134 resultados para LASER ABLATION
Resumo:
Silver has been demonstrated to be a powerful cationization agent in mass spectrometry (MS) for various olefinic species such as cholesterol and fatty acids. This work explores the utility of metallic silver sputtering on tissue sections for high resolution imaging mass spectrometry (IMS) of olefins by laser desorption ionization (LDI). For this purpose, sputtered silver coating thickness was optimized on an assorted selection of mouse and rat tissues including brain, kidney, liver, and testis. For mouse brain tissue section, the thickness was adjusted to 23 ± 2 nm of silver to prevent ion suppression effects associated with a higher cholesterol and lipid content. On all other tissues, a thickness of at 16 ± 2 nm provided the best desorption/ionization efficiency. Characterization of the species by MS/MS showed a wide variety of olefinic compounds allowing the IMS of different lipid classes including cholesterol, arachidonic acid, docosahexaenoic acid, and triacylglyceride 52:3. A range of spatial resolutions for IMS were investigated from 150 μm down to the high resolution cellular range at 5 μm. The applicability of direct on-tissue silver sputtering to LDI-IMS of cholesterol and other olefinic compounds presents a novel approach to improve the amount of information that can be obtained from tissue sections. This IMS strategy is thus of interest for providing new biological insights on the role of cholesterol and other olefins in physiological pathways or disease.
Resumo:
Purpose Multiple organization indices (OIs) have been used to predict the outcome of stepwise catheter ablation (step-CA) in long-standing persistent AF (pers-AF), however with limited success. Our study aims at developing innovative OIs from baseline (BL, before ablation) ECG in order to predict the outcome of step-CA. Methods Fourteen consecutive patients (pts) (60±5 y, AF duration 21±9 m) underwent a step-CA consisting in pulmonary veins isolation, left atrial (LA) defragmentation and linear ablations, and right atrial (RA) ablations if non terminated. Chest lead V6 was placed in the back (V6b). After QRST cancellation from chest leads V1 to V6b, two OIs were computed to quantify the harmonic components of ECG atrial activity: 1) phase difference variance (PD) between the AF harmonic components as a measure of AF regularity, and 2) adaptive OI (AOI) evaluating the time evolution of the AF harmonic components. Both indices were compared to classical ones: a spectrum-based OI (SOI) and ECG AF cycle length (AFCL). Results Pers-AF was terminated into sinus rhythm or atrial tachycardia in 10/14 pts during step-CA, 8 during LA (LT), 2 during RA (RT) ablation, and 4 were non terminated (NT). The figure shows that LT was best separated from RT/NT before ablation by AOI computed on lead V1 (A) and PD from lead V6b (B) as compared to SOI and AFCL respectively. Conclusion Our results suggest that adaptive OIs computed before ablation perform better than classical OIs for separating LT from RT/NT pts. These findings are indicative of a higher baseline organization in LT pts that could be used to select candidates for the restoration of sinus rhythm by step-CA.
Resumo:
The graffiti on pottery discovered on the site of Aventicum (Avenches, VD/Switzerland) form the largest corpus of minor inscriptions of the Roman Empire studied until now. Indeed, a total of 1828 graffiti have been found. The reading and the recording of the inscriptions are generally dependent on the state of conservation of the graffito and its support. In numerous cases, only a pale shadow of the inscription is visible, which makes traditional observations, such as visual observations with the naked eye, unsuitable for its decipherment. Consequently, advanced techniques have been applied for enhancing the readability of such inscriptions. In our paper we show the efficiency of 3D laser profilometry as well as high resolution photography as powerful means to decipher illegible engraved inscriptions. The use of such analyses to decipher graffiti on pottery or on other materials enables a better understanding of minor inscriptions and improves the knowledge of the daily life of ancient populations substantially.
Resumo:
BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.
