87 resultados para automatic assessment tool


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An established tool for the assessment of motor performance in children with developmental coordination disorder (DCD) is the Movement-ABC-2 (M-ABC-2). The Zurich Neuromotor Assessment (ZNA) is also widely used for the evaluation of children's motor performance, but has not been compared with the M-ABC-2. Fifty-one children (39 males) between 5 and 7 years of age with suspected DCD were assessed using the M-ABC-2 and the ZNA. Rank correlations between scores of different test components were calculated. The structure of the tests was explored using canonical-correlation analysis. The correlation between total scores of the two motor tests was reasonable (0.66; p<0.001). However, ZNA scores were generally lower than those of M-ABC-2, due to poor performance in the fine motor adaptive component and increased contralateral associated movements (CAM). The canonical-correlation analysis revealed that ZNA measures components like pure motor skills and CAM that are not represented in the M-ABC-2. Furthermore, there was also no equivalent for the aiming and catching items of the M-ABC-2 in ZNA. The two tests measure different motor characteristics in children with suspected DCD and, thus, can be used complementary for the diagnosis of the disorder.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The objective was to explore whether a satellite-based navigation system, global positioning system used in differential mode (DGPS), could accurately assess the speed of running in humans. METHODS: A subject was equipped with a portable GPS receptor coupled to a receiver for differential corrections, while running outdoors on a straight asphalt road at 27 different speeds. Actual speed (reference method) was assessed by chronometry. RESULTS: The accuracy of speed prediction had a standard deviation (SD) of 0.08 km x h(-1) for walking, 0.11 km x h(-1) for running, yielding a coefficient of variation (SD/mean) of 1.38% and 0.82%, respectively. There was a highly significant linear relationship between actual and DGPS speed assessment (r2 = 0.999) with little bias in the prediction equation, because the slope of the regression line was close to unity (0.997). CONCLUSION: the DGPS technique appears to be a valid and inconspicuous tool for "on line" monitoring of the speed of displacement of individuals located on any field on earth, for prolonged periods of time and unlimited distance, but only in specific environmental conditions ("open sky"). Furthermore, the accuracy of speed assessment using the differential GPS mode was improved by a factor of 10 as compared to non-differential GPS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this research was to evaluate how fingerprint analysts would incorporate information from newly developed tools into their decision making processes. Specifically, we assessed effects using the following: (1) a quality tool to aid in the assessment of the clarity of the friction ridge details, (2) a statistical tool to provide likelihood ratios representing the strength of the corresponding features between compared fingerprints, and (3) consensus information from a group of trained fingerprint experts. The measured variables for the effect on examiner performance were the accuracy and reproducibility of the conclusions against the ground truth (including the impact on error rates) and the analyst accuracy and variation for feature selection and comparison.¦The results showed that participants using the consensus information from other fingerprint experts demonstrated more consistency and accuracy in minutiae selection. They also demonstrated higher accuracy, sensitivity, and specificity in the decisions reported. The quality tool also affected minutiae selection (which, in turn, had limited influence on the reported decisions); the statistical tool did not appear to influence the reported decisions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Control banding (CB) can be a useful tool for managing the potential risks of nanomaterials. The here proposed CB, which should be part of an overall risk control strategy, groups materials by hazard and emission potential. The resulting decision matrix proposes control bands adapted to the risk potential levels and helps define an action plan. If this plan is not practical and financially feasible, a full risk assessment is launched. The hazard banding combines key concepts of nanomaterial toxicology: translocation across biological barriers, fibrous nature, solubility, and reactivity. Already existing classifications specific to the nanomaterial can be used "as is." Otherwise, the toxicity of bulk or analogous substances gives an initial hazard band, which is increased if the substance is not easily soluble or if it has a higher reactivity than the substance. The emission potential bands are defined by the nanomaterials' physical form and process characteristics. Quantities, frequencies, and existing control measures are taken into account during the definition of the action plan. Control strategies