99 resultados para Power Spectral
Resumo:
In this paper, mixed spectral-structural kernel machines are proposed for the classification of very-high resolution images. The simultaneous use of multispectral and structural features (computed using morphological filters) allows a significant increase in classification accuracy of remote sensing images. Subsequently, weighted summation kernel support vector machines are proposed and applied in order to take into account the multiscale nature of the scene considered. Such classifiers use the Mercer property of kernel matrices to compute a new kernel matrix accounting simultaneously for two scale parameters. Tests on a Zurich QuickBird image show the relevance of the proposed method : using the mixed spectral-structural features, the classification accuracy increases of about 5%, achieving a Kappa index of 0.97. The multikernel approach proposed provide an overall accuracy of 98.90% with related Kappa index of 0.985.
Resumo:
PURPOSE: To use measurement by cycling power meters (Pmes) to evaluate the accuracy of commonly used models for estimating uphill cycling power (Pest). Experiments were designed to explore the influence of wind speed and steepness of climb on accuracy of Pest. The authors hypothesized that the random error in Pest would be largely influenced by the windy conditions, the bias would be diminished in steeper climbs, and windy conditions would induce larger bias in Pest. METHODS: Sixteen well-trained cyclists performed 15 uphill-cycling trials (range: length 1.3-6.3 km, slope 4.4-10.7%) in a random order. Trials included different riding position in a group (lead or follow) and different wind speeds. Pmes was quantified using a power meter, and Pest was calculated with a methodology used by journalists reporting on the Tour de France. RESULTS: Overall, the difference between Pmes and Pest was -0.95% (95%CI: -10.4%, +8.5%) for all trials and 0.24% (-6.1%, +6.6%) in conditions without wind (<2 m/s). The relationship between percent slope and the error between Pest and Pmes were considered trivial. CONCLUSIONS: Aerodynamic drag (affected by wind velocity and orientation, frontal area, drafting, and speed) is the most confounding factor. The mean estimated values are close to the power-output values measured by power meters, but the random error is between ±6% and ±10%. Moreover, at the power outputs (>400 W) produced by professional riders, this error is likely to be higher. This observation calls into question the validity of releasing individual values without reporting the range of random errors.
Resumo:
BACKGROUND: Previous studies on childhood cancer and nuclear power plants (NPPs) produced conflicting results. We used a cohort approach to examine whether residence near NPPs was associated with leukaemia or any childhood cancer in Switzerland. METHODS: We computed person-years at risk for children aged 0-15 years born in Switzerland from 1985 to 2009, based on the Swiss censuses 1990 and 2000 and identified cancer cases from the Swiss Childhood Cancer Registry. We geo-coded place of residence at birth and calculated incidence rate ratios (IRRs) with 95% confidence intervals (CIs) comparing the risk of cancer in children born <5 km, 5-10 km and 10-15 km from the nearest NPP with children born >15 km away, using Poisson regression models. RESULTS: We included 2925 children diagnosed with cancer during 21 117 524 person-years of follow-up; 953 (32.6%) had leukaemia. Eight and 12 children diagnosed with leukaemia at ages 0-4 and 0-15 years, and 18 and 31 children diagnosed with any cancer were born <5 km from a NPP. Compared with children born >15 km away, the IRRs (95% CI) for leukaemia in 0-4 and 0-15 year olds were 1.20 (0.60-2.41) and 1.05 (0.60-1.86), respectively. For any cancer, corresponding IRRs were 0.97 (0.61-1.54) and 0.89 (0.63-1.27). There was no evidence of a dose-response relationship with distance (P > 0.30). Results were similar for residence at diagnosis and at birth, and when adjusted for potential confounders. Results from sensitivity analyses were consistent with main results. CONCLUSIONS: This nationwide cohort study found little evidence of an association between residence near NPPs and the risk of leukaemia or any childhood cancer.
Resumo:
Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.
