178 resultados para Pet-Vet


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to compare myocardial blood flow (MBF) and myocardial flow reserve (MFR) estimates from rubidium-82 positron emission tomography ((82)Rb PET) data using 10 software packages (SPs) based on 8 tracer kinetic models. BACKGROUND: It is unknown how MBF and MFR values from existing SPs agree for (82)Rb PET. METHODS: Rest and stress (82)Rb PET scans of 48 patients with suspected or known coronary artery disease were analyzed in 10 centers. Each center used 1 of 10 SPs to analyze global and regional MBF using the different kinetic models implemented. Values were considered to agree if they simultaneously had an intraclass correlation coefficient >0.75 and a difference <20% of the median across all programs. RESULTS: The most common model evaluated was the Ottawa Heart Institute 1-tissue compartment model (OHI-1-TCM). MBF values from 7 of 8 SPs implementing this model agreed best. Values from 2 other models (alternative 1-TCM and Axially distributed) also agreed well, with occasional differences. The MBF results from other models (e.g., 2-TCM and retention) were less in agreement with values from OHI-1-TCM. CONCLUSIONS: SPs using the most common kinetic model-OHI-1-TCM-provided consistent results in measuring global and regional MBF values, suggesting that they may be used interchangeably to process data acquired with a common imaging protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the past decade, PET and PET/CT have been widely studied for myocardial perfusion imaging. Several studies demonstrated the incremental value of PET for the diagnostic and prognostic assessment of patients with coronary artery disease. Moreover, PET allows for non-invasively quantifying myocardial blood flow and myocardial flow reserve, that both are recognized as surrogate marker of cardiac event free survival. By enabling the exploration of epicardial disease and the microvasculature, PET constitutes a unique tool to study pathophysiogical mechanisms leading to atherosclerosis genesis. The recent emergence of high-tech hybrid machines may even provide further incremental information about coronary function and morphology. By taking the best of each modality, a better assessment of patients with coronary artery disease is expected. (C) 2011 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le présent travail a eu comme but la comparaison de la performance de deux méthodes d'imagerie diagnostique pour la détection de métastases hépatiques du mélanome uvéal : la tomographie d'émission par positons au F-18-fluorodésoxyglucose (TEP FDG) couplée à la tomodensitométrie (TDM) et l'imagerie par résonance magnétique (IRM). Dans cette étude rétrospective, nous avons analysé les données radiologiques de patients inclus dans une étude multicentrique randomisée de phase III de l'Uveal Melanoma Group of the European Organization for Research and Treatment of Cancer (EORTC). L'IRM s'est révélée nettement plus sensible que le FDG-PET/CT pour mettre en évidence les métastases hépatiques notamment de taille infra-centimétrique. Néanmoins, l'analyse des changements de l'accumulation du traceur métabolique par les métastases hépatiques au cours du traitement suggère la possibilité d'évaluer, de manière précoce, la réponse des métastases hépatiques à la chimiothérapie. Le nombre de cas étudiés est trop faible pour déterminer la précision et la valeur clinique d'une telle évaluation mais les résultats obtenus dans cette étude pilote justifient une étude plus étendue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation of new techniques of imaging in the daily practice of the radiation oncologist is a major advance in these last 10 years. This allows optimizing the therapeutic intervals and locoregional control of the disease while limiting side effects. Among them, positron emission tomography (PET) offers an opportunity to the clinician to obtain data relative to the tumoral biological mechanisms, while benefiting from the morphological images of the computed tomography (CT) scan. Recently hybrid PET/CT has been developed and numerous studies aimed at optimizing its use in the planning, the evaluation of the treatment response and the prognostic value. The choice of the radiotracer (according to the type of cancer and to the studied biological mechanism) and the various methods of tumoral delineation, require a regular update to optimize the practices. We propose throughout this article, an exhaustive review of the published researches (and in process of publication) until December 2011, as user guide of PET/CT in all the aspects of the modern radiotherapy (from the