283 resultados para Efficiency comparison of gill nets


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Previous literature has suggested that laws and regulations may impact the use of palliative sedation. Our present study compares the attitudes of French-speaking physicians practicing in the Quebec and Swiss environments, where different laws are in place regarding physician-assisted suicide. METHOD: Data were drawn from two prior studies, one by Blondeau and colleagues and another by Beauverd and coworkers, employing the same two-by-two experimental design with length of prognosis and type of suffering as independent variables. Both the effect of these variables and the effect of their interaction on Swiss and Quebec physicians' attitudes toward sedation were compared. The written comments of respondents were submitted to a qualitative content analysis and summarized in a comparative perspective. RESULTS: The analysis of variance showed that only the type of suffering had an effect on physicians' attitudes toward sedation. The results of the Wilcoxon test indicated that the attitudes of physicians from Quebec and Switzerland tended to be different for two vignettes: long-term prognosis with existential suffering (p = 0.0577) and short-term prognosis with physical suffering (p = 0.0914). In both cases, the Swiss physicians were less prone to palliative sedation. SIGNIFICANCE OF RESULTS: The attitudes of physicians from Quebec and Switzerland toward palliative sedation, particularly regarding prognosis and type of suffering, seem similar. However, the results suggest that physicians from Quebec could be slightly more open to palliative sedation, even though most were not in favor of this practice as an answer to end-of-life existential suffering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Despite the increasing incidences of the publication of assessment frameworks intending to establish the "standards" of the quality of qualitative research, the research conducted using such empirical methods are still facing difficulties in being published or recognised by funding agencies. Methods: We conducted a thematic content analysis of eight frameworks from psychology/psychiatry and general medicine. The frameworks and their criteria are then compared against each other. Findings: The results illustrated the difficulties in reaching consensus on the definition of quality criteria. This showed the differences between the frameworks from the point of views of the underlying epistemology and the criteria suggested. Discussion: The aforementioned differences reflect the diversity of paradigms implicitly referred to by the authors of the frameworks, although rarely explicitly mentioned in text. We conclude that the increase in qualitative research and publications has failed to overcome the difficulties in establishing shared criteria and the great heterogeneity of concepts raises methodological and epistemological problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To better define the concordance of visual loss in patients with nonarteritic anterior ischemic optic neuropathy (NAION). METHODS The medical records of 86 patients with bilateral sequential NAION were reviewed retrospectively, and visual function was assessed using visual acuity, Goldmann visual fields, color vision, and relative afferent papillary defect. A quantitative total visual field score and score per quadrant were analyzed for each eye using the numerical Goldmann visual field scoring method. RESULTS Outcome measures were visual acuity, visual field, color vision, and relative afferent papillary defect. A statistically significant correlation was found between fellow eyes for multiple parameters, including logMAR visual acuity (P = .01), global visual field (P < .001), superior visual field (P < .001), and inferior visual field (P < .001). The mean deviation of total (P < .001) and pattern (P < .001) deviation analyses was significantly less between fellow eyes than between first and second eyes of different patients. CONCLUSIONS Visual function between fellow eyes showed a fair to moderate correlation that was statistically significant. The pattern of vision loss was also more similar in fellow eyes than between eyes of different patients. These results may help allow better prediction of visual outcome for the second eye in patients with NAION.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results ( n=29) and patient's clinical evolution ( n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer ( p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Percutaneous closure of patent foramen ovale (PFO) has been proposed as the treatment of choice for young high-risk patients who suffered cryptogenic stroke and/or peripheral paradoxical embolism. We sought to compare prospectively two different devices used for percutaneous PFO closure.Prospective data were collected on 40 high risk patients (females: 38%, mean age : 44 +/- 11 years, interatrial septal aneurysm >10 mm: 68%) who underwent percutaneous PFO closure after cryptogenic stroke (n = 38) or peripheral paradoxical embolism (n = 2). Chronologically, 20 patients were first treated by a PFO-Star (Cardia, Burnsville, MI) device. Then, 20 other patients received a Starflex occluder (NMT, Boston, MA). The primary endpoint was complete PFO closure at 6 months as assessed by transthoracic contrast echocardiography. Secondary endpoints were major peri- or post procedural complications and clinical recurrence at 1 year follow-up.Baseline clinical and anatomical characteristics were comparable for both groups. Complete PFO closure was observed in 50% (PFO-Star) and 90% (Starflex) of patients (p=0.001) respectively. Major peri-procedural complications occurred in the PFO-star group only: right-sided device thrombus (1 patient) and aorto-right atrial fistula (1 patient). At 1 year follow-up, no clinical recurrence occurred.In conclusion, despite the absence of clinical recurrence in this high-risk population with presumed paradoxical embolism, complete PFO closure at 6 months follow-up was significantly related to the type of closure device used