range from room ventilation to full containment with expert advice. This CB approach, once validated, can be easily embedded in risk management systems. It allows integrating new toxicity data and needs no exposure data. [Authors]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the emergency situation, preoperative patient work-up for cardio-vascular surgery is quite different from the elective setting. We have analyzed a consecutive series of 5576 cases out of which 823 underwent emergency procedures (14.8%). The most frequent problems requiring emergent intervention were peripheral vascular (186 cases; 22.6% of the emergent procedure), followed by coronary artery disease (156 cases; 19.0%), thoracic aortic aneurysms (86 cases; 10.4%), abdominal aortic aneurysms (54 cases; 6.6%), congenital heart disease (36 cases: 4.4%), heart and heart lung transplantation (31 cases; 3.8%), problems with cardiac rythm (25 cases: 3.0%), and others (267 cases: 32.4%). Classification by proportion of urgent procedures with reference to elective operations shows a different picture. As a matter of fact transplantations were always emergency procedures (100%), whereas repair of aortic dissections type A and B was an emergency procedure in 81.5%. Emergency thoracic and abdominal aortic aneurysm repair accounted for 30% and 20% respectively and the corresponding proportion for peripheral vascular surgery is 19%. However, emergency surgery for acute coronary ischemia, valvular and congenital heart disease accounted for somewhat less than 10% for each group of these pathologies. Systematic pre-operative diagnostic work-up is a recognized tool for procedure related risk assessment and superior management of diseases. However, hemodynamic instability and other time related events correlated with negative outcome, are the main driving forces for accelerated diagnostic pathways

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Because early etiologic identification is critical to select appropriate specific status epilepticus (SE) management, we aim to validate a clinical tool we developed that uses history and readily available investigations to guide prompt etiologic assessment. METHODS: This prospective multicenter study included all adult patients treated for SE of all but anoxic causes from four academic centers. The proposed tool is designed as a checklist covering frequent precipitating factors for SE. The study team completed the checklist at the time the patient was identified by electroencephalography (EEG) request. Only information available in the emergency department or at the time of in-hospital SE identification was used. Concordance between the etiology indicated by the tool and the determined etiology at hospital discharge was analyzed, together with interrater agreement. RESULTS: Two hundred twelve patients were included. Concordance between the etiology hypothesis generated using the tool and the finally determined etiology was 88.7% (95% confidence interval (CI) 86.4-89.8) (κ = 0.88). Interrater agreement was 83.3% (95% CI 80.4-96) (κ = 0.81). SIGNIFICANCE: This tool is valid and reliable for identification early the etiology of an SE. Physicians managing patients in SE may benefit from using it to identify promptly the underlying etiology, thus facilitating selection of the appropriate treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Outcome following foot and ankle surgery can be assessed by disease- and region-specific scores. Many scoring systems exist, making comparison among studies difficult. The present study focused on outcome measures for a common foot and ankle abnormality and compared the results obtained by 2 disease-specific and 2 body region-specific scores. METHODS: We reviewed 41 patients who underwent lateral ankle ligament reconstruction. Four outcome scales were administered simultaneously: the Cumberland Ankle Instability Tool (CAIT) and the Chronic Ankle Instability Scale (CAIS), which are disease specific, and the American Orthopedic Foot & Ankle Society (AOFAS) hindfoot scale and the Foot and Ankle Ability Measure (FAAM), which are both body region-specific. The degree of correlation between scores was assessed by Pearson's correlation coefficient. Nonparametric tests, the Kruskal-Wallis and the Mann-Whitney test for pairwise comparison of the scores, were performed. RESULTS: A significant difference (P < .005) was observed between the CAIS and the AOFAS score (P = .0002), between the CAIS and the FAAM 1 (P = .0001), and between the CAIT and the AOFAS score (P = .0003). CONCLUSIONS: This study compared the performances of 4 disease- and body region-specific scoring systems. We demonstrated a correlation between the 4 administered scoring systems and notable differences between the results given by each of them. Disease-specific scores appeared more accurate than body region-specific scores. A strong correlation between the AOFAS score and the other scales was observed. The FAAM seemed a good compromise because it offered the possibility to evaluate the patient according to his or her own functional demand. CLINICAL RELEVANCE: The present study contributes to the development of more critical and accurate outcome assesment methods in foot and ankle surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Body accelerations during human walking were recorded by a portable measuring device. A new method for parameterizing body accelerations and finding the pattern of walking is outlined. Two neural networks were designed to recognize each pattern and estimate the speed and incline of walking. Six subjects performed treadmill walking followed by self-paced walking on an outdoor test circuit involving roads of various inclines. The neural networks were first "trained" by known patterns of treadmill walking. Then the inclines, the speeds, and the distance covered during overground walking (outdoor circuit) were estimated. The results show a good agreement between actual and predicted variables. The standard deviation of estimated incline was less than 2.6% and the maximum of the coefficient of variation of speed estimation is 6%. To the best of our knowledge, these results constitute the first assessment of speed, incline and distance covered during level and slope walking and offer investigators a new tool for assessing levels of outdoor physical activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper deals with the development and application of the generic methodology for automatic processing (mapping and classification) of environmental data. General Regression Neural Network (GRNN) is considered in detail and is proposed as an efficient tool to solve the problem of spatial data mapping (regression). The Probabilistic Neural Network (PNN) is considered as an automatic tool for spatial classifications. The automatic tuning of isotropic and anisotropic GRNN/PNN models using cross-validation procedure is presented. Results are compared with the k-Nearest-Neighbours (k-NN) interpolation algorithm using independent validation data set. Real case studies are based on decision-oriented mapping and classification of radioactively contaminated territories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Waist circumference (WC) is a key variable to assess in health management as it is a proxy of abdominal fat mass and a surrogate marker of cardiometabolic disease risk, including the metabolic syndrome. Recently, a portable non-contact device calculating WC (ViScan) has been developed, which hence allows the tracking of WC independently of the inter-investigators error. We compared WC values obtained with this device with WC measured by simple non-stretchable tape in 74 adults of varying body mass indices (range 17-39 kg/m(2)). The correlation between the two methods was very high (r=0.97, P<0.0001) and the reproducibility (precision) assessed with a rigid phantom was excellent (<1 cm, coefficient of variability<1%). The instrument constitutes a potentially valuable tool for longitudinal surveys and comparative international studies, which require simple but precise measurements of WC in order to track the effect of subtle changes on various health outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the past years, cardiovascular magnetic resonance (CMR) has proven its efficacy in large clinical trials, and consequently, the assessment of function, viability, and ischaemia by CMR is now an integrated part of the diagnostic armamentarium in cardiology. By combining these CMR applications, coronary artery disease (CAD) can be detected in its early stages and this allows for interventions with the goal to reduce complications of CAD such as infarcts and subsequently chronic heart failure (CHF). As the CMR examinations are robust and reproducible and do not expose patients to radiation, they are ideally suited for repetitive studies without harm to the patients. Since CAD is a chronic disease, the option to monitor CAD regularly by CMR over many decades is highly valuable. Cardiovascular magnetic resonance also progressed recently in the setting of acute coronary syndromes. In this situation, CMR allows for important differential diagnoses. Cardiovascular magnetic resonance also delineates precisely the different tissue components in acute myocardial infarction such as necrosis, microvascular obstruction (MVO), haemorrhage, and oedema, i.e. area at risk. With these features, CMR might also become the preferred tool to investigate novel treatment strategies in clinical research. Finally, in CHF patients, the versatility of CMR to assess function, flow, perfusion, and viability and to characterize tissue is helpful to narrow the differential diagnosis and to monitor treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Practicing physicians are faced with many medical decisions daily. These are mainly influenced by personal experience but should also consider patient preferences and the scientific evidence reflected by a constantly increasing number of medical publications and guidelines. With the objective of optimal medical treatment, the concept of evidence-based medicine is founded on these three aspects. It should be considered that there is a high risk of misinterpreting