103 resultados para swing check valve
Resumo:
Lung volume reduction with valves is increasingly used to treat selected patients with severe emphysema. The indications for this procedure have been previously described; however, its contraindications have not yet been conclusively established. This case highlights the potentially severe complications of endobronchial one-way valve placement in the setting of a previous pleurodesis.
Resumo:
The expression of Staphylococcus aureus adhesins in Lactococcus lactis identified clumping factor A (ClfA) and fibronectin-binding protein A (FnBPA) as critical for valve colonization in rats with experimental endocarditis. This study further analyzed their role in disease evolution. Infected animals were followed for 3 d. ClfA-positive lactococci successfully colonized damaged valves, but were spontaneously eradicated over 48 h. In contrast, FnBPA-positive lactococci progressively increased bacterial titers in vegetations and spleens. At imaging, ClfA-positive lactococci were restricted to the vegetations, whereas FnBPA-positive lactococci also invaded the adjacent endothelium. This reflected the capacity of FnBPA to trigger cell internalization in vitro. Because FnBPA carries both fibrinogen- and fibronectin-binding domains, we tested the role of these functionalities by deleting the fibrinogen-binding domain of FnBPA and supplementing it with the fibrinogen-binding domain of ClfA in cis or in trans. Deletion of the fibrinogen-binding domain of FnBPA did not alter fibronectin binding and cell internalization in vitro. However, it totally abrogated valve infectivity in vivo. This ability was restored in cis by inserting the fibrinogen-binding domain of ClfA into truncated FnBPA, and in trans by coexpressing full-length ClfA and truncated FnBPA on two separate plasmids. Thus, fibrinogen and fibronectin binding could cooperate for S. aureus valve colonization and endothelial invasion in vivo.
Resumo:
Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.
Resumo:
The stable carbon and oxygen isotope compositions of fossil ostracods are powerful tools to estimate past environmental and climatic conditions. The basis for such interpretations is that the calcite of the valves reflects the isotopic composition of water and its temperature of formation. However, calcite of ostracods is known not to form in isotopic equilibrium with water and different species may have different offsets from inorganic precipitates of calcite formed under the same conditions. To estimate the fractionation during ostracod valve calcification, the oxygen and carbon isotope compositions of 15 species living in Lake Geneva were related to their autoecology and the environmental parameters measured during their growth. The results indicate that: (1) Oxygen isotope fractionation is similar for all species of Candoninae with an enrichment in 18O of more than 30/00 relative to equilibrium values for inorganic calcite. Oxygen isotope fractionation for Cytheroidea is less discriminative relative to the heavy oxygen, with enrichments in 18O for these species of 1.7 to 2.30/00. Oxygen isotope fractionations for Cyprididae are in-between those of Candoninae and Cytheroidea. The difference in oxygen isotope fractionation between ostracods and inorganic calcite has been interpreted as resulting from a vital effect. (2) Comparison with previous work suggests that oxygen isotope fractionation may depend on the total and relative ion content of water. (3) Carbon isotope compositions of ostracod valves are generally in equilibrium with DIC. The specimens' δ13C values are mainly controlled by seasonal variations in δ13CDIC of bottom water or variation thereof in sediment pore water. (4) Incomplete valve calcification has an effect on carbon and oxygen isotope compositions of ostracod valves. Preferential incorporation of at the beginning of valve calcification may explain this effect. (5) Results presented here as well as results from synthetic carbonate growth indicate that different growth rates or low pH within the calcification site cannot be the cause of oxygen isotope 'vital effects' in ostracods. Two mechanisms that might enrich the 18O of ostracod valves are deprotonation of that may also contribute to valve calcification, and effects comparable to salt effects with high concentrations of Ca and/or Mg within the calcification site that may also cause a higher temperature dependency of oxygen isotope fractionation.
Resumo:
The directional flow of lymph is maintained by hundreds of intraluminal lymphatic valves. Lymphatic valves are crucial to prevent lymphedema, accumulation of fluid in the tissues, and to ensure immune surveillance; yet, the mechanisms of valve formation are only beginning to be elucidated. In this chapter, we will discuss the main steps of lymphatic valve morphogenesis, the important role of mechanotransduction in this process, and the genetic program regulated by the transcription factor Foxc2, which is indispensable for all steps of valve development. Failure to form mature collecting lymphatic vessels and valves causes the majority of postsurgical lymphedema, e.g., in breast cancer patients. Therefore, this knowledge will be useful for diagnostics and development of better treatments of secondary lymphedema.
Resumo:
Transapical aortic valve implantation is indicated in high-risk patients with aortic stenosis and peripheral vascular disease requiring aortic valve replacement. Minimally invasive direct coronary artery bypass grafting is also a valid, minimally invasive option for myocardial revascularization in patients with critical stenosis on the anterior descending coronary artery. Both procedures are performed through a left minithoracotomy, without cardiopulmonary bypass, aortic cross-clamping, and cardioplegic arrest. We describe a successful combined transapical aortic valve implantation and minimally invasive direct coronary bypass in a high-risk patient with left anterior descending coronary artery occlusion and severe aortic valve stenosis.
