148 resultados para Primary health care. Non-transmissible chronic diseases. Assessment of health programs


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nanogenotoxicity is a crucial endpoint in safety testing of nanomaterials as it addresses potential mutagenicity, which has implications for risks of both genetic disease and carcinogenesis. Within the NanoTEST project, we investigated the genotoxic potential of well-characterised nanoparticles (NPs): titanium dioxide (TiO2) NPs of nominal size 20 nm, iron oxide (8 nm) both uncoated (U-Fe3O4) and oleic acid coated (OC-Fe3O4), rhodamine-labelled amorphous silica 25 (Fl-25 SiO2) and 50 nm (Fl-50 SiO) and polylactic glycolic acid polyethylene oxide polymeric NPs - as well as Endorem® as a negative control for detection of strand breaks and oxidised DNA lesions with the alkaline comet assay. Using primary cells and cell lines derived from blood (human lymphocytes and lymphoblastoid TK6 cells), vascular/central nervous system (human endothelial human cerebral endothelial cells), liver (rat hepatocytes and Kupffer cells), kidney (monkey Cos-1 and human HEK293 cells), lung (human bronchial 16HBE14o cells) and placenta (human BeWo b30), we were interested in which in vitro cell model is sufficient to detect positive (genotoxic) and negative (non-genotoxic) responses. All in vitro studies were harmonized, i.e. NPs from the same batch, and identical dispersion protocols (for TiO2 NPs, two dispersions were used), exposure time, concentration range, culture conditions and time-courses were used. The results from the statistical evaluation show that OC-Fe3O4 and TiO2 NPs are genotoxic in the experimental conditions used. When all NPs were included in the analysis, no differences were seen among cell lines - demonstrating the usefulness of the assay in all cells to identify genotoxic and non-genotoxic NPs. The TK6 cells, human lymphocytes, BeWo b30 and kidney cells seem to be the most reliable for detecting a dose-response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: To evaluate the safety and clinical feasibility of focal irreversible electroporation (IRE) of the prostate. METHODS: We assessed the toxicity profile and functional outcomes of consecutive patients undergoing focal IRE for localised prostate cancer in two centres. Eligibility was assessed by multi-parametric magnetic resonance imaging (mpMRI) and targeted and/or template biopsy. IRE was delivered under transrectal ultrasound guidance with two to six electrodes positioned transperineally within the cancer lesion. Complications were recorded and scored accordingly to the NCI Common Terminology Criteria for Adverse Events; the functional outcome was physician reported in all patients with at least 6 months follow-up. A contrast-enhanced MRI 1 week after the procedure was carried out to assess treatment effect with a further mpMRI at 6 months to rule out evidence of residual visible cancer. RESULTS: Overall, 34 patients with a mean age of 65 years (s.d.=±6) and a median PSA of 6.1 ng ml(-1) (interquartile range (IQR)= 4.3-7.7) were included. Nine (26%), 24 (71%) and 1 (3%) men had low, intermediate and high risk disease, respectively (D'Amico criteria). After a median follow-up of 6 months (range 1-24), 12 grade 1 and 10 grade 2 complications occurred. No patient had grade >/= 3 complication. From a functional point of view, 100% (24/24) patients were continent and potency was preserved in 95% (19/20) men potent before treatment. The volume of ablation was a median 12 ml (IQR=5.6-14.5 ml) with the median PSA after 6 months of 3.4 ng ml(-1) (IQR=1.9-4.8 ng ml(-1)). MpMRI showed suspicious residual disease in six patients, of whom four (17%) underwent another form of local treatment. CONCLUSIONS: Focal IRE has a low toxicity profile with encouraging genito-urinary functional outcomes. Further prospective development studies are needed to confirm the functional outcomes and to explore the oncological potential.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans cette étude, nous avons testé la performance diagnostique d'une nouvelle technique d'analyse multiplexée qui permet la détection d'anticorps de différentes spécificités dans la même réaction. En l'absence de gold standard, nous avons choisi de comparer la performance diagnostique de l'analyse avec deux méthodes de référance que sont l'IF et EIA, et avec un consensus déterminé selon une règle de majorité entre les trois méthodes.