153 resultados para Ultrasonic technique
Resumo:
PURPOSE: To improve fat saturation in coronary MRA at 3T by using a spectrally selective adiabatic T2 -Prep (WSA-T2 -Prep). METHODS: A conventional adiabatic T2 -Prep (CA-T2 -Prep) was modified, such that the excitation and restoration pulses were of differing bandwidths. On-resonance spins are T2 -Prepared, whereas off-resonance spins, such as fat, are spoiled. This approach was combined with a CHEmically Selective Saturation (CHESS) pulse to achieve even greater fat suppression. Numerical simulations were followed by phantom validation and in vivo coronary MRA. RESULTS: Numerical simulations demonstrated that augmenting a CHESS pulse with a WSA-T2 -Prep improved robustness to B1 inhomogeneities and that this combined fat suppression was effective over a broader spectral range than that of a CHESS pulse in a conventional T2 -Prepared sequence. Phantom studies also demonstrated that the WSA-T2 -Prep+CHESS combination produced greater fat suppression across a range of B1 values than did a CA-T2 -Prep+CHESS combination. Lastly, in vivo measurements demonstrated that the contrast-to-noise ratio between blood and myocardium was not adversely affected by using a WSA-T2 -Prep, despite the improved abdominal and epicardial fat suppression. Additionally, vessel sharpness improved. CONCLUSION: The proposed WSA-T2 -Prep method was shown to improve fat suppression and vessel sharpness as compared to a CA-T2 -Prep technique, and to also increase fat suppression when combined with a CHESS pulse.
Resumo:
Intraoperative examination of sentinel axillary lymph nodes can be done by imprint cytology, frozen section, or, most recently, by PCR-based amplification of a cytokeratin signal. Using this technique, benign epithelial inclusions, representing mammary tissue displaced along the milk line, will likely generate a positive PCR signal and lead to a false-positive diagnosis of metastatic disease. To better appreciate the incidence of ectopic epithelial inclusions in axillary lymph nodes, we have performed an autopsy study, examining on 100 μm step sections 3,904 lymph nodes obtained from 160 axillary dissections in 80 patients. The median number of lymph nodes per axilla was 23 (15, 6, and 1 in levels 1, 2, and 3, respectively). A total of 30,450 hematoxylin-eosin stained slides were examined, as well as 8,825 slides immunostained with pan-cytokeratin antibodies. Despite this meticulous work-up, not a single epithelial inclusion was found in this study, suggesting that the incidence of such inclusions is much lower than the assumed 5% reported in the literature.
Resumo:
Following the introduction of single-metal deposition (SMD), a simplified fingermark detection technique based on multimetal deposition, optimization studies were conducted. The different parameters of the original formula were tested and the results were evaluated based on the contrast and overall aspect of the enhanced fingermarks. The new formula for SMD was found based on the most optimized parameters. Interestingly, it was found that important variations from the base parameters did not significantly affect the outcome of the enhancement, thus demonstrating that SMD is a very robust technique. Finally, a comparison of the optimized SMD with multi-metal deposition (MMD) was carried out on different surfaces. It was demonstrated that SMD produces comparable results to MMD, thus validating the technique.
Resumo:
BACKGROUND AND PURPOSE: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. MATERIAL AND METHODS: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. RESULTS: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. CONCLUSION: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological findings.
Resumo:
Totally extraperitoneal laparoscopic hernia repair is an efficient but technically demanding procedure. As mechanisms of hernia recurrence may be related to these technical difficulties, we have modified a previously described double-mesh technique in an effort to simplify the procedure. Extraperitoneal laparoscopic hernia repairs were performed in 82 male and 17 female patients having inguinal, femoral, and recurrent bilateral hernias. A standard propylene mesh measuring 15 x 15 cm was cut into two pieces of 4 x 15 cm and 11 x 15 cm. The smaller mesh was placed over both inguinal rings without splitting. The larger mesh was then inserted over the first mesh and stapled to low-risk zones, reinforcing the large-vessel area and the nerve transition zone. The mean procedure duration was 60 minutes for unilateral and 100 minutes for bilateral hernia repair. Patients were discharged from the hospital within 48 hours. The mean postoperative follow-up was 22 months, with no recurrences, neuralgia, or bleeding complications. Over a 2-year period, this technique was found to be satisfactory without recurrences or significant complications. In our hands, this technique was easier to perform: it allows for a less than perfect positioning of the meshes and avoids most of the stapling to crucial zones.
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.
