209 resultados para ultrasound assisted dissolution-evaporation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Adherence to preventive measures and prescribed medications is the cornerstone of the successful management of hypertension. The role of adherence is particularly important when treatments are not providing the expected clinical results, for example, in patients with resistant hypertension. The goal of this article is to review the recent observations regarding drug adherence in resistant hypertension. RECENT FINDINGS: Today, the role of drug adherence as a potential cause of resistant hypertension is largely underestimated. Most studies suggest that a low adherence to the prescribed medications can affect up to 50% of patients with resistant hypertension.A good adherence to therapy is generally associated with an improved prognosis. Nonetheless, adherence should probably not be a target for treatment per se because data on adherence should always be interpreted in the view of clinical results. In our opinion, the availability of reliable data on drug adherence would be a major help for physicians to manage patients apparently resistant to therapy. SUMMARY: The actual development of new drugs for hypertension is slow. Thus, focusing on drug adherence to the drugs available is an important way to improve blood pressure control in the population. More emphasis should be put on measuring drug adherence in patients with resistant hypertension to avoid costly investigations and treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this study is to describe the prenatal sonographic features and the results of DNA analysis on three fetuses with dyssegmental dysplasia, Silverman-Handmaker type (DD-SH). METHODS: A retrospective review of three fetuses with confirmed DD-SH was conducted. The fetal ultrasound findings, the radiological characteristics, and the results of the mutation analysis of the heparan sulphate perlecan gene 2 (HSPG2) were reviewed. RESULTS: There were three cases in two families with DD-SH diagnosed prenatally. The main prenatal ultrasound and the radiological features of DD-SH were severe limb shortening and vertebral segmentation and fusion defects (anisospondyly). The DNA analysis of the HSPG2 gene showed that the two affected fetuses in a nonconsanguineous family had a compound heterozygote for the c.646G > T transversion in exon 7 and a c.5788C > T transition in exon 46. The fetus born to the consanguineous couple had a homozygous mutation c.1356-27_1507 + 59del. CONCLUSION: DD-SH can be diagnosed prenatally using fetal ultrasound as early as 13 weeks. Xrays and DNA analysis of the HSPG2 gene are important for the confirmation of the diagnosis and for the preimplantation and prenatal diagnosis in pregnancies at risk. © 2013 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Ultrasound Biomicroscopy (UBM) is a new ophthalmological imaging technique essentially designed for the study of the anterior eye segment. Over the last 10 months, we've evaluated its contribution to the conservative treatment of anterior uveal melanoma's by means of accelerated proton beam irradiation. MATERIAL: Using UBM, we have examined 55 cases of uveal melanoma's, whose anterior border was situated at 6 mm or less from the limbus and that were consequently treated by proton beam irradiation. RESULTS: The presumed tumoral origin was the ciliary body's pars plicata in 13 cases and the pars plana or the choroid in 42 cases, 17 of which presented a tumoral invasion of the pars plicata. A pars plana detachment anterior to or surrounding the anterior tumoral border, was present in 22 cases. The height of the tumor could only be measured by UBM if it was less than 2.5 mm. Information gathered using UBM have contributed to an improvement of the therapy plan in 32 cases. CONCLUSION: Because of the strong attenuation of the high frequency ultrasound signal, UBM can only be used for the examination of intra-ocular structures situated in direct neighbourhood to the global wall. Despite this technical limitation, ist contribution to the planning of the conservative treatment of anterior uveal melanoma's by proton beam irradiation has appeared to be considerable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE.: Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. INTERVENTIONS.: In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. RESULTS.: Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. CONCLUSIONS.: The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe low mechanical index grey scale contrast enhanced breast ultrasound in patients with intraductal echogenic material in the differentiation of papillomas from intraductal secretions. Methods and materials: In five patients with echographically detected ductal dilatation containing echogenic material low mechanical index grey scale contrast enhanced ultrasonography was performed. No patient had nipple discharge. The examination was performed with a 9 MHz linear transducer after injection of 4 ml of Sonovue. It was assessed if contrast enhancement was present or not. The results were correlated with histologic results after surgical resection or percutaneous biopsy when performed. Results: In 3 patients contrast enhancement was observed. These patients were operated and the papillomas confirmed by histology. In two patients no contrast enhancement was observed. In one of these two patients percutaneous biopsy was performed without evidence of a papillary lesion. The second patient presented with multiple dilated ducts containing echogenic material. No biopsy was performed but breast MRI showed no intraductal enhancement supporting the