346 resultados para CORONARY VESSELS


Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study examines cases of chronic drug users who died suddenly after drug administration. Victims were young subjects, aged from 19 to 35 from Switzerland and known to the police as long-term drug users. The circumstances of death suggested the occurrence of a sudden, unexpected death. Some victims were undergoing methadone treatment. In each case, a forensic autopsy and toxicological analyses were performed at the Institute of Forensic Medicine in Lausanne in Switzerland between 2002 and 2004, including hair analysis as a means to establish chronic drug use in general, and cocaine use in particular. The conduction system was examined histologically and cases showing potentially lethal changes were chosen for this report. The most frequent lesions found were severe thickening of the atrioventricular node artery, intranodal and perinodal fibrosis, and microscopic foci of chronic inflammatory infiltration. The authors conclude that pathological lesions in the conduction tissue may play a role in the occurrence of death attributed to intoxication consecutive to cocaine ingestion.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: CMR has recently emerged as a robust and reliable technique to assess coronary artery disease (CAD). A negative perfusion CMR test predicts low event rates of 0.3-0.5%/year. Invasive coronary angiography (CA) remains the "gold standard" for the evaluation of CAD in many countries.Objective: Assessing the costs of the two strategies in the European CMR registry for the work-up of known or suspected CAD from a health care payer perspective. Strategy 1) a CA to all patients or 2) a CA only to patients who are diagnosed positive for ischemia in a prior CMR.Method and results: Using data of the European CMR registry (20 hospitals, 11'040 consecutive patients) we calculated the proportion of patients who were diagnosed positive (20.6%), uncertain (6.5%), and negative (72.9%) after the CMR test in patients with known or suspected CAD (n=2'717). No other medical test was performed to patients who were negative for ischemia. Positive diagnosed patients had a coronary angiography. Those with uncertain diagnosis had additional tests (84.7%: stress echocardiography, 13.1%: CCT, 2.3% SPECT), these costs were added to the CMR strategy costs. Information from costs for tests in Germany and Switzerland were used. A sensibility analysis was performed for inpatient CA. For costs see figure. Results - costs.Discussion: The CMR strategy costs less than the CA strategy for the health insurance systems both, in Germany and Switzerland. While lower in costs, the CMR strategy is a non-invasive one, does not expose to radiation, and yields additional information on cardiac function, viability, valves, and great vessels. Developing the use of CMR instead of CA might imply some reduction in costs together with superior patient safety and comfort, and a better utilization of resources at the hospital level. Document introduit le : 01.12.2011

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Cx40 is a gap junction protein important for cell-cell communication in the endothelium. Polymorphisms in the promoter region of the human Cx40 gene, -44G>A and +71A>G, were shown to reduce Cx40 transcription by half. As mice with an endothelial-specific deletion of Cx40 are more susceptible to atherosclerosis, this study was designed to discover a correlation between these polymorphisms and atherosclerosis in European populations.¦METHODS AND RESULTS: 803 patients referred to the Geneva University Hospitals for elective coronary angiography were divided according to the number of significantly stenosed vessels (from 0 to 3) and were genotyped for the Cx40 polymorphisms. Genotype distribution in the control group was -44GG/+71AA=59.8%, -44AG/+71AG=35.1% and -44AA/+71GG=5.2%. Surprisingly, this distribution was similar in the CAD group, with -44GG/+71AA=58.5%, -44AG/+71AG=37.6% and -44AA/+71GG=3.8% (p=0.67). Moreover, no significant association between histological carotid plaque composition of culprit lesions and Cx40 polymorphisms could be detected in 583 Dutch patients of the Athero-Express study.¦CONCLUSIONS: Despite a clear antiatherogenic role of Cx40 in mice, our study could not detect an association of Cx40 promoter polymorphisms and CAD in human. Moreover, a correlation with atherosclerotic plaque stability or hypertension could not be demonstrated either. Connexin polymorphisms affecting channel function may be of greater importance for cardiovascular disease than polymorphisms affecting the expression level of the protein.