diagnosis to the follow-up): biopsy guiding, optimization of treatment planning and dosimetry, evaluation of tumor response and prognostic value, follow-up and early detection of recurrence versus tumoral necrosis. In a didactic purpose, each of these aspects is approached by primary tumoral location, and illustrated with representative iconographic examples. The current contribution of PET/CT and its perspectives of development are described to offer to the radiation oncologist a clear and up to date reading in this expanding domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte Lié au vieillissement et à la sédentarisation de la population, ainsi qu'à la chronicisation du cancer, l'emploi de cathéters veineux centraux permanents (CVCP) n'a cessé d'augmenter. La complication majeure de ces dispositifs, induisant de forts taux de morbi-mortalité, est l'infection. Actuellement, le diagnostic de ces infections reste surtout basé sur la clinique et les hémocultures. Lorsque le doute persiste, une ablation chirurgicale suivie de la mise en culture des prélèvements chirurgicaux et du cathéter permettent de poser le diagnostic. En clinique, après ces examens, nous constatons que seule la moitié des cathéters retirés étaient réellement infectés. Alors que la tomographie par émission de positons fusionnée à la tomographie (PET/CT) a montré de bons résultats dans la détection des infections chroniques, la valeur diagnostique du PET/CT au fluorodeoxyglucose marqué au 18F (18F-FDG) pour les infections de CVCP n'a encore jamais été déterminée dans une étude prospective. Objectifs Au travers de cette étude prospective, ouverte et monocentrique, nous chercherons à connaître la valeur diagnostique du PET/CT au 18F-FDG dans la détection d'infections de CVCP et ainsi d'en déterminer son utilité. Nous essaierons aussi de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles (paramètres cliniques et culture du liquide d'aspiration), afin de se déterminer sur l'éventuelle utilité diagnostique de celui-ci. Méthodes Cadre : Etude prospective d'au moins 20 patients, avec 2 groupes contrôles d'au moins 10 patients ayant chacun respectivement une faible et une forte probabilité d'infection, soit au moins 40 patients au total. Population : patients adultes avec CVCP devant être retiré. Cette étude prévoit un examen PET/CT au 18F-FDG effectué auprès de patients nécessitant une ablation de CVCP sur suspicion d'infection, sans confirmation possible par les moyens diagnostiques non chirurgicaux. Deux acquisitions seront réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Le groupe contrôle à faible probabilité d'infection, sera formé de patients bénéficiant de l'ablation définitive d'un CVCP pour fin de traitement durant le laps de temps de l'étude, et ayant bénéficié au préalable d'un examen PET/CT pour raison X. Après avoir retiré chirurgicalement le CVCP, nous utiliserons la culture microbiologique des deux extrémités du CVCP comme étalon d'or (gold standard) de l'infection. Le groupe contrôle à forte probabilité d'infection sera formé de patients nécessitant une ablation de CVCP sur infection de CVCP confirmée par les moyens diagnostiques non chirurgicaux (culture positive du liquide de l'aspiration). Lors de l'examen PET/CT, ces patients auront aussi deux acquisitions réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Les résultats de ces examens seront évalués par deux spécialistes en médecine nucléaire qui détermineront le niveau de suspicion de l'infection sur une échelle de Likert allant de I à V, sur la base du nombre de foyers, de la localisation du foyer, de l'intensité de la captation de 18F-FDG au voisinage du cathéter et du rapport tissu/arrière-plan. Par la suite, nous retirerons chirurgicalement le CVCP. Nous utiliserons la culture microbiologique du pus (si présent), des deux extrémités du CVCP ainsi que l'histologie des tissus formant un tunnel autour du cathéter comme étalon d'or de l'infection. Les résultats seront analysés à l'aide de courbes ROC (Receiver Operating Characteristic) afin de déterminer la valeur diagnostique du PET/CT dans l'infection de CVCP. Les résultats des examens des patients avec suspicion clinique d'infection seront ensuite analysés séparément, afin de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles. Résultats escomptés Ce projet veut chercher à savoir si le PET/CT au 18F-FDG peut être un moyen diagnostique valide dans les infections de CVCP, s'avérer utile lorsque les autres moyens diagnostiques sont non conclusifs. Plus-value escomptée Actuellement, lors d'incertitude sur le diagnostic d'infection de CVCP, une opération chirurgicale est effectuée à titre préventif afin d'enlever le cathéter en cause, cependant seulement la moitié de ces cathéters sont réellement infectés en pratique. Le PET/CT au 18F-FDG, grâce à sa sensibilité élevée et probablement une bonne valeur prédictive négative, pourrait éviter à une partie des patients un retrait inutile du cathéter, diminuant ainsi les risques chirurgicaux et les coûts liés à de telles opérations, tout en préservant le capital d'accès vasculaire futur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to compare multidetector CT (MDCT), MRI, and FDG PET/CT imaging for the detection of peritoneal carcinomatosis (PC) in ovarian cancer. PATIENTS AND METHODS: Fifteen women with ovarian cancer and suspected PC underwent MDCT, MRI, and FDG PET/CT, shortly before surgery. Nine abdominopelvic regions were defined according to the peritoneal cancer index. We applied lesion size scores on MDCT and MR and measured FDG PET/CT standard uptake. We blindly read MDCT, MR, and PET/CT before joint review and comparison with histopathology. Receiver operating characteristics analysis was performed. RESULTS: Ten women had PC (67%). Altogether, 135 abdominopelvic sites were compared. Multidetector CT, MRI, and FDG PET/CT had a sensitivity of 96%, 98%, and 95%, and specificity was 92%, 84%, and 96%, respectively. Corresponding receiver operating characteristics area was 0.94, 0.90, and 0.96, respectively, without any significant differences between them (P = 0.12). FDG PET/CT detected supradiaphragmatic disease in 3 women (20%) not seen by MDCT or MRI. CONCLUSIONS: Although MRI had the highest sensitivity and FDG PET/CT had the highest specificity, no significant differences were found between the 3 techniques. Thus, MDCT, as the fastest, most economical, and most widely available modality, is the examination of choice, if a stand-alone technique is required. If inconclusive, PET/CT or MRI may offer additional insights. Whole-body FDG PET/CT may be more accurate for supradiaphragmatic metastatic extension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-frequency oscillations in the gamma-band reflect rhythmic synchronization of spike timing in active neural networks. The modulation of gamma oscillations is a widely established mechanism in a variety of neurobiological processes, yet its neurochemical basis is not fully understood. Modeling, in-vitro and in-vivo animal studies suggest that gamma oscillation properties depend on GABAergic inhibition. In humans, search for evidence linking total GABA concentration to gamma oscillations has led to promising -but also to partly diverging- observations. Here, we provide the first evidence of a direct relationship between the density of GABAA receptors and gamma oscillatory gamma responses in human primary visual cortex (V1). By combining Flumazenil-PET (to measure resting-levels of GABAA receptor density) and MEG (to measure visually-induced gamma oscillations), we found that GABAA receptor densities correlated positively with the frequency and negatively with amplitude of visually-induced gamma oscillations in V1. Our findings demonstrate that gamma-band response profiles of primary visual cortex across healthy individuals are shaped by GABAA-receptor-mediated inhibitory neurotransmission. These results bridge the gap with in-vitro and animal studies and may have future clinical implications given that altered GABAergic function, including dysregulation of GABAA receptors, has been related to psychiatric disorders including schizophrenia and depression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To compare the prognostic value of different anatomical and functional metabolic parameters determined using [(18)F]FDG-PET/CT with other clinical and pathological prognostic parameters in cervical cancer (CC). METHODS: Thirty-eight patients treated with standard curative doses of chemo-radiotherapy (CRT) underwent pre- and post-therapy [(18)F]FDG-PET/CT. [(18)F]FDG-PET/CT parameters including mean tumor standardized uptake values (SUV), metabolic tumor volume (MTV) and tumor glycolytic volume (TGV) were measured before the start of CRT. The post-treatment tumor metabolic response was evaluated. These parameters were compared to other clinical prognostic factors. Survival curves were estimated by using the Kaplan-Meier method. Cox regression analysis was performed to determine the independent contribution of each prognostic factor. RESULTS: After 37 months of median follow-up (range, 12-106), overall survival (OS) was 71 % [95 % confidence interval (CI), 54-88], disease-free survival (DFS) 61 % [95 % CI, 44-78] and loco-regional control (LRC) 76 % [95 % CI, 62-90]. In univariate analyses the [(18)F]FDG-PET/CT parameters unfavorably influencing OS, DFS and LRC were pre-treatment TGV-cutoff ≥562 (37 vs. 76 %, p = 0.01; 33 vs. 70 %, p = 0.002; and 55 vs. 83 %, p = 0.005, respectively), mean pre-treatment tumor SUV cutoff ≥5 (57 vs. 86 %, p = 0.03; 36 vs. 88 %, p = 0.004; 65 vs. 88 %, p = 0.04, respectively) and a partial tumor metabolic response after treatment (9 vs. 29 %, p = 0.0008; 0 vs. 83 %, p < 0.0001; 22 vs. 96 %, p < 0.0001, respectively). After multivariate analyses a partial tumor metabolic response after treatment remained as an independent prognostic factor unfavorably influencing DFS and LRC (RR 1:7.7, p < 0.0001, and RR 1:22.6, p = 0.0003, respectively) while the pre-treatment TGV-cutoff ≥562 negatively influenced OS and DFS (RR 1:2, p = 0.03, and RR 1:2.75, p = 0.05). CONCLUSIONS: Parameters capturing the pre-treatment glycolytic volume and metabolic activity of [(18)F]FDG-positive disease provide important prognostic information in patients with CC treated with CRT. The post-therapy [(18)F]FDG-PET/CT uptake (partial tumor metabolic response) is predictive of disease outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Most peripheral T-cell lymphoma (PTCL) patients have a poor outcome and the identification of prognostic factors at diagnosis is needed. PATIENTS AND METHODS: The prognostic impact of total metabolic tumor volume (TMTV0), measured on baseline [(18)F]2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography, was evaluated in a retrospective study including 108 PTCL patients (27 PTCL not otherwise specified, 43 angioimmunoblastic T-cell lymphomas and 38 anaplastic large-cell lymphomas). All received anthracycline-based chemotherapy. TMTV0 was computed with the 41% maximum standardized uptake value threshold method and an optimal cut-off point for binary outcomes was determined and compared with others prognostic factors. RESULTS: With a median follow-up of 23 months, 2-year progression-free survival (PFS) was 49% and 2-year overall survival (OS) was 67%. High TMTV0 was significantly associated with a worse prognosis. At 2 years, PFS was 26% in patients with a high TMTV0 (>230 cm(3), n = 53) versus 71% for those with a low TMTV0, [P < 0.0001, hazard ratio (HR) = 4], whereas OS was 50% versus 80%, respectively, (P = 0.0005, HR = 3.1). In multivariate analysis, TMTV0 was the only significant independent parameter for both PFS and OS. TMTV0, combined with PIT, discriminated even better than TMTV0 alone, patients with an adverse outcome (TMTV0 >230 cm(3) and PIT >1, n = 33,) from those with good prognosis (TMTV0 ≤230 cm(3) and PIT ≤1, n = 40): 19% versus 73% 2-year PFS (P < 0.0001) and 43% versus 81% 2-year OS, respectively (P = 0.0002). Thirty-one patients (other TMTV0-PIT combinations) had an intermediate outcome, 50% 2-year PFS and 68% 2-year OS. CONCLUSION: TMTV0 appears as an independent predictor of PTCL outcome. Combined with PIT, it could identify different risk categories at diagnosis and warrants further validation as a prognostic marker.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Obstructive sleep apnea syndrome (OSA) increases the risk of cardiovascular disease. We aimed at evaluating the effect of continuous positive airway pressure (CPAP) treatment on coronary endothelium-dependent vasoreactivity in OSA patients by quantifying myocardial blood flow (MBF) response to cold pressure testing (CPT). METHODS: In the morning after polysomnography (PSG), all participants underwent a dynamic (82)Rb cardiac positron emitting tomography/computed tomography (PET/CT) scan at rest, during CPT and adenosine stress. PSG and PET/CT were repeated at least 6 weeks after initiating CPAP treatment. OSA patients were compared to controls and according to response to CPAP. Patients' characteristics and PSG parameters were used to determine predictors of CPT-MBF. RESULTS: Thirty-two untreated OSA patients (age 58 ± 13 years, 27 men) and 9 controls (age 62 ± 5 years, 4 men) were enrolled. At baseline, compared to controls (apnea-hypopnea index (AHI) = 5.3 ± 2.6/h), untreated OSA patients (AHI = 48.6 ± 19.7/h) tend to have a lower CPT-MBF (1.1 ± 0.2 mL/min/g vs. 1.3 ± 0.4 mL/min/g, p = 0.09). After initiating CPAP, CPT-MBF was not different between well-treated patients (AHI <10/h) and controls (1.3 ± 0.3 mL/min/g vs. 1.3 ± 0.4 mL/min/g, p = 0.83), but it was lower for insufficiently treated patients (AHI ≥10/h) (0.9 ± 0.2 mL/min/g vs. 1.3 ± 0.4 mL/min/g, p = 0.0045). CPT-MBF was also higher in well-treated than in insufficiently treated patients (1.3 ± 0.3 mL/min/g vs. 0.9 ± 0.2 mL/min/g, p = 0.001). Mean nocturnal oxygen saturation (β = -0.55, p = 0.02) and BMI (β = -0.58, p = 0.02) were independent