120 resultados para Stiffness reduction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Increasingly, patients receiving methadone treatment are found in low threshold facilities (LTF), which provide needle exchange programmes in Switzerland. This paper identifies the characteristics of LTF attendees receiving methadone treatment (MT) compared with other LTF attendees (non-MT). METHODS: A national cross-sectional survey was conducted in 2006 over five consecutive days in all LTF (n=25). Attendees were given an anonymous questionnaire, collecting information on socio-demographic indicators, drug consumption, injection, methadone treatment, and self-reported HIV and HCV status. Univariate analysis and logistic regression were performed to compare MT to non-MT. The response rate was 66% (n=1128). RESULTS: MT comprised 57.6% of the sample. In multivariate analysis, factors associated with being on MT were older age (OR: 1.38), being female (OR: 1.60), having one's own accommodation (OR: 1.56), receiving public assistance (OR: 2.29), lifetime injecting (OR: 2.26), HIV-positive status (OR: 2.00), and having consumed cocaine during the past month (OR: 1.37); MT were less likely to have consumed heroin in the past month (OR: 0.76, not significant) and visited LTF less often on a daily basis (OR: 0.59). The number of injections during the past week was not associated with MT. CONCLUSIONS: More LTF attendees were in the MT group, bringing to light an underappreciated LTF clientele with specific needs. The MT group consumption profile may reflect therapeutic failure or deficits in treatment quality and it is necessary to acknowledge this and to strengthen the awareness of LTF personnel about potential needs of MT attendees to meet their therapeutic goals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: New evidence shows that high density lipoproteins (HDL) have protective effects beyond their role in reverse cholesterol transport. Reconstituted HDL (rHDL) offer an attractive means of clinically exploiting these novel effects including cardioprotection against ischemia reperfusion injury (IRI). However, basic rHDL composition is limited to apolipoprotein AI (apoAI) and phospholipids; addition of bioactive compound may enhance its beneficial effects. OBJECTIVE: The aim of this study was to investigate the role of rHDL in post-ischemic model, and to analyze the potential impact of sphingosine-1-phosphate (S1P) in rHDL formulations. METHODS AND RESULTS: The impact of HDL on IRI was investigated using complementary in vivo, ex vivo and in vitro IRI models. Acute post-ischemic treatment with native HDL significantly reduced infarct size and cell death in the ex vivo, isolated heart (Langendorff) model and the in vivo model (-48%, p<0.01). Treatment with rHDL of basic formulation (apoAI + phospholipids) had a non-significant impact on cell death in vitro and on the infarct size ex vivo and in vivo. In contrast, rHDL containing S1P had a highly significant, protective influence ex vivo, and in vivo (-50%, p<0.01). This impact was comparable with the effects observed with native HDL. Pro-survival signaling proteins, Akt, STAT3 and ERK1/2 were similarly activated by HDL and rHDL containing S1P both in vitro (isolated cardiomyocytes) and in vivo. CONCLUSION: HDL afford protection against IRI in a clinically relevant model (post-ischemia). rHDL is significantly protective if supplemented with S1P. The protective impact of HDL appears to target directly the cardiomyocyte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the characteristics of micro-organisms in clinical specimens is essential for the rapid diagnosis and treatment of infections. A thorough investigation of the nanoscale properties of bacteria can prove to be a fundamental tool. Indeed, in the latest years, the importance of high resolution analysis of the properties of microbial cell surfaces has been increasingly recognized. Among the techniques available to observe at high resolution specific properties of microscopic samples, the Atomic Force Microscope (AFM) is the most widely used instrument capable to perform morphological and mechanical characterizations of living biological systems. Indeed, AFM can routinely study single cells in physiological conditions and can determine their mechanical properties with a nanometric resolution. Such analyses, coupled with high resolution investigation of their morphological properties, are increasingly used to characterize the state of single cells. In this work, we exploit the capabilities and peculiarities of AFM to analyze the mechanical properties of Escherichia coli in order to evidence with a high spatial resolution the mechanical properties of its structure. In particular, we will show that the bacterial membrane is not mechanically uniform, but contains stiffer areas. The force volume investigations presented in this work evidence for the first time the presence and dynamics of such structures. Such information is also coupled with a novel stiffness tomography technique, suggesting the presence of stiffer structures present underneath the membrane layer that could be associated with bacterial nucleoids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The elbow joint is vulnerable to stiffness, especially after trauma. The aim of this study was to evaluate the results of open arthrolysis for posttraumatic elbow stiffness. DESIGN: Cohort retrospective study. PATIENTS: Eighteen consecutive patients were