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: While there is interest in measuring the satisfaction of patients discharged from psychiatric hospitals, it might be important to determine whether surveys of psychiatric patients should employ generic or psychiatry-specific instruments. The aim of this study was to compare two psychiatric-specific and one generic questionnaires assessing patients' satisfaction after a hospitalisation in a psychiatric hospital. METHODS: We randomised adult patients discharged from two Swiss psychiatric university hospitals between April and September 2004, to receive one of three instruments: the Saphora-Psy questionnaire, the Perceptions of Care survey questionnaire or the Picker Institute questionnaire for acute care hospitals. In addition to the comparison of response rates, completion time, mean number of missing items and mean ceiling effect, we targeted our comparison on patients and asked them to answer ten evaluation questions about the questionnaire they had just completed. RESULTS: 728 out of 1550 eligible patients (47%) participated in the study. Across questionnaires, response rates were similar (Saphora-Psy: 48.5%, Perceptions of Care: 49.9%, Picker: 43.4%; P = 0.08), average completion time was lowest for the Perceptions of Care questionnaire (minutes: Saphora-Psy: 17.7, Perceptions of Care: 13.7, Picker: 17.5; P = 0.005), the Saphora-Psy questionnaire had the largest mean proportion of missing responses (Saphora-Psy: 7.1%, Perceptions of Care: 2.8%, Picker: 4.0%; P < 0.001) and the Perceptions of Care questionnaire showed the highest ceiling effect (Saphora-Psy: 17.1%, Perceptions of Care: 41.9%, Picker: 36.3%; P < 0.001). There were no differences in the patients' evaluation of the questionnaires. CONCLUSION: Despite differences in the intended target population, content, lay-out and length of questionnaires, none appeared to be obviously better based on our comparison. All three presented advantages and drawbacks and could be used for the satisfaction evaluation of psychiatric inpatients. However, if comparison across medical services or hospitals is desired, using a generic questionnaire might be advantageous.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carbon isotope ratio of androgens in urine specimens is routinely determined to exclude an abuse of testosterone or testosterone prohormones by athletes. Increasing application of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) in the last years for target and systematic investigations on samples has resulted in the demand for rapid sample throughput as well as high selectivity in the extraction process particularly in the case of conspicuous samples. For that purpose, we present herein the complimentary use of an SPE-based assay and an HPLC fractionation method as a two-stage strategy for the isolation of testosterone metabolites and endogenous reference compounds prior to GC/C/IRMS analyses. Assays validation demonstrated acceptable performance in terms of intermediate precision (range: 0.1-0.4 per thousand) and Bland-Altman analyses revealed no significant bias (0.2 per thousand). For further validation of this two-stage analyses strategy, all the specimens (n=124) collected during a major sport event were processed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: Patients with non-insulin-dependent diabetes mellitus (NIDDM) are at increased cardiovascular risk due to an accelerated atherosclerotic process. The present study aimed to compare skin microvascular function, pulse wave velocity (PWV), and a variety of hemostatic markers of endothelium injury [von Willebrand factor (vWF), plasminogen activator inhibitor-1 (PAI-1), tissue plasminogen activator (t-PA), tissue factor pathway inhibitor (TFPI), and the soluble form of thrombomodulin (s-TM)] in patients with NIDDM. METHODS: 54 patients with NIDDM and 38 sex- and age-matched controls were studied. 27 diabetics had no overt micro- and/or macrovascular complications, while the remainder had either or both. The forearm skin blood flow was assessed by laser-Doppler imaging, which allowed the measurement of the response to iontophoretically applied acetylcholine (endothelium-dependent vasodilation) and sodium nitroprusside (endothelium-independent vasodilation), as well as the reactive hyperemia triggered by the transient occlusion of the circulation. RESULTS: Both endothelial and non-endothelial reactivity were significantly blunted in diabetics, regardless of the presence or the absence of vascular complications. Plasma vWF, TFPI and s-TM levels were significantly increased compared with controls only in patients exhibiting vascular complications. Concentrations of t-PA and PAI-1 were significantly increased in the two groups of diabetics versus controls. CONCLUSION: In NIDDM, both endothelium-dependent and -independent microvascular skin reactivity are impaired, whether or not underlying vascular complications exist. It also appears that microvascular endothelial dysfunction is not necessarily associated in NIDDM with increased circulating levels of hemostatic markers of endothelial damage known to reflect a hypercoagulable state.