91 resultados para solid amounts
Resumo:
Since new technologies based on solid phase assays (SPA) have been routinely incorporated in the transplant immunology laboratory, the presence of pretransplantation donor-specific antibodies (DSA) against human leukocyte antigen (HLA) molecules has generally been considered as a risk factor for acute rejection (AR) and, in particular, for acute humoral rejection (AHR). We retrospectively studied 113 kidney transplant recipients who had negative prospective T-cell and B-cell complement-dependent cytotoxicity (CDC) crossmatches at the time of transplant. Pretransplantation sera were screened for the presence of circulating anti-HLA antibody and DSA by using highly sensitive and HLA-specific Luminex assay, and the results were correlated with AR and AHR posttransplantation. We found that approximately half of our patient population (55/113, 48.7%) had circulating anti-HLA antibody pretransplantation. Of 113 patients, 11 (9.7%) had HLA-DSA. Of 11 rejection episodes post-transplant, only two patients had pretransplantation DSA, of whom one had a severe AHR (C4d positive). One-year allograft survival was similar between the pretransplantation DSA-positive and -negative groups. Number, class, and intensity of pretransplantation DSA, as well as presensitizing events, could not predict AR. We conclude that, based on the presence of pretransplantation DSA, post-transplantation acute rejections episodes could not have been predicted. The only AHR episode occurred in a recipient with pretransplantation DSA. More work should be performed to better delineate the precise clinical significance of detecting low titers of DSA before transplantation.
Resumo:
Since the early 1980s high dose chemotherapy with autologous hematopoietic stem cell support was adopted by many oncologists as a potentially curative option for solid tumors, supported by a strong rationale from laboratory studies and apparently convincing results of early phase II studies. As a result, the number and size of randomized trials comparing this approach with conventional chemotherapy initiated (and often abandoned before completion) to prove or disprove its value was largely insufficient. In fact, with the possible exception of breast carcinoma, the benefit of a greater escalation of dose of chemotherapy with stem cell support in solid tumors is still unsettled and many oncologists believe that this approach should cease. In this article, we critically review and comment on the data from studies of high dose chemotherapy so far reported in adult patients with small cell lung cancer, ovarian cancer, germ cell tumors and sarcomas.
Resumo:
Over the past few years, the therapeutic potential of Treg has been highlighted in the field of autoimmune diseases and after allogeneic transplantation. The first hurdle for the therapeutic use of Treg is their insufficient numbers in non-manipulated individuals, in particular when facing strong immune activation and expanding effector cells, such as in response to an allograft. Here we review current approaches being explored for Treg expansion in the perspective of clinical therapeutic protocols. We describe different Treg subsets that could be suitable for clinical application, as well as discuss factors such as the required dose of Treg, their antigen-specificity and in vivo stability, that have to be considered for optimal Treg-based immunotherapy in transplantation. Since Treg may not be sufficient as stand-alone therapy for solid organ transplantation in humans, we draw attention to possible hurdles and combination therapy with immunomodulatory drugs that could possibly improve the in vivo efficacy of Treg.
Resumo:
In addition to the importance of sample preparation and extract separation, MS detection is a key factor in the sensitive quantification of large undigested peptides. In this article, a linear ion trap MS (LIT-MS) and a triple quadrupole MS (TQ-MS) have been compared in the detection of large peptides at subnanomolar concentrations. Natural brain natriuretic peptide, C-peptide, substance P and D-Junk-inhibitor peptide, a full D-amino acid therapeutic peptide, were chosen. They were detected by ESI and simultaneous MS(1) and MS(2) acquisitions. With direct peptide infusion, MS(2) spectra revealed that fragmentation was peptide dependent, milder on the LIT-MS and required high collision energies on the TQ-MS to obtain high-intensity product ions. Peptide adsorption on surfaces was overcome and peptide dilutions ranging from 0.1 to 25 nM were injected onto an ultra high-pressure LC system with a 1 mm id analytical column and coupled with the MS instruments. No difference was observed between the two instruments when recording in LC-MS(1) acquisitions. However, in LC-MS(2) acquisitions, a better sensitivity in the detection of large peptides was observed with the LIT-MS. Indeed, with the three longer peptides, the typical fragmentation in the TQ-MS resulted in a dramatic loss of sensitivity (> or = 10x).