evaluated by an independent observer at an average of 16 months (6 to 43) after open elbow arthrolysis was performed for posttraumatic stiffness. Initial traumas were: isolated fractures (11) or dislocation (1) and complex fracture-dislocations (6). Initial treatments were: nonoperative (3), radial head resection (1), and ORIF (14). Patients presented predominantly with mixed contractures (combined extrinsic and intrinsic contractures). INTERVENTION: Open elbow arthrolysis. MAIN OUTCOME MEASUREMENTS: Elbow function and patient satisfaction were the principal outcome measures. At follow-up European Society for Shoulder and Elbow Surgery (SECEC) elbow scores were calculated. RESULTS AND CONCLUSIONS: Three patients had minor postoperative complications: 1 partial wound dehiscence, 1 subcutaneous infection, and one seroma. None of these complications influenced the final result clinically. The mean total increase in range of motion was 40 degrees (13 to 112 degrees), with a mean gain in flexion of 14 degrees (0 to 45 degrees) and 26 degrees in extension (5 to 67 degrees). No patient showed signs of elbow instability. There was no radiographic evidence of osteoarthritis progression at follow-up. We did not find any correlations between the type of stiffness, the approaches used, and the results. However, patients with the greatest preoperative stiffness had significantly better improvement of mobility (P<0.001). The best results were obtained in patients who had arthrolysis done within 1 year after the initial trauma (P=0.008). The mean SECEC scores were 88 (52 to 100) for the injured elbows, and 96 (88 to 100) for the contralateral elbows. CONCLUSION: Open elbow arthrolysis for patients with posttraumatic stiffness improves joint function and provides patient satisfaction. The best results, in terms of gain of motion and patient satisfaction, were obtained in patients with severe stiffness who had operations within the first year after initial trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to determine changes in spring-mass model (SMM) characteristics, plantar pressures, and muscle activity induced by the repetition of sprints in soccer-specific conditions; i.e., on natural grass with soccer shoes. Thirteen soccer players performed 6 × 20 m sprints interspersed with 20 s of passive recovery. Plantar pressure distribution was recorded via an insole pressure recorder device divided into nine areas for analysis. Stride temporal parameters allowed to estimate SMM characteristics. Surface electromyographic activity was monitored for vastus lateralis, rectus femoris, and biceps femoris muscles. Sprint time, contact time, and total stride duration lengthened from the first to the last repetition (+6.7, +12.9, and +9.3%; all P < 0.05), while flight time, swing time, and stride length remained constant. Stride frequency decrease across repetitions approached significance (-6.8%; P = 0.07). No main effect of the sprint number or any significant interaction between sprint number and foot region was found for maximal force, mean force, peak pressure and mean pressure (all P > 0.05). Center of mass vertical displacement increased (P < 0.01) with time, together with unchanged (both P > 0.05) peak vertical force and leg compression. Vertical stiffness decreased (-15.9%; P < 0.05) across trials, whereas leg stiffness changes were not significant (-5.9%; P > 0.05). Changes in root mean square activity of the three tested muscles over sprint repetitions were not significant. Although repeated sprinting on natural grass with players wearing soccer boots impairs their leg-spring behavior (vertical stiffness), there is no substantial concomitant alterations in muscle activation levels or plantar pressure patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liver stiffness values in transient elastography (TE) have to be interpreted with caution. Steatosis, congestion, acute inflammation and extrahepatic cholestasis can indeed influence measurements. Obtained stiffness values in the cirrhotic range can also be present in the absence of fibrosis as in hepatic amyloidosis. Here we report two cases of systemic amyloidosis with hepatic involvement where high stiffness values were measured at TE. In fact, deposits of amyloid may increase the rigidity of the liver parenchyma resulting in higher liver stiffness values. Therefore, results of TE should always be interpreted in their clinical context and if inconsistent, the performance of a liver biopsy might be necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the latest years the importance of high resolution analysis of the microbial cell surface has been increasingly recognized. Indeed, in order to better understand bacterial physiology and achieve rapid diagnostic and treatment techniques, a thorough investigation of the surface modifications induced on bacteria by different environmental conditions or drugs is essential. Several instruments are nowadays available to observe at high resolution specific properties of microscopic samples. Among these, AFM can routinely study single cells in physiological conditions, measuring the mechanical properties of their membrane at a nanometric scale (force volume). Such analyses, coupled with high resolution investigation of their morphological properties, are increasingly used to characterize the state of single cells. In this work we exploit such technique to characterize bacterial systems. We have performed an analysis of the