99 resultados para limits of visual detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The demonstration by computed tomography of abnormalities related to asbestos is essential for the recognition of industrial disease, the compensation of which has considerable economic consequences. The use of compute tomography, the most reliable technique for the detection of pleuro-parenchymatous abnormalities related to asbestos exposure, has increased considerably in France since the publication of the results of a consensus conference in Paris in 1999. Since that time, developments in technology have noticeably modified the protocols of investigation and increased the sensitivity of the detection of pleural and interstitial parenchymatous abnormalities and of nodules. The technical recommendations and those for the interpretation of pleural and parenchymatous abnormalities need to be well known. They are presented in the form of an atlas that gives detailed criteria for asbestosis, pleural plaques and pleural fibrosis. The diagnosis of pleural plaques depends on the combination of clear limits at the pleural and pulmonary interface, typical topography and multiple, bilateral localization. In the context of asbestos exposure the plaques are characteristic of this exposure, unlike diffuse pleural thickening, crow's feet images, parenchymatous bands and entrapped atalectasis. The writing of the radiological report would be most appropriate on this basis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis at hand is concerned with the spatio-temporal brain mechanisms of visual food perception as investigated by electrical neuroimaging. Due to the increasing prevalence of obesity and its associated challenges for public health care, there is a need to better understand behavioral and brain processes underlying food perception and food-based decision-making. The first study (Study A) of this thesis was concerned with the role of repeated exposure to visual food cues. In our everyday lives we constantly and repeatedly encounter food and these exposures influence our food choices and preferences. In Study A, we therefore applied electrical neuroimaging analyses of visual evoked potentials to investigate the spatio-temporal brain dynamics linked to the repeated viewing of high- and low-energy food cues (published manuscript: "The role of energetic value in dynamic brain response adaptation during repeated food image viewing" (Lietti et al., 2012)). In this study, we found that repetitions differentially affect behavioral and brain mechanisms when high-energy, as opposed to low-energy foods and non-food control objects, were viewed. The representation of high-energy food remained invariant between initial and repeated exposures indicating that the sight of high-energy dense food induces less behavioral and neural adaptation than the sight of low-energy food and non-food control objects. We discuss this finding in the context of the higher salience (due to greater motivation and higher reward or hedonic valuation) of energy- dense food that likely generates a more mnemonically stable representation. In turn, this more invariant representation of energy-dense food is supposed to (partially) explain why these foods are over-consumed despite of detrimental health consequences. In Study Β we investigated food responsiveness in patients who had undergone Roux-en-Y gastric bypass surgery to overcome excessive obesity. This type of gastric bypass surgery is not only known to alter food appreciation, but also the secretion patterns of adipokines and gut peptides. Study Β aimed at a comprehensive and interdisciplinary investigation of differences along the gut-brain axis in bypass-operated patients as opposed to weight-matched non-operated controls. On the one hand, the spatio-temporal brain dynamics to the visual perception of high- vs. low-energy foods under differing states of motivation towards food intake (i.e. pre- and post-prandial) were assessed and compared between groups. On the other hand, peripheral gut hormone measures were taken in pre- and post-prandial nutrition state and compared between groups. In order to evaluate alterations in the responsiveness along the gut-brain-axis related to gastric bypass surgery, correlations between both measures were compared between both participant groups. The results revealed that Roux-en- Y gastric bypass surgery alters the spatio-temporal brain dynamics to the perception of high- and low-energy food cues, as well as the responsiveness along the gut-brain-axis. The potential role of these response alterations is discussed in relation to previously observed changes in physiological factors and food intake behavior post-Roux-en-Y gastric bypass surgery. By doing so, we highlight potential behavioral, neural and endocrine (i.e. gut hormone) targets for the future development of intervention strategies for deviant eating behavior and obesity. Together, the studies showed that the visual representation of foods in the brain is plastic and that modulations in neural activity are already noted at early stages of visual