Resumo:
Goal: To validate oral vatgancictovir (VGC) in the prophylaxis of CMV infection in Lung (Lu) and Liver (L) recipients and in the treatment of CMV infection/disease in solid organ transplant recipients, using pharmacokinetic and pharmacodynamic studies in comparison with i/v gancicLovir (GCV). Methods: patients undergoing organ transpLantation donor or recipient CMV-seropositive receiving VGC prophylaxis for a period of 3 months (D+/R- Lung recipients, 6 months) were enroLLed. Heart (H), Lu, and L recipients received 900mg VGC q.d., adjusted to kidney (K) function. No K recipients received more than 450mg of VGC q.d. GCV trough (Ctrough) and peak (Cpeak = 3 hours after drug administration) LeveLs, and CMV DNA were measured at 7, 30, and 60 days post-transpLant (prophyLactic study). Patients who developed CMV infection/disease after stopping prophylaxis were treated with VGC (1800mg per day adjusted to K function and GCV blood LeveLs). GCV trough and peak LeveLs, and CMV DNA were measured weekly for the first 3 weeks and biweekly thereafter, until therapy cessation (therapeutic study). PLasma concentration of GCV is measured by HPLC. Results: In the first 8 prophyLaxed patients (6 K, and 1 L and 1 H transplant recipient) of 450mg VGC q.d., the average GCV concentration was 0.5±0.3 mg/t at trough, and 3.9±l.0mg/t 3 hours after administration. Inter-patient variability was substantiaL, especiaLLy for Ctrough (63% of total variance), which correlated with the patient's estimated gtomerutar filtration rate (r square = 42%). No CMV DNA was detected during VGC prophy- Laxis. Two patients (1 H and 1 L) were treated for Late CMV disease. Average GCV Cpeak were 8.9±2.3 mg/L and 4.6±0.5 rag/L, and GCV Ctrough were 2.0±0.9 mg/t and 1.6±0.2 mg/t respectively in each patient during induction phase. VGC treatment afforded a decrease in CMV DNA from 5.2 and 4.4 Log copies/10E6 cettutes at week 0, to 3.9 and 3.0 at week 1, and 3.3 and 2.1 at week 3, respectively.
Resumo:
Cancer immunotherapy has great promise, but is limited by diverse mechanisms used by tumors to prevent sustained antitumor immune responses. Tumors disrupt antigen presentation, T/NK-cell activation, and T/NK-cell homing through soluble and cell-surface mediators, the vasculature, and immunosuppressive cells such as myeloid-derived suppressor cells and regulatory T cells. However, many molecular mechanisms preventing the efficacy of antitumor immunity have been identified and can be disrupted by combination immunotherapy. Here, we examine immunosuppressive mechanisms exploited by tumors and provide insights into the therapies under development to overcome them, focusing on lymphocyte traffic.