Resumo:
PURPOSE: To report the time course of retinal morphologic changes in a patient with acute retinal pigment epithelitis (ARPE) using spectral domain optical coherence tomography (SD-OCT). METHODS: A 30-year old man was referred for blurred vision of his right eye after five days that appeared suddenly 15 days after recovery from a flu-like syndrome. SD-OCT was performed immediately, followed by fluorescein and infracyanine angiography at eight days and then at three weeks. RESULTS: At presentation, a bubble of sub-macular deposit was observed on the right macula with central golden micronodules in a honeycomb pattern. SD-OCT showed an "anterior dislocation" of all the retinal layers up to the inner/outer segment (IS/OS) line and irregular deposits at the OS level together with thickening of the retinal pigment epithelial (RPE) layer. As visual acuity increased, eight days later, the OCT showed reduction of the sub-retinal deposits and an abnormal hyperflectivity of the sub-retinal and RPE layers was observed. The patient showed a positive serology for picornavirus. DISCUSSION: The acute SD-OCT sections of this patient with ARPE were compared with histological sections of a 35 day old Royal College of Surgeons rat. Similar findings could be observed, with preservation of the IS/OS line and accumulation of debris at the OS level, suggesting that ARPE symptoms could result from a transient phagocytic dysfunction of the RPE at the fovea, inducing reversible accumulation of undigested OS. Picornaviruses comprising enterovirus and coxsachievirus described as being associated with acute chorioretinitis. In this case, it was responsible for ARPE. CONCLUSION: We hypothesize that ARPE syndrome results from a transient dysfunction of RPE, which can occur as a post viral reaction.
Resumo:
Metastatic melanomas are frequently refractory to most adjuvant therapies such as chemotherapies and radiotherapies. Recently, immunotherapies have shown good results in the treatment of some metastatic melanomas. Immune cell infiltration in the tumor has been associated with successful immunotherapy. More generally, tumor infiltrating lymphocytes (TILs) in the primary tumor and in metastases of melanoma patients have been demonstrated to correlate positively with favorable clinical outcomes. Altogether, these findings suggest the importance of being able to identify, quantify and characterize immune infiltration at the tumor site for a better diagnostic and treatment choice. In this paper, we used Fourier Transform Infrared (FTIR) imaging to identify and quantify different subpopulations of T cells: the cytotoxic T cells (CD8+), the helper T cells (CD4+) and the regulatory T cells (T reg). As a proof of concept, we investigated pure populations isolated from human peripheral blood from 6 healthy donors. These subpopulations were isolated from blood samples by magnetic labeling and purities were assessed by Fluorescence Activated Cell Sorting (FACS). The results presented here show that Fourier Transform Infrared (FTIR) imaging followed by supervised Partial Least Square Discriminant Analysis (PLS-DA) allows an accurate identification of CD4+ T cells and CD8+ T cells (>86%). We then developed a PLS regression allowing the quantification of T reg in a different mix of immune cells (e.g. Peripheral Blood Mononuclear Cells (PBMCs)). Altogether, these results demonstrate the sensitivity of infrared imaging to detect the low biological variability observed in T cell subpopulations.
Resumo:
La spectroscopie infrarouge (FTIR) est une technique de choix dans l'analyse des peintures en spray (traces ou bonbonnes de référence), grâce à son fort pouvoir discriminant, sa sensibilité, et ses nombreuses possibilités d'échantillonnage. La comparaison des spectres obtenus est aujourd'hui principalement faite visuellement, mais cette procédure présente des limitations telles que la subjectivité de la prise de décision car celle-ci dépend de l'expérience et de la formation suivie par l'expert. De ce fait, de faibles différences d'intensités relatives entre deux pics peuvent être perçues différemment par des experts, même au sein d'un même laboratoire. Lorsqu'il s'agit de justifier ces différences, certains les expliqueront par la méthode analytique utilisée, alors que d'autres estimeront plutôt qu'il s'agit d'une variabilité intrinsèque à la peinture et/ou à son vécu (par exemple homogénéité, sprayage, ou dégradation). Ce travail propose d'étudier statistiquement les différentes sources de variabilité observables dans les spectres infrarouges, de les identifier, de les comprendre et tenter de les minimiser. Le deuxième objectif principal est de proposer une procédure de comparaison des spectres qui soit davantage transparente et permette d'obtenir des réponses reproductibles indépendamment des experts interrogés. La première partie du travail traite de l'optimisation de la mesure infrarouge et des principaux paramètres analytiques. Les conditions nécessaires afin d'obtenir des spectres reproductibles et minimisant la variation au sein d'un même échantillon (intra-variabilité) sont présentées. Par la suite une procédure de correction des spectres est proposée au moyen de prétraitements et de sélections de variables, afin de minimiser les erreurs systématiques et aléatoires restantes, et de maximiser l'information chimique pertinente. La seconde partie présente une étude de marché effectuée sur 74 bonbonnes de peintures en spray représentatives du marché suisse. Les capacités de discrimination de la méthode FTIR au niveau de la marque et du modèle sont