de la pression, de la température ou de la chimie du magma. La séquence de cristallisation peut être définie sur la base d'observations microscopiques et de la composition chimique des minéraux. Différents gabbros sont ainsi distingués : le gabbro à la base est riche en hornblende, d'une taille de ~5mm, sans inclusion de plagioclase mais avec des cristaux d'olivine, clinopyroxene et orthopyroxene inclus ; le gabbro supérieur est lui-aussi riche en hornblende (~5mm), avec les mêmes inclusions additionnées de plagioclase. Ces cristaux se sont formés à une température supérieure à 900°C et une profondeur correspondant à la croûte moyenne ou inférieure. Les minéraux plus fin, se trouvant hors des cristaux de hornblende des deux gabbros, sont similaires à ceux des diorites : plagioclase, biotite, hornblende, apatite, quartz et feldspath alcalin. Ces minéraux sont caractéristiques des granites. Ils ont cristallisé à ~790°C et ~2km de profondeur.La cristallisation des minéraux et leur extraction du magma par gravité provoque un changement progressif de la composition de ce dernier. Ainsi, après extraction d'olivine et d'orthopyroxene riches en Mg, de clinopyroxene riche en Ca, de plagioclase riche en Ca et Al et d'hornblende riche en Ca, Al et Mg, le liquide final sera appauvri en ces élé-ments. Un lien peut ainsi être proposé entre les diorites dont la composition est proche du liquide de départ, les granites dont la composition est similaire au liquide final, et les gabbros dont la minéralogie correspond aux minéraux extraits.L'utilisation de zircons, un minéral riche en U dont les atomes se transforment en Pb par décomposition radioactive au cours de millions d'années, permet de dater le refroidissement des roches qui les contiennent. Ainsi, il a été observé que les roches de la zone d'alimentation, à l'Ouest du complexe magmatique, ont cristallisés il y a 12.59±0.01 Ma, en même temps que les granites les plus vieux, se trouvant au sommet de la chambre magmatique, datés par Michel et al. (2008). Les deux roches pourraient donc avoir la même origine. A l'inverse, les gabbros et diorites de la chambre magmatique ont cristallisé entre 12.47±0.01Ma et 12.43±0.01Ma, les roches les plus vieilles étant à la base.En comparant la composition des roches du Torres del Paine avec celles d'autres en-tités géologiques de Patagonie, les causes du magmatisme peuvent être recherchées. A l'Ouest, on trouve en effet des intrusions granitiques, plus anciennes, caractéristiques de zones de convergence de plaque tectonique, alors qu'à l'Est, des laves basaltiques plus jeunes sont caractéristiques d'une dynamique d'extension. Sur la base des compositions chimiques des roches de ces différentes entités, l'évolution progressive de l'une à l'autre a pu être démontrée. Elle est certainement due à l'arrivée d'une dorsale océanique (zone d'extension crustale et de création de croûte océanique par la remontée de magma) dans la zone de subduction, le long des Andes.Je propose que, dans un premier temps, des magmas granitiques sont remontés dans la chambre magmatique, laissant d'importants volumes de cristaux dans la croûte pro-fonde. Dans un second épisode, les cristaux formés en profondeur ont été transportés à travers la croûte continentale, suite au mélange avec un nouveau magma injecté. Ces magmas chargés de cristaux ont traversé la zone d'alimentation avant de s'injecter dans la chambre magmatique. Différents puises ont été distingués, injectés dans la chambre magmatique du sommet à la base concernant les granites, puis à la base du granite le plus jeune pour les gabbros et diorites. Le complexe magmatique du Torres del Paine s'est construit sur une période totale de 160'000±20'000 ans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time periods composing stance phase of gait can be clinically meaningful parameters to reveal differences between normal and pathological gait. This study aimed, first, to describe a novel method for detecting stance and inner-stance temporal events based on foot-worn inertial sensors; second, to extract and validate relevant metrics from those events; and third, to investigate their suitability as clinical outcome for gait evaluations. 42 subjects including healthy subjects and patients before and after surgical treatments for ankle osteoarthritis performed 50-m walking trials while wearing foot-worn inertial sensors and pressure insoles as a reference system. Several hypotheses were evaluated to detect heel-strike, toe-strike, heel-off, and toe-off based on kinematic features. Detected events were compared with the reference system on 3193 gait cycles and showed good accuracy and precision. Absolute and relative stance periods, namely loading response, foot-flat, and push-off were then estimated, validated, and compared statistically between populations. Besides significant differences observed in stance duration, the analysis revealed differing tendencies with notably a shorter foot-flat in healthy