Resumo:
Valganciclovir and ganciclovir are widely used for the prevention of cytomegalovirus (CMV) infection in solid organ transplant recipients, with a major impact on patients' morbidity and mortality. Oral valganciclovir, the ester prodrug of ganciclovir, has been developed to enhance the oral bioavailability of ganciclovir. It crosses the gastrointestinal barrier through peptide transporters and is then hydrolysed into ganciclovir. This review aims to describe the current knowledge of the pharmacokinetic and pharmacodynamic characteristics of this agent, and to address the issue of therapeutic drug monitoring. Based on currently available literature, ganciclovir pharmacokinetics in adult solid organ transplant recipients receiving oral valganciclovir are characterized by bioavailability of 66 +/- 10% (mean +/- SD), a maximum plasma concentration of 3.1 +/- 0.8 mg/L after a dose of 450 mg and of 6.6 +/- 1.9 mg/L after a dose of 900 mg, a time to reach the maximum plasma concentration of 3.0 +/- 1.0 hours, area under the plasma concentration-time curve values of 29.1 +/- 5.3 mg.h/L and 51.9 +/- 18.3 mg.h/L (after 450 mg and 900 mg, respectively), apparent clearance of 12.4 +/- 3.8 L/h, an elimination half-life of 5.3 +/- 1.5 hours and an apparent terminal volume of distribution of 101 +/- 36 L. The apparent clearance is highly correlated with renal function, hence the dosage needs to be adjusted in proportion to the glomerular filtration rate. Unexplained interpatient variability is limited (18% in apparent clearance and 28% in the apparent central volume of distribution). There is no indication of erratic or limited absorption in given subgroups of patients; however, this may be of concern in patients with severe malabsorption. The in vitro pharmacodynamics of ganciclovir reveal a mean concentration producing 50% inhibition (IC(50)) among CMV clinical strains of 0.7 mg/L (range 0.2-1.9 mg/L). Systemic exposure of ganciclovir appears to be moderately correlated with clinical antiviral activity and haematotoxicity during CMV prophylaxis in high-risk transplant recipients. Low ganciclovir plasma concentrations have been associated with treatment failure and high concentrations with haematotoxicity and neurotoxicity, but no formal therapeutic or toxic ranges have been validated. The pharmacokinetic parameters of ganciclovir after valganciclovir administration (bioavailability, apparent clearance and volume of distribution) are fairly predictable in adult transplant patients, with little interpatient variability beyond the effect of renal function and bodyweight. Thus ganciclovir exposure can probably be controlled with sufficient accuracy by thorough valganciclovir dosage adjustment according to patient characteristics. In addition, the therapeutic margin of ganciclovir is loosely defined. The usefulness of systematic therapeutic drug monitoring in adult transplant patients therefore appears questionable; however, studies are still needed to extend knowledge to particular subgroups of patients or dosage regimens.
Resumo:
Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 μm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (>200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m3).
Resumo:
We assessed the impact of antiviral prophylaxis and preemptive therapy on the incidence and outcomes of cytomegalovirus (CMV) disease in a nationwide prospective cohort of solid organ transplant recipients. Risk factors associated with CMV disease and graft failure-free survival were analyzed using Cox regression models. One thousand two hundred thirty-nine patients transplanted from May 2008 until March 2011 were included; 466 (38%) patients received CMV prophylaxis and 522 (42%) patients were managed preemptively. Overall incidence of CMV disease was 6.05% and was linked to CMV serostatus (D+/R- vs. R+, hazard ratio [HR] 5.36 [95% CI 3.14-9.14], pâeuro0/00<âeuro0/000.001). No difference in the incidence of CMV disease was observed in patients receiving antiviral prophylaxis as compared to the preemptive approach (HR 1.16 [95% CI 0.63-2.17], pâeuro0/00=âeuro0/000.63). CMV disease was not associated with a lower graft failure-free survival (HR 1.27 [95% CI 0.64-2.53], pâeuro0/00=âeuro0/000.50). Nevertheless, patients followed by the preemptive approach had an inferior graft failure-free survival after a median of 1.05 years of follow-up (HR 1.63 [95% CI 1.01-2.64], pâeuro0/00=âeuro0/000.044). The incidence of CMV disease in this cohort was low and not influenced by the preventive strategy used. However, patients on CMV prophylaxis were more likely to be free from graft failure.
