181 resultados para Surgical Equipment
Resumo:
To date, state-of-the-art seismic material parameter estimates from multi-component sea-bed seismic data are based on the assumption that the sea-bed consists of a fully elastic half-space. In reality, however, the shallow sea-bed generally consists of soft, unconsolidated sediments that are characterized by strong to very strong seismic attenuation. To explore the potential implications, we apply a state-of-the-art elastic decomposition algorithm to synthetic data for a range of canonical sea-bed models consisting of a viscoelastic half-space of varying attenuation. We find that in the presence of strong seismic attenuation, as quantified by Q-values of 10 or less, significant errors arise in the conventional elastic estimation of seismic properties. Tests on synthetic data indicate that these errors can be largely avoided by accounting for the inherent attenuation of the seafloor when estimating the seismic parameters. This can be achieved by replacing the real-valued expressions for the elastic moduli in the governing equations in the parameter estimation by their complex-valued viscoelastic equivalents. The practical application of our parameter procedure yields realistic estimates of the elastic seismic material properties of the shallow sea-bed, while the corresponding Q-estimates seem to be biased towards too low values, particularly for S-waves. Given that the estimation of inelastic material parameters is notoriously difficult, particularly in the immediate vicinity of the sea-bed, this is expected to be of interest and importance for civil and ocean engineering purposes.
Resumo:
Reconstruction of important parameters such as femoral offset and torsion is inaccurate, when templating is based on plain x-rays. We evaluate intraoperative reproducibility of pre-operative CT-based 3D-templating in a consecutive series of 50 patients undergoing primary cementless THA through an anterior approach. Pre-operative planning was compared to a postoperative CT scan by image fusion. The implant size was correctly predicted in 100% of the stems, 94% of the cups and 88% of the heads (length). The difference between the planned and the postoperative leg length was 0.3 + 2.3 mm. Values for overall offset, femoral anteversion, cup inclination and anteversion were 1.4 mm ± 3.1, 0.6° ± 3.3°, -0.4° ± 5° and 6.9° ± 11.4°, respectively. This planning allows accurate implant size prediction. Stem position and cup inclination are accurately reproducible.
Resumo:
OBJECTIVES: Prevalence of abdominal aortic aneurysms (AAA) is not exactly known among patients with coronary artery disease (CAD) who are considered for surgical revascularisation. We evaluated the value of screening AAA among coronary patients admitted in our cardiovascular surgery unit. METHODS: Over a 24-month period, an abdominal echography was proposed to male patients aged 60 or more while hospitalised for surgical coronary revascularisation. Patients with previous investigation of the aorta were excluded. The aorta was considered aneurysmal when the anterior-posterior diameter was of 30 mm or more. RESULTS: Three hundred and ninety-five consecutive patients all accepted a proposed abdominal echographic screening for AAA. Forty unsuspected AAA were detected (10.1%). The mean diameter was 38.9 +/- 1.3 mm. Four AAA were larger than 50 mm and considered for surgery after the CABG procedure. Surveillance was proposed to the other 36, especially the 10 patients with an AAA larger than 40 mm. Patients with AAA were significantly older than those without AAA (71.3 +/- 0.8 vs. 69.4 +/- 0.3 years, P<0.05). Smoking history (P<0.05) and hypertension (P<0.05) were also associated more frequently with AAA. More than 16% of the patients being smokers and suffering hypertension presented with unsuspected AAA. CONCLUSIONS: In-hospital screening of AAA is very efficient among patients with coronary artery disease. Therefore, patients with CAD may be considered for routine AAA screening.
Resumo:
BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.