subjects. The result indicated which features in inertial sensors' signals should be preferred for detecting precisely and accurately temporal events against a reference standard. The system is suitable for clinical evaluations and provides temporal analysis of gait beyond the common swing/stance decomposition, through a quantitative estimation of inner-stance phases such as foot-flat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The n-octanol/water partition coefficient (log Po/w) is a key physicochemical parameter for drug discovery, design, and development. Here, we present a physics-based approach that shows a strong linear correlation between the computed solvation free energy in implicit solvents and the experimental log Po/w on a cleansed data set of more than 17,500 molecules. After internal validation by five-fold cross-validation and data randomization, the predictive power of the most interesting multiple linear model, based on two GB/SA parameters solely, was tested on two different external sets of molecules. On the Martel druglike test set, the predictive power of the best model (N = 706, r = 0.64, MAE = 1.18, and RMSE = 1.40) is similar to six well-established empirical methods. On the 17-drug test set, our model outperformed all compared empirical methodologies (N = 17, r = 0.94, MAE = 0.38, and RMSE = 0.52). The physical basis of our original GB/SA approach together with its predictive capacity, computational efficiency (1 to 2 s per molecule), and tridimensional molecular graphics capability lay the foundations for a promising predictor, the implicit log P method (iLOGP), to complement the portfolio of drug design tools developed and provided by the SIB Swiss Institute of Bioinformatics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The prognostic impact of complete response (CR) achievement in multiple myeloma (MM) has been shown mostly in the context of autologous stem-cell transplantation. Other levels of response have been defined because, even with high-dose therapy, CR is a relatively rare event. The purpose of this study was to analyze the prognostic impact of very good partial response (VGPR) in patients treated with high-dose therapy. PATIENTS AND METHODS: All patients were included in the Intergroupe Francophone du Myelome 99-02 and 99-04 trials and treated with vincristine, doxorubicin, and dexamethasone (VAD) induction therapy followed by double autologous stem-cell transplantation (ASCT). Best post-ASCT response assessment was available for 802 patients. RESULTS: With a median follow-up of 67 months, median event-free survival (EFS) and 5-year EFS were 42 months and 34%, respectively, for 405 patients who achieved at least VGPR after ASCT versus 32 months and 26% in 288 patients who achieved only partial remission (P = .005). Five-year overall survival (OS) was significantly superior in patients achieving at least VGPR (74% v 61% P = .0017). In multivariate analysis, achievement of less than VGPR was an independent factor predicting shorter EFS and OS. Response to VAD had no impact on EFS and OS. The impact of VGPR achievement on EFS and OS was significant in patients with International Staging System stages 2 to 3 and for patients with poor-risk cytogenetics t(4;14) or del(17p). CONCLUSION: In the context of ASCT, achievement of at least VGPR is a simple prognostic factor that has importance in intermediate and high-risk MM and can be informative in more patients than CR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the adverse impact of image noise on the perception of important clinical details in digital mammography, routine quality control measurements should include an evaluation of noise. The European Guidelines, for example, employ a second-order polynomial fit of pixel variance as a function of detector air kerma (DAK) to decompose noise into quantum, electronic and fixed pattern (FP) components and assess the DAK range where quantum noise dominates. This work examines the robustness of the polynomial method against an explicit noise decomposition method. The two methods were applied to variance and noise power spectrum (NPS) data from six digital mammography units. Twenty homogeneously exposed images were acquired with PMMA blocks for target DAKs ranging from 6.25 to 1600 µGy. Both methods were explored for the effects of data weighting and squared fit coefficients during the curve fitting, the influence of the additional filter material (2 mm Al versus 40 mm PMMA) and noise de-trending. Finally, spatial stationarity of noise was assessed.Data weighting improved noise model fitting over large DAK ranges, especially at low detector exposures. The polynomial and explicit decompositions generally agreed for quantum and electronic noise but FP noise fraction was consistently underestimated by the polynomial method. Noise decomposition as a function of position in the image showed limited noise stationarity, especially for FP noise; thus the position of