processing. Different factors of influence such as a repeated exposure, Roux-en-Y gastric bypass surgery, motivation (nutrition state), as well as the energy density of the visually perceived food were identified. En raison de la prévalence croissante de l'obésité et du défi que cela représente en matière de santé publique, une meilleure compréhension des processus comportementaux et cérébraux liés à la nourriture sont nécessaires. En particulier, cette thèse se concentre sur l'investigation des mécanismes cérébraux spatio-temporels liés à la perception visuelle de la nourriture. Nous sommes quotidiennement et répétitivement exposés à des images de nourriture. Ces expositions répétées influencent nos choix, ainsi que nos préférences alimentaires. La première étude (Study A) de cette thèse investigue donc l'impact de ces exposition répétée à des stimuli visuels de nourriture. En particulier, nous avons comparé la dynamique spatio-temporelle de l'activité cérébrale induite par une exposition répétée à des images de nourriture de haute densité et de basse densité énergétique. (Manuscrit publié: "The role of energetic value in dynamic brain response adaptation during repeated food image viewing" (Lietti et al., 2012)). Dans cette étude, nous avons pu constater qu'une exposition répétée à des images représentant de la nourriture de haute densité énergétique, par opposition à de la nourriture de basse densité énergétique, affecte les mécanismes comportementaux et cérébraux de manière différente. En particulier, la représentation neurale des images de nourriture de haute densité énergétique est similaire lors de l'exposition initiale que lors de l'exposition répétée. Ceci indique que la perception d'images de nourriture de haute densité énergétique induit des adaptations comportementales et neurales de moindre ampleur par rapport à la perception d'images de nourriture de basse densité énergétique ou à la perception d'une « catégorie contrôle » d'objets qui ne sont pas de la nourriture. Notre discussion est orientée sur les notions prépondérantes de récompense et de motivation qui sont associées à la nourriture de haute densité énergétique. Nous suggérons que la nourriture de haute densité énergétique génère une représentation mémorielle plus stable et que ce mécanisme pourrait (partiellement) être sous-jacent au fait que la nourriture de haute densité énergétique soit préférentiellement consommée. Dans la deuxième étude (Study Β) menée au cours de cette thèse, nous nous sommes intéressés aux mécanismes de perception de la nourriture chez des patients ayant subi un bypass gastrique Roux- en-Y, afin de réussir à perdre du poids et améliorer leur santé. Ce type de chirurgie est connu pour altérer la perception de la nourriture et le comportement alimentaire, mais également la sécrétion d'adipokines et de peptides gastriques. Dans une approche interdisciplinaire et globale, cette deuxième étude investigue donc les différences entre les patients opérés et des individus « contrôles » de poids similaire au niveau des interactions entre leur activité cérébrale et les mesures de leurs hormones gastriques. D'un côté, nous avons investigué la dynamique spatio-temporelle cérébrale de la perception visuelle de nourriture de haute et de basse densité énergétique dans deux états physiologiques différent (pre- et post-prandial). Et de l'autre, nous avons également investigué les mesures physiologiques des hormones gastriques. Ensuite, afin d'évaluer les altérations liées à l'intervention chirurgicale au niveau des interactions entre la réponse cérébrale et la sécrétion d'hormone, des corrélations entre ces deux mesures ont été comparées entre les deux groupes. Les résultats révèlent que l'intervention chirurgicale du bypass gastrique Roux-en-Y altère la dynamique spatio-temporelle de la perception visuelle de la nourriture de haute et de basse densité énergétique, ainsi que les interactions entre cette dernière et les mesures périphériques des hormones gastriques. Nous discutons le rôle potentiel de ces altérations en relation avec les modulations des facteurs physiologiques et les changements du comportement alimentaire préalablement déjà démontrés. De cette manière, nous identifions des cibles potentielles pour le développement de stratégies d'intervention future, au niveau comportemental, cérébral et endocrinien (hormones gastriques) en ce qui concerne les déviances du comportement alimentaire, dont l'obésité. Nos deux études réunies démontrent que la représentation visuelle de la nourriture dans le cerveau est plastique et que des modulations de l'activité neurale apparaissent déjà à un stade très précoce des mécanismes de perception visuelle. Différents facteurs d'influence comme une exposition repetee, le bypass gastrique Roux-en-Y, la motivation (état nutritionnel), ainsi que la densité énergétique de la nourriture qui est perçue ont pu être identifiés.