249 resultados para Knee-joint angle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gliomas are routinely graded according to histopathological criteria established by the World Health Organization. Although this classification can be used to understand some of the variance in the clinical outcome of patients, there is still substantial heterogeneity within and between lesions of the same grade. This study evaluated image-guided tissue samples acquired from a large cohort of patients presenting with either new or recurrent gliomas of grades II-IV using ex vivo proton high-resolution magic angle spinning spectroscopy. The quantification of metabolite levels revealed several discrete profiles associated with primary glioma subtypes, as well as secondary subtypes that had undergone transformation to a higher grade at the time of recurrence. Statistical modeling further demonstrated that these metabolomic profiles could be differentially classified with respect to pathological grading and inter-grade conversions. Importantly, the myo-inositol to total choline index allowed for a separation of recurrent low-grade gliomas on different pathological trajectories, the heightened ratio of phosphocholine to glycerophosphocholine uniformly characterized several forms of glioblastoma multiforme, and the onco-metabolite D-2-hydroxyglutarate was shown to help distinguish secondary from primary grade IV glioma, as well as grade II and III from grade IV glioma. These data provide evidence that metabolite levels are of interest in the assessment of both intra-grade and intra-lesional malignancy. Such information could be used to enhance the diagnostic specificity of in vivo spectroscopy and to aid in the selection of the most appropriate therapy for individual patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives:¦The aim of this study was to estimate the prevalence of subclinical small joint synovitis detected by ultrasonography in patients with axial SpA, and to evaluate their relevance in terms of function or and disease activity.¦Methods:¦Forty axial SpA patients, 40 RA and 20 healthy subjects were evaluated by ultrasonography, using a reproducible semi-quantitative score by B-mode and Doppler, for synovitis, while disease activity and function were assessed using validated instruments (DAS28, BASDAI, BASFI, m-SACRAH and HAQ).¦Results:¦Median B-mode score were respectively 8.2 for axial SpA, 11.5 for RA and 6.0 for healthy subjects, corresponding to a prevalence of clinical significant synovitis of respectively 37.5%, 60% and 11% for a level of significance at > 8 chosen to¦classify as active > 75% of RA patient with DAS28 >2.6 and < 10% of controls. Addtionally, Doppler was positive in 8% of SpA, 30 % of RA and none of the healthy subjects. Echographic synovitis correlated with disease activity (DAS28) and function¦(HAQ, mSACRAH) in RA patients, but no correlation were found for SpA patients with disease activity (BASDAI) or function (BASFI, HAQ, mSACRAH). Cases of synovitis using classification by Doppler positivity were insufficient to allow any¦statistical analysis.¦Conclusions:¦B-mode ultrasonographic evaluation can demonstrate subclinical synovitis in almost 40% of SpA patients, but they do not appear to correlate with disease activity or function on the contrary to what is observed in RA patients, representing potentially different processes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sports clinician faces multiple treatment options when dealing with overload injuries, and it is important to evaluate their outcomes. Multiple scores exist, some clincian rated (CRO), others patient rated (PRO), the latter being currently favoured. This review presents some of these scores and we selected the ones we feel are the most appropriate for a sports clinician. We considered these common problems: tennis elbow, rotator cuff issues, groin pain, patellofemoral pain syndrome, achilles tendinopathy and ankle instability. In addition, an activity level score is useful to weigh the result in the context of return to performance. These scores help to create a common language between therapists and to evaluate treatments objectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnostic yield of prosthetic joint-associated infection is hampered by the phenotypic change of bacteria into a sessile and resistant form, also called biofilm. With sonication, adherent bacteria can be dislodged from the prosthesis. Species identification may be difficult because of their variations in phenotypic appearance and biochemical reaction. We have studied the phenotypic, genotypic, and biochemical properties of Escherichia coli variants isolated from a periprosthetic joint infection. The strains were collected from synovial fluid, periprosthetic tissue, and fluid from the explanted and sonicated prosthesis. Isolates from synovial fluid revealed a normal phenotype, whereas a few variants from periprosthetic tissue and all isolates from sonication fluid showed different morphological features (including small-colony variants). All isolates from sonication fluid were beta-galactosidase negative and nonmotile; most were indole negative. Because of further variations in biochemical properties, species identification was false or not possible in 50% of the isolates included in this study. In contrast to normal phenotypes, variants were resistant to aminoglycosides. Typing of the isolates using pulsed-field gel electrophoresis yielded nonidentical banding patterns, but all strains were assigned to the same clonal origin when compared with 207 unrelated E. coli isolates. The bacteria were repeatedly passaged on culture media and reanalyzed. Thereafter, most variants reverted to normal phenotype and regained their motility and certain biochemical properties. In addition, some variants displayed aminoglycoside susceptibility after reversion. Sonication of an explanted prosthesis allows insight into the lifestyle of bacteria in biofilms. Since sonication fluid also reveals dislodged sessile forms, species identification of such variants may be misleading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infections after total joint arthroplasty are rare but come with severe consequences. Timely, adequate and standardized treatment beginning at the onset of symptoms will have a major impact on the handling of this dreaded complication. In absences of clear guidelines, errors are often committed, with occasionally severe consequences for the patient. In this article, the 10 most frequent errors starting with diagnostics till antibiotic and surgical treatment will be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thanks to decades of research, gait analysis has become an efficient tool. However, mainly due to the price of the motion capture systems, standard gait laboratories have the capability to measure only a few consecutive steps of ground walking. Recently, wearable systems were proposed to measure human motion without volume limitation. Although accurate, these systems are incompatible with most of existing calibration procedures and several years of research will be necessary for their validation. A new approach consisting of using a stationary system with a small capture volume for the calibration procedure and then to measure gait using a wearable system could be very advantageous. It could benefit from the knowledge related to stationary systems, allow long distance monitoring and provide new descriptive parameters. The aim of this study was to demonstrate the potential of this approach. Thus, a combined system was proposed to measure the 3D lower body joints angles and segmental angular velocities. It was then assessed in terms of reliability towards the calibration procedure, repeatability and concurrent validity. The dispersion of the joint angles across calibrations was comparable to those of stationary systems and good reliability was obtained for the angular velocities. The repeatability results confirmed that mean cycle kinematics of long distance walks could be used for subjects' comparison and pointed out an interest for the variability between cycles. Finally, kinematics differences were observed between participants with different ankle conditions. In conclusion, this study demonstrated the potential of a mixed approach for human movement analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The ideal local anesthetic regime for femoral nerve block that balances analgesia with mobility after total knee arthroplasty (TKA) remains undefined. QUESTIONS/PURPOSES: We compared two volumes and concentrations of a fixed dose of ropivacaine for continuous femoral nerve block after TKA to a single injection femoral nerve block with ropivacaine to determine (1) time to discharge readiness; (2) early pain scores and analgesic consumption; and (3) functional outcomes, including range of motion and WOMAC scores at the time of recovery. METHODS: Ninety-nine patients were allocated to one of three continuous femoral nerve block groups for this randomized, placebo-controlled, double-blind trial: a high concentration group (ropivacaine 0.2% infusion), a low concentration group (ropivacaine 0.1% infusion), or a placebo infusion group (saline 0.9% infusion). Infusions were discontinued on postoperative Day (POD) 2. The primary outcome was time to discharge readiness. Secondary outcomes included opioid consumption, pain, and functional outcomes. Ninety-three patients completed the study protocol; the study was halted early because of unanticipated changes to pain protocols at the host institution, by which time only 61% of the required number of patients had been enrolled. RESULTS: With the numbers available, the mean time to discharge readiness was not different between groups (high concentration group, 62 hours [95% confidence interval [CI], 51-72 hours]; low concentration group, 73 hours [95% CI, 63-83 hours]; placebo infusion group 65 hours [95% CI, 56-75 hours]; p = 0.27). Patients in the low concentration group consumed significantly less morphine during the period of infusion (POD 1, high concentration group, 56 mg [95% CI, 42-70 mg]; low concentration group, 35 mg [95% CI, 27-43 mg]; placebo infusion group, 48 mg [95% CI, 38-59 mg], p = 0.02; POD 2, high concentration group, 50 mg [95% CI, 41-60 mg]; low concentration group, 33 mg [95% CI, 24-42 mg]; placebo infusion group, 39 mg [95% CI, 30-48 mg], p = 0.04); however, there were no important differences in pain scores or opioid-related side effects with the numbers available. Likewise, there were no important differences in functional outcomes between groups. CONCLUSIONS: Based on this study, which was terminated prematurely before the desired sample size could be achieved, we were unable to demonstrate that varying the concentration and volume of a fixed-dose ropivacaine infusion for continuous femoral nerve block influences time to discharge readiness when compared with a conventional single-injection femoral nerve block after TKA. A low concentration of ropivacaine infusion can reduce postoperative opioid consumption but without any important differences in pain scores, side effects, or functional outcomes. These pilot data may be used to inform the statistical power of future randomized trials. LEVEL OF EVIDENCE: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.