98 resultados para Standard Reference Intervals


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to compare a novel compressed sensing (CS)-based single-breath-hold multislice magnetic resonance cine technique with the standard multi-breath-hold technique for the assessment of left ventricular (LV) volumes and function. BACKGROUND: Cardiac magnetic resonance is generally accepted as the gold standard for LV volume and function assessment. LV function is 1 of the most important cardiac parameters for diagnosis and the monitoring of treatment effects. Recently, CS techniques have emerged as a means to accelerate data acquisition. METHODS: The prototype CS cine sequence acquires 3 long-axis and 4 short-axis cine loops in 1 single breath-hold (temporal/spatial resolution: 30 ms/1.5 × 1.5 mm(2); acceleration factor 11.0) to measure left ventricular ejection fraction (LVEFCS) as well as LV volumes and LV mass using LV model-based 4D software. For comparison, a conventional stack of multi-breath-hold cine images was acquired (temporal/spatial resolution 40 ms/1.2 × 1.6 mm(2)). As a reference for the left ventricular stroke volume (LVSV), aortic flow was measured by phase-contrast acquisition. RESULTS: In 94% of the 33 participants (12 volunteers: mean age 33 ± 7 years; 21 patients: mean age 63 ± 13 years with different LV pathologies), the image quality of the CS acquisitions was excellent. LVEFCS and LVEFstandard were similar (48.5 ± 15.9% vs. 49.8 ± 15.8%; p = 0.11; r = 0.96; slope 0.97; p < 0.00001). Agreement of LVSVCS with aortic flow was superior to that of LVSVstandard (overestimation vs. aortic flow: 5.6 ± 6.5 ml vs. 16.2 ± 11.7 ml, respectively; p = 0.012) with less variability (r = 0.91; p < 0.00001 for the CS technique vs. r = 0.71; p < 0.01 for the standard technique). The intraobserver and interobserver agreement for all CS parameters was good (slopes 0.93 to 1.06; r = 0.90 to 0.99). CONCLUSIONS: The results demonstrated the feasibility of applying the CS strategy to evaluate LV function and volumes with high accuracy in patients. The single-breath-hold CS strategy has the potential to replace the multi-breath-hold standard cardiac magnetic resonance technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Dose reduction may compromise patients because of a decrease of image quality. Therefore, the amount of dose savings in new dose-reduction techniques needs to be thoroughly assessed. To avoid repeated studies in one patient, chest computed tomography (CT) scans with different dose levels were performed in corpses comparing model-based iterative reconstruction (MBIR) as a tool to enhance image quality with current standard full-dose imaging. MATERIALS AND METHODS: Twenty-five human cadavers were scanned (CT HD750) after contrast medium injection at different, decreasing dose levels D0-D5 and respectively reconstructed with MBIR. The data at full-dose level, D0, have been additionally reconstructed with standard adaptive statistical iterative reconstruction (ASIR), which represented the full-dose baseline reference (FDBR). Two radiologists independently compared image quality (IQ) in 3-mm multiplanar reformations for soft-tissue evaluation of D0-D5 to FDBR (-2, diagnostically inferior; -1, inferior; 0, equal; +1, superior; and +2, diagnostically superior). For statistical analysis, the intraclass correlation coefficient (ICC) and the Wilcoxon test were used. RESULTS: Mean CT dose index values (mGy) were as follows: D0/FDBR = 10.1 ± 1.7, D1 = 6.2 ± 2.8, D2 = 5.7 ± 2.7, D3 = 3.5 ± 1.9, D4 = 1.8 ± 1.0, and D5 = 0.9 ± 0.5. Mean IQ ratings were as follows: D0 = +1.8 ± 0.2, D1 = +1.5 ± 0.3, D2 = +1.1 ± 0.3, D3 = +0.7 ± 0.5, D4 = +0.1 ± 0.5, and D5 = -1.2 ± 0.5. All values demonstrated a significant difference to baseline (P < .05), except mean IQ for D4 (P = .61). ICC was 0.91. CONCLUSIONS: Compared to ASIR, MBIR allowed for a significant dose reduction of 82% without impairment of IQ. This resulted in a calculated mean effective dose below 1 mSv.