Resumo:
The polycyclic aromatic hydrocarbon (PAH)-degrading strain Burkholderia sp. RP007 served as host strain for the design of a bacterial biosensor for the detection of phenanthrene. RP007 was transformed with a reporter plasmid containing a transcriptional fusion between the phnS putative promoter/operator region and the gene encoding the enhanced green fluorescent protein (GFP). The resulting bacterial biosensor--Burkholderia sp. strain RP037--produced significant amounts of GFP after batch incubation in the presence of phenanthrene crystals. Co-incubation with acetate did not disturb the phenanthrene-specific response but resulted in a homogenously responding population of cells. Active metabolism was required for induction with phenanthrene. The magnitude of GFP induction was influenced by physical parameters affecting the phenanthrene flux to the cells, such as the contact surface area between solid phenanthrene and the aqueous phase, addition of surfactant, and slow phenanthrene release from Model Polymer Release System beads or from a water-immiscible oil. These results strongly suggest that the bacterial biosensor can sense different phenanthrene fluxes while maintaining phenanthrene metabolism, thus acting as a genuine sensor for phenanthrene bioavailability. A relationship between GFP production and phenanthrene mass transfer is proposed.
Resumo:
BACKGROUND: The burden of enterococcal infections has increased over the last decades with vancomycin-resistant enterococci (VRE) being a major health problem. Solid organ transplantation is considered as a risk factor. However, little is known about the relevance of enterococci in solid organ transplantation recipients in areas with a low VRE prevalence. METHODS: We examined the epidemiology of enterococcal events in patients followed in the Swiss Transplant Cohort Study between May 2008 and September 2011 and analyzed risk factors for infection, aminopenicillin resistance, treatment, and outcome. RESULTS: Of the 1234 patients, 255 (20.7%) suffered from 392 enterococcal events (185 [47.2%] infections, 205 [52.3%] colonizations, and 2 events with missing clinical information). Only 2 isolates were VRE. The highest infection rates were found early after liver transplantation (0.24/person-year) consisting in 58.6% of Enterococcus faecium. The highest colonization rates were documented in lung transplant recipients (0.33/person-year), with 46.5% E. faecium. Age, prophylaxis with a betalactam antibiotic, and liver transplantation were significantly associated with infection. Previous antibiotic treatment, intensive care unit stay, and lung transplantation were associated with aminopenicillin resistance. Only 4/205 (2%) colonization events led to an infection. Adequate treatment did not affect microbiological clearance rates. Overall mortality was 8%; no deaths were attributable to enterococcal events. CONCLUSIONS: Enterococcal colonizations and infections are frequent in transplant recipients. Progression from colonization to infection is rare. Therefore, antibiotic treatment should be used restrictively in colonization. No increased mortality because of enterococcal infection was noted.
Resumo:
Late-onset cytomegalovirus (CMV) disease commonly occurs after discontinuation of antiviral prophylaxis. We determined the utility of testing CD8+ T-cell response against CMV as a predictor of late-onset CMV disease after a standard course of antiviral prophylaxis. Transplant patients at high-risk for CMV disease were enrolled. CD8+ T-cell-mediated immunity (CMI) was tested using the QuantiFERON-CMV assay at baseline, 1, 2 and 3 months posttransplant by measurement of interferon-gamma response to whole blood stimulation with a 21-peptide pool. The primary outcome was the ability of CMI testing to predict CMV disease in the first 6 months posttransplant. There were 108 evaluable patients (D+/R+ n = 39; D-/R+ n = 34; D+/R- n = 35) of whom 18 (16.7%) developed symptomatic CMV disease. At the end of prophylaxis, CMI was detectable in 38/108 (35.2%) patients (cutoff 0.1 IU/mL interferon-gamma). CMV disease occurred in 2/38 (5.3%) patients with a detectable interferon-gamma response versus 16/70 (22.9%) patients with a negative response; p = 0.038. In the subgroup of D+/R- patients, CMV disease occurred in 1/10 (10.0%) patients with a detectable interferon-gamma response (cutoff 0.1 IU/mL) versus 10/25 (40.0%) patients with a negative CMI, p = 0.12. Monitoring of CMI may be useful for predicting late-onset CMV disease.
Resumo:
Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).