Resumo:
The transapical transcatheter aortic valve implantation (TA-TAVI) in degenerated aortic bioprosthesis is an emerging therapy for surgically non-amenable patients. However, the presence of different types of aortic bioprostheses (stented and stentless), available in different sizes (19-27 mm), can be at the origin of important mismatches between the malfunctioning, degenerated aortic valves and the inner stent-valves implanted through transapical accesses (23 and 26 mm Edwards Sapien transcatheter stent-valves). We report an emergency TA-TAVI treatment of a severely regurgitant degenerated 23 mm Mitroflow aortic bioprosthesis (Sorin Group, Milano, Italy) implanted seven years earlier in an 80-year-old lady, and we reviewed the current available literature about transapical 'valve-in-valve' procedures to analyze the hemodynamic results and the ideal 'prosthesis-to-prosthesis' match.
Resumo:
Transapical transcatheter aortic valve implantation is an emerging technique for high-risk patients with symptomatic aortic valve stenosis, peripheral vascular disease, and severe concomitant comorbidities. However, a previous major surgical intervention involving the left hemithorax and the lung has always been considered a technical surgical challenge or even a potential contraindication for this minimally invasive procedure. With this report, we demonstrate, for the first time, that a previous left pneumonectomy followed by mediastinal radiotherapy does not affect the feasibility of transapical transcatheter aortic valve implantation, and we discuss the preoperative workup and the peculiar intraoperative cardiac imaging and surgical assessment.
Resumo:
BACKGROUND: Diastolic dysfunction with delayed relaxation and abnormal passive elastic properties has been described in patients with severe pressure overload hypertrophy. The purpose of this study was to evaluate the time course of rotational motion of the left ventricle in patients with aortic valve stenosis using myocardial tagging. METHODS: Myocardial tagging is a non-invasive method based on magnetic resonance which makes it possible to label ('tag') specific myocardial regions. From the motion of the tag's cardiac rotation, radial displacement and translational motion can be determined. In 12 controls and 13 patients with severe aortic valve stenosis systolic and diastolic wall motion was assessed in an apical and basal short axis plane. RESULTS: The normal left ventricle performs a systolic wringing motion around the ventricular long axis with clockwise rotation at the base (-4.4+/-1.6 degrees) and counter-clockwise rotation at the apex (+6.8+/-2.5 degrees) when viewed from the apex. During early diastole an untwisting motion can be observed which precedes diastolic filling. In patients with aortic valve stenosis systolic rotation is reduced at the base (-2.4+/-2.0 degrees; P<0.01) but increased at the apex (+12.0+/-6.0 degrees; P<0.05). Diastolic untwisting is delayed and prolonged with a decrease in normalized rotation velocity (-6.9+/-1.1 s(-1)) when compared to controls (-10.7+/-2.2 s(-1); P<0.001). Maximal systolic torsion is 8.0+/-2.1 degrees in controls and 14.1+/-6.4 degrees (P<0.01) in patients with aortic valve stenosis. CONCLUSIONS: Left ventricular pressure overload hypertrophy is associated with a reduction in basal and an increase in apical rotation resulting in increased torsion of the ventricle. Diastolic untwisting is delayed and prolonged. This may explain the occurrence of diastolic dysfunction in patients with severe pressure overload hypertrophy.
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
AIMS: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. METHODS AND RESULTS: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm²) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). CONCLUSIONS: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.
Resumo:
BACKGROUND: Aortoplasty has been advocated for moderate dilatation of the ascending aorta associated with aortic valve disease. We report our results with this conservative approach. METHODS: Seventeen consecutive patients with unsupported aortoplasty were reviewed. Twelve patients had aortic valve regurgitation and 5 had stenosis. The aortic wall was analyzed histologically in 14 patients. Follow-up was complete, with a mean time of 6 years (range, 2.3 to 10.5 years). RESULTS: Two patients among the 15 hospital survivors died during follow-up of causes unrelated to aortic pathology. Survival at 7 years was 86.7% (+/- 8.8%). Recurring aortic aneurysms developed in 4 patients after a mean time of 63 months, with an event-free survival at 7 years of 41% (+/- 21%). All of these 4 patients had aortic valve regurgitation and cystic medial necrosis. CONCLUSIONS: The recurrence rate of aneurysms after unsupported aortoplasty and aortic valve replacement is high in patients with aortic regurgitation. This strongly suggests that in these patients, the aortic dilatation is related to an underlying wall deficiency, associated with the aortic valve pathology, rather than to the hemodynamic stress imposed by the aortic valve disease.
Resumo:
PURPOSE OF REVIEW: The safety and efficiency of trans catheter aortic valve implantation (TAVI) has been clearly demonstrated. In high-risk patients, the number of procedures is constantly increasing and in western European countries this procedure is employed in more than 30% of isolated aortic valve replacements. The literature, however, focusing on perioperative aortic root (AoR) rupture is rather limited to just a few reports. The aim of this review is to analyze the pathophysiology of AoR rupture during TAVI, stressing the implications of the morphology of the AoR for this devastating complication. RECENT FINDINGS: Currently, perioperative AoR rupture ranges between 0.5 and 1.5% during TAVI, with almost 100% mortality. Recently, valve oversizing and balloon dilatation in a calcified and small AoR were considered as the most important predictive factors for this complication. SUMMARY: The most fragile unit of the AoR is its anchoring substrate to the ostium of the left ventricle. This membranous structure is not involved in the degenerative process leading to aortic valve stenosis. Due to the TAVI and/or balloon dilatation of the calcium stationed on the three leaflets and their attachment, a lesion may result on this structure. And, as a consequence, there is rupture of the AoR.