208 resultados para policy diffusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The cerebellum is a complex structure that can be affected by several congenital and acquired diseases leading to alteration of its function and neuronal circuits. Identifying the structural bases of cerebellar neuronal networks in humans in vivo may provide biomarkers for diagnosis and management of cerebellar diseases. OBJECTIVES: To define the anatomy of intrinsic and extrinsic cerebellar circuits using high-angular resolution diffusion spectrum imaging (DSI). METHODS: We acquired high-resolution structural MRI and DSI of the cerebellum in four healthy female subjects at 3T. DSI tractography based on a streamline algorithm was performed to identify the circuits connecting the cerebellar cortex with the deep cerebellar nuclei, selected brainstem nuclei, and the thalamus. RESULTS: Using in-vivo DSI in humans we were able to demonstrate the structure of the following cerebellar neuronal circuits: (1) connections of the inferior olivary nucleus with the cerebellar cortex, and with the deep cerebellar nuclei (2) connections between the cerebellar cortex and the deep cerebellar nuclei, (3) connections of the deep cerebellar nuclei conveyed in the superior (SCP), middle (MCP) and inferior (ICP) cerebellar peduncles, (4) complex intersections of fibers in the SCP, MCP and ICP, and (5) connections between the deep cerebellar nuclei and the red nucleus and the thalamus. CONCLUSION: For the first time, we show that DSI tractography in humans in vivo is capable of revealing the structural bases of complex cerebellar networks. DSI thus appears to be a promising imaging method for characterizing anatomical disruptions that occur in cerebellar diseases, and for monitoring response to therapeutic interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Comprendre les principes physique de la diffusion. Comprendre le principe de mesure de la diffusion par IRM. Ccomprendre la relation entre la diffusion de l'eau en milieu biologique et l'organisation de la matière blanche. Comprendre comment cartographier la connectivité cérébrale par irm de diffusion. Messages à retenir: Les propriétés de diffusion du tissu cérébral sont conditionnées par l'architecture axonale. La mesure de la diffusion par IRM permet de cartographier les trajectoires de fibres nerveuses et donc la connectivité cérébrale. La connectivité cérébrale peut être mesurés de manière non-invasive. Résumé: La "connectomique" est un domaine émergeant et prometteur des neurosciences qui utilise l'IRM de diffusion en combinaison avec des traitements algorithmiques avancés afin de mesurer les trajectoires de faisceaux de fibres et la connectivité cérébrale permettant d'étudier l'organisation de la structure du réseau neuronal cérébral dans son ensemble. Lors de ce cours nous reverrons les méthodes rendant cette cartographie possible et exposerons les techniques d'analyse utilisées pour obtenir de nouvelles informations sur l'architecture cérébrale. Nous reverrons également un certains nombre d'exemple d'applications où la connectomique offre une nouvelle manière d'analyser et de comprendre le fonctionnement du cerveau normal ou malade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighted spin-echo imaging of the spine has been successfully implemented for differentiation of benign fracture edema and tumor infiltration of the vertebral body. Nevertheless, this technique still suffers from insufficient image quality in numerous patients due to motion artifacts. The aim of this study was to investigate the impact of variable respiratory motion artifact suppression techniques on image quality in diffusion-weighted spin-echo imaging of the spine. In addition to phase-encoding reordering, a newly implemented right hemi-diaphragmaitc navigator for respiratory gating was used. Subjective and objective image quality parameters were compared. Respiratory motion artifact suppression has a major impact on image quality in diffusion-weighted imaging of the spine. Phase-encoding reordering does not enhance image quality while right hemi-diaphragmatic respiratory navigator gating significantly improves image quality at the cost of data acquisition time. Navigator gating should be used if standard spin-echo diffusion-weighted imaging demonstrates insufficient image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

European regulatory networks (ERNs) constitute the main governance instrument for the informal co-ordination of public regulation at the European Union (EU) level. They are in charge of co-ordinating national regulators and ensuring the implementation of harmonized regulatory policies across the EU, while also offering sector-specific expertise to the Commission. To this aim, ERNs develop 'best practices' and benchmarking procedures in the form of standards, norms and guidelines to be adopted in member states. In this paper, we focus on the Committee of European Securities Regulators and examine the consequences of the policy-making structure of ERNs on the domestic adoption of standards. We find that the regulators of countries with larger financial industries tend to occupy more central positions in the network, especially among newer member states. In turn, network centrality is associated with a more prompt domestic adoption of standards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In February, 2005, the canton of Geneva in Switzerland prohibited the off-premise sale of alcoholic beverages between 9pm and 7am, and banned their sale in gas stations and video stores. The aim of this study is to assess the impact of this policy change on hospital admission rates for alcoholic intoxication.Methods: An interrupted time series analysis of this natural experiment was performed with data on hospitalisations for acute alcoholic intoxication during the 2002-2007 period. The canton of Geneva was treated as the experimental group, while all other Swiss cantons were used as the control group.Results: In the experimental site, the policy change was found to have a significant effect on admission rates among adolescents and young adults. Depending on the age group, hospitalisation rates for alcoholic intoxication fell by an estimated 25-40% as the result of restricted alcohol availability.Conclusions: Modest restrictions on opening hours and the density of off-premise outlets were found to be of relevance for public health in the canton of Geneva. In light of this finding, policy makers should consider such action as a promising approach to alcohol prevention. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Messages à retenir: Connaître le principe physique de l'imagerie de diffusion (DWI) à l'IRM adaptée à l'exploration des tumeurs du foie.Savoir la bonne technique d'acquisition des séquences pour évaluer la diffusion du parenchyme hépatique ainsi que des lésions focales intra -hépatiques les plusfréquentes.Apprendre l'utilité de la DWI pour évaluer le succès d'un traitement médical oncologique ou interventionnel .Discuter les avantages et les pièges liés à la DWI hépatique susceptibles d'influencer l'interprétation des tumeurs hépatiques. Résumé: Le principe d'imagerie de diffusion (DWI) à l'IRM repose sur la mobilité des molécules d'eau dans les différents tissus. Ce «mouvement Brownien» dépend de lacellularité tissulaire , des membranes cellulaires intactes et de la vascularisation . L'augmentation de ces paramètres précités résulte en une restriction de ladiffusion moléculaire, caractérisée par un hypersignal, puis quantifié par le calcul d'un coefficient apparent de diffusion (ADC). Basée sur des séquenceséchoplanaires pondérées en T2, la technique d'acquisition est rapide et non-invasive, donc souvent intégrée à l'IRM hépatique de routine. La DWI s'est révéléetrès sensible pour la détection de tumeurs hépatiques, même à un diamètre infracentimétrique. Néanmoins, sans être très spécifique, elle ne donne pas d'information certaine sur le caractère bénin ou malin, et elle doit être interprétée avec les autres séquences d'IRM et dans le contexte clinique donné. L'informationdiagnostique résultant de la DWI est morphologique et fonctionnelle, ce qui permet d'évaluer le succès de traitements oncologiques, notamment en absence dechangement de taille ou persistance de prise de contraste des lésions hépatiques. Très sensibles aux mouvements respiratoires, la DWI hépatique peut êtreaccompagnée d'artéfacts, qui influencent le calcul de l'ADC dont la valeur dépend de la machine IRM utilisée.