94 resultados para MEASURING DEVICES
Resumo:
The dynamic behavior of the decondensed chromatin can be monitored by real-time fluorescence confocal microscopy. It can be observed that different chromosomal sites enjoy different degrees of freedom during a certain period, exploring larger or smaller portions of nuclear volume. Here we measure the accessible surface for two chromosomal sites (yeast telomeres Tel3R and Tel6R) that both exhibit strong preferential association with the nuclear membrane in galactose-containing media, but differ significantly in gene activity. Telomere Tel6R, which harbors an inducible gene with high levels of transcription, explores a much larger surface than the telomere Tel3R, which is adjacent to inactive chromatin. Thus, our results distinguish two perinuclear movements characteristic of different transcriptional state, allowing for a better understanding of the correlation between activity of genes and chromatin dynamics.
Resumo:
INTRODUCTION: In alpine skiing, chronometry analysis is currently the most common tool to assess performance. It is widely used to rank competitors during races, as well as to manage athletes training and to evaluate material. Usually, this measurement is accurately realized using timing cells. Nevertheless, these devices are too complex and expensive to allow chronometry of every gates crossing. On the other side, differential GPS can be used for measuring gate crossing time (Waegli et al). However, this is complex (e.g. recording gate position with GPS) and mainly used in research applications. The aim of the study was to propose a wearable system to time gates crossing during alpine skiing slalom (SL), which is suitable for routine uses. METHODS: The proposed system was composed of a 3D accelerometer (ADXL320®, Analog Device, USA) placed at the sacrum of the athlete, a matrix of force sensors (Flexiforce®, Tekscan, USA) fixed on the right shin guard and a data logger (Physilog®, BioAGM, Switzerland). The sensors were sampled at 500 Hz. The crossing time were calculated in two phases. First, the accelerometer was used to detect the curves by considering the maximum of the mediolateral peak acceleration. Then, the force sensors were used to detect the impacts with the gates by considering maximum force variation. In case of non impact, the detection was realized based on the acceleration and features measured at the other gates. In order to assess the efficiency of the system, two different SL were monitored twice for two world cup level skiers, a male SL expert and a female downhill expert. RESULTS AND DISCUSSION: The combination of the accelerometer and force sensors allowed to clearly identify the gate crossing times. When comparing the runs of the SL expert and the downhill expert, we noticed that the SL expert was faster. For example for the first SL, the overall difference between the best run of each athlete was of 5.47s. At each gate, the SL expert increased the time difference slower at the beginning (0.27s/gate) than at the end (0.34s/gate). Furthermore, when comparing the runs of the SL expert, a maximum time difference of 20ms at each gate was noticed. This showed high repeatability skills of the SL expert. In opposite, the downhill expert with a maximum difference time of 1s at each gate was clearly less repeatable. Both skiers were not disturbed by the system. CONCLUSION: This study proposed a new wearable system to automatically time gates crossing during alpine skiing slalom combining force and accelerometer sensors. The system was evaluated with two professional world cup skiers and showed a high potential. This system could be extended to time other parameters. REFERENCES Waegli A, Skaloud J (2007). Inside GNSS, Spring, 24-34.
Resumo:
To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.
Resumo:
A simple tool to quantify discrepancies between knowledge, preoccupation and fear regarding hiv and aids is presented. This tool is based on standard questions available in health surveys. Some results using recent Swiss data are presented, and the method is discussed.
Resumo:
1. Species distribution models are increasingly used to address conservation questions, so their predictive capacity requires careful evaluation. Previous studies have shown how individual factors used in model construction can affect prediction. Although some factors probably have negligible effects compared to others, their relative effects are largely unknown. 2. We introduce a general "virtual ecologist" framework to study the relative importance of factors involved in the construction of species distribution models. 3. We illustrate the framework by examining the relative importance of five key factors-a missing covariate, spatial autocorrelation due to a dispersal process in presences/absences, sample size, sampling design and modeling technique-in a real study framework based on plants in a mountain landscape at regional scale, and show that, for the parameter values considered here, most of the variation in prediction accuracy is due to sample size and modeling technique. Contrary to repeatedly reported concerns, spatial autocorrelation has only comparatively small effects. 4. This study shows the importance of using a nested statistical framework to evaluate the relative effects of factors that may affect species distribution models.
Long-term continuous-flow left ventricular assist devices (LVAD) as bridge to heart transplantation.
Resumo:
Heart transplantation (HTx) is the treatment of choice for end-stage heart failure but the limited availability of heart's donors still represents a major issue. So long-term mechanical circulatory support (MCS) has been proposed as an alternative treatment option to assist patients scheduled on HTx waiting list bridging them for a variable time period to cardiac transplantation-the so-called bridge-to-transplantation (BTT) strategy. Nowadays approximately 90% of patients being considered for MCS receive a left ventricular assist device (LVAD). In fact, LVAD experienced several improvements in the last decade and the predominance of continuous-flow over pulsatile-flow technology has been evident since 2008. The aim of the present report is to give an overview of continuous-flow LVAD utilization in the specific setting of the BTT strategy taking into consideration the most representative articles of the scientific literature and focusing the attention on the evolution, clinical outcomes, relevant implications on the HTx strategy and future perspectives of the continuous-flow LVAD technology.
