143 resultados para Concept Extraction
Resumo:
This study proposes a new concept for upscaling local information on failure surfaces derived from geophysical data, in order to develop the spatial information and quickly estimate the magnitude and intensity of a landslide. A new vision of seismic interpretation on landslides is also demonstrated by taking into account basic geomorphic information with a numeric method based on the Sloping Local Base Level (SLBL). The SLBL is a generalization of the base level defined in geomorphology applied to landslides, and allows the calculation of the potential geometry of the landslide failure surface. This approach was applied to a large scale landslide formed mainly in gypsum and situated in a former glacial valley along the Rhone within the Western European Alps. Previous studies identified the existence of two sliding surfaces that may continue below the level of the valley. In this study. seismic refraction-reflexion surveys were carried out to verify the existence of these failure surfaces. The analysis of the seismic data provides a four-layer model where three velocity layers (<1000 ms(-1), 1500 ms(-1) and 3000 ms(-1)) are interpreted as the mobilized mass at different weathering levels and compaction. The highest velocity layer (>4000 ms(-1)) with a maximum depth of similar to 58 m is interpreted as the stable anhydrite bedrock. Two failure surfaces were interpreted from the seismic surveys: an upper failure and a much deeper one (respectively 25 and 50 m deep). The upper failure surface depth deduced from geophysics is slightly different from the results obtained using the SLBL, and the deeper failure surface depth calculated with the SLBL method is underestimated in comparison with the geophysical interpretations. Optimal results were therefore obtained by including the seismic data in the SLBL calculations according to the geomorphic limits of the landslide (maximal volume of mobilized mass = 7.5 x 10(6) m(3)).
Resumo:
The National Academies has stressed the need to develop quantifiable measures for methods that are currently qualitative in nature, such as the examination of fingerprints. Current protocols and procedures to perform these examinations rely heavily on a succession of subjective decisions, from the initial acceptance of evidence for probative value to the final assessment of forensic results. This project studied the concept of sufficiency associated with the decisions made by latent print examiners at the end of the various phases of the examination process. During this 2-year effort, a web‐based interface was designed to capture the observations of 146 latent print examiners and trainees on 15 pairs of latent/control prints. Two main findings resulted from the study: The concept of sufficiency is driven mainly by the number and spatial relationships between the minutiae observed on the latent and control prints. Data indicate that demographics (training, certification, years of experience) or non‐minutiae based features (such as level 3 features) do not play a major role in examiners' decisions; Significant variability was observed between detecting and interpreting friction ridge features and at all levels of details, as well as for factors that have the potential to influence the examination process, such as degradation, distortion, or influence of the background and the development technique.
Resumo:
The goal of this study was to compare the quantity and purity of DNA extracted from biological tracesusing the QIAsymphony robot with that of the manual QIAamp DNA mini kit currently in use in ourlaboratory. We found that the DNA yield of robot was 1.6-3.5 times lower than that of the manualprotocol. This resulted in a loss of 8% and 29% of the alleles correctly scored when analyzing 1/400 and 1/800 diluted saliva samples, respectively. Specific tests showed that the QIAsymphony was at least 2-16times more efficient at removing PCR inhibitors. The higher purity of the DNA may therefore partlycompensate for the lower DNA yield obtained. No case of cross-contamination was observed amongsamples. After purification with the robot, DNA extracts can be automatically transferred in 96-wellsplates, which is an ideal format for subsequent RT-qPCR quantification and DNA amplification. Lesshands-on time and reduced risk of operational errors represent additional advantages of the robotic platform.
Resumo:
Dual mobility cup systems in total hip arthroplasty consist of a metal back with a non-constrained liner, in which a constrained standard head articulates. While superior stability of such implants in comparison with standard total hip replacements is assumed, it is the purpose of this study to outline the biomechanical concept of dual mobility cups and to describe implant survival and dislocation rate based on the series published in the English-speaking and Francophone literature. A growing body of evidence indicates reduced dislocation rates in primary and revision total hip arthroplasty and in selected tumour cases. The limited availability of studies evaluating long-term implant survival and existing concerns with regard to increased wear rates and aseptic loosening, leads to the conclusion that such implants have to be used with prudence, particularly in standard primary hip arthroplasty and in young patients.
Resumo:
ABSTRACT : A firm's competitive advantage can arise from internal resources as well as from an interfirm network. -This dissertation investigates the competitive advantage of a firm involved in an innovation network by integrating strategic management theory and social network theory. It develops theory and provides empirical evidence that illustrates how a networked firm enables the network value and appropriates this value in an optimal way according to its strategic purpose. The four inter-related essays in this dissertation provide a framework that sheds light on the extraction of value from an innovation network by managing and designing the network in a proactive manner. The first essay reviews research in social network theory and knowledge transfer management, and identifies the crucial factors of innovation network configuration for a firm's learning performance or innovation output. The findings suggest that network structure, network relationship, and network position all impact on a firm's performance. Although the previous literature indicates that there are disagreements about the impact of dense or spare structure, as well as strong or weak ties, case evidence from Chinese software companies reveals that dense and strong connections with partners are positively associated with firms' performance. The second essay is a theoretical essay that illustrates the limitations of social network theory for explaining the source of network value and offers a new theoretical model that applies resource-based view to network environments. It suggests that network configurations, such as network structure, network relationship and network position, can be considered important network resources. In addition, this essay introduces the concept of network capability, and suggests that four types of network capabilities play an important role in unlocking the potential value of network resources and determining the distribution of network rents between partners. This essay also highlights the contingent effects of network capability on a firm's innovation output, and explains how the different impacts of network capability depend on a firm's strategic choices. This new theoretical model has been pre-tested with a case study of China software industry, which enhances the internal validity of this theory. The third essay addresses the questions of what impact network capability has on firm innovation performance and what are the antecedent factors of network capability. This essay employs a structural equation modelling methodology that uses a sample of 211 Chinese Hi-tech firms. It develops a measurement of network capability and reveals that networked firms deal with cooperation between, and coordination with partners on different levels according to their levels of network capability. The empirical results also suggests that IT maturity, the openness of culture, management system involved, and experience with network activities are antecedents of network capabilities. Furthermore, the two-group analysis of the role of international partner(s) shows that when there is a culture and norm gap between foreign partners, a firm must mobilize more resources and effort to improve its performance with respect to its innovation network. The fourth essay addresses the way in which network capabilities influence firm innovation performance. By using hierarchical multiple regression with data from Chinese Hi-tech firms, the findings suggest that there is a significant partial mediating effect of knowledge transfer on the relationships between network capabilities and innovation performance. The findings also reveal that the impacts of network capabilities divert with the environment and strategic decision the firm has made: exploration or exploitation. Network constructing capability provides a greater positive impact on and yields more contributions to innovation performance than does network operating capability in an exploration network. Network operating capability is more important than network constructing capability for innovative firms in an exploitation network. Therefore, these findings highlight that the firm can shape the innovation network proactively for better benefits, but when it does so, it should adjust its focus and change its efforts in accordance with its innovation purposes or strategic orientation.
Resumo:
This minireview is meant as an introduction to the following paper. To this end, it presents the general background against which the joint paper should be understood. The first objective of the present paper is thus to clarify some concepts and related terminology, drawing a clear distinction between i) atomic diversity (i.e., atomic-property space), ii) molecular or macromolecular diversity (i.e., molecular- or macromolecular-property spaces), and iii) chemical diversity (i.e., chemical-diversity space). The first refers to the various electronic states an atom can occupy. The second encompasses the conformational and property spaces of a given (macro)molecule. The third pertains to the diversity in structure and properties exhibited by a library or a supramolecular assembly of different chemical compounds. The ground is thus laid for the content of the joint paper, which pertains to case ii, to be placed in its broader chemodiversity context. The second objective of this paper is to point to the concepts of chemodiversity and biodiversity as forming a continuum. Chemodiversity is indeed the material substratum of organisms. In other words, chemodiversity is the material condition for life to emerge and exist. Increasing our knowledge of chemodiversity is thus a condition for a better understanding of life as a process.
Resumo:
Aim Background The expected benefit of transvaginal specimen extraction is reduced incision-related morbidity. Objectives A systematic review of transvaginal specimen extraction in colorectal surgery was carried out to assess this expectation. Method Search strategy The following keywords, in various combinations, were searched: NOSE (natural orifices specimen extraction), colorectal, colon surgery, transvaginal, right hemicolectomy, left hemicolectomy, low anterior resection, sigmoidectomy, ileocaecal resection, proctocolectomy, colon cancer, sigmoid diverticulitis and inflammatory bowel diseases. Selection criteria Selection criteria included large bowel resection with transvaginal specimen extraction, laparoscopic approach, human studies and English language. Exclusion criteria were experimental studies and laparotomic approach or local excision. All articles published up to February 2011 were included. Results Twenty-three articles (including a total of 130 patients) fulfilled the search criteria. The primary diagnosis was colorectal cancer in 51% (67) of patients, endometriosis in 46% (60) of patients and other conditions in the remaining patients. A concurrent gynaecological procedure was performed in 17% (22) of patients. One case of conversion to laparotomy was reported. In two patients, transvaginal extraction failed. In left- and right-sided resections, the rate of severe complications was 3.7% and 2%, respectively. Two significant complications, one of pelvic seroma and one of rectovaginal fistula, were likely to have been related to transvaginal extraction. The degree of follow up was specified in only one study. Harvested nodes and negative margins were adequate and reported in 70% of oncological cases. Conclusion Vaginal extraction of a colorectal surgery specimen shows potential benefit, particularly when associated with a gynaecological procedure. Data from prospective randomized trials are needed to support the routine use of this technique.
Resumo:
Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.