111 resultados para Electrical bias
Resumo:
Background : The issue of gender is acknowledged as a key issue for the AIDS epidemic. World AIDS Conferences (WAC) have constituted a major discursive space for the epidemic. We sought to establish the balance regarding gender in the AIDS scientific discourse by following its development in the published proceedings of WAC. Fifteen successive WAC 1989-2012 served to establish a "barometer" of scientific interest in heterosexual and homo/bisexual men and women throughout the epidemic. It was hypothesised that, as in other domains of Sexual and Reproductive Health, heterosexual men would be "forgotten" partners. Method : Abstracts from each conference were entered in electronic form into an Access database. Queries were created to generate five categories of interest and to monitor their annual frequency. All abstract titles including the term "men" or "women" were identified. Collections of synonyms were systematically and iteratively developed in order to classify further abstracts according to whether they included terms referring to "homo/bisexual" or "heterosexual". Reference to "Mother to Child Transmission" (MTCT) was also flagged. Results : The category including "men", but without additional reference to "homo-bisexuel" (i.e. referring to men in general and/or to heterosexual men) consistently appears four times less often than the equivalent category for women. Excluding abstracts on women and MTCT has little impact on this difference. Abstracts including reference to both "men" and "homo-bisexual" emerge as the secondmost frequent category; presence of the equivalent category for women is minimal. Conclusion : The hypothesised absence of heterosexual men in the AIDS discourse was confirmed. Although the relative presence of homo-bisexual men and women as a focal subject may be explained by epidemiological data, this is not so in the case of heterosexual men and women. This imbalance has consequences for HIV prevention.
Resumo:
Nous présontons l'étalonnage d'un test mnésique de recognition dans un échantillon de 180 adultes francophones de la Suisse Romande. Le test comprend trois formes utilisant un matériel verbal (mots) ou non verbal (visages ou paysages). Une attention particulière est accordée à l'âge dans la présentation des résultats. Celui-ci affecte plus précocement et plus intensément la performance aux formes non verbales qu'à la forme verbale du test. Il induit également une importante augmentation du nombre de fausses reconnaissances pour les formes non verbales.
Resumo:
Indirect reciprocity is a form of reciprocity where help is given to individuals based on their reputation. In indirect reciprocity, bad acts (such as not helping) reduce an individual's reputation while good acts (such as helping) increase an individual's reputation. Studies of indirect reciprocity assume that good acts and bad acts are weighted equally when assessing the reputation of an individual. As different information can be processed in different ways, this is not likely to be the case, and it is possible that an individual could bias an actor's reputation by putting more weight to acts of defection (not helping) than acts of co-operation (helping) or vice versa. We term this difference 'judgement bias', and build an individual-based model of image scoring to investigate the conditions under which it may evolve. We find that, if the benefits of co-operation are small, judgement bias is weighted towards acts perceived to be bad; if the benefits are high, the reverse is true. Our result is consistent under both scoring and standing strategies, and we find that allowing judgement bias to evolve increases the level of co-operation in the population.
Resumo:
We have constructed a forward modelling code in Matlab, capable of handling several commonly used electrical and electromagnetic methods in a 1D environment. We review the implemented electromagnetic field equations for grounded wires, frequency and transient soundings and present new solutions in the case of a non-magnetic first layer. The CR1Dmod code evaluates the Hankel transforms occurring in the field equations using either the Fast Hankel Transform based on digital filter theory, or a numerical integration scheme applied between the zeros of the Bessel function. A graphical user interface allows easy construction of 1D models and control of the parameters. Modelling results are in agreement with other authors, but the time of computation is less efficient than other available codes. Nevertheless, the CR1Dmod routine handles complex resistivities and offers solutions based on the full EM-equations as well as the quasi-static approximation. Thus, modelling of effects based on changes in the magnetic permeability and the permittivity is also possible.
