117 resultados para building usage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed.¦METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy.¦RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months.¦CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Addressing the risks of nanoparticles requires knowledge about their hazards, which is generated progressively, but also about occupational exposure and liberation into the environment. However, currently such information is not systematically collected, therefore the risk assessment of this exposure or liberation lacks quantitative data. In 2006 a targeted telephone survey among Swiss companies (1) showed the usage of nanoparticles in a few selected companies but did not provide data to extrapolate on the totality of the Swiss workforce. The goal of this study was to evaluate in a representative way the current prevalence and level of nanoparticle usage in Swiss industry, the health, safety and environment measures, and the number of potentially exposed workers. Results A representative, stratified mail survey was conducted among 1,626 clients of the Swiss National Accident Insurance Fund (SUVA). SUVA insures about 80,000 manufacturing firms, which represent 84% of all Swiss manufacturing companies. 947 companies answered the survey (58.3% response rate). Extrapolation to all Swiss manufacturing companies results in 1,309 workers (95%-confidence interval, 1,073 to 1,545) across the Swiss manufacturing sector being potentially exposed to nanoparticles in 586 companies (95%-CI: 145 to 1'027). This corresponds to 0.08% (95%-CI: 0.06% to 0.09%) of all Swiss manufacturing sector workers and to 0.6% (95%-CI: 0.2% to 1.1%) of companies. The industrial chemistry sector showed the highest percentage of companies using nanoparticles (21.2% of those surveyed) and a high percentage of potentially exposed workers (0.5% of workers in these companies), but many other important sectors also reported nanoparticles. Personal protection equipment was the predominant protection strategy. Only a minority applied specific environmental protection measures. Conclusions This is the first representative nationwide study on the prevalence of nanoparticle usage across a manufacturing sector. The information about the number of companies can be used for quantitative risk assessment. Furthermore it can help policy makers designing strategies to support companies in the responsible development of safer nanomaterial use. Noting the low prevalence of nanoparticle usage, there would still seem to be time to introduce necessary protection methods in a proactive and cost effective way in Swiss industry. But if the predicted "nano-revolution" becomes true, now is the time to take action.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed. METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy. RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months. CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hippocampal formation is essential for the processing of episodic memories for autobiographical events that happen in unique spatiotemporal contexts. Interestingly, before 2 years of age, children are unable to form or store episodic memories for recall later in life, a phenomenon known as infantile amnesia. From 2 to 7 years of age, there are fewer memories than predicted based on a forgetting function alone, a phenomenon known as childhood amnesia. Here, we discuss the postnatal maturation of the primate hippocampal formation with the goal of characterizing the development of the neurobiological substrates thought to subserve the emergence of episodic memory. Distinct regions, layers and cells of the hippocampal formation exhibit different profiles of structural and molecular development during early postnatal life. The protracted period of neuronal addition and maturation in the dentate gyrus is accompanied by the late maturation of specific layers in different hippocampal regions that are located downstream from the dentate gyrus, particularly CA3. In contrast, distinct layers in several hippocampal regions, particularly CA1, which receive direct projections from the entorhinal cortex, exhibit an early maturation. In addition, hippocampal regions that are more highly interconnected with subcortical structures, including the subiculum, presubiculum, parasubiculum and CA2, mature even earlier. These findings, together with our studies of the development of human spatial memory, support the hypothesis that the differential maturation of distinct hippocampal circuits might underlie the differential emergence of specific "hippocampus-dependent" memory processes, culminating in the emergence of episodic memory concomitant with the maturation of all hippocampal circuits.

Relevância:

20.00% 20.00%

Publicador: