196 resultados para Non-invasive ventilation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION/OBJECTIVES: Detection rates for adenoma and early colorectal cancer (CRC) are insufficient due to low compliance towards invasive screening procedures, like colonoscopy.Available non-invasive screening tests have unfortunately low sensitivity and specificity performances.Therefore, there is a large unmet need calling for a cost-effective, reliable and non-invasive test to screen for early neoplastic and pre-neoplastic lesions AIMS & Methods: The objective is to develop a screening test able to detect early CRCs and adenomas.This test is based on a nucleic acids multi-gene assay performed on peripheral blood mononuclear cells (PBMCs).A colonoscopy-controlled feasibility study was conducted on 179 subjects.The first 92 subjects was used as training set to generate a statistical significant signature.Colonoscopy revealed 21 subjects with CRC,30 with adenoma bigger than 1 cm and 41 with no neoplastic or inflammatory lesions.The second group of 48 subjects (controls, CRC and polyps) was used as a test set and will be kept blinded for the entire data analysis.To determine the organ and disease specificity 38 subjects were used:24 with inflammatory bowel disease (IBD),14 with other cancers than CRC (OC).Blood samples were taken from each patient the day of the colonoscopy and PBMCs were purified. Total RNA was extracted following standard procedures.Multiplex RT-qPCR was applied on 92 different candidate biomarkers.Different univariate and multivariate statistical methods were applied on these candidates and among them 60 biomarkers with significant p-values (<0.01) were selected.These biomarkers are involved in several different biological functions as cellular movement,cell signaling and interaction,tissue and cellular development,cancer and cell growth and proliferation.Two distinct biomarker signatures are used to separate patients without lesion from those with cancer or with adenoma, named COLOX CRC and COLOX POL respectively.COLOX performances were validated using random resampling method, bootstrap. RESULTS: COLOX CRC and POL tests successfully separate patients without lesions from those with CRC (Se 67%,Sp 93%,AUC 0.87) and from those with adenoma bigger than 1cm (Se 63%,Sp 83%,AUC 0.77),respectively. 6/24 patients in the IBD group and 1/14 patients in the OC group have a positive COLOX CRC CONCLUSION: The two COLOX tests demonstrated a high sensitivity and specificity to detect the presence of CRCs and adenomas bigger than 1 cm.A prospective, multicenter, pivotal study is underway in order to confirm these promising results in a larger cohort.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUME Durant les dernières années, les méthodes électriques ont souvent été utilisées pour l'investigation des structures de subsurface. L'imagerie électrique (Electrical Resistivity Tomography, ERT) est une technique de prospection non-invasive et spatialement intégrée. La méthode ERT a subi des améliorations significatives avec le développement de nouveaux algorithmes d'inversion et le perfectionnement des techniques d'acquisition. La technologie multicanale et les ordinateurs de dernière génération permettent la collecte et le traitement de données en quelques heures. Les domaines d'application sont nombreux et divers: géologie et hydrogéologie, génie civil et géotechnique, archéologie et études environnementales. En particulier, les méthodes électriques sont souvent employées dans l'étude hydrologique de la zone vadose. Le but de ce travail est le développement d'un système de monitorage 3D automatique, non- invasif, fiable, peu coûteux, basé sur une technique multicanale et approprié pour suivre les variations de résistivité électrique dans le sous-sol lors d'événements pluvieux. En raison des limitations techniques et afin d'éviter toute perturbation physique dans la subsurface, ce dispositif de mesure emploie une installation non-conventionnelle, où toutes les électrodes de courant sont placées au bord de la zone d'étude. Le dispositif le plus approprié pour suivre les variations verticales et latérales de la résistivité électrique à partir d'une installation permanente a été choisi à l'aide de modélisations numériques. Les résultats démontrent que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle et plus apte à détecter les variations latérales et verticales de la résistivité électrique, et cela malgré la configuration non-conventionnelle des électrodes. Pour tester l'efficacité du système proposé, des données de terrain ont été collectées sur un site d'étude expérimental. La technique de monitorage utilisée permet de suivre le processus d'infiltration 3D pendant des événements pluvieux. Une bonne corrélation est observée entre les résultats de modélisation numérique et les données de terrain, confirmant par ailleurs que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle. La nouvelle technique de monitorage 3D de résistivité électrique permet de caractériser les zones d'écoulement préférentiel et de caractériser le rôle de la lithologie et de la pédologie de manière quantitative dans les processus hydrologiques responsables d'écoulement de crue. ABSTRACT During the last years, electrical methods were often used for the investigation of subsurface structures. Electrical resistivity tomography (ERT) has been reported to be a useful non-invasive and spatially integrative prospecting technique. The ERT method provides significant improvements, with the developments of new inversion algorithms, and the increasing efficiency of data collection techniques. Multichannel technology and powerful computers allow collecting and processing resistivity data within few hours. Application domains are numerous and varied: geology and hydrogeology, civil engineering and geotechnics, archaeology