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Previous literature suggests that early psychosis (EP) patients with a history of offending behavior (HOB) have specific clinical needs. The aims of this study were to assess: (1) the prevalence of HOB in a representative sample of EP; (2) the premorbid and baseline characteristics of patients with HOB, and (3) the potential differences in short-term outcome of such patients when compared to patients without HOB. METHODS: The Early Psychosis Prevention and Intervention Centre (EPPIC) admitted 786 EP patients between 1998 and 2000. Data were collected from patients' files using a standardized questionnaire. Data of 647 patients could be analyzed. RESULTS: HOB patients (29% of the sample) were more likely to be male with lower level of premorbid functioning and education, have used illicit substances and have attempted suicide. They presented with a more complex clinical picture and had poorer 18-month outcome. Most importantly, they had a significantly longer duration of untreated psychosis. CONCLUSIONS: On the basis of the high prevalence and specific features of EP patients with HOB, our study confirms a need for additional research in this domain and for the development of specific treatment strategies. Most importantly, it suggests a need for the promotion of early detection strategies among the populations of young offenders, considering that some of them may be going through the early phases of a psychotic disorder and that reduction of treatment delay and provision of well adapted interventions may have a significant impact at numerous levels in such patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The treatment of some cancer patients has shifted from traditional, non-specific cytotoxic chemotherapy to chronic treatment with molecular targeted therapies. Imatinib mesylate, a selective inhibitor of tyrosine kinases (TKIs) is the most prominent example of this new era and has opened the way to the development of several additional TKIs, including sunitinib, nilotinib, dasatinib, sorafenib and lapatinib, in the treatment of various hematological malignancies and solid tumors. All these agents are characterized by an important inter-individual pharmacokinetic variability, are at risk for drug interactions, and are not devoid of toxicity. Additionally, they are administered for prolonged periods, anticipating the careful monitoring of their plasma exposure via Therapeutic Drug Monitoring (TDM) to be an important component of patients' follow-up. We have developed a liquid chromatography-tandem mass spectrometry method (LC-MS/MS) requiring 100 microL of plasma for the simultaneous determination of the six major TKIs currently in use. Plasma is purified by protein precipitation and the supernatant is diluted in ammonium formate 20 mM (pH 4.0) 1:2. Reverse-phase chromatographic separation of TKIs is obtained using a gradient elution of 20 mM ammonium formate pH 2.2 and acetonitrile containing 1% formic acid, followed by rinsing and re-equilibration to the initial solvent composition up to 20 min. Analyte quantification, using matrix-matched calibration samples, is performed by electro-spray ionization-triple quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. The method was validated according to FDA recommendations, including assessment of extraction yield, matrix effects variability (<9.6%), overall process efficiency (87.1-104.2%), as well as TKIs short- and long-term stability in plasma. The method is precise (inter-day CV%: 1.3-9.4%), accurate (-9.2 to +9.9%) and sensitive (lower limits of quantification comprised between 1 and 10 ng/mL). This is the first broad-range LC-MS/MS assay covering the major currently in-use TKIs. It is an improvement over previous methods in terms of convenience (a single extraction procedure for six major TKIs, reducing significantly the analytical time), sensitivity, selectivity and throughput. It may contribute to filling the current knowledge gaps in the pharmacokinetics/pharmacodynamics relationships of the latest TKIs developed after imatinib and better define their therapeutic ranges in different patient populations in order to evaluate whether a systematic TDM-guided dose adjustment of these anticancer drugs could contribute to minimize the risk of major adverse reactions and to increase the probability of efficient, long lasting, therapeutic response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing number of bomb attacks involving improvised explosive devices, as well as the nature of the explosives, give rise to concern among safety and law enforcement agencies. The substances used in explosive charges are often everyday products diverted from their primary licit applications. Thus, reducing or limiting their accessibility for prevention purposes is difficult. Ammonium nitrate, employed in agriculture as a fertiliser, is used worldwide in small and large homemade bombs. Black powder, dedicated to hunting and shooting sports, is used illegally as a filling in pipe bombs causing extensive damage. If the main developments of instrumental techniques in explosive analysis have been constantly pushing the limits of detection, their actual contribution to the investigation of explosives in terms of source discrimination is limited. Forensic science