Resumo:
Introduction: Nonoperative treatment of displaced midshaft clavicle fractures is associated with higher nonunion rate than previously reported. Moreover, its occurrence can compromise shoulder function. The aim of this study was to evaluate the outcome of surgical treatment of symptomatic clavicle midshaft delayed and nonunion. Methods: Between 1999 and 2008, 19 clavicle delayed unions and nonunions were treated by open reduction and reconstructive plate fixation with augmentation by autologous bone graft. Iliac bone graft was used in 15 atrophic cases, and graft from the callus was used in 4 hypertrophic nonunions. There were 14 men and 5 women, with an average age of 41 years (range, 19 to 59 years) at time of surgery. No patient had undergone a previous surgery and all complained of shoulder pain. Delayed unions and nonunions were defined as non-healing after 3 and 6 months respectively. The mean time to surgery was 8 months (range, 4 to 23 months). All patients were pre and postoperatively clinically evaluated and imaged with standard radiographs until complete healing. Results: After a mean time of 3 months (range, 2 to 7 months) all fractures were completely healed. All patients reported full range of motion at time of last follow-up. Nine patients (47%) reported slight shoulder pain but all returned to their previous professional activities after a mean time of 3 months (range, 1 to 8 months). We reported 12 (63%) minor complications. There were 6 (32%) plate-related discomforts which resolved after hardware removal, two (11%) scar numbness, two (11%) adhesive capsulitis with spontaneous complete recovery, and two (11%) AC-joint pain treated successfully with local corticosteroids injection. Conclusion: Surgical treatment of delayed unions and nonunions of midshaft clavicle fractures yields satisfactory results and a high union rate. However, 50% of the patients may still complain of slight residual shoulder pain.
Resumo:
A 9-month-old girl presented with life-threatening acute respiratory failure 1 week after the surgical correction of a double aortic arch, which was due to a severe bulging of the pars membranacea into the lumen of the trachea that produced a complete obstruction of the lower trachea. Under cardiopulmonary bypass, a Y-shaped posterior biodegradable splint was placed behind the trachea and sutured to the posterior trachea, and a simultaneous right aortic arch aortopexy was performed. Thereafter, the child recovered normal respiratory function. Follow-up bronchoscopy showed a posterior dip at the splint level and an asymptomatic persistent posterior compression of the right main bronchus.
Resumo:
BACKGROUND: Multiple epiphyseal dysplasia (MED) is one of the more common generalised skeletal dysplasias. Due to its clinical heterogeneity diagnosis may be difficult. Mutations of at least six separate genes can cause MED. Joint deformities, joint pain and gait disorders are common symptoms. CASE PRESENTATION: We report on a 27-year-old male patient suffering from clinical symptoms of autosomal recessive MED with habitual dislocation of a multilayered patella on both sides, on the surgical treatment and on short-term clinical outcome. Clinical findings were: bilateral hip and knee pain, instability of femorotibial and patellofemoral joints with habitual patella dislocation on both sides, contractures of hip, elbow and second metacarpophalangeal joints. Main radiographic findings were: bilateral dislocated multilayered patella, dysplastic medial tibial plateaus, deformity of both femoral heads and osteoarthritis of the hip joints, and deformity of both radial heads. In the molecular genetic analysis, the DTDST mutation g.1984T > A (p.C653S) was found at the homozygote state. Carrier status was confirmed in the DNA of the patient's parents. The mutation could be considered to be the reason for the patient's disease. Surgical treatment of habitual patella dislocation with medialisation of the tibial tuberosity led to an excellent clinical outcome. CONCLUSIONS: The knowledge of different phenotypes of skeletal dysplasias helps to select genes for genetic analysis. Compared to other DTDST mutations, this is a rather mild phenotype. Molecular diagnosis is important for genetic counselling and for an accurate prognosis. Even in case of a multilayered patella in MED, habitual patella dislocation could be managed successfully by medialisation of the tibial tuberosity.
