218 resultados para modern techniques
Resumo:
Due to advances in neonatal intensive care over the last decades, the pattern of brain injury seen in very preterm infants has evolved in more subtle lesions that are still essential to diagnose in regard to neurodevelopmental outcome. While cranial ultrasound is still used at the bedside, magnetic resonance imaging (MRI) is becoming increasingly used in this population for the assessment of brain maturation and white and grey matter lesions. Therefore, MRI provides a better prognostic value for the neurodevelopmental outcome of these preterms. Furthermore, the development of new MRI techniques, such as diffusion tensor imaging, resting state functional connectivity and magnetic resonance spectroscopy, may further increase the prognostic value, helping to counsel parents and allocate early intervention services.
Resumo:
Background Surgery of radiation-induced cataracts in children with retinoblastoma (RB) is a challenge as early intervention is weighted against the need to delay surgery until complete tumour control is obtained. This study analyses the safety and functional results of such surgery. Methods In a retrospective, non-comparative, consecutive case series, we reviewed medical records of RB patients </=14 y of age who underwent either external beam radiotherapy or plaque treatment and were operated for radiation-induced cataract between 1985 and 2008. Results In total, 21 eyes of 20 RB patients were included and 18 out of the 21 eyes had Reese-Ellsworth stage V or ABC classification group D/E RB. Median interval between last treatment for RB and cataract surgery was 21.5 months, range 3-164 months. Phacoaspiration was performed in 13 eyes (61%), extra-capsular cataract extraction in 8 (39%) and intraocular lens implantation in 19 eyes (90%). The majority of cases, 11/21 (52%), underwent posterior capsulorhexis or capsulotomy and 6/21 (28%) an anterior vitrectomy. Postoperative visual acuity was >/=20/200 in 13 eyes and <20/200 in 5 eyes. Intraocular tumour recurrence was noted in three eyes. Mean postoperative follow up was 90 months+/-69 months. Conclusions Modern cataract surgery, including clear cornea approach, lens aspiration with posterior capsulotomy, anterior vitrectomy and IOL implantation is a safe procedure for radiation-induced cataract as long as RB is controlled. The visual prognosis is limited by initial tumour involvement of the macula and by corneal complications of radiotherapy. We recommend a minimal interval of 9 months between completion of treatment of retinoblastoma and cataract surgery.
Resumo:
Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.
Resumo:
Context: The debate about the balance of risks and benefits of mammography screening has prompted a comprehensive review by an independent panel in the UK. However, the panel's remit did not cover the important economic dimension of breast cancer screening. Methods: The life histories of two cohort studies of 50-year-old women, who would be eligible within the National Health Service (NHS) breast screening programme (NHSBSP), were simulated over 35 years, using a life table approach. One cohort participant was offered screening at age 50 and triennially thereafter until age 70, assuming 75% attendance, while the other received no screening. Based on the findings from the panel's report, the cost-effectiveness of the NHSBSP was assessed for various scenarios of screening effect on breast cancer incidence (base case scenario: screening advances diagnosis by 5 years; 10% incidence reduction after screening stops).
Resumo:
As the morphological determination of living individuals of the two sibling species S. araneus and S. coronatus is not possible, we have tested two biochemical methods to determine these shrews in ecological studies. After producing specific antibodies by rabbits, we performed an immunological test on 25 individuals. With this first method, a correct determination was achieved in 76% of the cases only. The second method proved very successful: a polyacrylamide gel electrophoresis showed a systematic difference for albumin (73 individuals analyzed). According to our experience, the necessary blood sampling (10-20 μl) seems harmless for the shrews
Resumo:
PURPOSE: Since 1982, the Radiation Oncology Group of the EORTC (EORTC ROG) has pursued an extensive Quality Assurance (QA) program involving all centres actively participating in its clinical research. The first step is the evaluation of the structure and of the human, technical and organisational resources of the centres, to assess their ability to comply with the current requirements for high-tech radiotherapy (RT). MATERIALS AND METHODS: A facility questionnaire (FQ) was developed in 1989 and adapted over the years to match the evolution of RT techniques. We report on the contents of the current FQ that was completed online by 98 active EORTC ROG member institutions from 19 countries, between December 2005 and October 2007. RESULTS: Similar to the data collected previously, large variations in equipment, staffing and workload between centres remain. Currently only 15 centres still use a Cobalt unit. All centres perform 3D Conformal RT, 79% of them can perform IMRT and 54% are able to deliver stereotactic RT. An external reference dosimetry audit (ERDA) was performed in 88% of the centres for photons and in 73% for electrons, but it was recent (<2 years) in only 74% and 60%, respectively. CONCLUSION: The use of the FQ helps maintain the minimum quality requirements within the EORTC ROG network: recommendations are made on the basis of the analysis of its results. The present analysis shows that modern RT techniques are widely implemented in the clinic but also that ERDA should be performed more frequently. Repeated assessment using the FQ is warranted to document the future evolution of the EORTC ROG institutions.