has seen the emergence of a new technology, isotope ratio mass spectrometry (IRMS), that shows promising results. Its very first application in forensic science dates back to 1979. Liu et al. analysed cannabis plants coming from different countries [Liu et al. 1979]. This preliminary study highlighted its potential to discriminate specimens coming from different sources. Thirty years later, the keen interest in this new technology has given rise to a flourishing number of publications in forensic science. The countless applications of IRMS to a wide range of materials and substances attest to its success and suggest that the technique is ready to be used in forensic science. However, many studies are characterised by a lack of methodology and fundamental data. They have been undertaken in a top-down approach, applying this technique in an exploratory manner on a restricted sampling. This manner of procedure often does not allow the researcher to answer a number of questions, such as: do the specimens come from the same source, what do we mean by source or what is the inherent variability of a substance? The production of positive results has prevailed at the expense of forensic fundamentals. This research focused on the evaluation of the contribution of the information provided by isotopic analysis to the investigation of explosives. More specifically, this evaluation was based on a sampling of black powders and ammonium nitrate fertilisers coming from known sources. Not only has the methodology developed in this work enabled us to highlight crucial elements inherent to the methods themselves, but also to evaluate both the longitudinal and transversal variabilities of the information. First, the study of the variability of the profile over time was undertaken. Secondly, the variability of black powders and ammonium nitrate fertilisers within the same source and between different sources was evaluated. The contribution of this information to the investigation of explosives was then evaluated and discussed. --------------------------------------------------------------------------------------------------- Le nombre croissant d'attentats à la bombe impliquant des engins explosifs artisanaux, ainsi que la nature des charges explosives, constituent une préoccupation majeure pour les autorités d'application de la loi et les organismes de sécurité. Les substances utilisées dans les charges explosives sont souvent des produits du quotidien, détournés de leurs applications licites. Par conséquent, réduire ou limiter l'accessibilité de ces produits dans un but de prévention est difficile. Le nitrate d'ammonium, employé dans l'agriculture comme engrais, est utilisé dans des petits et grands engins explosifs artisanaux. La poudre noire, initialement dédiée à la chasse et au tir sportif, est fréquemment utilisée comme charge explosive dans les pipe bombs, qui causent des dommages importants. Si les développements des techniques d'analyse des explosifs n'ont cessé de repousser les limites de détection, leur contribution réelle à l'investigation des explosifs est limitée en termes de discrimination de sources. Une nouvelle technologie qui donne des résultats prometteurs a fait son apparition en science forensique: la spectrométrie de masse à rapport isotopique (IRMS). Sa première application en science forensique remonte à 1979. Liu et al. ont analysé des plants de cannabis provenant de différents pays [Liu et al. 1979]. Cette étude préliminaire, basée sur quelques analyses, a mis en évidence le potentiel de l'IRMS à discriminer des spécimens provenant de sources différentes. Trente ans plus tard, l'intérêt marqué pour cette nouvelle technologie en science forensique se traduit par un nombre florissant de publications. Les innombrables applications de l'IRMS à une large gamme de matériaux et de substances attestent de son succès et suggèrent que la technique est prête à être utilisée en science forensique. Cependant, de nombreuses études sont caractérisées par un manque de méthodologie et de données fondamentales. Elles ont été menées sans définir les hypothèses de recherche et en appliquant cette technique de façon exploratoire sur un échantillonnage restreint. Cette manière de procéder ne permet souvent pas au chercheur de répondre à un certain nombre de questions, tels que: est-ce que deux spécimens proviennent de la même source, qu'entend-on par source ou encore quelle est l'intravariabilité d'une substance? La production de résultats positifs a prévalu au détriment des fondamentaux de science forensique. Cette recherche s'est attachée à évaluer la contribution réelle de l'information isotopique dans les investigations en matière d'explosifs. Plus particulièrement, cette évaluation s'est basée sur un échantillonnage constitué de poudres noires et d'engrais à base de nitrate d'ammonium provenant de sources connues. La méthodologie développée dans ce travail a permis non seulement de mettre en évidence des éléments cruciaux relatifs à la méthode d'analyse elle-même, mais également d'évaluer la variabilité de l'information isotopique d'un point de vue longitudinal et transversal. Dans un premier temps, l'évolution du profil en fonction du temps a été étudiée. Dans un second temps, la variabilité du profil des poudres noires et des engrais à base de nitrate d'ammonium au sein d'une même source et entre différentes sources a été évaluée. La contribution de cette information dans le cadre des investigations d'explosifs a ensuite été discutée et évaluée.