Resumo:
BACKGROUND: Closures of atrial septal defects or a patent foramen ovale (PFO) are increasingly performed percutaneously. The experience of late migration of a new bio-absorbable device is presented here, followed by conceptual discussion. METHODS: Six months post PFO closure with a BioSTAR® device a patient presented with chest pain. Echocardiography showed a hyperechogenic structure perforating the aortic wall. RESULTS: Surgical exploration showed a perforation of the ascending aorta by one metallic, non absorbable arm. This is the second case of late (>6 months) dislocation of the residual framework of the occluder. CONCLUSIONS: The overall incidence of perforation of cardiac structures due to secondary dislocation is low. However this complication exists and should kept in mind in symptomatic patients with new onset of chest pain, after percutaneous procedures. The concept of biodegradation, with residual, non absorbable metal braiding, should be reviewed, analyzing in particular long term results and incidence of secondary dislocation.
Resumo:
OBJECTIVES: To preliminarily evaluate prospectively the accuracy and reliability of a specific ad hoc reduction-compression forceps in intraoral open reduction of transverse and displaced mandibular angle fractures. STUDY DESIGN: We analyzed the clinical and radiologic data of 7 patients with 7 single transverse and displaced angle fractures. An intraoral approach was performed in all of the patients without using perioperative intermaxillary fixation. A single Arbeitsgemeinschaft Osteosynthese (AO) unilock reconstruction plate was fixed to each stable fragment with 3 locking screws (2.0 mm in 5 patients and 2.4 mm in 2 patients) at the basilar border of the mandible, according to AO/American Society of Internal Fixation (ASIF) principles. Follow-up was at 1, 3, 6, and 12 months, and we noted the status of healing and complications, if any. RESULTS: All of the patients had satisfactory fracture reduction as well as a successful treatment outcome without complications. CONCLUSION: This preliminary study demonstrated that the intraoral reduction of transverse and displaced angle fractures using a specific ad hoc reduction-forceps results in a high rate of success.
Resumo:
The aim of this work was to use the Urinary Distress Inventory (UDI-6) and Incontinence Impact Quality of Life (IIQ-7) questionnaires to compare 3 surgical techniques for stress urinary incontinence: the transvaginal tape (TVT) (105 women), the transobturator tape outside-in (TOT) (43 women), and the transvaginal tape-obturator inside-out (TVT-O) (54 women). There were no significant differences in frequent urination, urine leakage related to the feeling of urgency, urine leakage related to physical activity, or small amounts of urine leakage. TVT-operated women had a lower percentage of micturition difficulties compared with TOT women. TVT-O-operated women described slight discomfort in the genital area compared with the TVT technique, but this difference was not significant when compared with the TOT technique. When utilizing the UDI-6 and IIQ-7 scoring modifications before and after surgery, no difference among these 3 techniques is apparent.
Resumo:
BACKGROUND: Vascular reconstructions are becoming challenging due to the comorbidity of the aging population and since the introduction of minimally invasive approaches. Many sutureless anastomosis devices have been designed to facilitate the cardiovascular surgeon's work and the vascular join (VJ) is one of these. We designed an animal study to assess its reliability and long-term efficacy. METHODS: VJ allows the construction of end-to-end and end-to-side anastomoses. It consists of two metallic crowns fixed to the extremity of the two conduits so that vessel edges are joined layer by layer. There is no foreign material exposed to blood. In adult sheep both carotid arteries were prepared and severed. End-to-end anastomoses were performed using the VJ device on one side and the classical running suture technique on the other side. Animals were followed-up with Duplex-scan every 3 months and sacrificed after 12 months. Histopathological analysis was carried out. RESULTS: In 20 animals all 22 sutureless anastomoses were successfully completed in less than 2 min versus 6 +/- 3 min for running suture. Duplex showed the occlusion of three controls and one sutureless anastomosis. Two controls and one sutureless had stenosis >50%. Histology showed very thin layer of myointimal hyperplasia (50 +/- 10 microm) in the sutureless group versus 300 +/- 27 microm in the control. No significant inflammatory reaction was detected. CONCLUSIONS: VJ provides edge-to-edge vascular repair that can be considered the most physiological way to restore vessel continuity. For the first time, in healthy sheep, an anastomotic device provided better results than suture technique.