and environmental studies. In particular, electrical methods are commonly used in hydrological studies of the vadose zone. The aim of this study was to develop a multichannel, automatic, non-invasive, reliable and inexpensive 3D monitoring system designed to follow electrical resistivity variations in soil during rainfall. Because of technical limitations and in order to not disturb the subsurface, the proposed measurement device uses a non-conventional electrode set-up, where all the current electrodes are located near the edges of the survey grid. Using numerical modelling, the most appropriate arrays were selected to detect vertical and lateral variations of the electrical resistivity in the framework of a permanent surveying installation system. The results show that a pole-dipole array has a better resolution than a pole-pole array and can successfully follow vertical and lateral resistivity variations despite the non-conventional electrode configuration used. Field data are then collected at a test site to assess the efficiency of the proposed monitoring technique. The system allows following the 3D infiltration processes during a rainfall event. A good correlation between the results of numerical modelling and field data results can be observed since the field pole-dipole data give a better resolution image than the pole-pole data. The new device and technique makes it possible to better characterize the zones of preferential flow and to quantify the role of lithology and pedology in flood- generating hydrological processes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As an emerging alternative to DXA, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the non invasive assessment of fracture risk in the management of osteoporosis. While the potential of QUS in the management of osteoporosis have been highly recognized by the scientific community and granted by the majority of the international bone disease organizations, it becomes important to develop strategies how to use ultrasound clinically. Our paper is highlighting Swiss operational clinical propositions for 2 QUS devices sold in Switzerland, on how to use the QUS in the management of osteoporosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The investigation of perceptual and cognitive functions with non-invasive brain imaging methods critically depends on the careful selection of stimuli for use in experiments. For example, it must be verified that any observed effects follow from the parameter of interest (e.g. semantic category) rather than other low-level physical features (e.g. luminance, or spectral properties). Otherwise, interpretation of results is confounded. Often, researchers circumvent this issue by including additional control conditions or tasks, both of which are flawed and also prolong experiments. Here, we present some new approaches for controlling classes of stimuli intended for use in cognitive neuroscience, however these methods can be readily extrapolated to other applications and stimulus modalities. Our approach is comprised of two levels. The first level aims at equalizing individual stimuli in terms of their mean luminance. Each data point in the stimulus is adjusted to a standardized value based on a standard value across the stimulus battery. The second level analyzes two populations of stimuli along their spectral properties (i.e. spatial frequency) using a dissimilarity metric that equals the root mean square of the distance between two populations of objects as a function of spatial frequency along x- and y-dimensions of the image. Randomized permutations are used to obtain a minimal value between the populations to minimize, in a completely data-driven manner, the spectral differences between image sets. While another paper in this issue applies these methods in the case of acoustic stimuli (Aeschlimann et al., Brain Topogr 2008), we illustrate this approach here in detail for complex visual stimuli.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The stiffness of tumor cells varies during cancer progression. In particular, metastatic carcinoma cells analyzed by Atomic Force Microscopy (AFM) appear softer than non-invasive and normal cells. Here we examined by AFM how the stiffness of melanoma cells varies during progression from non-invasive Radial Growth Phase (RGP) to invasive Vertical Growth Phase (VGP) and to metastatic tumors. We show that transformation of melanocytes to RGP and to VGP cells is characterized by decreased cell stiffness. However, further progression to metastatic melanoma is accompanied by increased cell stiffness and the acquisition of higher plasticity by tumor cells, which is manifested by their ability to greatly augment or reduce their stiffness in response to diverse adhesion conditions. We conclude that increased plasticity, rather than decreased stiffness as suggested for other tumor types, is a marker of melanoma malignancy. These findings advise caution about the potential use of AFM for melanoma diagnosis. FROM THE CLINICAL EDITOR: This study investigates the changes to cellular stiffness in metastatic melanoma cells examined via atomic force microscopy. The results demonstrate that increased plasticity is a marker of melanoma malignancy, as opposed to decreased stiffness.