219 resultados para active pixel sensor
Resumo:
Interleukin-1beta (IL-1beta), reactive oxygen species (ROS), and thioredoxin-interacting protein (TXNIP) are all implicated in the pathogenesis of type 2 diabetes mellitus (T2DM). Here we review mechanisms directing IL-1beta production and its pathogenic role in islet dysfunction during chronic hyperglycemia. In doing so, we integrate previously disparate disease-driving mechanisms for IL-1beta, ROS, and TXNIP in T2DM into one unifying model in which the NLRP3 inflammasome plays a central role. The NLRP3 inflammasome also drives IL-1beta maturation and secretion in another disease of metabolic dysregulation, gout. Thus, we propose that the NLRP3 inflammasome contributes to the pathogenesis of T2DM and gout by functioning as a sensor for metabolic stress.
Resumo:
Background: CYP2D6 is the key enzyme responsible for tamoxifen bioactivation mainly into endoxifen. This gene is highly polymorphic and breast cancer patients classified as CYP2D6 poor metabolizers (PM) or intermediate metabolizers (IM) appear to show low concentrations of endoxifen and to achieve less benefit from tamoxifen treatment. Purpose: This prospective, open-label trial aimed to assess how the increase of tamoxifen dose influences the level of endoxifen in the different genotype groups (poor-, intermediate-, and extensive-metabolizers (EM)). We examined the impact of doubling tamoxifen dose to 20mg twice daily on endoxifen plasma concentrations across these genotype groups. Patients and methods: Patients were assayed for CYP2D6 genotype and phenotype using dextromethorphan test. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma levels were determined on 2 occasions at baseline (20mg/day of tamoxifen) and at day 30, 90 and 120 after dose increase (20 mg twice daily) using liquid chromatography-tandem-mass spectrometry. Endoxifen plasma levels were measured 6 to 24 hours after last drug intake to evaluate its accumulation before and after doubling tamoxifen dosage. ANOVA was used to evaluate endoxifen levels increase and difference between genotype groups. Results: 63 patients are available for analysis to date. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma reached steady state at 30 day after tamoxifen dose escalation, with a significant increase compared to baseline by 1.6 to 1.8 fold : geometric mean plasma concentrations (CV %) were 140 ng/mL (45%) at baseline vs 255 (47%) at day 30 for tamoxifen (P < 0.0001); 256 (49%) vs 408 (64%) for N-desmethyltamoxifen (P < 0.0001); 2.4 (46%) vs 3.9 (51%) for 4-OH-tamoxifen (P < 0.0001); and 20 (91%) vs 33 (91%) for endoxifen (P < 0.02). On baseline, endoxifen levels tended to be lower in PM: 7 ng/mL (36%), than IM: 16 ng/mL (70%), P=0.08, and EM: 24 ng/mL (71%), P<0.001. After doubling tamoxifen dosage, endoxifen concentrations rose similarly in PM, IM and EM with respectively, 1.5 (18%), 1.5 (28%) and 1.7 (30%) fold increase from baseline, P=0.18. Conclusion: Endoxifen exposure varies widely under standard tamoxifen dosage, with CYP2D6 genotype explaining only a minor part of this variability. It increases consistently on doubling tamoxifen dose, similarly across genotypes. This would enable exposure optimization based on concentration monitoring.
Resumo:
INTRODUCTION: The development of novel therapies and the increasing number of trials testing management strategies for luminal Crohn's disease (CD) have not filled all the gaps in our knowledge. Thus, in clinical practice, many decisions for CD patients need to be taken without high quality evidence. For this reason, a multidisciplinary European expert panel followed the RAND method to develop explicit criteria for the management of individual patients with active, steroid-dependent (ST-D) and steroid-refractory (ST-R) CD. AIMS & METHODS: Twelve international experts convened in Geneva, Switzerland in December 2007, to rate explicit clinical scenarios, corresponding to real daily practice, on a 9-point scale according to the literature evidence and their own expertise. Median ratings were stratified into three categories: appropriate (7-9), uncertain (4-6) and inappropriate (1-3). RESULTS: Overall, panelists rated 296 indications pertaining to mild-to-moderate, severe, ST-D, and ST-R CD. In anti-TNF naïve patients, budesonide and prednisone were found appropriate for mild-moderate CD, and infliximab (IFX) when those had previously failed or had not been tolerated. In patients with prior success with IFX, this drug with or without co-administration of a thiopurine analog was favored. Other anti-TNFs were appropriate in case of intolerance or resistance to IFX. High doses steroids, IFX or adalimumab were appropriate in severe active CD. Among 105 indications for ST-D or ST-R disease, the panel considered appropriate the thiopurine analogs, methotrexate, IFX, adalimumab and surgery for limited resection, depending on the outcome of prior therapies. Anti-TNFs were generally considered appropriate in ST-R. CONCLUSION: Steroids, including budesonide for mild-to-moderate CD, remain first-line therapies in active luminal CD. Anti-TNFs, in particular IFX with respect to the amount of available evidence, remain second-line for most indications. Thiopurine analogs are preferred to anti-TNFs when steroids are not appropriate, except when anti-TNFs were previously successful. These recommendations are available online (www.epact.ch). A prospective evaluation of these criteria in a large database in Switzerland in underway to validate these criteria.