Resumo:
BACKGROUND AND OBJECTIVE: Theoretically myocardial angiogenesis of laser injury can be further enhanced by the addition of angiogenic growth factors. The influence of the way of administration of these factors on vascular growth around the channels is still unclear. MATERIALS AND METHODS: 18 pigs (mean weight 72 +/- 5.2 kg) were randomized to either triads of transmyocardial laser revascularization (TMLR) channels (group 1, n = 6) or isolated channels (group 2, n = 6), or a control group (n = 6). The animals had injections of bovine bone derived growth factor mixture either in the center of the triads in group 1 or within the channels themselves in group 2. Animals were sacrificed one month later for histological analysis. RESULTS: The vascular densities of myocardial areas within the triads of group 1 and around the channels in group 2 were significantly larger than in the control group: 15.2 +/- 3.7/mm2 and 14.2 +/- 3.5/mm2 respectively vs 5.3 +/- 1.6/mm2 (p < 0.001 for both differences). Differences of densities between group 1 and 2 were not statistically significant (p = 0.6). CONCLUSIONS: In this porcine model, the addition of a bovine bone derived growth factor mixture to TMLR significantly stimulates angiogenesis in the areas adjacent to the channels. The place of injection does not influence the angiogenesis intensity.
Resumo:
Objectifs: To describe the technique and results of radiofrequency ablation (RFA) of small renal tumors.Matériels et méthodes: 28 patients with median age 79 years were treated with RFA for small renal exophytic tumor (median size 20 mm). Most patients were poor operative candidatesbecause of associated morbidity. Four patients were treated for biopsy proven papillary tumor, 7 for clear cell carcinoma, 2 for oncocytoma and one for renalhepatocellular metastasis. No biopsy sample was obtained for the others because of a typical radiological aspect of RCC.Résultats: All patients but one were treated successfully in one session under combined ultrasound and CT guidance using either Radionics 2000 cool-tip or Bostonscientific expandable needles, one was treated in two sessions. One Splenic, 3 colic and 1 pancreatic displacement with CO2 injection and one injection of G5%solution in the costo-phrenic recessus were done in order to protect adjacent organs. Two complications were observed, one splenic iatrogenic lesion treated byembolization and one renal pelvis stenosis treated with JJ stent. After a mean follow-up of 20 months, no patient developped local recurrence on MRI follow-up.Conclusion: RFA is a simple and efficient technique pending on strict selected criteria (small size < 3 cm and exophytic lesion). Long local control is obtained with minimalmorbidity.
Resumo:
Background: To evaluate outcomes after optimized laser in situ keratomileusis (LASIK) for astigmatism correction with flap created by a mechanical microkeratome or a femtosecond laser. Patients and Methods: In this retrospective study, a total of 102 eyes of 71 consecutive patients were enrolled undergoing optimized LASIK treatments using the Allegretto laser system (WaveLight Laser Technologie AG, Erlangen, Germany). A mechanical microkeratome for flap creation was used (One Use, Moria®) in 46 eyes (31 patients, spherical equivalent [SE] -4.44 D ± 2.4) and a femtosecond laser was used (LDV, Ziemer®) in 56 eyes (40 patients, spherical equivalent [SE] -3.07 D ± 3.3). The two groups were matched for inclusion criteria and were operated under similar conditions by the same surgeon. Results: Overall, the preoperative spherical equivalent was -9.5 diopters (D) to +3.37 D; the preoperative manifest astigmatism was between -1.5 D and -3.5 D. At 6 months postoperatively, the mean postoperative uncorrected distance visual acuity (UDVA) was 0.93 ± 0.17 (range 0.4 to 1.2) in the Moria group and 1.0 ± 0.21 (range 0.6 to 1.6) in the Femto group, which was statistically significant (p = 0.003). Comparing the cylinder power there was a statistical difference between the two groups (p = 0.0015). Conclusions: This study shows that the method of flap creation has a significant impact on postoperative astigmatism with a significantly better postoperative UDVA in the Femto group. These findings suggest that the femtosecond laser provides a better platform for LASIK treatment of astigmatism than the commonly used microkeratome.
Resumo:
The glomus tumor is a rare, benign, but painful vascular neoplasm arising from the neuromyoarterial glomus. Primary intraosseous glomus tumor is even rarer, with only about 20 cases reported in the literature so far, 5 of which involved the spine. Surgical resection is currently considered the treatment of choice. We herewith present an uncommon case of primary intraosseous spinal glomus tumor involving the right pedicle of the eleventh thoracic vertebra (T11). To our knowledge, this is the first case of primary intraosseous spinal glomus tumor successfully treated by percutaneous CT-guided radiofrequency ablation (RFA).