Resumo:
In this paper the problem of intensity inhomogeneity athigh magnetic field on magnetic resonance images isaddressed. Specifically, rat brain images at 9.4Tacquired with a surface coil are bias corrected. Wepropose a low- pass frequency model that takes intoaccount not only background-object contours but alsoother important contours inside the image. Twopre-processing filters are proposed: first, to create avolume of interest without contours, and second, toextrapolate the image values of such masked area to thewhole image. Results are assessed quantitatively andvisually in comparison to standard low pass filterapproach, and they show as expected better accuracy inenhancing image intensity.
Resumo:
BACKGROUND: Health professionals and policymakers aspire to make healthcare decisions based on the entire relevant research evidence. This, however, can rarely be achieved because a considerable amount of research findings are not published, especially in case of 'negative' results - a phenomenon widely recognized as publication bias. Different methods of detecting, quantifying and adjusting for publication bias in meta-analyses have been described in the literature, such as graphical approaches and formal statistical tests to detect publication bias, and statistical approaches to modify effect sizes to adjust a pooled estimate when the presence of publication bias is suspected. An up-to-date systematic review of the existing methods is lacking. METHODS/DESIGN: The objectives of this systematic review are as follows:âeuro¢ To systematically review methodological articles which focus on non-publication of studies and to describe methods of detecting and/or quantifying and/or adjusting for publication bias in meta-analyses.âeuro¢ To appraise strengths and weaknesses of methods, the resources they require, and the conditions under which the method could be used, based on findings of included studies.We will systematically search Web of Science, Medline, and the Cochrane Library for methodological articles that describe at least one method of detecting and/or quantifying and/or adjusting for publication bias in meta-analyses. A dedicated data extraction form is developed and pilot-tested. Working in teams of two, we will independently extract relevant information from each eligible article. As this will be a qualitative systematic review, data reporting will involve a descriptive summary. DISCUSSION: Results are expected to be publicly available in mid 2013. This systematic review together with the results of other systematic reviews of the OPEN project (To Overcome Failure to Publish Negative Findings) will serve as a basis for the development of future policies and guidelines regarding the assessment and handling of publication bias in meta-analyses.
Resumo:
The effect of motor training using closed loop controlled Functional Electrical Stimulation (FES) on motor performance was studied in 5 spinal cord injured (SCI) volunteers. The subjects trained 2 to 3 times a week during 2 months on a newly developed rehabilitation robot (MotionMaker?). The FES induced muscle force could be adequately adjusted throughout the programmed exercises by the way of a closed loop control of the stimulation currents. The software of the MotionMaker? allowed spasms to be detected accurately and managed in a way to prevent any harm to the SCI persons. Subjects with incomplete SCI reported an increased proprioceptive awareness for motion and were able to achieve a better voluntary activation of their leg muscles during controlled FES. At the end of the training, the voluntary force of the 4 incomplete SCI patients was found increased by 388% on their most affected leg and by 193% on the other leg. Active mobilisation with controlled FES seems to be effective in improving motor function in SCI persons by increasing the sensory input to neuronal circuits involved in motor control as well as by increasing muscle strength.
Resumo:
OBJECTIVE: To determine the incidence and risk factors of electrical seizures and other electrical epileptic activity using continuous EEG (cEEG) in patients with acute stroke. METHODS: One hundred consecutive patients with acute stroke admitted to our stroke unit underwent cEEG using 10 electrodes. In addition to electrical seizures, repetitive focal sharp waves (RSHWs), repetitive focal spikes (RSPs), and periodic lateralized epileptic discharges (PLEDs) were recorded. RESULTS: In the 100 patients, cEEG was recorded for a mean duration of 17 hours 34 minutes (range 1 hour 12 minutes to 37 hours 10 minutes). Epileptic activity occurred in 17 patients and consisted of RSHWs in seven, RSPs in seven, and PLEDs in three. Electrical seizures occurred in two patients. On univariate Cox regression analysis, predictors for electrical epileptic activity were stroke severity (high score on the National Institutes of Health Stroke Scale) (hazard ratio [HR] 1.12; p = 0.002), cortical involvement (HR 5.71; p = 0.021), and thrombolysis (HR 3.27; p = 0.040). Age, sex, stroke type, use of EEG-modifying medication, and cardiovascular risk factors were not predictors of electrical epileptic activity. On multivariate analysis, stroke severity was the only independent predictor (HR 1.09; p = 0.016). CONCLUSION: In patients with acute stroke, electrical epileptic activity occurs more frequently than previously suspected.
