93 resultados para Modified algorithms


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inference of Markov random field images segmentation models is usually performed using iterative methods which adapt the well-known expectation-maximization (EM) algorithm for independent mixture models. However, some of these adaptations are ad hoc and may turn out numerically unstable. In this paper, we review three EM-like variants for Markov random field segmentation and compare their convergence properties both at the theoretical and practical levels. We specifically advocate a numerical scheme involving asynchronous voxel updating, for which general convergence results can be established. Our experiments on brain tissue classification in magnetic resonance images provide evidence that this algorithm may achieve significantly faster convergence than its competitors while yielding at least as good segmentation results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enterocystoplasty and gastrocystoplasty have been developed to restore adequate bladder capacity but they still result in the undesired harmful contact of urine with the intestinal mucosa. In an attempt to prevent this nonphysiological interface we performed several modified enterocystoplasties in the mini-pig model using a pedicled, detubularized, de-epithelialized sigmoid patch. Five techniques of patch coverage were used to evaluate urothelial growth or survival on the sigmoid patch. All but 1 patch had intestinal mucosa remnants with mucocele formation. When no coverage was applied or a biodegradable polyglactin mesh was temporarily covering the pedicled, detubularized, de-epithelialized sigmoid patch, severe shrinkage occurred. Partial cover with autologous urothelium islets seemed to decrease shrinkage. Adequate urothelium survival and satisfactory elastic properties of the patch were observed when total cover of the sigmoid patch was achieved with a sheet of homologous urothelium recovering autologous urothelial islets or when the patch was applied to protruding urothelium obtained following sagittal posterior detrusor myotomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents some contemporary approaches to spatial environmental data analysis. The main topics are concentrated on the decision-oriented problems of environmental spatial data mining and modeling: valorization and representativity of data with the help of exploratory data analysis, spatial predictions, probabilistic and risk mapping, development and application of conditional stochastic simulation models. The innovative part of the paper presents integrated/hybrid model-machine learning (ML) residuals sequential simulations-MLRSS. The models are based on multilayer perceptron and support vector regression ML algorithms used for modeling long-range spatial trends and sequential simulations of the residuals. NIL algorithms deliver non-linear solution for the spatial non-stationary problems, which are difficult for geostatistical approach. Geostatistical tools (variography) are used to characterize performance of ML algorithms, by analyzing quality and quantity of the spatially structured information extracted from data with ML algorithms. Sequential simulations provide efficient assessment of uncertainty and spatial variability. Case study from the Chernobyl fallouts illustrates the performance of the proposed model. It is shown that probability mapping, provided by the combination of ML data driven and geostatistical model based approaches, can be efficiently used in decision-making process. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the impact of noninvasive ventilation (NIV) algorithms available on intensive care unit ventilators on the incidence of patient-ventilator asynchrony in patients receiving NIV for acute respiratory failure. Prospective multicenter randomized cross-over study. Intensive care units in three university hospitals. Patients consecutively admitted to the ICU and treated by NIV with an ICU ventilator were included. Airway pressure, flow and surface diaphragmatic electromyography were recorded continuously during two 30-min periods, with the NIV (NIV+) or without the NIV algorithm (NIV0). Asynchrony events, the asynchrony index (AI) and a specific asynchrony index influenced by leaks (AIleaks) were determined from tracing analysis. Sixty-five patients were included. With and without the NIV algorithm, respectively, auto-triggering was present in 14 (22%) and 10 (15%) patients, ineffective breaths in 15 (23%) and 5 (8%) (p = 0.004), late cycling in 11 (17%) and 5 (8%) (p = 0.003), premature cycling in 22 (34%) and 21 (32%), and double triggering in 3 (5%) and 6 (9%). The