105 resultados para Alternative jsutice


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The M-Coffee server is a web server that makes it possible to compute multiple sequence alignments (MSAs) by running several MSA methods and combining their output into one single model. This allows the user to simultaneously run all his methods of choice without having to arbitrarily choose one of them. The MSA is delivered along with a local estimation of its consistency with the individual MSAs it was derived from. The computation of the consensus multiple alignment is carried out using a special mode of the T-Coffee package [Notredame, Higgins and Heringa (T-Coffee: a novel method for fast and accurate multiple sequence alignment. J. Mol. Biol. 2000; 302: 205-217); Wallace, O'Sullivan, Higgins and Notredame (M-Coffee: combining multiple sequence alignment methods with T-Coffee. Nucleic Acids Res. 2006; 34: 1692-1699)] Given a set of sequences (DNA or proteins) in FASTA format, M-Coffee delivers a multiple alignment in the most common formats. M-Coffee is a freeware open source package distributed under a GPL license and it is available either as a standalone package or as a web service from www.tcoffee.org.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Common variable Immunodeficiency (CVID) is next to the selective IgA-deficiency the most frequent primary immunodeficiency syndrome. Because of its variable clinical manifestations and age of declaration, CVID can mimic different other pathologies and is therefore frequently diagnosed in a later stage of the disease. However, as a consequence of late diagnosis, irreversible organ damage can have occurred which could have been prevented by early treatment. Therefore, early diagnosis of CVID by the general practitioner in patients with recurrent infections or other typical clinical manifestations is of great importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative method based on the detectability index (d') calculated for a non-prewhitened model observer with an eye filter (NPWE). The detectability index was calculated from the normalized noise power spectrum and image contrast, both measured from an image of a 5 cm poly(methyl methacrylate) phantom containing a 0.2 mm thick aluminium square, and the pre-sampling modulation transfer function. This was performed as a function of air kerma at the detector for 11 different digital mammography systems. These calculated d' values were compared against threshold gold thickness (T) results measured with the CDMAM test object and against derived theoretical relationships. A simple relationship was found between T and d', as a function of detector air kerma; a linear relationship was found between d' and contrast-to-noise ratio. The values of threshold thickness used to specify acceptable performance in the European Guidelines for 0.10 and 0.25 mm diameter discs were equivalent to threshold calculated detectability indices of 1.05 and 6.30, respectively. The NPWE method is a validated alternative to CDMAM scoring for use in the image quality specification, quality control and optimization of digital x-ray systems for screening mammography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In 2004, complementary and alternative medicine (CAM) was offered by physicians in one third of Swiss hospitals. Since then, CAM health policy has considerably changed. This study aims at describing the present supply and use of CAM in hospitals of the French-speaking part of Switzerland, and qualitatively explores the characteristics of this supply. Methods: Between June 2011 and March 2012, a short questionnaire was sent to the medical directors of hospitals (N=46), asking them whether a CAM was offered, where and by whom. Then, a semi-directive interview was conducted with 10 CAM therapists. Results: Among 37 responses (return rate 80%), 19 medical directors indicated that their hospital offered at least one CAM and 18 reported that they did not. Acupuncture was the most frequently proposed CAM, followed by manual therapies, osteopathy and aromatherapy. The disciplines that offered CAM most frequently were rehabilitation, gynaecology- obstetrics, palliative care, psychiatry and anaesthesiology. In eight out of ten interviews, it appeared that the procedures for introducing a CAM in the hospital were not tightly supervised by the hospital but were mainly based on the goodwill of the therapists, rather than clinical/scientific evidence. Conclusion: Hospitals offering CAM in the French-speaking part of Switzerland seems to have risen since 2004. The selection of CAM to be offered in a hospital should be based on the same procedure of evaluation and validation as conventional care, and if their safety and efficiency is evidence-based, they should receive the same structural resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While a popular vote supported a new article on complementary and alternative medicines (CAM) in the Swiss Constitution, this assessment in 14 wards of the University Hospital of Lausanne, Switzerland, attempted at answering the question: How can CAM use be better taken into account and patients informed with more rigor and respect for their choices? Confronted with a review of the literature (> 2000 publications in "Evidence-based complementary medicines" since 1998), respondents declared their ignorance of the clinical data presently available on CAM. All were in favour of more teaching and information on the subject, plus an official statement from the Hospital direction, ensuring production and diffusion of rigorous and clinically significant information on CAM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alternative splicing (AS) has the potential to greatly expand the functional repertoire of mammalian transcriptomes. However, few variant transcripts have been characterized functionally, making it difficult to assess the contribution of AS to the generation of phenotypic complexity and to study the evolution of splicing patterns. We have compared the AS of 309 protein-coding genes in the human ENCODE pilot regions against their mouse orthologs in unprecedented detail, utilizing traditional