¦393 sérums analysés par IF, conservés par congélation, ont été décongelés pour être analysés par EIA et BBA. Pour chaque sérum, les anticorps recherchés ont été les anti-VCA (Viral Capsid Antigen) IgM, anti-VCA IgG et anti-EBNA (Epstein-Barr Nuclear Associated) IgG. Les échantillons ont été classés en cinq groupes selon les résultats de l'IF : séronégatifs, infections aiguës, infections anciennes et deux types d'indéterminés.¦Pour chaque méthode, le résultat numérique (index ou titre) des analyses est converti en termes de positif, négatif ou douteux. Pour le résultat de chaque type d'anticorps, un consensus est établi selon une règle de majorité entre les trois méthodes, permettant une interprétation du stade de l'infection. Puis l'interprétation de chacune des méthodes a été comparée au consensus. Nous avons également comparé les trois méthodes les unes aux autres concernant la détection des anticorps.¦Globalement, nous observons une bonne corrélation qualitative entre les trois approches pour détecter les anti-VCA IgG et IgM. Pour pour les anti-EBNA IgG, il y a une divergence notable entre l'IF et les deux autres méthodes, l'IF apparaissant moins sensible que les autres méthodes, résultant en un nombre accru d'interprétations indéterminées du stade de l'infection.¦L'origine de cette divergence ne peut être due à une perte d'anticorps liée au stockage de longue durée des échantillons. En effet, EIA et BBA restent plus sensibles que IF, dont l'analyse a été faite sur des sérums frais.¦Cette divergence ne semble pas non plus être due aux différents antigènes utilisés par les trois méthodes. EIA et BBA utilisent le même antigène recombinant EBNA-1, alors que l'IF utilise des "cellules lymphoïdes choisies pour leur production sélective d'antigènes EBNA". Ces cellules sont probablement des cellules infectées par EBV qui devraient exprimer plus d'antigènes de latence que seul EBNA-1. Cette différence devrait donc plutôt en principe résulter en une meilleure sensibilité de l'IF par rapport aux deux autres méthodes.¦Les anti-EBNA IgG peuvent disparaître chez les patients immunocompromis chez qui se produit une réactivation d'EBV. Nous avons donc recherché le status immunitaire des patients du groupe dont les sérums étaient négatifs pour anti-EBNA IgG en IF et positifs par les autres méthodes: seulement 28 des 70 patients étaient immunocompromis.¦Par conséquent, il est probable que dans la majorité de ces résultats discordants, les anticorps anti-EBNA IgG détectés par BBA et EIA sont de vrais positifs non décelés par l'IF.¦En conclusion, BBA est meilleur que la méthode de référance qu'est l'IF, et est égal à EIA en ce qui concerne la performance diagnostique. En outre, ces deux nouvelles méthodes offrent une économie de temps en raison de manipulations moindres, et ne requièrent aucune formation en microscopie à fluorescence. Elles sont également plus économes en échantillons que IF. BBA a l'avantage de n'avoir besoin que de deux analyses pour donner un diagnostique, alors que IF et EIA ont en besoin d'une par anticorps. Enfin, BBA dispose de contrôles internes permettant de reconnaître les liaisons non antigène-spécifiques des anticorps. Par contre, BBA nécessite l'achat d'un lecteur par cytométrie de flux assez coûteux.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Estimated glomerular filtration rate (eGFR) is an important diagnostic instrument in clinical practice. The National Kidney Foundation-Kidney Disease Quality Initiative (NKF-KDOQI) guidelines do not recommend using formulas developed for adults to estimate GFR in children; however, studies confirming these recommendations are scarce. The aim of our study was to evaluate the accuracy of the new Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formula, the Modification of Diet in Renal Disease (MDRD) formula, and the Cockcroft-Gault formula in children with various stages of chronic kidney disease (CKD). METHODS: A total of 550 inulin clearance (iGFR) measurements for 391 children were analyzed. The cohort was divided into three groups: group 1, with iGFR >90 ml/min/1.73 m(2); group 2, with iGFR between 60 and 90 ml/min/1.73 m(2); group 3, with iGFR of <60 ml/min/1.73 m(2). RESULTS: All formulas overestimate iGFR with a significant bias (p < 0.001), present poor accuracies, and have poor Spearman correlations. For an accuracy of 10 %, only 11, 6, and 27 % of the eGFRs are accurate when using the MDRD, CKD-EPI, and Cockcroft-Gault formulas, respectively. For an accuracy of 30 %, these formulas do not reach the NKF-KDOQI guidelines for validation, with only 25, 20, and 70 % of the eGFRs, respectively, being accurate. CONCLUSIONS: Based on our results, the performances of all of these formulas are unreliable for