the region of interest (ROI) used for noise decomposition may influence fractional noise composition. The ROI area and position used in the Guidelines offer an acceptable estimation of noise components. While there are limitations to the polynomial model, when used with care and with appropriate data weighting, the method offers a simple and robust means of examining the detector noise components as a function of detector exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years there has been an explosive growth in the development of adaptive and data driven methods. One of the efficient and data-driven approaches is based on statistical learning theory (Vapnik 1998). The theory is based on Structural Risk Minimisation (SRM) principle and has a solid statistical background. When applying SRM we are trying not only to reduce training error ? to fit the available data with a model, but also to reduce the complexity of the model and to reduce generalisation error. Many nonlinear learning procedures recently developed in neural networks and statistics can be understood and interpreted in terms of the structural risk minimisation inductive principle. A recent methodology based on SRM is called Support Vector Machines (SVM). At present SLT is still under intensive development and SVM find new areas of application (www.kernel-machines.org). SVM develop robust and non linear data models with excellent generalisation abilities that is very important both for monitoring and forecasting. SVM are extremely good when input space is high dimensional and training data set i not big enough to develop corresponding nonlinear model. Moreover, SVM use only support vectors to derive decision boundaries. It opens a way to sampling optimization, estimation of noise in data, quantification of data redundancy etc. Presentation of SVM for spatially distributed data is given in (Kanevski and Maignan 2004).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The geochemical compositions of biogenic carbonates are increasingly used for palaeoenvironmental reconstructions. The skeletal delta O-18 temperature relationship is dependent on water salinity, so many recent studies have focused on the Mg/Ca and Sr/Ca ratios because those ratios in water do not change significantly on short time scales. Thus, those elemental ratios are considered to be good palaeotemperature proxies in many biominerals, although their use remains ambiguous in bivalve shells. Here, we present the high-resolution Mg/Ca ratios of two modern species of juvenile and adult oyster shells, Crassostrea gigas and Ostrea edulis. These specimens were grown in controlled conditions for over one year in two different locations. In situ monthly Mn-marking of the shells has been used for day calibration. The daily Mg/Ca.ratios in the shell have been measured with an electron microprobe. The high frequency Mg/Ca variation of all specimens displays good synchronism with lunar cycles, suggesting that tides strongly influence the incorporation of Mg/Ca into the shells. Highly significant correlation coefficients (0.70<R<0.83, p<0.0001) between the Mg/Ca ratios and the seawater temperature are obtained only for juvenile C. gigas samples, while metabolic control of Mg/Ca incorporation and lower shell growth rates preclude the use of the Mg/Ca ratio in adult shells as a palaeothermometer. Data from three juvenile C. gigas shells from the two study sites are selected to establish a relationship: T = 3.77Mg/Ca + 1.88, where T is in degrees C and Mg/Ca in mmol/mol. (c) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the accuracy of skinfold thicknesses, BMI and waist circumference for the prediction of percentage body fat (PBF) in a representative sample of 372 Swiss children aged 6-13 years. PBF was measured using dual-energy X-ray absorptiometry. On the basis of a preliminary bootstrap selection of predictors, seven regression models were evaluated. All models included sex, age and pubertal stage plus one of the following predictors: (1) log-transformed triceps skinfold (logTSF); (2) logTSF and waist circumference; (3) log-transformed sum of triceps and subscapular skinfolds (logSF2); (4) log-transformed sum of triceps, biceps, subscapular and supra-iliac skinfolds (logSF4); (5) BMI; (6) waist circumference; (7) BMI and waist circumference. The adjusted determination coefficient (R² adj) and the root mean squared error (RMSE; kg) were calculated for each model. LogSF4 (R² adj 0.85; RMSE 2.35) and logSF2 (R² adj 0.82; RMSE 2.54) were similarly accurate at predicting PBF and superior to logTSF (R² adj 0.75; RMSE 3.02), logTSF combined with waist circumference (R² adj 0.78; RMSE 2.85), BMI (R² adj 0.62; RMSE 3.73), waist circumference (R² adj 0.58; RMSE 3.89), and BMI combined with waist circumference (R² adj 0.63; RMSE 3.66) (P < 0.001 for all values of R² adj). The finding that logSF4 was only modestly superior to logSF2 and that logTSF was better than BMI and waist circumference