Resumo:
Introduction Occupational therapists could play an important role in facilitating driving cessation for ageing drivers. This, however, requires an easy-to-learn, standardised on-road evaluation method. This study therefore investigates whether use of P-drive' could be reliably taught to occupational therapists via a short half-day training session. Method Using the English 26-item version of P-drive, two occupational therapists evaluated the driving ability of 24 home-dwelling drivers aged 70 years or over on a standardised on-road route. Experienced driving instructors' on-road, subjective evaluations were then compared with P-drive scores. Results Following a short half-day training session, P-drive was shown to have almost perfect between-rater reliability (ICC2,1=0.950, 95% CI 0.889 to 0.978). Reliability was stable across sessions including the training phase even if occupational therapists seemed to become slightly less severe in their ratings with experience. P-drive's score was related to the driving instructors' subjective evaluations of driving skills in a non-linear manner (R-2=0.445, p=0.021). Conclusion P-drive is a reliable instrument that can easily be taught to occupational therapists and implemented as a way of standardising the on-road driving test.
Resumo:
In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.
Resumo:
Mobile technologies have brought about major changes in police equipment and police work. If a utopian narrative remains strongly linked to the adoption of new technologies, often formulated as 'magic bullets' to real occupational problems, there are important tensions between their 'imagined' outcomes and the (unexpected) effects that accompany their daily 'practical' use by police officers. This article offers an analysis of police officers' perceptions and interactions with security devices. In so doing, it develops a conceptual typology of strategies for coping with new technology inspired by Le Bourhis and Lascoumes: challenging, neutralizing and diverting. To that purpose, we adopt an ethnographic approach that focuses on the discourses, practices and actions of police officers in relation to three security devices: the mobile digital terminal, the mobile phone and the body camera. Based on a case study of a North American municipal police department, the article addresses how these technological devices are perceived and experienced by police officers on the beat.
Resumo:
The functional method is a new test theory using a new scoring method that assumes complexity in test structure, and thus takes into account every correlation between factors and items. The main specificity of the functional method is to model test scores by multiple regression instead of estimating them by using simplistic sums of points. In order to proceed, the functional method requires the creation of hyperspherical measurement space, in which item responses are expressed by their correlation with orthogonal factors. This method has three main qualities. First, measures are expressed in the absolute metric of correlations; therefore, items, scales and persons are expressed in the same measurement space using the same single metric. Second, factors are systematically orthogonal and without errors, which is optimal in order to predict other outcomes. Such predictions can be performed to estimate how one would answer to other tests, or even to model one's response strategy if it was perfectly coherent. Third, the functional method provides measures of individuals' response validity (i.e., control indices). Herein, we propose a standard procedure in order to identify whether test results are interpretable and to exclude invalid results caused by various response biases based on control indices.
Resumo:
Les importants progrès dans la qualité et la résolution des images obtenues par «absorptiométrie biphotonique à rayons X» ou DXA ont amélioré certaines modalités existantes et favorisé le développement de nouvelles fonctions permettant d'affiner de manière significative la prise en charge de nos patients dans diverses pathologies. On peut par exemple améliorer la prédiction du risque fracturaire par l'analyse indirecte de la micro et de la macroarchitecture osseuse, rechercher les marqueurs de pathologies associées (recherche de fractures vertébrales ou de fractures fémorales atypiques), ou évaluer le statut métabolique par la mesure de la composition corporelle. Avec les appareils DXA les plus performants, on pourra bientôt déterminer l'âge osseux, estimer le risque cardiovasculaire (par la mesure de la calcification de l'aorte abdominale), ou prédire la progression de l'arthrose articulaire et son évolution après la prise en charge chirurgicale dans la routine clinique. The significant progress on the quality and resolution of the images obtained by "Dual X-ray Absorptiometry" or DXA has permitted on one hand to improve some existing features and on the other to develop new ones, significantly refining the care of our patients in various pathologies. For example, by improving the prediction of fracture risk by indirect analysis of micro- and macro-architecture of the bone, by looking for markers of associated bone diseases (research vertebral fractures or atypical femoral fractures), or by assessing the metabolic status by the measurement of body composition. With the best performing DXA devices we will soon be able, in clinical routine, to determine bone age, to estimate cardiovascular risk (by measuring the calcification of the abdominal aorta) or to predict the progression of joint osteoarthritis and its evolution after surgical management.