mechanical properties of bacteria (Escherichia coli) exposed to different conditions. Such measurements were performed on living bacteria, by changing in real-time the liquid environment: standard phosphate buffered saline, antibiotic (ampicillin) in PBS and growth medium. In particular we have focused on the determination of the membrane stiffness modifications induced by these solutions, in particular between stationary and replicating phases and what is the effect of the antibiotic on the bacterial structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pendant la grossesse, la pression artérielle reste stable malgré une nette augmentation du volume d'éjection systolique et du débit cardiaque. Cette stabilité vient d'un côté d'une vasodilatation périphérique entraînant une diminution des résistances périphériques et d'un autre côté d'une moindre rigidité des principales artères notamment l'aorte. En conséquence, l'amplitude des ondes de pouls est atténuée, de même que leur vitesse de propagation dans le sens tant antérogade que rétrograde (ondes réfléchies). Les ondes réfléchies tendent ainsi à atteindre l'aorte ascendante plus tard durant la systole, voire durant la diastole, ce qui peut contribuer à diminuer la pression puisée. La prééclampsie perturbe massivement ce processus d'adaptation. Il s'agit d'une maladie hypertensive de la grossesse engendrant une importante morbidité et mortalité néonatale et maternelle. Il est à remarquer que la diminution de la rigidité artérielle n'est pas observée chez les patientes atteintes avec pour conséquence une forte augmentation de la pression systolique centrale (aortique) par les ondes réfléchies. Ce fait a été établi grâce à l'existence de la tonométrie d'aplanation, une méthode permettant l'évaluation non invasive de l'onde de pouls centrale. Dans cette méthode, un senseur de pression piézo-électrique permet de capter l'onde de pouls périphérique, le plus souvent sur l'artère radiale. Par la suite, un algorithme validé permet d'en déduire la forme de l'onde de pouls centrale et de visualiser à quel moment du cycle cardiaque s'y ajoutent les ondes réfléchies. Plusieurs études font état d'une forte augmentation de la pression systolique centrale par les ondes réfléchies chez les patientes atteintes de prééclampsie, suggérant l'utilisation de cette méthode pour le diagnostic et le monitoring voire pour le dépistage de ces patientes. Pour atteindre ce but, il est nécessaire d'établir des normes en rapport notamment avec l'âge gestationnel. Dans la littérature, les données pertinentes actuellement disponibles sont variables, voire contradictoires. Par exemple, les ondes réfléchies proéminentes dans la partie diastolique de l'onde de pouls centrale disparaissaient chez des patientes enceintes au 3eme trimestre comparées à des contrôles non enceintes dans une étude lausannoise, alors que deux autres études présentent l'observation contraire. Autre exemple, certains auteurs décrivent une diminution progressive de l'augmentation systolique jusqu'à l'accouchement alors que d'autres rapportent un nadir aux environs du 6ème mois, suivi d'un retour à des valeurs plus élevées en fin de grossesse. Les mesures effectuées dans toutes ces études différaient dans leur exécution, les patientes étant notamment dans des postions corporelles différentes (couchées, semi-couchées, assises, en décubitus latéral). Or nous savons que le status hémodynamique est très sensible aux changements de position, particulièrement durant la grossesse où l'utérus gravide est susceptible d'avoir des interactions mécaniques avec les veines et possiblement les artères abdominales. Ces différences méthodologiques pourraient donc expliquer, au moins en partie, l'hétérogénéité des résultats concernant l'onde de pouls chez la femme enceinte, ce qui à notre connaissance n'a jamais été exploré. Nous avons mesuré l'onde de pouls dans les positions assise et couchée chez des femmes enceintes, au 3eme trimestre d'une grossesse non compliquée, et nous avons effectué une comparaison avec des données similaire obtenues chez des femmes non enceintes en bonne santé habituelle. Les résultats montrent que la position du corps a un impact majeur sur la forme de l'onde de pouls centrale. Comparée à la position assise, la position couchée se caractérise par une moindre augmentation systolique et, par contraste, une augmentation diastolique plus marquée. De manière inattendue, cet effet s'observe aussi bien en présence qu'en l'absence de grossesse, suggérant que la cause première n'en réside pas dans les interactions mécaniques de l'utérus gravide avec les vaisseaux sanguins abdominaux. Nos observations pourraient par contre être expliquées par l'influence de la position du corps, via un phénomène hydrostatique simple, sur la pression transmurale des artères éloignées du coeur, tout particulièrement celles des membres inférieurs et de l'étage abdominal. En position verticale, ces vaisseaux augmenteraient leur rigidité pour résister à la distension de leur paroi, ce qui y accroîtrait la vitesse de propagation des ondes de pression. En l'état, cette explication reste hypothétique. Mais quoi qu'il en soit, nos résultats expliquent certaines discordances entre les études conduites à ce jour pour caractériser l'influence de la grossesse physiologique sur la forme de l'onde de pouls central. De plus, ils indiquent que la position du corps doit être prise en compte lors de toute investigation utilisant la tonométrie d'applanation pour déterminer la rigidité des artères chez les jeunes femmes enceintes ou non. Il sera aussi nécessaire d'en tenir compte pour établir des normes en vue d'une utilisation de la tonométrie d'aplanation pour dépister ou suivre les patientes atteintes de prééclampsie. Il serait enfin intéressant d'évaluer si l'effet de la position sur la forme de l'onde de pouls central existe également dans l'autre sexe et chez des personnes plus âgées.