159 resultados para Psychological Assessment,Projective Methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Delirium is an independent predictor of increased length of stay, mortality, and treatment costs in critical care patients. Its incidence may be underestimated or overestimated if delirium is assessed by using subjective clinical impression alone rather than an objective instrument. Objectives To determine frequency of discrepancies between subjective and objective delirium monitoring. Methods An observational cohort study was performed in a surgical-cardiosurgical 31-bed intensive care unit of a university hospital. Patients' delirium status was rated daily by bedside nurses on the basis of subjective individual clinical impressions and by medical students on the basis of scores on the objective Confusion Assessment Method for the Intensive Care Unit. Results Of 160 patients suitable for analysis, 38.8% (n = 62) had delirium according to objective criteria at some time during their stay in the intensive care unit. A total of 436 paired observations were analyzed. Delirium was diagnosed in 26.1% of observations (n = 114) with the objective method. This percentage included 6.4% (n = 28) in whom delirium was not recognized via subjective criteria. According to subjective criteria, delirium was present in 29.4% of paired observations (n = 128), including 9.6% (n = 42) with no objective indications of delirium. A total of 8 patients with no evidence of delirium according to the objective criteria were prescribed haloperidol and lorazepam because the subjective method indicated they had delirium. Conclusions Use of objective criteria helped detect delirium in more patients and also identified patients mistakenly thought to have delirium who actually did not meet objective criteria for diagnosis of the condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Validated in vitro methods for skin corrosion and irritation were adopted by the OECD and by the European Union during the last decade. In the EU, Switzerland and countries adopting the EU legislation, these assays may allow the full replacement of animal testing for identifying and classifying compounds as skin corrosives, skin irritants, and non irritants. In order to develop harmonised recommendations on the use of in vitro data for regulatory assessment purposes within the European framework, a workshop was organized by the Swiss Federal Office of Public Health together with ECVAM and the BfR. It comprised stakeholders from various European countries involved in the process from in vitro testing to the regulatory assessment of in vitro data. Discussions addressed the following questions: (1) the information requirements considered useful for regulatory assessment; (2) the applicability of in vitro skin corrosion data to assign the corrosive subcategories as implemented by the EU Classification, Labelling and Packaging Regulation; (3) the applicability of testing strategies for determining skin corrosion and irritation hazards; and (4) the applicability of the adopted in vitro assays to test mixtures, preparations and dilutions. Overall, a number of agreements and recommendations were achieved in order to clarify and facilitate the assessment and use of in vitro data from regulatory accepted methods, and ultimately help regulators and scientists facing with the new in vitro approaches to evaluate skin irritation and corrosion hazards and risks without animal data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Malnutrition, a risk factor for osteoporotic fractures, is frequent in elderly people and, is underdiagnosed and undertreated. There are only few studies on the nutritional status of elderly people in Europe. The Mini Nutritional Assessment (MNA) is a non invasive and validated questionnaire to evaluate nutritional status in elderly people, classified in three groups: 1 degree score < 17: malnourished, 2 degrees score >17 and < 24: at risk of malnutrition, 3 degrees score >24: well-nourished, with a maximum of 30 points. Quantitative ultrasound of bone (QUS) is a method for assessing quality of bone which can be easily performed in nursing homes. Therefore, these two tests allowed to study the relationships between nutritional status and ultrasonic parameters of bone in 78 institutionalized women aged 86 +/- 6 years, living in 11 nursing homes around Lausanne (Switzerland). All were assessed by the MNA, had a measurement of the tricipital skin fold and of the grip strength. Functional status was evaluated by the scale "Activity of Daily Living" (ADL), and serum albumin level was measured when permitted. All had QUS of the calcaneus (with an Achilles, GE Lunar). The measured parameters are the Broadband Ultrasound Attenuation (BUA), attenuation of a band of ultrasonic frequencies through the medium, expressed in dB/MHz, and the Speed of Sound (SOS), speed of the ultrasounds through