at predicting PBF has important implications for paediatric epidemiological studies aimed at disentangling the effect of body fat on health outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Protein-energy malnutrition is highly prevalent in aged populations. Associated clinical, economic, and social burden is important. A valid screening method that would be robust and precise, but also easy, simple, and rapid to apply, is essential for adequate therapeutic management. OBJECTIVES: To compare the interobserver variability of 2 methods measuring food intake: semiquantitative visual estimations made by nurses versus calorie measurements performed by dieticians on the basis of standardized color digital photographs of servings before and after consumption. DESIGN: Observational monocentric pilot study. SETTING/PARTICIPANTS: A geriatric ward. The meals were randomly chosen from the meal tray. The choice was anonymous with respect to the patients who consumed them. MEASUREMENTS: The test method consisted of the estimation of calorie consumption by dieticians on the basis of standardized color digital photographs of servings before and after consumption. The reference method was based on direct visual estimations of the meals by nurses. Food intake was expressed in the form of a percentage of the serving consumed and calorie intake was then calculated by a dietician based on these percentages. The methods were applied with no previous training of the observers. Analysis of variance was performed to compare their interobserver variability. RESULTS: Of 15 meals consumed and initially examined, 6 were assessed with each method. Servings not consumed at all (0% consumption) or entirely consumed by the patient (100% consumption) were not included in the analysis so as to avoid systematic error. The digital photography method showed higher interobserver variability in calorie intake estimations. The difference between the compared methods was statistically significant (P < .03). CONCLUSIONS: Calorie intake measures for geriatric patients are more concordant when estimated in a semiquantitative way. Digital photography for food intake estimation without previous specific training of dieticians should not be considered as a reference method in geriatric settings, as it shows no advantages in terms of interobserver variability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tripping is considered a major cause of fall in older people. Therefore, foot clearance (i.e., height of the foot above ground during swing phase) could be a key factor to better understand the complex relationship between gait and falls. This paper presents a new method to estimate clearance using a foot-worn and wireless inertial sensor system. The method relies on the computation of foot orientation and trajectory from sensors signal data fusion, combined with the temporal detection of toe-off and heel-strike events. Based on a kinematic model that automatically estimates sensor position relative to the foot, heel and toe trajectories are estimated. 2-D and 3-D models are presented with different solving approaches, and validated against an optical motion capture system on 12 healthy adults performing short walking trials at self-selected, slow, and fast speed. Parameters corresponding to local minimum and maximum of heel and toe clearance were extracted and showed accuracy ± precision of 4.1 ± 2.3 cm for maximal heel clearance and 1.3 ± 0.9 cm for minimal toe clearance compared to the reference. The system is lightweight, wireless, easy to wear and to use, and provide a new and useful tool for routine clinical assessment of gait outside a dedicated laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring the performance is a crucial task for elite sports during both training and competition. Velocity is the key parameter of performance in swimming, but swimming performance evaluation remains immature due to the complexities of measurements in water. The purpose of this study is to use a single inertial measurement unit (IMU) to estimate front crawl velocity. Thirty swimmers, equipped with an IMU on the sacrum, each performed four different velocity trials of 25 m in ascending order. A tethered speedometer was used as the velocity measurement reference. Deployment of biomechanical constraints of front crawl locomotion and change detection framework on acceleration signal paved the way for a drift-free integration of forward acceleration using IMU to estimate the swimmers velocity. A difference of 0.6 ± 5.4 cm · s(-1) on mean cycle velocity and an RMS difference of 11.3 cm · s(-1) in instantaneous velocity estimation were observed between IMU and the reference. The most important contribution of the study is a new practical tool for objective evaluation of swimming performance. A single body-worn IMU provides timely feedback for coaches and sport scientists without any complicated setup or restraining the swimmer's natural technique.