Resumo:
In this paper, we propose a new paradigm to carry outthe registration task with a dense deformation fieldderived from the optical flow model and the activecontour method. The proposed framework merges differenttasks such as segmentation, regularization, incorporationof prior knowledge and registration into a singleframework. The active contour model is at the core of ourframework even if it is used in a different way than thestandard approaches. Indeed, active contours are awell-known technique for image segmentation. Thistechnique consists in finding the curve which minimizesan energy functional designed to be minimal when thecurve has reached the object contours. That way, we getaccurate and smooth segmentation results. So far, theactive contour model has been used to segment objectslying in images from boundary-based, region-based orshape-based information. Our registration technique willprofit of all these families of active contours todetermine a dense deformation field defined on the wholeimage. A well-suited application of our model is theatlas registration in medical imaging which consists inautomatically delineating anatomical structures. Wepresent results on 2D synthetic images to show theperformances of our non rigid deformation field based ona natural registration term. We also present registrationresults on real 3D medical data with a large spaceoccupying tumor substantially deforming surroundingstructures, which constitutes a high challenging problem.
Resumo:
BACKGROUND: Antinucleosome autoantibodies were previously described to be a marker of active lupus nephritis. However, the true prevalence of antinucleosome antibodies at the time of active proliferative lupus nephritis has not been well established. Therefore, the aim of this study is to define the prevalence and diagnostic value of autoantibodies against nucleosomes as a marker for active proliferative lupus nephritis. STUDY DESIGN: Prospective multicenter diagnostic test study. SETTING & PARTICIPANTS: 35 adult patients with systemic lupus erythematosus (SLE) at the time of the renal biopsy showing active class III or IV lupus nephritis compared with 59 control patients with SLE. INDEX TEST: Levels of antinucleosome antibodies and anti-double-stranded DNA (anti-dsDNA) antibodies. REFERENCE TEST: Kidney biopsy findings of class III or IV lupus nephritis at the time of sampling in a study population versus clinically inactive or no nephritis in a control population. RESULTS: Increased concentrations of antinucleosome antibodies were found in 31 of 35 patients (89%) with active proliferative lupus nephritis compared with 47 of 59 control patients (80%) with SLE. No significant difference between the 2 groups with regard to number of positive patients (P = 0.2) or antibody concentrations (P = 0.2) could be found. The area under the receiver operating characteristic curve as a marker of the accuracy of the test in discriminating between proliferative lupus nephritis and inactive/no nephritis in patients with SLE was 0.581 (95% confidence interval, 0.47 to 0.70; P = 0.2). Increased concentrations of anti-dsDNA antibodies were found in 33 of 35 patients (94.3%) with active proliferative lupus nephritis compared with 49 of 58 control patients (84.5%) with SLE (P = 0.2). In patients with proliferative lupus nephritis, significantly higher titers of anti-dsDNA antibodies were detected compared with control patients with SLE (P < 0.001). The area under the receiver operating characteristic curve in discriminating between proliferative lupus nephritis and inactive/no nephritis in patients with SLE was 0.710 (95% confidence interval, 0.60 to 0.82; P < 0.001). CONCLUSIONS: Antinucleosome antibodies have a high prevalence in patients with severe lupus nephritis. However, our data suggest that determining antinucleosome antibodies is of limited help in the distinction of patients with active proliferative lupus nephritis from patients with SLE without active renal disease.
Resumo:
The aim of this paper is to evaluate the risks associated with the use of fake fingerprints on a livescan supplied with a method of liveness detection. The method is based on optical properties of the skin. The sensor uses several polarizations and illuminations to capture the information of the different layers of the human skin. These experiments also allow for the determination under which conditions the system is deceived and if there is an influence respectively of the nature of the fake, the mould used for the production or the individuals involved in the attack. These experiments showed that current multispectral sensors can be deceived by the use of fake fingerprints created with or without the cooperation of the subject. Fakes created from direct casts perform better than those produced by fakes created from indirect casts. The results showed that the success of the attack is influenced by two main factors. The first is the quality of the fakes, and by extension the quality of the original fingerprint. The second is the combination of the general patterns involved in the attacks since an appropriate combination can strongly increase the rates of successful attacks.