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Drug delivery is one of the most common clinical routines in hospitals, and is critical to patients' health and recovery. It includes a decision making process in which a medical doctor decides the amount (dose) and frequency (dose interval) on the basis of a set of available patients' feature data and the doctor's clinical experience (a priori adaptation). This process can be computerized in order to make the prescription procedure in a fast, objective, inexpensive, non-invasive and accurate way. This paper proposes a Drug Administration Decision Support System (DADSS) to help clinicians/patients with the initial dose computing. The system is based on a Support Vector Machine (SVM) algorithm for estimation of the potential drug concentration in the blood of a patient, from which a best combination of dose and dose interval is selected at the level of a DSS. The addition of the RANdom SAmple Consensus (RANSAC) technique enhances the prediction accuracy by selecting inliers for SVM modeling. Experiments are performed for the drug imatinib case study which shows more than 40% improvement in the prediction accuracy compared with previous works. An important extension to the patient features' data is also proposed in this paper.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This prospective study compares repetitive thick-slab single-shot projection magnetic resonance cholangiopancreatography (MRCP) with endoscopic ultrasonography (EUS) for the detection of choledocholithiasis. Fifty-seven consecutive patients (36 women, mean age 61) referred for suspected choledocholithiasis underwent MRCP, followed by EUS. Each procedure was performed by different operators blinded to the results of the other investigation. MR technique included a turbo spin-echo T2-weighted axial sequence with selective fat saturation (SPIR/TSE, TE=70 ms, TR=1,600 ms), followed by coronal dynamic MRCP. The same thick-slab slice was sequentially acquired 12 times as breath-hold single-shot projection imaging (SSh, TE=900 ms, TE=8,000 ms) centred on the common bile duct (CBD). Two experienced radiologists independently and blindly evaluated MR images for the detection of CBD stones. Their inter-observer agreement kappa was determined. Secondly, the two observers read MR images in consensus again. CBD stones were demonstrated in 18 out of 57 patients (31.6 %) and confirmed by endoscopic retrograde cholangiography (ERCP, n=17) or intraoperative cholangiography (n=1). Clinical follow-up served as the "gold standard" in patients with negative results without following invasive procedure (n=28). Sensitivity, specificity, accuracy, positive and negative predictive value for MRCP resulting from consensus reading were 94.9%, 94.4%, 94.7%, 97.4% and 89.5%, respectively. Corresponding values of EUS were 97.4%, 94.4%, 96.5%, 97.4% and 94.4%. Inter-observer agreement kappa was 0.81. Repetitive thick-slab single-shot projection MRCP is an accurate non-invasive imaging modality for suspected choledocholithiasis and should be increasingly used to select those patients who require a subsequent therapeutic procedure, namely ERCP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bilioma is a rare complication of traumatic liver injury, and the precise site of bile leak is often difficult to demonstrate with a non-invasive technique. We report a case of post-traumatic bile leak in a 15-year-old girl in whom spiral CT after intravenous cholangiography allowed excellent preoperative demonstration of the extent of the liver rupture and an exact location of the bile leak. We think that spiral-CT cholangiography could be an accurate, non-invasive technique to investigate the biliary system in cases of paediatric liver trauma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fecal calprotectin is a small protein released mainly by neutrophils. It is recognized as a reliable, easy and non-invasive biomarker of gastro-intestinal inflammation. Normal values vary with age, with higher cut-off values during the first year of life (<350 microg/g) than in children (<275 microg/g) or adults (<50 microg/g). Fecal calprotectin can be a useful tool in initial evaluation of recurrent abdominal pain, helping to distinguish between functional gastro-intestinal disorders, where it is normal, and inflammatory bowel disease (IBD). It is not a specific marker of IBD but is increased in other situations of gastro-intestinal inflammation. In patients with IBD, fecal calprotectin is used to monitor treatment response.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article presents a feasibility study with the objective of investigating the potential of multi-detector computed tomography (MDCT) to estimate the bone age and sex of deceased persons. To obtain virtual skeletons, the bodies of 22 deceased persons with known age at death were scanned by MDCT using a special protocol that consisted of high-resolution imaging of the skull, shoulder girdle (including the upper half of the humeri), the symphysis pubis and the upper halves of the femora. Bone and soft-tissue reconstructions were performed in two and three dimensions. The resulting data were investigated by three anthropologists with different professional experience. Sex was determined by investigating three-dimensional models of the skull and pelvis. As a basic orientation for the age estimation, the complex method according to Nemeskéri and co-workers was applied. The final estimation was effected using additional parameters like the state of dentition, degeneration of the spine, etc., which where chosen individually by the three observers according to their experience. The results of the study show that the estimation of sex and age is possible by the use of MDCT. Virtual skeletons present an ideal collection for anthropological studies, because they are obtained in a non-invasive way and can be investigated ad infinitum.