69 resultados para Superior mesenteric artery flow
Resumo:
Purpose: To work out certain, well-defined aetiologies frequently associated with mesenteric venous thrombosis (MVT) in order to predict a typical population at risk, since MVT is nowadays often incidentally detected on cross-sectional imaging. To demonstrate the MDCT features, frequency and extent of associated bowel ischemia according to the underlying pathology. Methods and materials: Our electronic database revealed 71 patients (25 women, mean age 55) with thrombosis of the superior and/or inferior mesenteric vein detected by MDCT between 2000 and 2008. Two radiologists jointly reviewed the corresponding MDCT features including intraluminal extension, underlying aetiology and associated bowel ischemia, if present. Results: MVT was associated with carcinoma in 31 (43.7%) patients (pancreas 21.1%, liver 9.9%, others 12.7%). Concomitant inflammation was seen in 15 (21.1%) patients (pancreatitis 11.3%, diverticulitis 4.2%, others 5.6%), whereas coagulation/hematologic disorders were found in 7 (9.9%) patients, liver cirrhosis in 6 (8.5%), mixed/miscellaneous causes in 5 (7%) and still unknown aetiologies in 5 patients (7%). MVT resulted from recent operations in 2 (2.8%) patients. MDCT features of venous bowel ischemia were present in 15 patients (21.1%). 46.5% of MVT were (sub) acute, while 53.5% chronic. The luminal extension was complete in 52.1%, subtotal (>50% of lumen) in 22.5% and partial (<50% of lumen) in 25.4% of patients, consisting either of blood clots (76.1%) or tumoral tissue (23.9%), the latter mainly due to pancreas adenocarcinoma (76.4%). Conclusion: MDCT features of MVT are seen with a wide range of underlying diseases. Signs of intestinal ischemia are infrequently associated, mostly occurring with coagulation/hematologic disorders (40%).
Resumo:
OBJECTIVES: The purpose of this study was to compare myocardial blood flow (MBF) and myocardial flow reserve (MFR) estimates from rubidium-82 positron emission tomography ((82)Rb PET) data using 10 software packages (SPs) based on 8 tracer kinetic models. BACKGROUND: It is unknown how MBF and MFR values from existing SPs agree for (82)Rb PET. METHODS: Rest and stress (82)Rb PET scans of 48 patients with suspected or known coronary artery disease were analyzed in 10 centers. Each center used 1 of 10 SPs to analyze global and regional MBF using the different kinetic models implemented. Values were considered to agree if they simultaneously had an intraclass correlation coefficient >0.75 and a difference <20% of the median across all programs. RESULTS: The most common model evaluated was the Ottawa Heart Institute 1-tissue compartment model (OHI-1-TCM). MBF values from 7 of 8 SPs implementing this model agreed best. Values from 2 other models (alternative 1-TCM and Axially distributed) also agreed well, with occasional differences. The MBF results from other models (e.g., 2-TCM and retention) were less in agreement with values from OHI-1-TCM. CONCLUSIONS: SPs using the most common kinetic model-OHI-1-TCM-provided consistent results in measuring global and regional MBF values, suggesting that they may be used interchangeably to process data acquired with a common imaging protocol.
Resumo:
BACKGROUND AND PURPOSE: Knowledge of cerebral blood flow (CBF) alterations in cases of acute stroke could be valuable in the early management of these cases. Among imaging techniques affording evaluation of cerebral perfusion, perfusion CT studies involve sequential acquisition of cerebral CT sections obtained in an axial mode during the IV administration of iodinated contrast material. They are thus very easy to perform in emergency settings. Perfusion CT values of CBF have proved to be accurate in animals, and perfusion CT affords plausible values in humans. The purpose of this study was to validate perfusion CT studies of CBF by comparison with the results provided by stable xenon CT, which have been reported to be accurate, and to evaluate acquisition and processing modalities of CT data, notably the possible deconvolution methods and the selection of the reference artery. METHODS: Twelve stable xenon CT and perfusion CT cerebral examinations were performed within an interval of a few minutes in patients with various cerebrovascular diseases. CBF maps were obtained from perfusion CT data by deconvolution using singular value decomposition and least mean square methods. The CBF were compared with the stable xenon CT results in multiple regions of interest through linear regression analysis and bilateral t tests for matched variables. RESULTS: Linear regression analysis showed good correlation between perfusion CT and stable xenon CT CBF values (singular value decomposition method: R(2) = 0.79, slope = 0.87; least mean square method: R(2) = 0.67, slope = 0.83). Bilateral t tests for matched variables did not identify a significant difference between the two imaging methods (P >.1). Both deconvolution methods were equivalent (P >.1). The choice of the reference artery is a major concern and has a strong influence on the final perfusion CT CBF map. CONCLUSION: Perfusion CT studies of CBF achieved with adequate acquisition parameters and processing lead to accurate and reliable results.
Resumo:
BACKGROUND AND PURPOSE: Unruptured anterior inferior cerebellar artery (AICA) aneurysms are rare but potentially lethal cerebellopontine angle (CPA) lesions that may be misdiagnosed as vestibular schwannomas when they present with vestibulo-cochlear symptoms. METHODS: We report two cases of unruptured but symptomatic AICA aneurysms initially referred to us as atypical vestibular schwannomas requiring surgery. Two discriminant MR features are described. RESULTS: One patient refused treatment. The other was successfully treated by coil occlusion. CONCLUSIONS: Caution is advised before suspecting a CPA mass to be a purely extra-canalicular schwannoma, given its extreme rarity. Deafness and cerebellar ischemia may be prevented if AICA aneurysms are correctly identified preoperatively. In the absence of specific arterial imaging, two MR features may distinguish them from vestibular schwannomas: (1) the absence of internal auditory canal enlargement and (2) the "blurry dot sign," representing blood flow artefacts on pre- and postcontrast studies.