the medium, expressed in m/s. A third parameter, the stiffness index (SI), expressed as a percentage of the values obtained by the manufacturer in a young population and derived from BUA and SOS, was calculated automatically : SI = (0.67xBUA) + (0.28xSOS) - 420, expressed in percent compared to a young adult population (%YA). Fifteen percent of the women were undernourished and 58% were at risk of malnutrition. As expected, compared with the well-nourished minority, undernourished subjects had significant lower body mass index (BMI), tricipital skin fold (TSF), ADL score and albumin level (p < 0,01). The subjects "at risk of malnutrition" had significant lower BMI, ADL score (p < 0.01), tricipital skin fold and serum albumin (p < 0.05). Ultrasound parameters were low independently of the nutritional status. MNA score correlated significantly with tricipital skin fold (r = 0.508, p < 0.01), ADL (r = 0.538, p < 0.01) and albumin serum level (r = 0.409, p = 0.01). There was a trend for a correlation between the MNA and the ultrasound parameter BUA (r = 0.207, p = 0.07), whereas no correlation was found with SOS and SI. A multivariate analysis showed that tricipital skin fold and ADL explained 61% of the variance of the MNA. In conclusion, using simple and non invasive methods, this study showed that malnutrition and osteoporosis are frequent in institutionalized elderly persons in our country, and the ultrasound parameters are influenced by many others factors in addition to nutrition, especially at this age and in elderly residents of nursing homes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Oncological treatments are traditionally administered via intravenous injection by qualified personnel. Oral formulas which are developing rapidly are preferred by patients and facilitate administration however they may increase non-adherence. In this study 4 common oral chemotherapeutics are given to 50 patients, who are still in the process of inclusion, divided into 4 groups. The aim is to evaluate adherence and offer these patients interdisciplinary support with the joint help of doctors and pharmacists. We present here the results for capecitabine. Materials and Methods: The final goal is to evaluate adhesion in 50 patients split into 4 groups according to oral treatments (letrozole/exemestane, imatinib/sunitinib, capecitabine and temozolomide) using persistence and quality of execution as parameters. These parameters are evaluated using a medication event monitoring system (MEMS®) in addition to routine oncological visits and semi-structured interviews. Patients were monitored for the entire duration of treatment up to a maximum of 1 year. Patient satisfaction was assessed at the end of the monitoring period using a standardized questionary. Results: Capecitabine group included 2 women and 8 men with a median age of 55 years (range: 36−77 years) monitored for an average duration of 100 days (range: 5-210 days). Persistence was 98% and quality of execution 95%. 5 patients underwent cyclic treatment (2 out of 3 weeks) and 5 patients continuous treatment. Toxicities higher than grade 1 were grade 2−3 hand-foot syndrome in 1 patient and grade 3 acute coronary syndrome in 1 patient both without impact on adherence. Patients were satisfied with the interviews undergone during the study (57% useful, 28% very useful, 15% useless) and successfully integrated the MEMS® in their daily lives (57% very easily, 43% easily) according to the results obtained by questionary at the end of the monitoring period. Conclusion: Persistence and quality of execution observed in our Capecitabine group of patients were excellent and better than expected compared to previously published studies. The interdisciplinary approach allowed us to better identify and help patients with toxicities to maintain adherence. Overall patients were satisfied with the global interdisciplinary follow-up. With longer follow up better evaluation of our method and its impact will be possible. Interpretation of the results of patients in the other groups of this ongoing trial will provide us information for a more detailed analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Knowledge of the number of recent HIV infections is important for epidemiologic surveillance. Over the past decade approaches have been developed to estimate this number by testing HIV-seropositive specimens with assays that discriminate the lower concentration and avidity of HIV antibodies in early infection. We have investigated whether this "recency" information can also be gained from an HIV confirmatory assay. METHODS AND FINDINGS: The ability of a line immunoassay (INNO-LIA HIV I/II Score, Innogenetics) to distinguish recent from older HIV-1 infection was evaluated in comparison with the Calypte HIV-1 BED Incidence enzyme immunoassay (BED-EIA). Both tests were conducted prospectively in all HIV infections newly diagnosed in