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To improve long-term survival, prompt revascularization of the infarct-related artery should be done in patients with acute myocardial infarction (AMI); therefore, a large proportion of these patients would be hospitalized during out of hours. The clinical effects of out-of-hours AMI management were already questioned, with conflicting results. The purpose of this investigation was to compare the in-hospital outcome of patients admitted for AMI during out of hours and working hours. All patients with AMI included in the AMIS Plus Registry from January 1, 1997, to March 30, 2006, were analyzed. The working-hours group included patients admitted from 7 a.m. to 7 p.m. on weekdays, and the out-of-hours group included patients admitted from 7 p.m. to 7 a.m. on weekdays or weekends. Major cardiac events were defined as cardiovascular death, reinfarction, and stroke. The study primary end points were in-hospital death and major adverse cardiac event (MACE) rates. A total of 12,480 patients met the inclusion criteria, with 52% admitted during normal working hours, and 48%, during out of hours. Patients admitted during weekdays included more women (28.1% vs 26%; p = 0.009), older patients (65.5 +/- 13 vs 64.1 +/- 13 years; p = 0.0011), less current smokers (40.1% vs 43.5%; p <0.001), and less patients with a history of ischemic heart disease (31.5% vs 34.5%; p = 0.001). A significantly higher proportion of patients admitted during out of hours had Killip's class III and IV. No differences in terms of in-hospital survival rates between the 2 groups (91.5% vs 91.2%; p = 0.633) or MACE-free survival rates (both 88.5%; p = 1.000) were noted. In conclusion, the outcome of patients with AMI admitted out of hours was the same compared with those with a weekday admission. Of predictors for in-hospital outcome, timing of admission had no significant influence on mortality and/or MACE incidence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the first part of this research, three stages were stated for a program to increase the information extracted from ink evidence and maximise its usefulness to the criminal and civil justice system. These stages are (a) develop a standard methodology for analysing ink samples by high-performance thin layer chromatography (HPTLC) in reproducible way, when ink samples are analysed at different time, locations and by different examiners; (b) compare automatically and objectively ink samples; and (c) define and evaluate theoretical framework for the use of ink evidence in forensic context. This report focuses on the second of the three stages. Using the calibration and acquisition process described in the previous report, mathematical algorithms are proposed to automatically and objectively compare ink samples. The performances of these algorithms are systematically studied for various chemical and forensic conditions using standard performance tests commonly used in biometrics studies. The results show that different algorithms are best suited for different tasks. Finally, this report demonstrates how modern analytical and computer technology can be used in the field of ink examination and how tools developed and successfully applied in other fields of forensic science can help maximising its impact within the field of questioned documents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proteolytic activity is an important virulence factor for Candida albicans (C. albicans). It is attributed to the family of the secreted aspartic proteinases (Saps) from C. albicans with a minimum of 10 members. Saps show controlled expression and regulation for the individual stages of the infection process. Distinct isoenzymes can be responsible for adherence and tissue damage of local infections, while others cause systemic diseases. Earlier, only the structures of Sap2 and Sap3 were known. In our research, we have now succeeded in solving the X-ray crystal structures of the apoenzyme of Sap1 and Sap5 in complex with pepstatin A at 2.05 and 2.5 A resolution, respectively. With the structure of Sap1, we have completed the set of structures of isoenzyme subgroup Sap1-3. Of subgroup Sap4-6, the structure of the enzyme Sap5 is the first structure that has been described up to now. This facilitates comparison of structural details as well as inhibitor binding modes among the different subgroup members. Structural analysis reveals a highly conserved overall secondary structure of Sap1-3 and Sap5. However, Sap5 clearly differs from Sap1-3 by its electrostatic overall charge as well as through structural conformation of its entrance to the active site cleft. Design of inhibitors specific for Sap5 should concentrate on the S4 and S3 pockets, which significantly differ from Sap1-3 in size and electrostatic charge. Both Sap1 and Sap5 seem to play a major part in superficial Candida infections. Determination of the isoenzymes' structures can contribute to the development of new Sap-specific inhibitors for the treatment of superficial infections with a structure-based drug design program.