mean number of asynchronies influenced by leaks was significantly reduced by the NIV algorithm (p < 0.05). A significant correlation was found between the magnitude of leaks and AIleaks when the NIV algorithm was not activated (p = 0.03). The global AI remained unchanged, mainly because on some ventilators with the NIV algorithm premature cycling occurs. In acute respiratory failure, NIV algorithms provided by ICU ventilators can reduce the incidence of asynchronies because of leaks, thus confirming bench test results, but some of these algorithms can generate premature cycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The central function of dendritic cells (DC) in inducing and preventing immune responses makes them ideal therapeutic targets for the induction of immunologic tolerance. In a rat in vivo model, we showed that dexamethasone-treated DC (Dex-DC) induced indirect pathway-mediated regulation and that CD4+CD25+ T cells were involved in the observed effects. The aim of the present study was to investigate the mechanisms underlying the acquired immunoregulatory properties of Dex-DC in the rat and human experimental systems. METHODS: After treatment with dexamethasone (Dex), the immunogenicity of Dex-DC was analyzed in T-cell proliferation and two-step hyporesponsiveness induction assays. After carboxyfluorescein diacetate succinimidyl ester labeling, CD4+CD25+ regulatory T-cell expansion was analyzed by flow cytometry, and cytokine secretion was measured by ELISA. RESULTS: In this study, we demonstrate in vitro that rat Dex-DC induced selective expansion of CD4+CD25+ regulatory T cells, which were responsible for alloantigen-specific hyporesponsiveness. The induction of regulatory T-cell division by rat Dex-DC was due to secretion of interleukin (IL)-2 by DC. Similarly, in human studies, monocyte-derived Dex-DC were also poorly immunogenic, were able to induce T-cell anergy in vitro, and expand a population of T cells with regulatory functions. This was accompanied by a change in the cytokine profile in DC and T cells in favor of IL-10. CONCLUSION: These data suggest that Dex-DC induced tolerance by different mechanisms in the two systems studied. Both rat and human Dex-DC were able to induce and expand regulatory T cells, which occurred in an IL-2 dependent manner in the rat system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé: Pratiquement tous les cancers du colon contiennent des mutations dans la voie de signalisation de Wnt qui active constitutivement cette voie. Cette activation mène à la stabilisation de la β-catenine. La β-catenin est transportée dans le noyau ou elle active des gènes cible en interagissant avec le facteur de transcription de TCF/LEF. Des adénovirus qui peuvent sélectivement se répliquer dans les cellules tumorales sont les agents qui peuvent permettre la déstruction de la tumeur mais pas le tissu normal. In vitro, les adénovirus avec des sites d'attachement du facteur de transcription TCF dans les promoteurs de l'adénovirus montrent une sélectivité et une activité dans une large sélection de lignées cellulaires de cancer du colon. Au contraire, in vivo, quand les adénovirus modifiés sont injectés dans la circulation, ils sont moins efficaces à cause de leur fixation par le foie et à cause de l'absence d'expression du récepteur du Coxsackie-Adénovirus (CAR). Le but de ma thèse était de modifier la protéine principale de capside de l'adénovirus, fibre, pour augmenter l'infection des tumeurs du cancer du colon. La fibre de l'adénovirus est responsable de l'attachement aux cellules et de l'entrée virale. J'ai inséré un peptide RGD dans la boucle HI de la fibre qui dirige sélectivement le virus aux récepteurs des integrines. Les integrines sont surexprimées par les cellules du cancer du colon et l'endothélium des vesseaux de la tumeur. Le virus re-ciblé, vKH6, a montré une activité accrue dans toutes les lignées cellulaires de cancer du colon, tandis que la sélectivité était maintenue. In vivo, vKH6 était supérieur au virus avec une capside de type sauvage en retardant la croissance de la tumeur. Le virus s'est répliqué plus vite et dispersé graduellement dans la tumeur. Cet effet a été montré par hybridation in situ et par PCR quantitative. Cependant, la monothérapie avec le virus n'a pu retarder la croissance des cellules tumorales SW620 greffées que de 2 semaines, mais à cause des régions non infectées la tumeur n'a pas pu être éliminée. Bien que la combinaison avec les chimiothérapies conventionnelles soit d'intérêt potentiel, presque toutes interfèrent avec la réplication virale. Les drogues antiangiogéniques sont des agents anti-tumoraux efficaces et prometteurs. Ces drogues n'interfèrent