A pedicled bone graft from the acromion: an anatomical investigation regarding surgical feasibility.
Resumo:
OBJECTIVE: To investigate the technical feasibility of harvesting a vascularized bone graft from the acromion pedicled on the acromial branch. BACKGROUND: Complex fractures of the proximal humerus may result in partial or total avascular necrosis of the head fragment. Treatment of avascular necrosis of the humeral head is dependent upon the stage of disease as well as the dimension and location of necrosis. In general, the outcome is poor and complete restoration of the shoulder function is rarely attained. Contrary to osteonecrosis of carpal bones (where vascularized bone grafts have been routinely carried out for decades), reports of analogous procedures at the humeral head are anecdotal. METHODS: Based on selective post-mortem computer-tomographic angiography of 5 and the dissection of 30 embalmed human cadaver shoulders, we describe the anatomy of the acromial branch of the thoracoacromial trunk. The main focus was the constancy of its anatomical course, its dimensions and potential use as a nutrient vessel for a pedicled bone graft from the acromion. RESULTS: The course of the acromial branch revealed a constant topographic relationship to anatomical landmarks. Its terminal branches reliably supplied the anterior part of the acromion. The vascularized bone graft could be sufficiently mobilized to allow tension-free transfer to the humeral head as well as to the lateral two-thirds of the clavicle. CONCLUSION: We demonstrated the feasibility of vascularized bone graft harvesting from the acromion. This technique could be a joint-preserving procedure for osteonecrosis of the humeral head or may assist in the revision of a clavicular pseudoarthrosis.
Resumo:
PURPOSE: Spine surgery rates are increasing worldwide. Treatment failures are often attributed to poor patient selection and inappropriate treatment, but for many spinal disorders there is little consensus on the precise indications for surgery. With an aging population, more patients with lumbar degenerative spondylolisthesis (LDS) will present for surgery. The aim of this study was to develop criteria for the appropriateness of surgery in symptomatic LDS. METHODS: A systematic review was carried out to summarize the current level of evidence for the treatment of LDS. Clinical scenarios were generated comprising combinations of signs and symptoms in LDS and other relevant variables. Based on the systematic review and their own clinical experience, twelve multidisciplinary international experts rated each scenario on a 9-point scale (1 highly inappropriate, 9 highly appropriate) with respect to performing decompression only, fusion, and instrumented fusion. Surgery for each theoretical scenario was classified as appropriate, inappropriate, or uncertain based on the median ratings and disagreement in the ratings. RESULTS: 744 hypothetical scenarios were generated; overall, surgery (of some type) was rated appropriate in 27 %, uncertain in 41 % and inappropriate in 31 %. Frank panel disagreement was low (7 % scenarios). Face validity was shown by the logical relationship between each variable's subcategories and the appropriateness ratings, e.g., no/mild disability had a mean appropriateness rating of 2.3 ± 1.5, whereas the rating for moderate disability was 5.0 ± 1.6 and for severe disability, 6.6 ± 1.6. Similarly, the average rating for no/minimal neurological abnormality was 2.3 ± 1.5, increasing to 4.3 ± 2.4 for moderate and 5.9 ± 1.7 for severe abnormality. The three variables most likely (p < 0.0001) to be components of scenarios rated "appropriate" were: severe disability, no yellow flags, and severe neurological deficit. CONCLUSION: This is the first study to report criteria for determining candidacy for surgery in LDS developed by a multidisciplinary international panel using a validated method (RAM). The panel ratings followed logical clinical rationale, indicating good face validity. The work refines clinical classification and the phenotype of degenerative spondylolisthesis. The predictive validity of the criteria should be evaluated prospectively to examine whether patients treated "appropriately" have better clinical outcomes.