Resumo:
The RFLP/PCR approach (restriction fragment length polymorphism/polymerase chain reaction) to genotypic mutation analysis described here measures mutations in restriction recognition sequences. Wild-type DNA is restricted before the resistant, mutated sequences are amplified by PCR and cloned. We tested the capacity of this experimental design to isolate a few copies of a mutated sequence of the human c-Ha-ras1 gene from a large excess of wild-type DNA. For this purpose we constructed a 272 bp fragment with 2 mutations in the PvuII recognition sequence 1727-1732 and studied the rescue by RFLP/PCR of a few copies of this 'PvuII mutant standard'. Following amplification with Taq-polymerase and cloning into lambda gt10, plaques containing wild-type sequence, PvuII mutant standard or Taq-polymerase induced bp changes were quantitated by hybridization with specific oligonucleotide probes. Our results indicate that 10 PvuII mutant standard copies can be rescued from 10(8) to 10(9) wild-type sequences. Taq polymerase errors originating from unrestricted, residual wild-type DNA were sequence dependent and consisted mostly of transversions originating at G.C bp. In contrast to a doubly mutated 'standard' the capacity to rescue single bp mutations by RFLP/PCR is limited by Taq-polymerase errors. Therefore, we assessed the capacity of our protocol to isolate a G to T transversion mutation at base pair 1698 of the MspI-site 1695-1698 of the c-Ha-ras1 gene from excess wild-type ras1 DNA. We found that 100 copies of the mutated ras1 fragment could be readily rescued from 10(8) copies of wild-type DNA.
Resumo:
This review presents the evolution of steroid analytical techniques, including gas chromatography coupled to mass spectrometry (GC-MS), immunoassay (IA) and targeted liquid chromatography coupled to mass spectrometry (LC-MS), and it evaluates the potential of extended steroid profiles by a metabolomics-based approach, namely steroidomics. Steroids regulate essential biological functions including growth and reproduction, and perturbations of the steroid homeostasis can generate serious physiological issues; therefore, specific and sensitive methods have been developed to measure steroid concentrations. GC-MS measuring several steroids simultaneously was considered the first historical standard method for analysis. Steroids were then quantified by immunoassay, allowing a higher throughput; however, major drawbacks included the measurement of a single compound instead of a panel and cross-reactivity reactions. Targeted LC-MS methods with selected reaction monitoring (SRM) were then introduced for quantifying a small steroid subset without the problems of cross-reactivity. The next step was the integration of metabolomic approaches in the context of steroid analyses. As metabolomics tends to identify and quantify all the metabolites (i.e., the metabolome) in a specific system, appropriate strategies were proposed for discovering new biomarkers. Steroidomics, defined as the untargeted analysis of the steroid content in a sample, was implemented in several fields, including doping analysis, clinical studies, in vivo or in vitro toxicology assays, and more. This review discusses the current analytical methods for assessing steroid changes and compares them to steroidomics. Steroids, their pathways, their implications in diseases and the biological matrices in which they are analysed will first be described. Then, the different analytical strategies will be presented with a focus on their ability to obtain relevant information on the steroid pattern. The future technical requirements for improving steroid analysis will also be presented.
Resumo:
Les pistolets à impulsion électrique (PIE) sont de plus en plus fréquemment utilisés en Europe ces dernières années, le modèle le plus connu étant le Taser®. Les connaissances scientifiques concernant les PIE et leurs effets potentiels restent toutefois limitées. Nous avons conduit une revue de littérature afin d'évaluer les implications potentielles de leur utilisation en termes de sécurité, de morbidité et de mortalité. Une exposition unique chez un individu sain peut généralement être considérée comme peu dangereuse. Les sujets à risque de complications sont les individus exposés à de multiples décharges, les personnes sous l'influence de substances psychoactives, ceux qui montrent des signes d'agitation extrême, ou encore les individus présentant des comorbidités médicales. L'éventail des complications pouvant survenir lors de leur exposition est large et inclut les lésions provoquées par les impacts des électrodes, les traumatismes liés à la chute induite par la paralysie transitoire ou des complications cardiovasculaires. Dans ce contexte, les personnes exposées doivent être examinées attentivement, et les éventuelles lésions traumatiques doivent être exclues. The use of electronic control devices (ECD), such as the Taser®, has increased in Europe over the past decade. However, scientific data concerning the potential health impact of ECD usage remains limited. We reviewed the scientific literature in order to evaluate the safety, mortality, and morbidity associated with ECD use. Exposure of a healthy individual to a single ECD electroshock can be considered generally safe. Complications can, however, occur if the patient is subject to multiple electroshocks, if the patient has significant medical comorbidities, or when exposure is associated with drug abuse or agitated delirium. The broad spectrum of potential complications associated with ECD exposure includes direct trauma caused by the ECD electrodes, injuries caused by the transient paralysis-induced fall, and cardiovascular events. An ECD-exposed patient requires careful examination during which traumatic injuries are actively sought out.