pas avec le cycle de vie de l'adénovirus. RAD001 est un dérivé de la rapamycine et il inhibe mTOR, une protéine kinase de la voie de PI3K. RAD001 empêche la croissance des cellules et il a aussi des effets anti-angiogénique et immunosuppressifs. RAD001 in vitro n'affecte pas l'expression des gènes viraux et la production virale. La combinaison de VKH6 et RAD001 in vivo a un effet additif en retardant la croissance de la tumeur. Des nouveaux peptides plus efficaces dans le ciblage de l'adénovirus sont nécessaires pour augmenter l'infection des tumeurs. J'ai créé un système de recombinaison qui permettra la sélection de nouveaux peptides dans le contexte du génome de l'adénovirus. Summary Virtually all colon cancers have mutations in the Wnt signalling pathway which result in the constitutive activation of the pathway. This activation leads to stabilization of β-catenin. β-catenin enters the nucleus and activates its target genes through interaction with the TCF transcription factor. Selectively replicating adenoviruses are promising novel agents that can destroy the tumour but not the surrounding normal tissue. In vitro, adenoviruses with TCF binding sites in the early viral promoters show selectivity and activity in a broad panel of viruses but in vivo they are less effective due to the lack of expression of the Coxsackie-Adenovirus receptor (CAR). The aim of my thesis was to modify the major capsid protein of the adenovirus, fibre, to increase the infection of colon tumours. Fibre of adenovirus is responsible for the binding to cells and for the viral uptake. I inserted an RGD binding peptide into the HI loop of fibre that selectively targets the virus to integrins that are overexpressed on tumour cells and on tumour endothelium. The retargeted virus, vKH6, showed increased activity in all colon cancer cell lines while selectivity was maintained. In vivo, vKH6 is superior to a matched virus with a wild type capsid in delaying tumour growth. vKH6 replicates and gradually spreads within the tumour as shown by in situ hybridization and Q-PCR. The virus alone can delay the growth of SW620 xenografts by 2 weeks but due to uninfected tumour regions the tumour cannot be cured. Although combination with conventional chemotherapeutics is of potential interest, almost all of them interfere with the viral replication. Growing evidence supports that anti-angiogenic drugs are effective and promising anti-tumour agents. These drugs interfere less with the viral life cycle. RAD001 is a rapamycin derivative and it blocks mTOR, a protein kinase in the PI3K pathway. RAD001 inhibits cell growth and has strong anti-angiogenic and immunosuppressive effects. RAD001 in vitro does not affect viral gene expression and viral burst size. In vivo vKH6 and RAD001 have an additive effect in delaying tumour growth, but tumour growth is still not completely inhibited. To further increase tumour infection new tumour specific targeting peptides are needed. I created an adenovirus display library that will allow the selection of targeting peptides. This system may also facilitate the production of fibre modified viruses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim of this study was to evaluate the stability over time of the individually defined interval of intravitreal ranibizumab injection (IVR) for the treatment of recurrent macular edema (ME) in central retinal vein occlusion (CRVO). Patients and Methods: A case series of treatment naïve patients followed in the Jules Gonin Eye Hospital for macular edema due to central retinal vein occlusion is presented. Patients were treated monthly with IVR until complete absence of fluid on qualitative SD-OCT with a minimum of 5 monthly IVR. Thereafter, they were followed according to a modified treat and extend regimen (mTER). Results: Twelve eyes (12 patients) with ME due to CRVO were included. The mean follow-up period was 31.3 months. Analysis showed that best corrected visual acuity (BCVA), central macular thickness and qualitative spectral domain optical coherence tomography (SD-OCT) showed comparable results under monthly interval, after titration of an individualized interval and when performed in a series. 