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is enormous interest in designing training methods for reducing cognitive decline in healthy older adults. Because it is impaired with aging, multitasking has often been targeted and has been shown to be malleable with appropriate training. Investigating the effects of cognitive training on functional brain activation might provide critical indication regarding the mechanisms that underlie those positive effects, as well as provide models for selecting appropriate training methods. The few studies that have looked at brain correlates of cognitive training indicate a variable pattern and location of brain changes - a result that might relate to differences in training formats. The goal of this study was to measure the neural substrates as a function of whether divided attentional training programs induced the use of alternative processes or whether it relied on repeated practice. Forty-eight older adults were randomly allocated to one of three training programs. In the SINGLE REPEATED training, participants practiced an alphanumeric equation and a visual detection task, each under focused attention. In the DIVIDED FIXED training, participants practiced combining verification and detection by divided attention, with equal attention allocated to both tasks. In the DIVIDED VARIABLE training, participants completed the task by divided attention, but were taught to vary the attentional priority allocated to each task. Brain activation was measured with fMRI pre- and post-training while completing each task individually and the two tasks combined. The three training programs resulted in markedly different brain changes. Practice on individual tasks in the SINGLE REPEATED training resulted in reduced brain activation whereas DIVIDED VARIABLE training resulted in a larger recruitment of the right superior and middle frontal gyrus, a region that has been involved in multitasking. The type of training is a critical factor in determining the pattern of brain activation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lymphocytic choriomeningitis virus (LCMV) is a rare cause of central nervous system disease in humans. Screening by real-time RT-PCR assay is of interest in the case of aseptic meningitis of unknown etiology. A specific LCMV real-time RT-PCR assay, based on the detection of genomic sequences of the viral nucleoprotein (NP), was developed to assess the presence of LCMV in cerebrospinal fluids (CSF) sent for viral screening to a Swiss university hospital laboratory. A 10-fold dilution series assay using a plasmid containing the cDNA of the viral NP of the LCMV isolate Armstrong (Arm) 53b demonstrated the high sensitivity of the assay with a lowest detection limit of ≤50 copies per reaction. High sensitivity was confirmed by dilution series assays in a pool of human CSF using four different LCMV isolates (Arm53b, WE54, Traub and E350) with observed detection limits of ≤10PFU/ml (Arm53b and WE54) and 1PFU/ml (Traub and E350). Analysis of 130 CSF showed no cases of acute infection. The absence of positive cases was confirmed by a published PCR assay detecting all Old World arenaviruses. This study validates a specific and sensitive real-time RT-PCR assay for the diagnosis of LCMV infections. Results showed that LCMV infections are extremely rare in hospitalized patients western in Switzerland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the diagnostic value and image quality of CT with filtered back projection (FBP) compared with adaptive statistical iterative reconstructed images (ASIR) in body stuffers with ingested cocaine-filled packets.Methods and Materials: Twenty-nine body stuffers (mean age 31.9 years, 3 women) suspected for ingestion of cocaine-filled packets underwent routine-dose 64-row multidetector CT with FBP (120kV, pitch 1.375, 100-300 mA and automatic tube current modulation (auto mA), rotation time 0.7sec, collimation 2.5mm), secondarily reconstructed with 30 % and 60 % ASIR. In 13 (44.83%) out of the body stuffers cocaine-filled packets were detected, confirmed by exact analysis of the faecal content including verification of the number (range 1-25). Three radiologists independently and blindly evaluated anonymous CT examinations (29 FBP-CT and 68 ASIR-CT) for the presence and number of cocaine-filled packets indicating observers' confidence, and graded them for diagnostic quality, image noise, and sharpness. Sensitivity, specificity, area under the receiver operating curve (ROC) Az and interobserver agreement between the 3 radiologists for FBP-CT and ASIR-CT were calculated.Results: The increase of the percentage of ASIR significantly diminished the objective image noise (p<0.001). Overall sensitivity and specificity for the detection of the cocaine-filled packets were 87.72% and 76.15%, respectively. The difference of ROC area Az between the different reconstruction techniques was significant (p= 0.0101), that is 0.938 for FBP-CT, 0.916 for 30 % ASIR-CT, and 0.894 for 60 % ASIR-CT.Conclusion: Despite the evident image noise reduction obtained by ASIR, the diagnostic value for detecting cocaine-filled packets decreases, depending on the applied ASIR percentage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The in situ deposition of zinc oxide on gold nanoparticles in aqueous solution has been here successfully applied in the field of fingermark detection on various non-porous surfaces. In this article, we present the improvement of the multimetal deposition, an existing technique limited up to now to non-luminescent results, by obtaining luminescent fingermarks with very good contrast and details. This is seen as a major improvement in the field in terms of selectivity and sensitivity of detection, especially on black surfaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since 2004, cannabis has been prohibited by the World Anti-Doping Agency for all sports competitions. In the years since then, about half of all positive doping cases in Switzerland have been related to cannabis consumption. In doping urine analysis, the target analyte is 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), the cutoff being 15 ng/mL. However, the wide urinary detection window of the long-term metabolite of Delta(9)-tetrahydrocannabinol (THC) does not allow a conclusion to be drawn regarding the time of consumption or the impact on the physical performance. The purpose of the present study on light cannabis smokers was to evaluate target analytes with shorter urinary excretion times. Twelve male volunteers smoked a cannabis cigarette standardized to 70 mg THC per cigarette. Plasma and urine were collected up to 8 h and 11 days, respectively. Total THC, 11-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH), and THC-COOH were determined after hydrolysis followed by solid-phase extraction and gas chromatography/mass spectrometry. The limits of quantitation were 0.1-1.0 ng/mL. Eight puffs delivered a mean THC dose of 45 mg. Plasma levels of total THC, THC-OH, and THC-COOH were measured in the ranges 0.2-59.1, 0.1-3.9, and 0.4-16.4 ng/mL, respectively. Peak concentrations were observed at 5, 5-20, and 20-180 min. Urine levels were measured in the ranges 0.1-1.3, 0.1-14.4, and 0.5-38.2 ng/mL, peaking at 2, 2, and 6-24 h, respectively. The times of the last detectable levels were 2-8, 6-96, and 48-120 h. Besides high to very high THC-COOH levels (245 +/- 1,111 ng/mL), THC (3 +/- 8 ng/mL) and THC-OH (51 +/- 246 ng/mL) were found in 65 and 98% of cannabis-positive athletes' urine samples, respectively. In conclusion, in addition to THC-COOH, the pharmacologically active THC and THC-OH should be used as target analytes for doping urine analysis. In the case of light cannabis use, this may allow the estimation of more recent consumption, probably influencing performance during competitions. However, it is not possible to discriminate the intention of cannabis use, i.e., for recreational or doping purposes. Additionally, pharmacokinetic data of female volunteers are needed to interpret cannabis-positive doping cases of female athletes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study is to determine whether statistical associations can be demonstrated in ocular syphilis between baseline clinical and laboratory parameters with visual acuity at presentation and with any change in visual acuity after treatment. METHODS: Charts of 26 patients (42 eyes) with ocular syphilis presenting to the Uveitis clinic of the Jules-Gonin Eye Hospital were reviewed. A baseline cross-sectional analysis was performed in order to identify any association between visual acuity at presentation and demographic, clinical or laboratory parameters. After treatment, any analogy between these parameters and a change in visual acuity was subsequently assessed in a series of univariate comparisons. RESULTS: The following factors were associated with worse initial visual acuity: severity of visual field impairment at presentation (p=0.012), macular oedema (p=0.004) and optic neuropathy (p=0.031). There was a borderline association with the presence of vasculitis on fluroangiography (p=0.072). Improvement in best corrected visual acuity after treatment was significantly associated with the presence of vasculitis on fluroangiography (p=0.005), neurosyphilis, according to lumbar puncture findings (p=0.037) and marginally with anterior uveitis (p=0.070). Inflammation relapse was associated with the coexistence of pain as presenting sign (p<0.001) and with a longer duration of symptoms prior to the initial visit (p=0.023). CONCLUSIONS: Severe ocular inflammation associated with vasculitis, vitritis or anterior uveitis in ocular syphilis would appear to be a reversible phenomenon that responds well to appropriate antibiotic treatment, resulting in improvement