Switzerland from July 2005 to June 2006. Clinical and laboratory information indicative of recent or older infection was obtained from physicians at the time of HIV diagnosis and used as the reference standard. BED-EIA and various recency algorithms utilizing the antibody reaction to INNO-LIA's five HIV-1 antigen bands were evaluated by logistic regression analysis. A total of 765 HIV-1 infections, 748 (97.8%) with complete test results, were newly diagnosed during the study. A negative or indeterminate HIV antibody assay at diagnosis, symptoms of primary HIV infection, or a negative HIV test during the past 12 mo classified 195 infections (26.1%) as recent (< or = 12 mo). Symptoms of CDC stages B or C classified 161 infections as older (21.5%), and 392 patients with no symptoms remained unclassified. BED-EIA ruled 65% of the 195 recent infections as recent and 80% of the 161 older infections as older. Two INNO-LIA algorithms showed 50% and 40% sensitivity combined with 95% and 99% specificity, respectively. Estimation of recent infection in the entire study population, based on actual results of the three tests and adjusted for a test's sensitivity and specificity, yielded 37% for BED-EIA compared to 35% and 33% for the two INNO-LIA algorithms. Window-based estimation with BED-EIA yielded 41% (95% confidence interval 36%-46%). CONCLUSIONS: Recency information can be extracted from INNO-LIA-based confirmatory testing at no additional costs. This method should improve epidemiologic surveillance in countries that routinely use INNO-LIA for HIV confirmation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: We studied human cytomegalovirus (CMV) donor-to-recipient transmission patterns in organ transplantation by analyzing genomic variants on the basis of CMV glycoprotein B (gB) genotyping. METHODS: Organ transplant recipients were included in the study if they had CMV viremia, if they had received an organ from a CMV-seropositive donor, and if there was at least 1 other recipient of an organ from the same donor who developed CMV viremia. Genotypes (gB1-4) were determined by real-time polymerase chain reaction. RESULTS: Forty-seven recipients of organs from 21 donors developed CMV viremia. Twenty-three recipients had a pretransplant donor/recipient (D/R) CMV serostatus of D(+)/R(+), and 24 had a serostatus of D(+)/R(-). The prevalences of genotypes in recipients were as follows: for gB1, 51% (n = 24); for gB2, 19% (n = 9); for gB3, 9% (n = 4); for gB4, 0% (n = 0); and for mixed infection, 21% (n = 10). Recipients of an organ from a common donor had infection with CMV of the same gB genotype in 12 (57%) of 21 instances. Concordance between genotypes was higher among seronegative (i.e., D(+)/R(-)) recipients than among seropositive (D(+)/R(+)) recipients, although discordances resulting from the transmission of multiple strains were seen. In seropositive recipients, transmission of multiple strains from the donor could not be differentiated from reactivation of a recipient's own strains. CONCLUSION: Our analysis of strain concordance among recipients of organs from common donors showed that transmission of CMV has complex dynamic patterns. In seropositive recipients, transmission or reactivation of multiple CMV strains is possible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVE:. The information assessment method (IAM) permits health professionals to systematically document the relevance, cognitive impact, use and health outcomes of information objects delivered by or retrieved from electronic knowledge resources. The companion review paper (Part 1) critically examined the literature, and proposed a 'Push-Pull-Acquisition-Cognition-Application' evaluation framework, which is operationalized by IAM. The purpose of the present paper (Part 2) is to examine the content validity of the IAM cognitive checklist when linked to email alerts. METHODS: A qualitative component of a mixed methods study was conducted with 46 doctors reading and rating research-based synopses sent on email. The unit of analysis was a doctor's explanation of a rating of one item regarding one synopsis. Interviews with participants provided 253 units that were analysed to assess concordance with item definitions. RESULTS AND CONCLUSION: The content relevance of seven items was supported. For three items, revisions were needed. Interviews suggested one new item. This study has yielded a 2008 version of IAM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: There is little information regarding the determinants and trends of the prevalence of low cardiovascular risk factor (RF) profile in the general population. The aim of this study was to assess the prevalence and trends of low RF profile in the Swiss population according to different definitions. METHODS: Population-based cross-sectional studies conducted in 1984-1986 (N=3300), 1988-1989 (N=3331), 1992-1993 (N=3133) and 2003-2006 (N=6170) and restricted to age group 35-75 years. Seven different definitions of low RF profile were used to assess determinants, while two definitions were used to assess trends. RESULTS: Prevalence of low RF profile varied between 6.5% (95% confidence interval: 5.9-7.1) and 9.7% (9.0-10.5) depending on the definition used. This prevalence was higher than in other countries. Irrespective of the definition used, the prevalence of low RF profile was higher in women and in physically active participants, and decreased with increasing age or in the presence of a family history of cardiovascular disease. Using one definition, the prevalence of low RF profile increased from 3.8% (3.1-4.5) in 1984-1986 to 6.7% (6.1-7.3) in 2003-2006; using another definition, the results were 5.9% (5.1-6.8) and 9.7% (9.0-10.5), respectively. CONCLUSION: Switzerland is characterized by a high and increasing prevalence of low RF profile within the age group 35 to 75, irrespective of the criteria used. This high prevalence might partly explain the low and decreasing trend in cardiovascular mortality rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Diffusion-weighted magnetic resonance imaging (MRI) is increasingly being used for assessing the treatment succes in oncology, but the real clinical value needs to evaluated by comparison with other, already established, metabolic imaging techniques. PURPOSE: To prospectively evaluate the clinical potential of diffusion-weighted MRI with apparent diffusion coefficient (ADC) mapping for gastrointestinal stromal tumor (GIST) response to targeted therapy compared with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). MATERIAL AND METHODS: Eight patients (mean age, 56 ± 11 years) known to have metastatic GIST underwent 18F-FDG PET/CT and MRI (T1Gd, DWI [b = 50,300,600], ADC mapping) simultaneously, before and after change in targeted therapy. MR and PET/CT examinations were first analyzed blindly. Second, PET/CT images were co-registered with T1Gd-MR images for lesion detection. Only 18F-FDG avid lesions were considered. Maximum standardized uptake value (SUVmax) and the corresponding minimum ADCmin were measured for the six largest lesions per patient, if any, on baseline and follow-up examinations. The relationship between changes in SUVmax and ADCmin was analyzed (Spearman's correlation). RESULTS: Twenty-four metastases (12 hepatic, 12 extra-hepatic) were compared on PET/CT and MR images. SUVmax decreased from 7.7 ± 8.1 g/mL to 5.5 ± 5.4 g/mL (P = 0.20), while ADCmin increased from 1.2 ± 0.3 × 10(-3)mm(2)/s to 1.5 ± 0.3 × 10(-3)mm(2)/s (P = 0.0002). There was a significant association between changes in SUVmax and ADCmin (rho = - 0.62, P = 0.0014), but not between changes in lesions size (P = 0.40). CONCLUSION: Changes in ADCmin correlated with the response of 18F-FDG avid GIST to targeted therapy. Thus, diffusion-weighted MRI may represent a radiation-free alternative for follow-up treatment for metastatic GIST patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. PARTICIPANTS AND METHODS: Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. RESULTS: The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). CONCLUSIONS: Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to study the pharmacokinetics of irinotecan injected intravenously, intra-arterially, or loaded onto a delivery platform. MATERIAL AND METHODS: Fifty-four New Zealand White rabbits with VX2 liver tumor, divided in 3 groups of 17 rabbits, each received irinotecan either by intravenous (IV) route, intra-arterial hepatic (IA) route, or loaded on drug-eluting beads (DEBIRI). Animals were killed at 1, 6, and 24 h. Irinotecan and SN-38 concentrations were measured at different time points in serum, tumor, and normal liver. RESULTS: Twelve milligrams of irinotecan were injected IV and IA, whereas 6-16.5 mg were injected loaded onto DEBIRI. Normalized serum irinotecan reached a peak of 333 ng/ml (range 198.8-502.5) for IV, 327.1 ng/ml (range 277.1-495.6) for IA, and 189.7 ng/ml (range 111.1-261.9) for DEBIRI (P < 0.001) delivery. The area-under-the-curve value from 10 to 60 min of serum irinotecan concentration was significantly lower for DEBIRI (P = 0.0009). Tumor irinotecan levels for IV, IA, and DEBIRI (in ng/200 mg of tissue followed by ranges in parentheses) were, respectively, 23.6 (0.3-24.9), 36.5 (7.7-1914.1), and 20.2 (2.9-319) at 1 h; 4.2 (1-27.9), 99.3 (46.6-159.5), and 42.1 (11.3-189) at 6 h; and 2.7 (2.5-6.9), 18.3 (1.5-369.1), and 174.4 (3.4-5147.3) at 24 h (P = 0.02). At 24 h, tumor necrosis was 25% (10-30), 60% (40-91.25), and 95% (76.25-95) for IV, IA, and DEBIRI, respectively (P = 0.03). CONCLUSION: Compared with IV or IA, DEBIRI induces lower early serum levels of irinotecan, a high and prolonged intratumoral level of irinotecan, and a greater rate of tumor necrosis at 24 h. Further evaluation of the clinical benefit of DEBIRI is warranted.