predictors of CPT-MBF in OSA patients. CONCLUSIONS: Coronary endothelial vasoreactivity is impaired in insufficiently treated OSA patients compared to well-treated patients and controls, confirming the need for CPAP optimization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: For the past decade (18)F-fluoro-ethyl-l-tyrosine (FET) and (18)F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) have been used for the assessment of patients with brain tumor. However, direct comparison studies reported only limited numbers of patients. Our purpose was to compare the diagnostic performance of FET and FDG-PET. METHODS: We examined studies published between January 1995 and January 2015 in the PubMed database. To be included the study should: (i) use FET and FDG-PET for the assessment of patients with isolated brain lesion and (ii) use histology as the gold standard. Analysis was performed on a per patient basis. Study quality was assessed with STARD and QUADAS criteria. RESULTS: Five studies (119 patients) were included. For the diagnosis of brain tumor, FET-PET demonstrated a pooled sensitivity of 0.94 (95% CI: 0.79-0.98) and pooled specificity of 0.88 (95% CI: 0.37-0.99), with an area under the curve of 0.96 (95% CI: 0.94-0.97), a positive likelihood ratio (LR+) of 8.1 (95% CI: 0.8-80.6), and a negative likelihood ratio (LR-) of 0.07 (95% CI: 0.02-0.30), while FDG-PET demonstrated a sensitivity of 0.38 (95% CI: 0.27-0.50) and specificity of 0.86 (95% CI: 0.31-0.99), with an area under the curve of 0.40 (95% CI: 0.36-0.44), an LR+ of 2.7 (95% CI: 0.3-27.8), and an LR- of 0.72 (95% CI: 0.47-1.11). Target-to-background ratios of either FDG or FET, however, allow distinction between low- and high-grade gliomas (P > .11). CONCLUSIONS: For brain tumor diagnosis, FET-PET performed much better than FDG and should be preferred when assessing a new isolated brain tumor. For glioma grading, however, both tracers showed similar performances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several analysis software packages for myocardial blood flow (MBF) quantification from cardiac PET studies exist, but they have not been compared using concordance analysis, which can characterize precision and bias separately. Reproducible measurements are needed for quantification to fully develop its clinical potential. METHODS: Fifty-one patients underwent dynamic Rb-82 PET at rest and during adenosine stress. Data were processed with PMOD and FlowQuant (Lortie model). MBF and myocardial flow reserve (MFR) polar maps were quantified and analyzed using a 17-segment model. Comparisons used Pearson's correlation ρ (measuring precision), Bland and Altman limit-of-agreement and Lin's concordance correlation ρc = ρ·C b (C b measuring systematic bias). RESULTS: Lin's concordance and Pearson's correlation values were very similar, suggesting no systematic bias between software packages with an excellent precision ρ for MBF (ρ = 0.97, ρc = 0.96, C b = 0.99) and good precision for MFR (ρ = 0.83, ρc = 0.76, C b = 0.92). On a per-segment basis, no mean bias was observed on Bland-Altman plots, although PMOD provided slightly higher values than FlowQuant at higher MBF and MFR values (P < .0001). CONCLUSIONS: Concordance between software packages was excellent for MBF and MFR, despite higher values by PMOD at higher MBF values. Both software packages can be used interchangeably for quantification in daily practice of Rb-82 cardiac PET.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neural stem cells have been proposed as a new and promising treatment modality in various pathologies of the central nervous system, including malignant brain tumors. However, the underlying mechanism by which neural stem cells target tumor areas remains elusive. Monitoring of these cells is currently done by use of various modes of molecular imaging, such as optical imaging, magnetic resonance imaging and positron emission tomography, which is a novel technology for visualizing metabolism and signal transduction to gene expression. In this new context, the microenvironment of (malignant) brain tumors and the blood-brain barrier gains increased interest. The authors of this review give a unique overview of the current molecular-imaging techniques used in different therapeutic experimental brain tumor models in relation to neural stem cells. Such methods for molecular imaging of gene-engineered neural stem/progenitor cells are currently used to trace the location and temporal level of expression of therapeutic and endogenous genes in malignant brain tumors, closing the gap between in vitro and in vivo integrative biology of disease in neural stem cell transplantation.