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: CMR has recently emerged as a robust and reliable technique to assess coronary artery disease (CAD). A negative perfusion CMR test predicts low event rates of 0.3-0.5%/year. Invasive coronary angiography (CA) remains the "gold standard" for the evaluation of CAD in many countries.Objective: Assessing the costs of the two strategies in the European CMR registry for the work-up of known or suspected CAD from a health care payer perspective. Strategy 1) a CA to all patients or 2) a CA only to patients who are diagnosed positive for ischemia in a prior CMR.Method and results: Using data of the European CMR registry (20 hospitals, 11'040 consecutive patients) we calculated the proportion of patients who were diagnosed positive (20.6%), uncertain (6.5%), and negative (72.9%) after the CMR test in patients with known or suspected CAD (n=2'717). No other medical test was performed to patients who were negative for ischemia. Positive diagnosed patients had a coronary angiography. Those with uncertain diagnosis had additional tests (84.7%: stress echocardiography, 13.1%: CCT, 2.3% SPECT), these costs were added to the CMR strategy costs. Information from costs for tests in Germany and Switzerland were used. A sensibility analysis was performed for inpatient CA. For costs see figure. Results - costs.Discussion: The CMR strategy costs less than the CA strategy for the health insurance systems both, in Germany and Switzerland. While lower in costs, the CMR strategy is a non-invasive one, does not expose to radiation, and yields additional information on cardiac function, viability, valves, and great vessels. Developing the use of CMR instead of CA might imply some reduction in costs together with superior patient safety and comfort, and a better utilization of resources at the hospital level. Document introduit le : 01.12.2011

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cardiovascular magnetic resonance (CMR) is a rapidly emerging non-invasive imaging technique free of X-Ray and offers higher spatial resolution than alternative forms of cardiac imaging for the assessment of left ventricular (LV) anatomy, function, and viability due to the unique capability of myocardial tissue characterization after gadolinium-chelates contrast administration. This imaging technique has clinical utility over a broad spectrum of heart diseases: ranging from ischaemic to non ischaemic aetiologies. Cardiomyopathies (CMP) are a heterogeneous group of diseases of the myocardium associated with architectural abnormalities and mechanical dysfunction. CMR can help excluding coronary artery disease and can provide positive diagnostic features for several CMP resulted in better diagnosis and management, Leading to improvements in mortality.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: NovoTTF-100A is a portable device delivering low-intensity, intermediate frequency electric fields via non-invasive, transducer arrays. Tumour Treatment Fields (TTF), a completely new therapeutic modality in cancer treatment, physically interfere with cell division. METHODS: Phase III trial of chemotherapy-free treatment of NovoTTF (20-24h/day) versus active chemotherapy in the treatment of patients with recurrent glioblastoma. Primary end-point was improvement of overall survival. RESULTS: Patients (median age 54years (range 23-80), Karnofsky performance status 80% (range 50-100) were randomised to TTF alone (n=120) or active chemotherapy control (n=117). Number of prior treatments was two (range 1-6). Median survival was 6.6 versus 6.0months (hazard ratio 0.86 [95% CI 0.66-1.12]; p=0.27), 1-year survival rate was 20% and 20%, progression-free survival rate at 6months was 21.4% and 15.1% (p=0.13), respectively in TTF and active control patients. Responses were more common in the TTF arm (14% versus 9.6%, p=0.19). The TTF-related adverse events were mild (14%) to moderate (2%) skin rash beneath the transducer arrays. Severe adverse events occurred in 6% and 16% (p=0.022) of patients treated with TTF and chemotherapy, respectively. Quality of life analyses favoured TTF therapy in most domains. CONCLUSIONS: This is the first controlled trial evaluating an entirely novel cancer treatment modality delivering electric fields rather than chemotherapy. No improvement in overall survival was demonstrated, however efficacy and activity with this chemotherapy-free treatment device appears comparable to chemotherapy regimens that are commonly used for recurrent glioblastoma. Toxicity and quality of life clearly favoured TTF.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The investigation of unexplained syncope remains a challenging clinical problem. In the present study we sought to evaluate the diagnostic value of a standardized work-up focusing on non invasive tests in patients with unexplained syncope referred to a syncope clinic, and whether certain combinations of clinical parameters are characteristic of rhythmic and reflex causes of syncope. METHODS AND RESULTS: 317 consecutive patients underwent a standardized work-up including a 12-lead ECG, physical examination, detailed history with screening for syncope-related symptoms using a structured questionnaire followed by carotid sinus massage (CSM), and head-up tilt test. Invasive testings including an electrophysiological study and implantation of a loop recorder were only performed in those with structural heart disease or traumatic syncope. Our work-up identified an etiology in 81% of the patients. Importantly, three quarters of the causes were established non invasively combining head-up tilt test, CSM and hyperventilation testing. Invasive tests yielded an additional 7% of diagnoses. Logistic analysis identified age and number of significant prodromes as the only predictive factors of rhythmic syncope. The same two factors, in addition to the duration of the ECG P-wave, were also predictive of vasovagal and psychogenic syncope. These factors, optimally combined in predictive models, showed a high negative and a modest positive predictive value. CONCLUSION: A standardized work-up focusing on non invasive tests allows to establish more than three quarters of syncope causes. Predictive models based on simple clinical parameters may help to distinguish between rhythmic and other causes of syncope