eGFR in children across all CKD stages and cannot therefore be applied in the pediatric population group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: All patients with extensive resection of the anterolateral chest wall and the sternum followed by reconstruction with methylmethacrylate substitutes were assessed prospectively 6 months after the operation to delineate chest wall integrity with pulmonary function and cine-magnetic resonance imaging. METHODS: Twenty-six patients underwent chest wall reconstruction by use of methylmethacrylate between 1994 and 1998 due to primary tumors in 35%, metastases in 27%, T3 lung cancer in 19%, and debridement for radionecrosis and osteomyelitis in 19% of patients. Three to eight ribs were resected and additional sternum resection was performed in 39% of patients. RESULTS: There was no 30-day mortality. All patients were extubated after the operation without need for reintubation. Prosthesis dislocation occurred in 1 patient and infection in 2 patients during follow-up. Nineteen patients (73%) suffered no restrictions of daily activities. Clinical examination revealed normal shoulder girdle function in 77% of patients. There was no significant difference between preoperative and postoperative FEV1 (forced expiratory volume in 1 second) measurements in patients with lobectomy or wedge resections. Cinemagnetic resonance imaging revealed concordant chest wall movements during respiration in 92% of patients without paradoxical movements or implant dislocations being observed. CONCLUSIONS: Large defects of the anterolateral chest wall and sternum can be reconstructed efficiently with methylmethacrylate substitutes with minimal morbidity and excellent cosmetic and functional outcome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tamoxifen (tam) is a widely used endocrine therapy in the treatment of early and advanced stage breast cancer in women and men. It is a pro-drug having weak affinity with the estrogen receptor and needs to be converted to its main metabolite, endoxifen (endox), to have full anticancer activity. Cytochrome 2D6 (CYP2D6) plays a major role in the metabolism of tamoxifen to endoxifen. It is genetically highly polymorphic and its activity influences profoundly the synthesis of endoxifen and potentially the efficacy of tamoxifen treatment. Genotyping is currently the most widely used approach in studies and also in clinical practice to categorize patients as poor- (PM), intermediate- (IM), extensive- (EM) and ultra rapid-metabolizers (UM). Some clinicians already use genotyping in order to tailor the endocrine therapy of their patients. Owing to the large inter-individual variations in concentrations of the active moitey due to genetic and non-genetic influences renders the predictive value of the test uncertain for an individual patient. A significant number of patients classified as EM or IM by genotyping have indeed relatively low endoxifen levels similar to PMs1. This suggests that genotyping is probably not the opti ma l meth o d f or predi cti ng end oxif en l evels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the role of adipose tissue in the metabolic stress response of critically ill patients, the release of glycerol and lactate by subcutaneous adipose tissue was assessed by means of microdialysis in patients with sepsis or circulatory failure and in healthy subjects. Patients with sepsis had lower plasma free fatty acid concentrations and non-significant elevations of plasma glycerol concentrations, but higher adipose-systemic glycerol concentrations gradients than healthy subjects or patients with circulatory failure, indicating a stimulation of subcutaneous adipose lipolysis. They also had a higher lipid oxidation. Lipid metabolism (adipose-systemic glycerol gradients, lipid oxidation) was not altered in patients with circulatory failure. These observations highlight major differences in lipolysis and lipid utilization between patients with sepsis and circulatory failure. Hyperlactataemia was present in both groups of patients, but the adipose-systemic lactate concentration gradient was not increased, indicating that lactate production by adipose tissue was not involved. This speaks against a role of adipose tissue in the development of hyperlactataemia in critically ill patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The introduction of engineered nanostructured materials into a rapidly increasing number of industrial and consumer products will result in enhanced exposure to engineered nanoparticles. Workplace exposure has been identified as the