Resumo:
OBJECTIVES: To examine whether percutaneous alcohol septal ablation affects coronary flow reserve (CFR) in patients with hypertrophic cardiomyopathy (HCM). METHODS: CFR was measured immediately before and after septal ablation in patients with symptomatic obstructive HCM. CFR was also obtained in normal subjects (NL) for comparison. RESULTS: Patients with HCM (n = 11), compared with NL (n = 22), had a lower mean (SD) baseline CFR (1.96 (0.5) vs 3.0 (0.7), p<0.001), a lower coronary resistance (1.04 (0.45) vs 3.0 (2.6), p = 0.002), a higher coronary diastolic/systolic velocity ratio (DSVR; 5.1 (3.0) vs 1.8 (0.5), p = 0.04) and a lower hyperaemic coronary flow per left ventricular (LV) mass (0.73 (0.4) vs 1.1 (0.6) ml/min/g, p = 0.007). Septal ablation in the HCM group (n = 7) reduced the outflow tract gradient but not the left atrial or LV diastolic pressures. Ablation resulted in immediate normalisation of CFR (to 3.1 (1), p = 0.01) and DSVR (to 1.9 (0.8), p = 0.09) and an increase in coronary resistance (to 1.91 (0.6), p = 0.02). This was probably related to an improvement in the systolic coronary flow. CONCLUSIONS: This study demonstrates that successful septal ablation in patients with symptomatic HCM results in immediate improvement in CFR, which is reduced in HCM partly because of the increased systolic contraction load.
Resumo:
Intracardiac organization indices such as atrial fibrillation (AF) cycle length (AFCL) have been used to track the efficiency of stepwise catheter ablation (step-CA) of longstanding persistent AF, however with limited success. The morphology of AF activation waves reflects the underlying activation patterns. Its temporal evolution is a local organization indicator that could be potentially used for tracking the efficiency of step-CA. We report a new method for characterizing the structure of the temporal evolution of activation wave morphology. Using recurrence plots, novel organization indices are proposed. By computing their relative evolution during the first step of ablation vs baseline, we found that these new parameters are superior to AFCL to track the effect of step-CA "en route" to AF termination.
Resumo:
The determination of line crossing sequences between rollerball pens and laser printers presents difficulties that may not be overcome using traditional techniques. This research aimed to study the potential of digital microscopy and 3-D laser profilometry to determine line crossing sequences between a toner and an aqueous ink line. Different paper types, rollerball pens, and writing pressure were tested. Correct opinions of the sequence were given for all case scenarios, using both techniques. When the toner was printed before the ink, a light reflection was observed in all crossing specimens, while this was never observed in the other sequence types. The 3-D laser profilometry, more time-consuming, presented the main advantage of providing quantitative results. The findings confirm the potential of the 3-D laser profilometry and demonstrate the efficiency of digital microscopy as a new technique for determining the sequence of line crossings involving rollerball pen ink and toner. With the mass marketing of laser printers and the popularity of rollerball pens, the determination of line crossing sequences between such instruments is encountered by forensic document examiners. This type of crossing presents difficulties with optical microscopic line crossing techniques involving ballpoint pens or gel pens and toner (1-4). Indeed, the rollerball's aqueous ink penetrates through the toner and is absorbed by the fibers of the paper, leaving the examiner with the impression that the toner is above the ink even when it is not (5). Novotny and Westwood (3) investigated the possibility of determining aqueous ink and toner crossing sequences by microscopic observation of the intersection before and after toner removal. A major disadvantage of their study resides in destruction of the sample by scraping off the toner line to see what was underneath. The aim of this research was to investigate the ways to overcome these difficulties through digital microscopy and three-dimensional (3-D) laser profilometry. The former was used as a technique for the determination of sequences between gel pen and toner printing strokes, but provided less conclusive results than that of an optical stereomicroscope (4). 3-D laser profilometry, which allows one to observe and measure the topography of a surface, has been the subject of a number of recent studies in this area. Berx and De Kinder (6) and Schirripa Spagnolo (7,8) have tested the application of laser profilometry to determine the sequence of intersections of several lines. The results obtained in these studies overcome disadvantages of other methods applied in this area, such as scanning electron microscope or the atomic force microscope. The main advantages of 3-D laser profilometry include the ease of implementation of the technique and its nondestructive nature, which does not require sample preparation (8-10). Moreover, the technique is reproducible and presents a high degree of freedom in the vertical axes (up to 1000 μm). However, when the paper surface presents a given roughness, if the pen impressions alter the paper with a depth similar to the roughness of medium, the results are not always conclusive (8). It becomes difficult in this case to distinguish which characteristics can be imputed to the pen impressions or the quality of the paper surface. This important limitation is assessed by testing different types of paper of variable quality (of different grammage and finishing) and the writing pressure. The authors will therefore assess the limits of 3-D laser profilometry technique and determine whether the method can overcome such constraints. Second, the authors will investigate the use of digital microscopy because it presents a number of advantages: it is efficient, user-friendly, and provides an objective evaluation and interpretation.