78 % of treating intervals were within ± 2 weeks of the first individually adjusted interval. The mean first defined interval was 4.3 weeks and the mean interval over time was 5.5 weeks (p = 0.003). There was a trend towards longer interval over time. Conclusion: The adjusted interval of retreatment of patients with ME due to CRVO showed a high stability with a trend toward longer duration over time. An mTER regimen seems to be valuable to follow patients with ME with good stabilization of VA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Routinely collected health data, collected for administrative and clinical purposes, without specific a priori research questions, are increasingly used for observational, comparative effectiveness, health services research, and clinical trials. The rapid evolution and availability of routinely collected data for research has brought to light specific issues not addressed by existing reporting guidelines. The aim of the present project was to determine the priorities of stakeholders in order to guide the development of the REporting of studies Conducted using Observational Routinely-collected health Data (RECORD) statement. METHODS: Two modified electronic Delphi surveys were sent to stakeholders. The first determined themes deemed important to include in the RECORD statement, and was analyzed using qualitative methods. The second determined quantitative prioritization of the themes based on categorization of manuscript headings. The surveys were followed by a meeting of RECORD working committee, and re-engagement with stakeholders via an online commentary period. RESULTS: The qualitative survey (76 responses of 123 surveys sent) generated 10 overarching themes and 13 themes derived from existing STROBE categories. Highest-rated overall items for inclusion were: Disease/exposure identification algorithms; Characteristics of the population included in databases; and Characteristics of the data. In the quantitative survey (71 responses of 135 sent), the importance assigned to each of the compiled themes varied depending on the manuscript section to which they were assigned. Following the working committee meeting, online ranking by stakeholders provided feedback and resulted in revision of the final checklist. CONCLUSIONS: The RECORD statement incorporated the suggestions provided by a large, diverse group of stakeholders to create a reporting checklist specific to observational research using routinely collected health data. Our findings point to unique aspects of studies conducted with routinely collected health data and the perceived need for better reporting of methodological issues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: HIV surveillance requires monitoring of new HIV diagnoses and differentiation of incident and older infections. In 2008, Switzerland implemented a system for monitoring incident HIV infections based on the results of a line immunoassay (Inno-Lia) mandatorily conducted for HIV confirmation and type differentiation (HIV-1, HIV-2) of all newly diagnosed patients. Based on this system, we assessed the proportion of incident HIV infection among newly diagnosed cases in Switzerland during 2008-2013. METHODS AND RESULTS: Inno-Lia antibody reaction patterns recorded in anonymous HIV notifications to the federal health authority were classified by 10 published algorithms into incident (up to 12 months) or older infections. Utilizing these data, annual incident infection estimates were obtained in two ways, (i) based on the diagnostic performance of the algorithms and utilizing the relationship 'incident = true incident + false incident', (ii) based on the window-periods of the algorithms and utilizing the relationship 'Prevalence = Incidence x Duration'. From 2008-2013, 3'851 HIV notifications were received. Adult HIV-1 infections amounted to 3'809 cases, and 3'636 of them (95.5%) contained Inno-Lia data. Incident infection totals calculated were similar for the performance- and window-based methods, amounting on average to 1'755 (95% confidence interval, 1588-1923) and 1'790 cases (95% CI, 1679-1900), respectively. More than half of these were among men who had sex with men. Both methods showed a continuous decline of annual incident infections 2008-2013, totaling -59.5% and -50.2%, respectively. The decline of incident infections continued even in 2012, when a 15% increase in HIV notifications had been observed. This increase was entirely due to older infections. Overall declines 2008-2013 were of similar extent among the major transmission groups. CONCLUSIONS: Inno-Lia based incident HIV-1 infection surveillance proved useful and reliable. It represents a free, additional public health benefit of the use of this relatively costly test for HIV confirmation and type differentiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM: Our aim was to challenge the validity of these software algorithms. METHODS: We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS: In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION: We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes. Pediatr Pulmonol. 2015; 50:970-977. © 2015 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.