most likely source of uncontrolled inhalation of engineered aerosolized nanoparticles, but release of engineered nanoparticles may occur at any stage of the lifecycle of (consumer) products. The dynamic development of nanomaterials with possibly unknown toxicological effects poses a challenge for the assessment of nanoparticle induced toxicity and safety.In this consensus document from a workshop on in-vitro cell systems for nanoparticle toxicity testing11Workshop on 'In-Vitro Exposure Studies for Toxicity Testing of Engineered Nanoparticles' sponsored by the Association for Aerosol Research (GAeF), 5-6 September 2009, Karlsruhe, Germany. an overview is given of the main issues concerning exposure to airborne nanoparticles, lung physiology, biological mechanisms of (adverse) action, in-vitro cell exposure systems, realistic tissue doses, risk assessment and social aspects of nanotechnology. The workshop participants recognized the large potential of in-vitro cell exposure systems for reliable, high-throughput screening of nanoparticle toxicity. For the investigation of lung toxicity, a strong preference was expressed for air-liquid interface (ALI) cell exposure systems (rather than submerged cell exposure systems) as they more closely resemble in-vivo conditions in the lungs and they allow for unaltered and dosimetrically accurate delivery of aerosolized nanoparticles to the cells. An important aspect, which is frequently overlooked, is the comparison of typically used in-vitro dose levels with realistic in-vivo nanoparticle doses in the lung. If we consider average ambient urban exposure and occupational exposure at 5mg/m3 (maximum level allowed by Occupational Safety and Health Administration (OSHA)) as the boundaries of human exposure, the corresponding upper-limit range of nanoparticle flux delivered to the lung tissue is 3×10-5-5×10-3μg/h/cm2 of lung tissue and 2-300particles/h/(epithelial) cell. This range can be easily matched and even exceeded by almost all currently available cell exposure systems.The consensus statement includes a set of recommendations for conducting in-vitro cell exposure studies with pulmonary cell systems and identifies urgent needs for future development. As these issues are crucial for the introduction of safe nanomaterials into the marketplace and the living environment, they deserve more attention and more interaction between biologists and aerosol scientists. The members of the workshop believe that further advances in in-vitro cell exposure studies would be greatly facilitated by a more active role of the aerosol scientists. The technical know-how for developing and running ALI in-vitro exposure systems is available in the aerosol community and at the same time biologists/toxicologists are required for proper assessment of the biological impact of nanoparticles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Knowledge of the number of recent HIV infections is important for epidemiologic surveillance. Over the past decade approaches have been developed to estimate this number by testing HIV-seropositive specimens with assays that discriminate the lower concentration and avidity of HIV antibodies in early infection. We have investigated whether this "recency" information can also be gained from an HIV confirmatory assay. METHODS AND FINDINGS: The ability of a line immunoassay (INNO-LIA HIV I/II Score, Innogenetics) to distinguish recent from older HIV-1 infection was evaluated in comparison with the Calypte HIV-1 BED Incidence enzyme immunoassay (BED-EIA). Both tests were conducted prospectively in all HIV infections newly diagnosed in Switzerland from July 2005 to June 2006. Clinical and laboratory information indicative of recent or older infection was obtained from physicians at the time of HIV diagnosis and used as the reference standard. BED-EIA and various recency algorithms utilizing the antibody reaction to INNO-LIA's five HIV-1 antigen bands were evaluated by logistic regression analysis. A total of 765 HIV-1 infections, 748 (97.8%) with complete test results, were newly diagnosed during the study. A negative or indeterminate HIV antibody assay at diagnosis, symptoms of primary HIV infection, or a negative HIV test during the past 12 mo classified 195 infections (26.1%) as recent (< or = 12 mo). Symptoms of CDC stages B or C classified 161 infections as older (21.5%), and 392 patients with no symptoms remained unclassified. BED-EIA ruled 65% of the 195 recent infections as recent and 80% of the 161 older infections as older. Two INNO-LIA algorithms showed 50% and 40% sensitivity combined with 