Resumo:
OBJECTIVES: The role of angioplasty/stenting procedures, neurointerventionist experience, vascular risk factors, medical treatment and blood flow velocities were analysed to identify possible causes of intra-stent restenosis (ISR) following stenting of cervical and/or intracranial arteries, assuming progressive atherosclerosis to be the shared mechanism in both territories. Patients. 26 cerebrovascular patients subjected to stenting of severe (≥85%) symptomatic or asymptomatic carotid stenoses or moderate-to-severe (≥50%) intracranial or vertebral stenoses were included. METHODS: Clinical, radiological and ultrasonographic follow-up data were analysed retrospectively. RESULTS: Overall, stenting of the internal carotid artery (ICA) induced significant reductions in peak systolic velocities at 2 years (96±31cm/s vs. 358.2±24.9cm/s at baseline). The procedure-related ischemic complications rate was 7.4% (one hemispheric stroke and one TIA). The rate of ISR≤50% was 8% in the ICA at 2 years; was 50% in the common carotid artery (CCA) at 1 year, with concomitant distal ICA stenosis in 75% of CCA stenting, but all ISR were asymptomatic. Patients with ISR of the ICA were significantly younger (56.8±4.5 vs. 71.3±3.6 years, P=0.042) and had significantly more risk factors (5.5±0.9 vs. 3±0.3, P=0.012). No ISR≥70% was detected. CONCLUSIONS: ISR is relatively infrequent and, when present, it is mild and asymptomatic. Restenosis is more frequent in younger patients and those with several risk factors, and it may also be related to stenting of previous carotid endarterectomy.
Resumo:
Hypoxia increases the ventilatory response to exercise, which leads to hyperventilation-induced hypocapnia and subsequent reduction in cerebral blood flow (CBF). We studied the effects of adding CO2 to a hypoxic inspired gas on CBF during heavy exercise in an altitude naïve population. We hypothesized that augmented inspired CO2 and hypoxia would exert synergistic effects on increasing CBF during exercise, which would improve exercise capacity compared to hypocapnic hypoxia. We also examined the responsiveness of CO2 and O2 chemoreception on the regulation ventilation (E) during incremental exercise. We measured middle cerebral artery velocity (MCAv; index of CBF), E, end-tidal PCO2, respiratory compensation threshold (RC) and ventilatory response to exercise (E slope) in ten healthy men during incremental cycling to exhaustion in normoxia and hypoxia (FIO2 = 0.10) with and without augmenting the fraction of inspired CO2 (FICO2). During exercise in normoxia, augmenting FICO2 elevated MCAv throughout exercise and lowered both RC onset andE slope below RC (P<0.05). In hypoxia, MCAv and E slope below RC during exercise were elevated, while the onset of RC occurred at lower exercise intensity (P<0.05). Augmenting FICO2 in hypoxia increased E at RC (P<0.05) but no difference was observed in RC onset, MCAv, or E slope below RC (P>0.05). The E slope above RC was unchanged with either hypoxia or augmented FICO2 (P>0.05). We found augmenting FICO2 increased CBF during sub-maximal exercise in normoxia, but not in hypoxia, indicating that the 'normal' cerebrovascular response to hypercapnia is blunted during exercise in hypoxia, possibly due to an exhaustion of cerebral vasodilatory reserve. This finding may explain the lack of improvement of exercise capacity in hypoxia with augmented CO2. Our data further indicate that, during exercise below RC, chemoreception is responsive, while above RC the ventilatory response to CO2 is blunted.
Resumo:
BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS: We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS: CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION: CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.
Resumo:
BACKGROUND: The mechanism behind early graft failure after right ventricular outflow tract (RVOT) reconstruction is not fully understood. Our aim was to establish a three-dimensional computational fluid dynamics (CFD) model of RVOT to investigate the hemodynamic conditions that may trigger the development of intimal hyperplasia and arteriosclerosis. METHODS: Pressure, flow, and diameter at the RVOT, pulmonary artery (PA), bifurcation of the PA, and left and right PAs were measured in 10 normal pigs with a mean weight of 24.8 ± 0.78 kg. Data obtained from the experimental scenario were used for CFD simulation of pressure, flow, and shear stress profile from the RVOT to the left and right PAs. RESULTS: Using experimental data, a CFD model was obtained for 2.0 and 2.5-L/min pulsatile inflow profiles. In both velocity profiles, time and space averaged in the low-shear stress profile range from 0-6.0 Pa at the pulmonary trunk, its bifurcation, and at the openings of both PAs. These low-shear stress areas were accompanied to high-pressure regions 14.0-20.0 mm Hg (1866.2-2666 Pa). Flow analysis revealed a turbulent flow at the PA bifurcation and ostia of both PAs. CONCLUSIONS: Identified local low-shear stress, high pressure, and turbulent flow correspond to a well-defined trigger pattern for the development of intimal hyperplasia and arteriosclerosis. As such, this real-time three-dimensional CFD model may in the future serve as a tool for the planning of RVOT reconstruction, its analysis, and prediction of outcome.