Resumo:
BACKGROUND: Physicians need a specific risk-stratification tool to facilitate safe and cost-effective approaches to the management of patients with cancer and acute pulmonary embolism (PE). The objective of this study was to develop a simple risk score for predicting 30-day mortality in patients with PE and cancer by using measures readily obtained at the time of PE diagnosis. METHODS: Investigators randomly allocated 1,556 consecutive patients with cancer and acute PE from the international multicenter Registro Informatizado de la Enfermedad TromboEmbólica to derivation (67%) and internal validation (33%) samples. The external validation cohort for this study consisted of 261 patients with cancer and acute PE. Investigators compared 30-day all-cause mortality and nonfatal adverse medical outcomes across the derivation and two validation samples. RESULTS: In the derivation sample, multivariable analyses produced the risk score, which contained six variables: age > 80 years, heart rate ≥ 110/min, systolic BP < 100 mm Hg, body weight < 60 kg, recent immobility, and presence of metastases. In the internal validation cohort (n = 508), the 22.2% of patients (113 of 508) classified as low risk by the prognostic model had a 30-day mortality of 4.4% (95% CI, 0.6%-8.2%) compared with 29.9% (95% CI, 25.4%-34.4%) in the high-risk group. In the external validation cohort, the 18% of patients (47 of 261) classified as low risk by the prognostic model had a 30-day mortality of 0%, compared with 19.6% (95% CI, 14.3%-25.0%) in the high-risk group. CONCLUSIONS: The developed clinical prediction rule accurately identifies low-risk patients with cancer and acute PE.
Resumo:
Abstract Dynamics is a central aspect of ski jumping, particularly during take-off and stable flight. Currently, measurement systems able to measure ski jumping dynamics (e.g. 3D cameras, force plates) are complex and only available in few research centres worldwide. This study proposes a method to determine dynamics using a wearable inertial sensor-based system which can be used routinely on any ski jumping hill. The system automatically calculates characteristic dynamic parameters during take-off (position and velocity of the centre of mass perpendicular to the table, force acting on the centre of mass perpendicular to the table and somersault angular velocity) and stable flight (total aerodynamic force). Furthermore, the acceleration of the ski perpendicular to the table was quantified to characterise the skis lift at take-off. The system was tested with two groups of 11 athletes with different jump distances. The force acting on the centre of mass, acceleration of the ski perpendicular to the table, somersault angular velocity and total aerodynamic force were different between groups and correlated with the jump distances. Furthermore, all dynamic parameters were within the range of prior studies based on stationary measurement systems, except for the centre of mass mean force which was slightly lower.
Resumo:
The active fragment derived from factor XII (factor XIIf) was purified from human plasma and administered intravenously to normotensive conscious rats. Factor XIIf-mediated hypotension was dose-dependent and augmented by pretreatment with captopril, an inhibitor of the bradykinin-processing enzyme kininase II. These results therefore suggest that factor XIIf-mediated hypotension is due to the formation of bradykinin.
Resumo:
The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.
Resumo:
IMPLICATIONS: A new combined ear sensor was tested for accuracy in 20 critically ill children. It provides noninvasive and continuous monitoring of arterial oxygen saturation, arterial carbon dioxide tension, and pulse rate. The sensor proved to be clinically accurate in the tested range.
Resumo:
An active strain formulation for orthotropic constitutive laws arising in cardiac mechanics modeling is introduced and studied. The passive mechanical properties of the tissue are described by the Holzapfel-Ogden relation. In the active strain formulation, the Euler-Lagrange equations for minimizing the total energy are written in terms of active and passive deformation factors, where the active part is assumed to depend, at the cell level, on the electrodynamics and on the specific orientation of the cardiac cells. The well-posedness of the linear system derived from a generic Newton iteration of the original problem is analyzed and different mechanical activation functions are considered. In addition, the active strain formulation is compared with the classical active stress formulation from both numerical and modeling perspectives. Taylor-Hood and MINI finite elements are employed to discretize the mechanical problem. The results of several numerical experiments show that the proposed formulation is mathematically consistent and is able to represent the main key features of the phenomenon, while allowing savings in computational costs.
Resumo:
Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.