95% and 99% specificity, respectively. Estimation of recent infection in the entire study population, based on actual results of the three tests and adjusted for a test's sensitivity and specificity, yielded 37% for BED-EIA compared to 35% and 33% for the two INNO-LIA algorithms. Window-based estimation with BED-EIA yielded 41% (95% confidence interval 36%-46%). CONCLUSIONS: Recency information can be extracted from INNO-LIA-based confirmatory testing at no additional costs. This method should improve epidemiologic surveillance in countries that routinely use INNO-LIA for HIV confirmation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: We studied human cytomegalovirus (CMV) donor-to-recipient transmission patterns in organ transplantation by analyzing genomic variants on the basis of CMV glycoprotein B (gB) genotyping. METHODS: Organ transplant recipients were included in the study if they had CMV viremia, if they had received an organ from a CMV-seropositive donor, and if there was at least 1 other recipient of an organ from the same donor who developed CMV viremia. Genotypes (gB1-4) were determined by real-time polymerase chain reaction. RESULTS: Forty-seven recipients of organs from 21 donors developed CMV viremia. Twenty-three recipients had a pretransplant donor/recipient (D/R) CMV serostatus of D(+)/R(+), and 24 had a serostatus of D(+)/R(-). The prevalences of genotypes in recipients were as follows: for gB1, 51% (n = 24); for gB2, 19% (n = 9); for gB3, 9% (n = 4); for gB4, 0% (n = 0); and for mixed infection, 21% (n = 10). Recipients of an organ from a common donor had infection with CMV of the same gB genotype in 12 (57%) of 21 instances. Concordance between genotypes was higher among seronegative (i.e., D(+)/R(-)) recipients than among seropositive (D(+)/R(+)) recipients, although discordances resulting from the transmission of multiple strains were seen. In seropositive recipients, transmission of multiple strains from the donor could not be differentiated from reactivation of a recipient's own strains. CONCLUSION: Our analysis of strain concordance among recipients of organs from common donors showed that transmission of CMV has complex dynamic patterns. In seropositive recipients, transmission or reactivation of multiple CMV strains is possible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Summary: To evaluate the role of adipose tissue in the metabolic stress response of critically ill patients, the release of glycerol and lactate by subcutaneous adipose tissue was assessed by means of microdialysis in patients with sepsis or circulatory failure and in healthy subjects. Patients with sepsis had lower plasma free fatty acid concentrations and non-significant elevations of plasma glycerol concentrations, but higher adipose-systemic glycerol concentrations gradients than healthy subjects or patients with circulatory failure, indicating a stimulation of subcutaneous adipose lipolysis. They also had a higher lipid oxidation. Lipid metabolism (adipose-systemic glycerol gradients, lipid oxidation) was not altered in patients with circulatory failure. These observations highlight major differences in lipolysis and lipid utilization between patients with sepsis and circulatory failure. Hyperlactataemia was present in both groups of patients, but the adipose-systemic lactate concentration gradient was not increased, indicating that lactate production by adipose tissue was not involved. This speaks against a role of adipose tissue in the development of hyperlactataemia in critically ill patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le rétinoblastome (Rb) est une tumeur provenant des cellules rétiniennes progénitrices des photorécepteurs. C'est la tumeur pédiatrique maligne la plus fréquente avec une incidence par naissance évaluée entre 1/15Ό00 et 1/20Ό00. Les enfants atteints de Rb sont diagnostiqué dans leur grande majorité avant l'âge de 4 ans, soit le temps nécessaire à la différentiation et à la maturation des photorécepteurs et donc à la disparition de la cellule d'origine du Rb. La survie du patient, la sauvegarde oculaire et le pronostic visuel restent excellents pour autant que le traitement ne soit pas différé. Dans sa variante non héréditaire (60%) le Rb est toujours unilatéral et sporadique. Le Rb héréditaire de transmission dominante autosomique (40%), se décline sous toutes les formes, familiale (10%) ou sporadique (30%), que l'atteinte soit unilatérale ou bilatérale. La majorité des mutations causales sont uniques et distribuées de façon aléatoire sur la totalité du gène RB1 sans région prédisposante. La