transcriptomic and RNAseq data. The conservation status of every transcript has been investigated, and each functionally categorized as coding (separated into coding sequence [CDS] or nonsense-mediated decay [NMD] linked) or noncoding. In total, 36.7% of human and 19.3% of mouse coding transcripts are species specific, and we observe a 3.6 times excess of human NMD transcripts compared with mouse; in contrast to previous studies, the majority of species-specific AS is unlinked to transposable elements. We observe one conserved CDS variant and one conserved NMD variant per 2.3 and 11.4 genes, respectively. Subsequently, we identify and characterize equivalent AS patterns for 22.9% of these CDS or NMD-linked events in nonmammalian vertebrate genomes, and our data indicate that functional NMD-linked AS is more widespread and ancient than previously thought. Furthermore, although we observe an association between conserved AS and elevated sequence conservation, as previously reported, we emphasize that 30% of conserved AS exons display sequence conservation below the average score for constitutive exons. In conclusion, we demonstrate the value of detailed comparative annotation in generating a comprehensive set of AS transcripts, increasing our understanding of AS evolution in vertebrates. Our data supports a model whereby the acquisition of functional AS has occurred throughout vertebrate evolution and is considered alongside amino acid change as a key mechanism in gene evolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY OBJECTIVES: Traditionally, sleep studies in mammals are performed using electroencephalogram/electromyogram (EEG/EMG) recordings to determine sleep-wake state. In laboratory animals, this requires surgery and recovery time and causes discomfort to the animal. In this study, we evaluated the performance of an alternative, noninvasive approach utilizing piezoelectric films to determine sleep and wakefulness in mice by simultaneous EEG/EMG recordings. The piezoelectric films detect the animal's movements with high sensitivity and the regularity of the piezo output signal, related to the regular breathing movements characteristic of sleep, serves to automatically determine sleep. Although the system is commercially available (Signal Solutions LLC, Lexington, KY), this is the first statistical validation of various aspects of sleep. DESIGN: EEG/EMG and piezo signals were recorded simultaneously during 48 h. SETTING: Mouse sleep laboratory. PARTICIPANTS: Nine male and nine female CFW outbred mice. INTERVENTIONS: EEG/EMG surgery. MEASUREMENTS AND RESULTS: The results showed a high correspondence between EEG/EMG-determined and piezo-determined total sleep time and the distribution of sleep over a 48-h baseline recording with 18 mice. Moreover, the piezo system was capable of assessing sleep quality (i.e., sleep consolidation) and interesting observations at transitions to and from rapid eye movement sleep were made that could be exploited in the future to also distinguish the two sleep states. CONCLUSIONS: The piezo system proved to be a reliable alternative to electroencephalogram/electromyogram recording in the mouse and will be useful for first-pass, large-scale sleep screens for genetic or pharmacological studies. CITATION: Mang GM, Nicod J, Emmenegger Y, Donohue KD, O'Hara BF, Franken P. Evaluation of a piezoelectric system as an alternative to electroencephalogram/electromyogram recordings in mouse sleep studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The low 137Cs activity observed in marine sediments of tropical regions often precludes its use as chronostratigraphic marker. Here we present a study on the use of Pu and Am radioisotopes as alternative markers to constrain the 210Pb ages in a sediment core of the Havana Bay (Cuba). Mean activity ratios of 238Pu/239,240Pu, 241Am/239,240Pu and 241Pu/239,240Pu indicated that the nuclear weapon tests fallout is the main source of the anthropogenic radionuclides. While the inventory of 137Cs in the sediments is lower than the expected fallout inventory, 239,240Pu accumulates in the sediments with inventories higher than the expected fallout inventory. The high fluxes of 239,240Pu are nevertheless corroborated here through use of 210Pb, and confirm that focusing of solid particles is of great importance in the investigated site. 239,240Pu showed to be a useful time tracer in marine sites where the 137Cs signal is very low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of our multidisciplinary study was to define a pragmatic and secure alternative to the creation of a national centralised medical record which could gather together the different parts of the medical record of a patient scattered in the different hospitals where he was hospitalised without any risk of breaching confidentiality. Methods We first analyse the reasons for the failure and the dangers of centralisation (i.e. difficulty to define a European patients' identifier, to reach a common standard for the contents of the medical record, for data protection) and then propose an alternative that uses the existing available data on the basis that setting up a safe though imperfect system could be better than continuing a quest for a mythical perfect information system that we have still not found after a search that has lasted two decades. Results We describe the functioning of Medical Record Search Engines (MRSEs), using pseudonymisation of patients' identity. The MRSE will be able to retrieve and to provide upon an MD's request all the available information concerning a patient who has been hospitalised in different hospitals without ever having access to the patient's identity. The drawback of this system is that the medical practitioner then has to read all of the information and to create his own synthesis and eventually to reject extra data. Conclusions Faced with the difficulties and the risks of setting up a centralised medical record system, a system that gathers all of the available information concerning a patient could be of great interest. This low-cost pragmatic alternative which could be developed quickly should be taken into consideration by health authorities.