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The purposes of this study were to (1) develop a high-resolution 3-T magnetic resonance angiography (MRA) technique with an in-plane resolution approximate to that of multidetector coronary computed tomography (MDCT) and a voxel size of 0.35 × 0.35 × 1.5 mm³ and to (2) investigate the image quality of this technique in healthy participants and preliminarily in patients with known coronary artery disease (CAD). MATERIALS AND METHODS: A 3-T coronary MRA technique optimized for an image acquisition voxel as small as 0.35 × 0.35 × 1.5 mm³ (high-resolution coronary MRA [HRC]) was implemented and the coronary arteries of 22 participants were imaged. These included 11 healthy participants (average age, 28.5 years; 5 men) and 11 participants with CAD (average age, 52.9 years; 5 women) as identified on MDCT. In addition, the 11 healthy participants were imaged using a method with a more common spatial resolution of 0.7 × 1 × 3 mm³ (regular-resolution coronary MRA [RRC]). Qualitative and quantitative comparisons were made between the 2 MRA techniques. RESULTS: Normal vessels and CAD lesions were successfully depicted at 350 × 350 μm² in-plane resolution with adequate signal-to-noise ratio (SNR) and contrast-to-noise ratio. The CAD findings were consistent among MDCT and HRC. The HRC showed a 47% improvement in sharpness despite a reduction in SNR (by 72%) and in contrast-to-noise ratio (by 86%) compared with the regular-resolution coronary MRA. CONCLUSION: This study, as a first step toward substantial improvement in the resolution of coronary MRA, demonstrates the feasibility of obtaining at 3 T a spatial resolution that approximates that of MDCT. The acquisition in-plane pixel dimensions are as small as 350 × 350 μm² with a 1.5-mm slice thickness. Although SNR is lower, the images have improved sharpness, resulting in image quality that allows qualitative identification of disease sites on MRA consistent with MDCT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: We asked whether myocardial flow reserve (MFR) by Rb-82 cardiac PET improve the selection of patients eligible for invasive coronary angiography (ICA). Material and Methods: We enrolled 26 consecutive patients with suspected or known coronary artery disease who performed dynamic Rb-82 PET/CT and (ICA) within 60 days; 4 patients who underwent revascularization or had any cardiovascular events between PET and ICA were excluded. Myocardial blood flow at rest (rMBF), at stress with adenosine (sMBF) and myocardial flow reserve (MFR=sMBF/rMBF) were estimated using the 1-compartment Lortie model (FlowQuant) for each coronary arteries territories. Stenosis severity was assessed using computer-based automated edge detection (QCA). MFR was divided in 3 groups: G1:MFR<1.5, G2:1.5≤MFR<2 and G3:2≤MFR. Stenosis severity was graded as non-significant (<50% or FFR ≥0.8), intermediate (50%≤stenosis<70%) and severe (≥70%). Correlation between MFR and percentage of stenosis were assessed using a non-parametric Spearman test. Results: In G1 (44 vessels), 17 vessels (39%) had a severe stenosis, 11 (25%) an intermediate one, and 16 (36%) no significant stenosis. In G2 (13 vessels), 2 (15%) vessels presented a severe stenosis, 7 (54%) an intermediate one, and 4 (31%) no significant stenosis. In G3 (9 vessels), 0 vessel presented a severe stenosis, 1 (11%) an intermediate one, and 8 (89%) no significant stenosis. Of note, among 11 patients with 3-vessel low MFR<1.5 (G1), 9/11 (82%) had at least one severe stenosis and 2/11 (18%) had at least one intermediate stenosis. There was a significant inverse correlation between stenosis severity and MFR among all 66 territories analyzed (rho= -0.38, p=0.002). Conclusion: Patients with MFR>2 could avoid ICA. Low MFR (G1, G2) on a vessel-based analysis seems to be a poor predictor of severe stenosis severity. Patients with 3-vessel low MFR would benefit from ICA as they are likely to present a significant stenosis in at least one vessel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Though rare, anomalous coronary artery disease is a well-known cause of myocardial ischemia and sudden death among children and young adults. The projectional nature of conventional