non papillary nature of the intraductal material. Conclusion: This pilot study shows that contrast enhanced ultrasound is able to detect the vascularisation of papillomas and that it may differentiate intraductal papillomas from secretions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies in humans have demonstrated a relationship between pathological events during fetal development and increased cardiovascular risk later in life and have led to the so called "Fetal programming of cardiovascular disease hypothesis". The recent observation of generalised vascular dysfunction in young apparently healthy children conceived by assisted reproductive technologies (ART) provides a novel and potentially very important example of this hypothesis. This review summarises recent data in ART children demonstrating premature subclinical atherosclerosis in the systemic circulation and pulmonary vascular dysfunction predisposing to exaggerated hypoxia-induced pulmonary hypertension. These problems appear to be related to the ART procedure per se. Studies in ART mice demonstrating premature vascular aging and arterial hypertension further demonstrate the potential of ART to increase cardiovascular risk and have allowed to unravel epigenetic alterations of the eNOS gene as an underpinning mechanism. The roughly 25% shortening of the life span in ART mice challenged with a western style high-fat-diet demonstrates the potential importance of these alterations for the long-term outcome. Given the young age of the ART population, data on cardiovascular endpoints will not be available before 20 to 30 years from now. However, already now cohort studies of the ART population are needed to early detect cardiovascular alterations with the aim to prevent or at least optimally treat cardiovascular complications. Finally, a debate needs to be engaged on the future of ART and the consequences of its exponential growth for public health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Ultrasound scan in the mid-trimester of pregnancy is now a routine part of prenatal care in most European countries. The objective of this study was to evaluate the prenatal diagnosis of dysmorphic syndromes by fetal ultrasound examination. METHODS: Data from 20 registries of congenital malformations in 12 European countries were included in the study. RESULTS: There were 2454 cases with congenital heart diseases, 479 of which were recognized syndromes, including 375 chromosomal anomalies and 104 syndromes without chromosomal anomalies. Fifty-one of the 104 were detected prenatally (49.0%). One hundred and ninety-two of 1130 cases with renal anomalies were recognized syndromes, including 128 chromosomal anomalies and 64 syndromes without chromosomal anomalies; 162 of them (84.4%) were diagnosed prenatally, including 109 chromosomal anomalies and 53 non-chromosomal syndromes. Fifty-four of the 250 cases with limb defects were recognized syndromes, including 16 chromosomal syndromes and 38 syndromes without chromosomal anomalies; 21 of these 54 syndromes were diagnosed prenatally (38.9%), including 9 chromosomal syndromes. There were 243 cases of abdominal wall defects including 57 recognizable syndromes, 48 with omphalocele and 9 with gastroschisis; 48 were diagnosed prenatally (84.2%). Twenty-six of the 187 cases with diaphragmatic hernia had recognized syndromes, including 20 chromosomal aberrations and 6 syndromes without chromosomal anomalies. Twenty-two of them (84.6%) were detected prenatally. Sixty-four of 349 cases with intestinal anomalies were recognized syndromes; 24 were diagnosed prenatally (37.5%). There were 553 cases of cleft lip and palate (CL(P)) and 198 of cleft palate (CP) including 74 chromosomal anomalies and 73 recognized non-chromosomal syndromes. Prenatal diagnosis was made in 51 cases of CL(P) (53.7%) and 7 of CP (13.7%). Twenty-two of 188 anencephalic cases were syndromic and all were diagnosed prenatally. Of 290 cases with spina bifida, 18 were recognized syndromes, and of them 17 were diagnosed prenatally. All 11 syndromic encephaloceles were diagnosed prenatally. CONCLUSIONS: Around 50% of the recognized syndromes which are associated with major congenital anomalies (cardiac, renal, intestinal, limb defects, abdominal wall defects and oral clefts) can be detected prenatally by the anomaly scan. However the detection rate varies with the type of syndrome and with the different countries' policies of prenatal screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The information gathered with intravascular ultrasound (IVUS) are of great value in endovascular techniques. The aim of this study was to evaluate the reliability of IVUS when measuring vessel dimensions by comparison with an established reference method. The left carotid artery was exposed in 4 pigs (45-55 kg) and two piezoelectric crystals were sutured on the adventitia in the same cross-sectional plane. The distance between them was measured either by IVUS and by sonomicrometers. The mean distance between the two crystals calculated by the sonomicrometer was 4.7+/-0.4 mm (mean systolic distance was 4.9+/-0.2 mm, mean diastolic distance was 4.6+/-0.1 mm). The mean distance between the two targets calculated by IVUS was 4. 5+/-0.2 mm (mean systolic distance was 4.6+/-0.2 mm and mean diastolic 4.4+/-0.2 mm). Regression analysis of the two series of data shows a R(2)=0.9984. IVUS measurements are an average 5% smaller than sonomicrometer measurements (3.6% up to 8.3%) and the difference is statistically significant ( p <0.05). The underestimation of IVUS measurements will affect the accuracy, and probably the long-term outcome, of endovascular procedures.