évaluées au moyen d'une procédure visuelle, et comparées à diverses procédures statistiques. Les limites inférieures de discrimination sont testées sur des peintures de marques et modèles identiques mais provenant de différents lots de production. Les résultats ont montré que la composition en pigments était particulièrement discriminante, à cause des étapes de corrections et d'ajustement de la couleur subies lors de la production. Les particularités associées aux peintures en spray présentes sous forme de traces (graffitis, gouttelettes) ont également été testées. Trois éléments sont mis en évidence et leur influence sur le spectre infrarouge résultant testée : 1) le temps minimum de secouage nécessaire afin d'obtenir une homogénéité suffisante de la peinture et, en conséquence, de la surface peinte, 2) la dégradation initiée par le rayonnement ultra- violet en extérieur, et 3) la contamination provenant du support lors du prélèvement. Finalement une étude de population a été réalisée sur 35 graffitis de la région lausannoise et les résultats comparés à l'étude de marché des bonbonnes en spray. La dernière partie de ce travail s'est concentrée sur l'étape de prise de décision lors de la comparaison de spectres deux-à-deux, en essayant premièrement de comprendre la pratique actuelle au sein des laboratoires au moyen d'un questionnaire, puis de proposer une méthode statistique de comparaison permettant d'améliorer l'objectivité et la transparence lors de la prise de décision. Une méthode de comparaison basée sur la corrélation entre les spectres est proposée, et ensuite combinée à une évaluation Bayesienne de l'élément de preuve au niveau de la source et au niveau de l'activité. Finalement des exemples pratiques sont présentés et la méthodologie est discutée afin de définir le rôle précis de l'expert et des statistiques dans la procédure globale d'analyse des peintures. -- Infrared spectroscopy (FTIR) is a technique of choice for analyzing spray paint speciments (i.e. traces) and reference samples (i.e. cans seized from suspects) due to its high discriminating power, sensitivity and sampling possibilities. The comparison of the spectra is currently carried out visually, but this procedure has limitations such as the subjectivity in the decision due to its dependency on the experience and training of the expert. This implies that small differences in the relative intensity of two peaks can be perceived differently by experts, even between analysts working in the same laboratory. When it comes to justifying these differences, some will explain them by the analytical technique, while others will estimate that the observed differences are mostly due to an intrinsic variability from the paint sample and/or its acquired characteristics (for example homogeneity, spraying, or degradation). This work proposes to statistically study the different sources of variability observed in infrared spectra, to identify them, understand them and try to minimize them. The second goal is to propose a procedure for spectra comparison that is more transparent, and allows obtaining reproducible answers being independent from the expert. The first part of the manuscript focuses on the optimization of infrared measurement and on the main analytical parameters. The necessary conditions to obtain reproducible spectra with a minimized variation within a sample (intra-variability) are presented. Following that a procedure of spectral correction is then proposed using pretreatments and variable selection methods, in order to minimize systematic and random errors, and increase simultaneously relevant chemical information. The second part presents a market study of 74 spray paints representative of the Swiss market. The discrimination capabilities of FTIR at the brand and model level are evaluated by means of visual and statistical procedures. The inferior limits of discrimination are tested on paints coming from the same brand and model, but from different production batches. The results showed that the pigment composition was particularly discriminatory, because of the corrections and adjustments made to the paint color during its manufacturing process. The features associated with spray paint traces (graffitis, droplets) were also tested. Three elements were identified and their influence on the resulting infrared spectra were tested: 1) the minimum shaking time necessary to obtain a sufficient homogeneity of the paint and subsequently of the painted surface, 2) the degradation initiated by ultraviolet radiation in an exterior environment, and 3) the contamination from the support when paint is recovered. Finally a population study was performed on 35 graffitis coming from the city of Lausanne and surroundings areas, and the results were compared to the previous market study of spray cans. The last part concentrated on the decision process during the pairwise comparison of spectra. First, an understanding of the actual practice among laboratories was initiated by submitting a questionnaire. Then, a proposition for a statistical method of comparison was advanced to improve the objectivity and transparency during the decision process. A method of comparison based on the correlation between spectra is proposed, followed by the integration into a Bayesian framework at both source and activity levels. Finally, some case examples are presented and the recommended methodology is discussed in order to define the role of the expert as well as the contribution of the tested statistical approach within a global analytical sequence for paint examinations.