x-ray angiography often leads to difficulty in the definition of anomalous vessels. Studies have now documented the high accuracy of coronary magnetic resonance angiography (MRA) for the noninvasive detection and definition of anomalous coronary arteries among patients with suspected anomalous coronary arteries of congenital conditions associated with anomalous coronary arteries. With increasing clinical experience, coronary MRA will likely emerge as the gold standard for the diagnosis of this condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare postmortem angiography-based, autopsy-based and histology-based diagnoses of acute coronary thrombosis in a series of medicolegal cases that underwent postmortem angiographies according to multiphase CT-angiography protocol. Our study included 150 medicolegal cases. All cases underwent native CT-scan, postmortem angiography, complete conventional autopsy and histological examination of the main organs and coronary arteries. In 10 out of the 150 investigated cases, postmortem angiographies revealed coronary arterial luminal filling defects and the absence of collateral vessels, suggesting acute coronary thromboses. Radiological findings were confirmed by autopsy and histological examinations in all cases. In 40 out of 150 cases, angiograms revealed complete or incomplete coronary arterial luminal filling defects and the presence of collateral vessels. Histological examinations did not reveal free-floating or non-adherent thrombi in the coronary arteries in any of these cases. Though postmortem angiography examination has not been well-established for the diagnosis of acute coronary thrombosis, luminal filling defects in coronary arteries suggesting acute thromboses can be observed through angiography and subsequently confirmed by autopsy and histological examinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A single coronary artery can complicate the surgical technique of arterial switch operations, impairing early and late outcomes. We propose a new surgical approach, successfully applied in a 2.1 kg neonate, aimed at reducing the risk of early and late compression and/or distortion of the newly constructed coronary artery system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Percutaneous coronary interventions (PCI) are frequently performed before coronary artery bypass graft (CABG) surgery. This study sought to evaluate postoperative outcomes, and incidence of recurrent target ischemia in vessels with prior PCI in patients who had PCI prior to CABG compared to only CABG patients. METHODS: A review included CABG patients operated from 2000 to 2012. PCI prior to CABG patients were compared with patients having had CABG on native coronary arteries. Demographic and risk factors, including hospital morbidity, mortality, and recurrent target vessel ischemia at follow-up (FU), were compared. Major end-points were statistical differences of postoperative morbidity and reintervention rates due to symptomatic graft failure or target vessel ischemia during FU. RESULTS: Twenty-four percent of 1669 isolated CABG patients had PCI prior to CABG, with an increasing percentage during recent years. Demographics, risk factors, comorbidities and mortality rates were similar. Incidence of postoperative hemorrhage (OR 1.9; 95% CI 1.1-3.2; p = 0.02), perioperative myocardial infarction rate (p = 0.02), neurological deficits (OR 3.5; 95% CI 1.2-9.7; p = 0.02) and re-intervention rate for symptomatic graft or target vessel occlusion were higher in pretreated patients (OR 1.8; 95% CI 1.1-3.0; p = 0.01). CONCLUSIONS: PCI prior to CABG increases the risk for postoperative morbidity. Increased postoperative hemorrhage could be attributed to ongoing double anti-platelet therapy. doi: 10.1111/jocs.12514 (J Card Surg 2015;30:313-318).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of a 71-year-old man with a long coronary artery disease history and two sets of coronary artery bypass grafts. He developed large aortocoronary saphenous vein graft aneurysms in the two grafts from the first set of aortocoronary saphenous venous 20 years later. During the previous 3 years, the aneurysms grew in diameter from 22 to 50 mm. Because of severe renal insufficiency, and in order to avoid jeopardizing the late normal coronary artery bypass grafts by further thoracic surgery, we excluded successfully these altered grafts percutaneously by using 13 coils during the same procedure.