Resumo:
Pooled F(ab')2 fragments of three MAbs against distinct epitopes of carcinoembryonic antigen (CEA) were used for radioimmunotherapy of nude mice bearing a subcutaneous human colon carcinoma xenograft. 9-10 d after transplantation when tumor nodules were in exponential growth, 36 mice were treated by intravenous injection of different amounts of 131I-labeled MAb F(ab')2. All 14 mice injected with a single dose of 2,200 (n = 10) or 2,800 microCi (n = 4) showed complete tumor remission. 8 of the 10 mice treated with 2,200 microCi survived in good health for 1 yr when they were killed and shown to be tumor free. Four of nine other mice treated with four fractionated doses of 400 microCi showed no tumor relapse for more than 9 mo. In contrast, all 15 mice injected with 1,600-3,000 microCi 131I-control IgG F(ab')2 showed tumor growth retardation of only 1-4 wk, and 15 of 16 mice injected with unlabeled anti-CEA MAb F(ab')2 showed unmodified tumor progression as compared with untreated mice. From tissue radioactivity distributions it was calculated that by an injection of 2,200 microCi 131I-MAb F(ab')2 a mean dose of 8,335 rad was selectively delivered to the tumor, while the tissue-absorbed radiation doses for the normal organs were: peripheral blood, 2,093; stomach, 1,668; kidney, 1,289; lung, 1,185; liver, 617; spleen, 501; small intestine, 427; large intestine, 367; bone, 337; and muscle, 198. These treatments were well tolerated since out of 19 mice with complete tumor remission only 4 required bone marrow transplantation and 17 were in good health for 6-12 mo of observation. The results demonstrate the selective destruction of established human colon carcinoma transplants by intravenous injection of either single or fractionated doses of 131I-MAb F(ab')2.
Resumo:
BACKGROUND and OBJECTIVE: A non-touch laser-induced microdrilling procedure is studied on mouse zona pellucida (ZP). STUDY DESIGN/MATERIALS and METHODS: A 1.48-microns diode laser beam is focused in a 8-microns spot through a 45x objective of an inverted microscope. Mouse zygotes, suspended in a culture medium, are microdrilled by exposing their ZP to a short laser irradiation and allowed to develop in vitro. RESULTS: Various sharp-edged holes can be generated in the ZP with a single laser irradiation. Sizes can be varied by changing irradiation time (3-100 ms) or laser power (22-55 mW). Drilled zygotes present no signs of thermal damage under light and scanning electron microscopy and develop as expected in vitro, except for a distinct eight-shaped hatching behavior. CONCLUSION: The microdrilling procedure can generate standardized holes in mouse ZP, without any visible side effects. The hole formation can be explained by a local photothermolysis of the protein matrix.
Resumo:
OBJECTIVE: To study a new technic of laser treatment of macular holes. METHODS: 21 eyes with stage II-IV macular hole were treated with Argon-green laser. Pigment epithelium in the area of the hole was whitened with spots of 100-200 microns, 100-300 mW. We expected this treatment to create a cellular proliferation that could close and contract the hole. Follow-up after treatment ranged from 3 to 24 months (mean: 9.3 months). RESULTS: Within one month after treatment, the macular hole was closed in 7 eyes (33%) and partially closed in 5 eyes (24%). The visual acuity increased from 1 to 5 lignes (ETDRS chart) in 9 eyes (43%), it remained the same in 9 eyes (43%) and decreased from 1 to 2 lignes in 3 eyes (14%). CONCLUSION: Laser treatment of macular holes seems to be effective and could be proposed as an alternative to the patients who cannot be operated on by vitrectomy and gas tamponade.