in visual acuity. Prompt treatment enables a good visual prognosis, while any delay in therapy increases the risk of subsequent relapse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A generic LC-MS approach for the absolute quantification of undigested peptides in plasma at mid-picomolar levels is described. Nine human peptides namely, brain natriuretic peptide (BNP), substance P (SubP), parathyroid hormone 1-34 (PTH), C-peptide, orexines A and B (Orex-A and -B), oxytocin (Oxy), gonadoliberin-1 (gonadothropin releasing-hormone or luteinizing hormone-releasing hormone, LHRH) and α-melanotropin (α-MSH) were targeted. Plasma samples were extracted via a 2-step procedure: protein precipitation using 1vol of acetonitrile followed by ultrafiltration of supernatants on membranes with a MW cut-off of 30 kDa. By applying a specific LC-MS setup, large volumes of filtrates (e.g., 2×750 μL) were injected and the peptides were trapped on a 1mm i.d.×10 mm length C8 column using a 10× on-line dilution. Then, the peptides were back-flushed and a second on-line dilution (2×) was applied during the transfer step. The refocalized peptides were resolved on a 0.3mm i.d. C18 analytical column. Extraction recovery, matrix effect and limits of detection were evaluated. Our comprehensive protocol demonstrates a simple and efficient sample preparation procedure followed by the analysis of peptides with limits of detection in the mid-picomolar range. This generic approach can be applied for the determination of most therapeutic peptides and possibly for endogenous peptides with latest state-of-the-art instruments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Traditionally, the ventral occipito-temporal (vOT) area, but not the superior parietal lobules (SPLs), is thought as belonging to the neural system of visual word recognition. However, some dyslexic children who exhibit a visual attention span disorder - i.e. poor multi-element parallel processing - further show reduced SPLs activation when engaged in visual multi-element categorization tasks. We investigated whether these parietal regions further contribute to letter-identity processing within strings. Adult skilled readers and dyslexic participants with a visual attention span disorder were administered a letter-string comparison task under fMRI. Dyslexic adults were less accurate than skilled readers to detect letter identity substitutions within strings. In skilled readers, letter identity differs related to enhanced activation of the left vOT. However, specific neural responses were further found in the superior and inferior parietal regions, including the SPLs bilaterally. Two brain regions that are specifically related to substituted letter detection, the left SPL and the left vOT, were less activated in dyslexic participants. These findings suggest that the left SPL, like the left vOT, may contribute to letter string processing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The processing of biological motion is a critical, everyday task performed with remarkable efficiency by human sensory systems. Interest in this ability has focused to a large extent on biological motion processing in the visual modality (see, for example, Cutting, J. E., Moore, C., & Morrison, R. (1988). Masking the motions of human gait. Perception and Psychophysics, 44(4), 339-347). In naturalistic settings, however, it is often the case that biological motion is defined by input to more than one sensory modality. For this reason, here in a series of experiments we investigate behavioural correlates of multisensory, in particular audiovisual, integration in the processing of biological motion cues. More specifically, using a new psychophysical paradigm we investigate the effect of suprathreshold auditory motion on perceptions of visually defined biological motion. Unlike data from previous studies investigating audiovisual integration in linear motion processing [Meyer, G. F. & Wuerger, S. M. (2001). Cross-modal integration of auditory and visual motion signals. Neuroreport, 12(11), 2557-2560; Wuerger, S. M., Hofbauer, M., & Meyer, G. F. (2003). The integration of auditory and motion signals at threshold. Perception and Psychophysics, 65(8), 1188-1196; Alais, D. & Burr, D. (2004). No direction-specific bimodal facilitation for audiovisual motion detection. Cognitive Brain Research, 19, 185-194], we report the existence of direction-selective effects: relative to control (stationary) auditory conditions, auditory motion in the same direction as the visually defined biological motion target increased its detectability, whereas auditory motion in the opposite direction had the inverse effect. Our data suggest these effects do not arise through general shifts in visuo-spatial attention, but instead are a consequence of motion-sensitive, direction-tuned integration mechanisms that are, if not unique to biological visual motion, at least not common to all types of visual motion. Based on these data and evidence from neurophysiological and neuroimaging studies we discuss the neural mechanisms likely to underlie this effect.