evidence, leading to medical errors and adverse effects without knowledge of the methodological background. OBJECTIVES: This article explains the concept of systematic error (bias) and its importance. Causes and effects as well as methods to minimize bias are discussed. This information should impart a deeper understanding, leading to a better assessment of studies and implementation of its recommendations in daily medical practice. CONCLUSION: Developed by the Cochrane Collaboration, the risk of bias (RoB) tool is an assessment instrument for the potential of bias in controlled trials. Good handling, short processing time, high transparency of judgements and a graphical presentation of findings that is easily comprehensible are among its strengths. Attached to this article the German translation of the RoB tool is published. This should facilitate the applicability for non-experts and moreover, support evidence-based medical decision-making.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The use of virtual reality (VR) has gained increasing interest to acquire laparoscopic skills outside the operating theatre and thus increasing patients' safety. The aim of this study was to evaluate trainees' acceptance of VR for assessment and training during a skills course and at their institution. METHODS: All 735 surgical trainees of the International Gastrointestinal Surgery Workshop 2006-2008, held in Davos, Switzerland, were given a minimum of 45 minutes for VR training during the course. Participants' opinion on VR was analyzed with a standardized questionnaire. RESULTS: Fivehundred-twenty-seven participants (72%) from 28 countries attended the VR sessions and answered the questionnaires. The possibility of using VR at the course was estimated as excellent or good in 68%, useful in 21%, reasonable in 9% and unsuitable or useless in 2%. If such VR simulators were available at their institution, most course participants would train at least one hour per week (46%), two or more hours (42%) and only 12% wouldn't use VR. Similarly, 63% of the participants would accept to operate on patients only after VR training and 55% to have VR as part of their assessment. CONCLUSION: Residents accept and appreciate VR simulation for surgical assessment and training. The majority of the trainees are motivated to regularly spend time for VR training if accessible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND : Status epilepticus (SE) treatment ranges from small benzodiazepine doses to coma induction. For some SE subgroups, it is unclear how the risk of an aggressive therapeutic approach balances with outcome improvement. We recently developed a prognostic score (Status Epilepticus Severity Score, STESS), relying on four outcome predictors (age, history of seizures, seizure type and extent of consciousness impairment), determined before treatment institution. Our aim was to assess whether the score might have a role in the treatment strategy choice. METHODS : This cohort study involved adult patients in three centers. For each patient, the STESS was calculated before primary outcome assessment: survival vs. death at discharge. Its ability to predict survival was estimated through the negative predictive value for mortality (NPV). Stratified odds ratios (OR) for mortality were calculated considering coma induction as exposure; strata were defined by the STESS level. RESULTS : In the observed 154 patients, the STESS had an excellent negative predictive value (0.97). A favorable STESS was highly related to survival (P < 0.001), and to return to baseline clinical condition in survivors (P < 0.001). The combined Mantel-Haenszel OR for mortality in patients stratified after coma induction and their STESS was 1.5 (95 % CI: 0.59-3.83). CONCLUSION : The STESS reliably identifies SE patients who will survive. Early aggressive treatment could not be routinely warranted in patients with a favorable STESS, who will almost certainly survive their SE episode. A randomized trial using this score would be needed to confirm this hypothesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The extended use of brentuximab-vedotin was reported for CD30(+) nonanaplastic peripheral T-cell lymphomas (PTCLs) with promising efficacy. CD30 status assessment is thus a critical factor for therapeutic decision, but the reliability of immunohistochemistry (IHC) in evaluating its expression remains to be defined. This prompted us to investigate the correlation between semiquantitative CD30 protein assessment by IHC and messenger RNA (mRNA) assessment by microarrays in a cohort of 376 noncutaneous PTCLs representative of the main entities. By IHC, CD30 expression was heterogeneous across and within entities and significantly associated with large tumor cell size. In addition to 100% anaplastic large-cell lymphomas, 57% of other PTCL entities were CD30-positive at a 5% threshold. CD30 protein expression was highly correlated to mRNA levels. mRNA levels were bimodal, separating high from low CD30-expressing PTCL cases. We conclude that IHC is a valuable tool in clinical practice to assess CD30 expression in PTCLs.