Resumo:
BACKGROUND: Selective publication of studies, which is commonly called publication bias, is widely recognized. Over the years a new nomenclature for other types of bias related to non-publication or distortion related to the dissemination of research findings has been developed. However, several of these different biases are often still summarized by the term 'publication bias'. METHODS/DESIGN: As part of the OPEN Project (To Overcome failure to Publish nEgative fiNdings) we will conduct a systematic review with the following objectives:- To systematically review highly cited articles that focus on non-publication of studies and to present the various definitions of biases related to the dissemination of research findings contained in the articles identified.- To develop and discuss a new framework on nomenclature of various aspects of distortion in the dissemination process that leads to public availability of research findings in an international group of experts in the context of the OPEN Project.We will systematically search Web of Knowledge for highly cited articles that provide a definition of biases related to the dissemination of research findings. A specifically designed data extraction form will be developed and pilot-tested. Working in teams of two, we will independently extract relevant information from each eligible article.For the development of a new framework we will construct an initial table listing different levels and different hazards en route to making research findings public. An international group of experts will iteratively review the table and reflect on its content until no new insights emerge and consensus has been reached. DISCUSSION: Results are expected to be publicly available in mid-2013. This systematic review together with the results of other systematic reviews of the OPEN project will serve as a basis for the development of future policies and guidelines regarding the assessment and prevention of publication bias.
Resumo:
OBJECTIVE: The aim of this study was to examine the differences between those who gave informed consent to a study on substance use and those who did not, and to analyze whether differences changed with varying nonconsent rates. METHOD: Cross-sectional questionnaire data on demographics, alcohol, smoking, and cannabis use were obtained for 6,099 French- and 5,720 German-speaking 20-year-old Swiss men. Enrollment took place over 11 months for the Cohort Study on Substance Use Risk Factors (C-SURF). Consenters and nonconsenters were asked to complete a short questionnaire. Data for nearly the entire population were available because 94% responded. Weekly differences in consent rates were analyzed. Regressions examined the associations of substance use with consent giving and consent rates and the interaction between the two. RESULTS: Nonconsenters had higher substance use patterns, although they were more often alcohol abstainers; differences were small and not always significant and did not decrease as consent rates increased. CONCLUSIONS: Substance use currently is a minor sensitive topic among young men, resulting in small differences between nonconsenters and consenters. As consent rates increase, additional individuals are similar to those observed at lower consent rates. Estimates of analytical studies looking at associations of substance use with other variables will not differ at reasonable consent rates of 50%-80%. Descriptive prevalence studies may be biased, but only at very low rates of consent.
Resumo:
Electrical Impedance Tomography (EIT) is an imaging method which enables a volume conductivity map of a subject to be produced from multiple impedance measurements. It has the potential to become a portable non-invasive imaging technique of particular use in imaging brain function. Accurate numerical forward models may be used to improve image reconstruction but, until now, have employed an assumption of isotropic tissue conductivity. This may be expected to introduce inaccuracy, as body tissues, especially those such as white matter and the skull in head imaging, are highly anisotropic. The purpose of this study was, for the first time, to develop a method for incorporating anisotropy in a forward numerical model for EIT of the head and assess the resulting improvement in image quality in the case of linear reconstruction of one example of the human head. A realistic Finite Element Model (FEM) of an adult human head with segments for the scalp, skull, CSF, and brain was produced from a structural MRI. Anisotropy of the brain was estimated from a diffusion tensor-MRI of the same subject and anisotropy of the skull was approximated from the structural information. A method for incorporation of anisotropy in the forward model and its use in image reconstruction was produced. The improvement in reconstructed image quality was assessed in computer simulation by producing forward data, and then linear reconstruction using a sensitivity matrix approach. The mean boundary data difference between anisotropic and isotropic forward models for a reference conductivity was 50%. Use of the correct anisotropic FEM in image reconstruction, as opposed to an isotropic one, corrected an error of 24 mm in imaging a 10% conductivity decrease located in the hippocampus, improved localisation for conductivity changes deep in the brain and due to epilepsy by 4-17 mm, and, overall, led to a substantial improvement on image quality. This suggests that incorporation of anisotropy in numerical models used for image reconstruction is likely to improve EIT image quality.