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have reported that ingesting a meal immediately after exercise increased skeletal muscle accretion and less adipose tissue accumulation in rats employed in a 10 week resistance exercise program. We hypothesized that a possible increase in the resting metabolic rate (RMR) as a result of the larger skeletal muscle mass might be responsible for the less adipose deposition. Therefore, the effect of the timing of a protein supplement after resistance exercise on body composition and the RMR was investigated in 17 slightly overweight men. The subjects participated in a 12-week weight reduction program consisting of mild energy restriction (17% energy intake reduction) and a light resistance exercise using a pair of dumbbells (3-5 kg). The subjects were assigned to two groups. Group S ingested a protein supplement (10 g protein, 7 g carbohydrate, 3.3 g fat and one-third of recommended daily allowance (RDA) of vitamins and minerals) immediately after exercise. Group C did not ingest the supplement. Daily intake of both energy and protein was equal between the two groups and the protein intake met the RDA. After 12 weeks, the bodyweight, skinfold thickness, girth of waist and hip and percentage bodyfat significantly decreased in the both groups, however, no significant differences were observed between the groups. The fat-free mass significantly decreased in C, whereas its decrease in S was not significant. The RMR and post-meal total energy output significantly increased in S, while these variables did not change in C. In addition, the urinary nitrogen excretion tended to increase in C but not in S. These results suggest that the RMR increase observed in S might be associated with an increase in body protein synthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lung volume reduction with valves is increasingly used to treat selected patients with severe emphysema. The indications for this procedure have been previously described; however, its contraindications have not yet been conclusively established. This case highlights the potentially severe complications of endobronchial one-way valve placement in the setting of a previous pleurodesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe methods and outcomes of excisional revision of a filtering bleb (bleb revision) using free conjunctival autologous graft either for bleb repair or for bleb reduction after trabeculectomy and deep sclerectomy with an implant. METHODS: Retrospective medical records were reviewed for a consecutive non-comparative case series comprising patients who underwent excisional revision of a filtering bleb between May 1998-January 2001. Excisional revision using free conjunctival autologous graft (bleb revision) was performed either for bleb repair, to treat early and late leaks and hypotony with maculopathy, or for bleb reduction, to improve ocular pain, discomfort, burning, foreign body sensation, tearing, and fluctuations of visual acuity. The revision consisted of bleb excision and free conjunctival autologous graft. The bleb histopathology was analyzed in patients who underwent bleb repair. RESULTS: Sixteen patients were included in the study, consisting of nine patients who had a trabeculectomy and seven patients who had a deep sclerectomy with an implant. Bleb revision was necessary in 14 patients due to leaking filtering bleb (bleb repair), and in 2 patients due to bleb dysesthesia (bleb reduction). After a follow-up of 15.1 +/- 8.4 months, the mean intraocular pressure (IOP) rose from 7.8 +/- 6.3 mm Hg to 14.3 +/- 6.5 mm Hg, and the visual acuity from 0.4 +/- 0.3 to 0.7 +/- 0.3, with a P value of 0.008 and 0.03, respectively. The complete success rate at 32 months, according to the Kaplan-Meier survival curve, was 38.3%, and the qualified success rate was 83.3%. Four patients (25%) required additional suturing for persistent bleb leak. To control IOP, antiglaucoma medical therapy was needed for six patients (37.5%) and repeated glaucoma surgery was needed for one patient. CONCLUSION: Free conjunctival autologous graft is a safe and successful procedure for bleb repair and bleb reduction. However, patients should be aware of the postoperative possibility of requiring medical or surgical intervention for IOP control after revision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a patient who developed, from 5 months of age, multiple seizure types, including myoclonic, associated with severe psychomotor delay, leading to the diagnosis of Dravet syndrome. Over the years, he developed refractory epilepsy and was implanted with a vagus nerve stimulator at the age of 19. After 3 months, he experienced a progressive improvement of partial and generalized seizures, with a >90% reduction, and better alertness. This meaningful clinical improvement is discussed in the light of the sudden unexpected death in epilepsy risk, which is high in this setting, and seems remarkably diminished in our patient in view of the reduction of generalized convulsions.