Resumo:
L' évaluation quantitative des dangers et des expositions aux nanomatériaux se heurte à de nombreuses incertitudes qui ne seront levées qu'à mesure de la progression des connaissances scientifiques de leurs propriétés. L' une des conséquences de ces incertitudes est que les valeurs limites d'exposition professionnelle définies actuellement pour les poussières ne sont pas nécessairement pertinentes aux nanomatériaux. En l'absence de référentiel quantitatif et, à la demande de la DGS pour éclairer les réflexions de l' AFNOR et de l'ISO sur le sujet, une démarche de gestion graduée des risques (control banding) a été élaborée au sein de l' Anses. Ce développement a été réalisé à l'aide d'un groupe d'experts rapporteurs rattaché au Comité d'experts spécialisés évaluation des risques liés aux agents physiques, aux nouvelles technologies et aux grands aménagements. La mise en oeuvre de la démarche de gestion graduée des risques proposée repose sur quatre grandes étapes: 1. Le recueil des informations. Cette étape consiste à réunir les informations disponibles sur les dangers du nanomatériau manufacturé considéré ; ainsi que sur l'exposition potentielle des personnes aux postes de travail (observation sur le terrain, mesures, etc.). 2. L'attribution d'une bande de danger. Le danger potentiel du nanomatériau manufacturé présent, qu'il soit brut où incorporé dans une matrice (liquide ou solide) est évalué dans cette étape. La bande danger attribuée tient compte de la dangerosité du produit bulk ou de sa substance analogue à l'échelle non-nanométrique, de la bio-persistance du matériau (pour les matériaux fibreux), de sa solubilité et de son éventuelle réactivité. 3. Attribution d'une bande d'exposition. La bande d'exposition du nanomatériau manufacturé considéré ou du produit en contenant est définie par le niveau de potentiel d'émission du produit. Elle tient compte de sa forme physique (solide, liquide, poudre aérosol), de sa pulvérulence et de sa volatilité. Le nombre de travailleurs, la fréquence, la durée d'exposition ainsi que la quantité mise en oeuvre ne sont pas pris en compte, contrairement à une évaluation classique des risques chimiques. 4. Obtention d'une bande de maîtrise des risques. Le croisement des bandes de dangers et d'exposition préalablement attribuées permet de défi nir le niveau de maîtrise du risque. Il fait correspondre les moyens techniques et organisationnels à mettre en oeuvre pour maintenir le risque au niveau le plus faible possible. Un plan d'action est ensuite défi ni pour garantir l'effi cacité de la prévention recommandée par le niveau de maîtrise déterminé. Il tient compte des mesures de prévention déjà existantes et les renforce si nécessaire. Si les mesures indiquées par le niveau de maîtrise de risque ne sont pas réalisables, par exemple, pour des raisons techniques ou budgétaires, une évaluation de risque approfondie devra être réalisée par un expert. La gestion graduée des risques est une méthode alternative pour réaliser une évaluation qualitative de risques et mettre en place des moyens de prévention sans recourir à une évaluation quantitative des risques. Son utilisation semble particulièrement adaptée au contexte des nanomatériaux manufacturés, pour lequel les choix de valeurs de référence (Valeurs limites d'exposition en milieu professionnel) et des techniques de mesurage appropriées souffrent d'une grande incertitude. La démarche proposée repose sur des critères simples, accessibles dans la littérature scientifi que ou via les données techniques relatives aux produits utilisés. Pour autant, sa mise en oeuvre requiert des compétences minimales dans les domaines de la prévention des risques chimiques (chimie, toxicologie, etc.), des nanosciences et des nanotechnologies.
Resumo:
Cerebral blood flow can be studied in a multislice mode with a recently proposed perfusion sequence using inversion of water spins as an endogenous tracer without magnetization transfer artifacts. The magnetization transfer insensitive labeling technique (TILT) has been used for mapping blood flow changes at a microvascular level under motor activation in a multislice mode. In TILT, perfusion mapping is achieved by subtraction of a perfusion-sensitized image from a control image. Perfusion weighting is accomplished by proximal blood labeling using two 90 degrees radiofrequency excitation pulses. For control preparation the labeling pulses are modified such that they have no net effect on blood water magnetization. The percentage of blood flow change, as well as its spatial extent, has been studied in single and multislice modes with varying delays between labeling and imaging. The average perfusion signal change due to activation was 36.9 +/- 9.1% in the single-slice experiments and 38.1 +/- 7.9% in the multislice experiments. The volume of activated brain areas amounted to 1.51 +/- 0.95 cm3 in the contralateral primary motor (M1) area, 0.90 +/- 0.72 cc in the ipsilateral M1 area, 1.27 +/- 0.39 cm3 in the contralateral and 1.42 +/- 0.75 cm3 in the ipsilateral premotor areas, and 0.71 +/- 0.19 cm3 in the supplementary motor area.