Resumo:
PURPOSE: Patients with magnetic resonance (MR)-negative focal epilepsy (MRN-E) have less favorable surgical outcomes (between 40% and 70%) compared to those in whom an MRI lesion guides the site of surgical intervention (60-90%). Patients with extratemporal MRN-E have the worst outcome (around 50% chance of seizure freedom). We studied whether electroencephalography (EEG) source imaging (ESI) of interictal epileptic activity can contribute to the identification of the epileptic focus in patients with normal MRI. METHODS: We carried out ESI in 10 operated patients with nonlesional MRI and a postsurgical follow-up of at least 1 year. Five of the 10 patients had extratemporal lobe epilepsy. Evaluation comprised surface and intracranial EEG monitoring of ictal and interictal events, structural MRI, [(18)F]fluorodeoxyglucose positron emission tomography (FDG-PET), ictal and interictal perfusion single photon emission computed tomography (SPECT) scans. Eight of the 10 patients also underwent intracranial monitoring. RESULTS: ESI correctly localized the epileptic focus within the resection margins in 8 of 10 patients, 9 of whom experienced favorable postsurgical outcomes. DISCUSSION: The results highlight the diagnostic value of ESI and encourage broadening its application to patients with MRN-E. If the surface EEG contains fairly localized spikes, ESI contributes to the presurgical decision process.
Resumo:
INTRODUCTION: In this study we investigated differences in the spatial recruitment of motor units (MUs) in the quadriceps when electrical stimulation is applied over the quadriceps belly versus the femoral nerve. METHODS: M-waves and mechanical twitches were evoked using over-the-quadriceps and femoral nerve stimulation of gradually increasing intensity from 22 young, healthy subjects. Spatial recruitment was investigated using recruitment curves of M-waves recorded from the vastus medialis (VM) and vastus lateralis (VL) and of twitches recorded from the quadriceps. RESULTS: At maximal stimulation intensity (Imax), no differences were found between nerve and over-the-quadriceps stimulation. At submaximal intensities, VL M-wave amplitude was higher for over-the-quadriceps stimulation at 40% Imax, and peak twitch force was greater for nerve stimulation at 60% and 80% Imax. CONCLUSIONS: For the VM, MU spatial recruitment during nerve and over-the-quadriceps stimulation of increasing intensity occurred in a similar manner, whereas significant differences were observed for the VL. Muscle Nerve, 2013.
Resumo:
MOTIVATION: Comparative analyses of gene expression data from different species have become an important component of the study of molecular evolution. Thus methods are needed to estimate evolutionary distances between expression profiles, as well as a neutral reference to estimate selective pressure. Divergence between expression profiles of homologous genes is often calculated with Pearson's or Euclidean distance. Neutral divergence is usually inferred from randomized data. Despite being widely used, neither of these two steps has been well studied. Here, we analyze these methods formally and on real data, highlight their limitations and propose improvements. RESULTS: It has been demonstrated that Pearson's distance, in contrast to Euclidean distance, leads to underestimation of the expression similarity between homologous genes with a conserved uniform pattern of expression. Here, we first extend this study to genes with conserved, but specific pattern of expression. Surprisingly, we find that both Pearson's and Euclidean distances used as a measure of expression similarity between genes depend on the expression specificity of those genes. We also show that the Euclidean distance depends strongly on data normalization. Next, we show that the randomization procedure that is widely used to estimate the rate of neutral evolution is biased when broadly expressed genes are abundant in the data. To overcome this problem, we propose a novel randomization procedure that is unbiased with respect to expression profiles present in the datasets. Applying our method to the mouse and human gene expression data suggests significant gene expression conservation between these species. CONTACT: marc.robinson-rechavi@unil.ch; sven.bergmann@unil.ch SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.