Resumo:
Chest physiotherapy (CP) using passive expiratory manoeuvres is widely used in Western Europe for the treatment of bronchiolitis, despite lacking evidence for its efficacy. We undertook an open randomised trial to evaluate the effectiveness of CP in infants hospitalised for bronchiolitis by comparing the time to clinical stability, the daily improvement of a severity score and the occurrence of complications between patients with and without CP. Children <1 year admitted for bronchiolitis in a tertiary hospital during two consecutive respiratory syncytial virus seasons were randomised to group 1 with CP (prolonged slow expiratory technique, slow accelerated expiratory flow, rarely induced cough) or group 2 without CP. All children received standard care (rhinopharyngeal suctioning, minimal handling, oxygen for saturation ≥92%, fractionated meals). Ninety-nine eligible children (mean age, 3.9 months), 50 in group 1 and 49 in group 2, with similar baseline variables and clinical severity at admission. Time to clinical stability, assessed as primary outcome, was similar for both groups (2.9 ± 2.1 vs. 3.2 ± 2.8 days, P = 0.45). The rate of improvement of a clinical and respiratory score, defined as secondary outcome, only showed a slightly faster improvement of the respiratory score in the intervention group when including stethoacoustic properties (P = 0.044). Complications were rare but occurred more frequently, although not significantly (P = 0.21), in the control arm. In conclusion, this study shows the absence of effectiveness of CP using passive expiratory techniques in infants hospitalised for bronchiolitis. It seems justified to recommend against the routine use of CP in these patients.
Resumo:
BACKGROUND: Estimates of drug resistance incidence to modern first-line combination antiretroviral therapies against human immunodeficiency virus (HIV) type 1 are complicated by limited availability of genotypic drug resistance tests (GRTs) and uncertain timing of resistance emergence. METHODS: Five first-line combinations were studied (all paired with lamivudine or emtricitabine): efavirenz (EFV) plus zidovudine (AZT) (n = 524); EFV plus tenofovir (TDF) (n = 615); lopinavir (LPV) plus AZT (n = 573); LPV plus TDF (n = 301); and ritonavir-boosted atazanavir (ATZ/r) plus TDF (n = 250). Virological treatment outcomes were classified into 3 risk strata for emergence of resistance, based on whether undetectable HIV RNA levels were maintained during therapy and, if not, whether viral loads were >500 copies/mL during treatment. Probabilities for presence of resistance mutations were estimated from GRTs (n = 2876) according to risk stratum and therapy received at time of testing. On the basis of these data, events of resistance emergence were imputed for each individual and were assessed using survival analysis. Imputation was repeated 100 times, and results were summarized by median values (2.5th-97.5th percentile range). RESULTS: Six years after treatment initiation, EFV plus AZT showed the highest cumulative resistance incidence (16%) of all regimens (<11%). Confounder-adjusted Cox regression confirmed that first-line EFV plus AZT (reference) was associated with a higher median hazard for resistance emergence, compared with other treatments: EFV plus TDF (hazard ratio [HR], 0.57; range, 0.42-0.76), LPV plus AZT (HR, 0.63; range, 0.45-0.89), LPV plus TDF (HR, 0.55; range, 0.33-0.83), ATZ/r plus TDF (HR, 0.43; range, 0.17-0.83). Two-thirds of resistance events were associated with detectable HIV RNA level ≤500 copies/mL during treatment, and only one-third with virological failure (HIV RNA level, >500 copies/mL). CONCLUSIONS: The inclusion of TDF instead of AZT and ATZ/r was correlated with lower rates of resistance emergence, most likely because of improved tolerability and pharmacokinetics resulting from a once-daily dosage.
Resumo:
Echocardiography is the preferred initial test to assess cardiac morphology and ventricular function. Cardiac MRI enables an optimal visualisation of heart muscle without contrast injection, and precise measurement of the ventricular volumes and systolic function. It is therefore an ideal test for patients with poor echocardiographic windows or for the specific evaluation of right heart chambers. Heart CT also remarkably images heart muscle and precisely measures ventricular systolic function after intravenous injection of iodinated contrast. Coronary CT may also, in selected cases, avoid the need for diagnostic coronary angiography. Although very accurate, these imaging modalities are expensive and may be contra-indicated for a particular patient. Their use in clinical practice has to follow the accepted guidelines.
Resumo:
In European countries and North America, people spend 80 to 90% of time inside buildings and thus breathe indoor air. In Switzerland, special attention has been devoted to the 16 stations of the national network of observation of atmospheric pollutants (NABEL). The results indicate a reduction in outdoor pollution over the last ten years. With such a decrease in pollution over these ten years the question becomes: how can we explain an increase of diseases? Indoor pollution can be the cause. Indoor contaminants that may create indoor air quality (IAQ) problems come from a variety of sources. These can include inadequate ventilation, temperature and humidity dysfunction, and volatile organic compounds (VOCs). The health effects from these contaminants are varied and can range from discomfort, irritation and respiratory diseases to cancer. Among such contaminants, environmental tobacco smoke (ETS) could be considered the most important in terms of both health effects and engineering controls of ventilation. To perform indoor pollution monitoring, several selected ETS tracers can be used including carbon monoxide (CO), carbon dioxide (CO2), respirable particles (RSP), condensate, nicotine, polycyclic aromatic hydrocarbons (PAHs), nitrosamines, etc. In this paper, some examples are presented of IAQ problems that have occurred following the renewal of buildings and energy saving concerns. Using industrial hygiene sampling techniques and focussing on selected priority pollutants used as tracers, various problems have been identified and solutions proposed. [Author]
Resumo:
Percutaneous ablative procedures allow curative treatment of stage BCLC 0 or BCLC A hepatocellular carcinoma, as well as liver metastases of colorectal cancer. Several methods exist including radiofrequency ablation, the most commonly used. These techniques can be used in combination with surgical excision or alone if surgery is contraindicated. They are associated with significantly reduced mortality as compared to surgery.