détection de ces mutations est couteuse et chronophage, tout en présentant un taux de détection relativement bas; surtout dans les cas de Rb sporadiques unilatéraux. Dans le but d'identifier les patients présentant un risque réel de développer un Rb, et de réduire le nombre d'examens sous narcose requis pour le dépistage de la maladie chez les sujets à risque, nous avons développé une stratégie sensible, rapide, efficace et peu couteuse basée sur une analyse de l'haplotype intragénique. Cet algorithme prend en compte a) la perte d'hétérozygotie intratumorale du gène RB1, b) l'origine paternelle préférentielle des nouvelles mutations germinales et c) un risque a priori dérivé des données empiriques de Vogel. Pendant la période allant de janvier 1994 à décembre 2006, nous avons comparé l'apparition de nouveau Rb parmi la fratrie et la descendance de patient atteints au nombre de nouveaux cas attendus calculé par notre algorithme. 134 familles ont été étudiées. L'analyse moléculaire a été effectuée chez 570 personnes dont 99 patients âgés de moins de 4 ans et donc à risque de développer un Rb. Parmi cette cohorte, nous avons observé l'apparition d'un cas de Rb, alors que les risques cumulés a posteriori calculé par notre algorithme prédisait l'apparition de 1.77 nouveau cas. Dans cette étude, nous avons pu valider notre algorithme prédisant la récurrence de Rb chez les parents de 1er degré de patients atteints. Cet outil devrait grandement faciliter le conseil génétique ainsi que le suivi des patients à risque de développer un Rb, surtout dans les cas ou le séquençage direct du gène RB1 n'est pas disponible ou est resté non informatif. - Purpose: Most RBI mutations are unique and distributed throughout the RBI gene. Their detection can be time-consuming and the yield especially low in cases of conservatively-treated sporadic unilateral retinoblas-toma (Rb) patients. In order to identify patients with true risk of developing Rb, and to reduce the number of unnecessary examinations under anesthesia in all other cases, we developed a universal sensitive, efficient and cost-effective strategy based on intragenic haplotype analysis. Methods: This algorithm allows the calculation of the a posteriori risk of developing Rb and takes into account (a) RBI loss of heterozygosity in tumors, (b) preferential paternal origin of new germline mutations, (c) a priori risk derived from empirical data by Vogel, and (d) disease penetrance of 90% in most cases. We report the occurrence of Rb in first degree relatives of patients with sporadic Rb who visited the Jules Gonin Eye Hospital, Lausanne, Switzerland, from January 1994 to December 2006 compared to expected new cases of Rb using our algorithm. Results: A total of 134 families with sporadic Rb were enrolled; testing was performed in 570 individuals and 99 patients younger than 4 years old were identified. We observed one new case of Rb. Using our algorithm, the cumulated total a posteriori risk of recurrence was 1.77. Conclusions: This is the first time that linkage analysis has been validated to monitor the risk of recurrence in sporadic Rb. This should be a useful tool in genetic counseling, especially when direct RBI screening for mutations leaves a negative result or is unavailable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Physical activity (PA) and related energy expenditure (EE) is often assessed by means of a single technique. Because of inherent limitations, single techniques may not allow for an accurate assessment both PA and related EE. The aim of this study was to develop a model to accurately assess common PA types and durations and thus EE in free-living conditions, combining data from global positioning system (GPS) and 2 accelerometers. Methods: Forty-one volunteers participated in the study. First, a model was developed and adjusted to measured EE with a first group of subjects (Protocol I, n = 12) who performed 6 structured and supervised PA. Then, the model was validated over 2 experimental phases with 2 groups (n = 12 and n = 17) performing scheduled (Protocol I) and spontaneous common activities in real-life condition (Protocol II). Predicted EE was compared with actual EE as measured by portable indirect calorimetry. Results: In protocol I, performed PA types could be recognized with little error. The duration of each PA type could be predicted with an accuracy below 1 minute. Measured and predicted EE were strongly associated (r = .97, P < .001). Conclusion: Combining GPS and 2 accelerometers allows for an accurate assessment of PA and EE in free-living situations.