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Gene expression analysis has emerged as a major biological research area, with real-time quantitative reverse transcription PCR (RT-QPCR) being one of the most accurate and widely used techniques for expression profiling of selected genes. In order to obtain results that are comparable across assays, a stable normalization strategy is required. In general, the normalization of PCR measurements between different samples uses one to several control genes (e. g. housekeeping genes), from which a baseline reference level is constructed. Thus, the choice of the control genes is of utmost importance, yet there is not a generally accepted standard technique for screening a large number of candidates and identifying the best ones. Results: We propose a novel approach for scoring and ranking candidate genes for their suitability as control genes. Our approach relies on publicly available microarray data and allows the combination of multiple data sets originating from different platforms and/or representing different pathologies. The use of microarray data allows the screening of tens of thousands of genes, producing very comprehensive lists of candidates. We also provide two lists of candidate control genes: one which is breast cancer-specific and one with more general applicability. Two genes from the breast cancer list which had not been previously used as control genes are identified and validated by RT-QPCR. Open source R functions are available at http://www.isrec.isb-sib.ch/similar to vpopovic/research/ Conclusion: We proposed a new method for identifying candidate control genes for RT-QPCR which was able to rank thousands of genes according to some predefined suitability criteria and we applied it to the case of breast cancer. We also empirically showed that translating the results from microarray to PCR platform was achievable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighted spin-echo imaging of the spine has been successfully implemented for differentiation of benign fracture edema and tumor infiltration of the vertebral body. Nevertheless, this technique still suffers from insufficient image quality in numerous patients due to motion artifacts. The aim of this study was to investigate the impact of variable respiratory motion artifact suppression techniques on image quality in diffusion-weighted spin-echo imaging of the spine. In addition to phase-encoding reordering, a newly implemented right hemi-diaphragmaitc navigator for respiratory gating was used. Subjective and objective image quality parameters were compared. Respiratory motion artifact suppression has a major impact on image quality in diffusion-weighted imaging of the spine. Phase-encoding reordering does not enhance image quality while right hemi-diaphragmatic respiratory navigator gating significantly improves image quality at the cost of data acquisition time. Navigator gating should be used if standard spin-echo diffusion-weighted imaging demonstrates insufficient image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-dose dobutamine magnetic resonance stress testing has been shown to be superior to dobutamine stress echocardiography for diagnosis of coronary artery disease (CAD). We determined the feasibility of quantitative myocardial tagging during low- and high-dose dobutamine stress and tested the ability of global systolic and diastolic quantitative parameters to identify patients with significant CAD. Twenty-five patients suspected of having significant CAD were examined with a standard high-dose dobutamine/atropine stress magnetic resonance protocol (1.5-T scanner, Philips). All patients underwent invasive coronary angiography as the standard of reference for the presence (n = 13) or absence (n = 12) of significant CAD. During low-dose dobutamine stress, systolic (circumferential shortening, systolic rotation, and systolic rotation velocity) and diastolic (velocity of circumferential lengthening and diastolic rotation velocity) parameters changed significantly in patients without CAD (all P < 0.05 vs. rest) but not in patients with CAD. Identification of patients without and with CAD during low-dose stress was possible using the diastolic parameter of "time to peak untwist." At high-dose stress, none of the global systolic or diastolic parameters showed the potential to identify the presence of significant CAD. With myocardial tagging, a quantitative analysis of systolic and diastolic function was feasible during low- and high-dose dobutamine stress. In our study, the diastolic parameter of time to peak untwist as assessed during low-dose dobutamine stress was the most promising global parameter for identification of patients with significant CAD. Thus quantitative myocardial tagging may become a tool that reduces the need for high-dose dobutamine stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La douleur neuropathique est définie comme une douleur causée par une lésion du système nerveux somato-sensoriel. Elle se caractérise par des douleurs exagérées, spontanées, ou déclenchées par des stimuli normalement non douloureux (allodynie) ou douloureux (hyperalgésie). Bien qu'elle concerne 7% de la population, ses mécanismes biologiques ne sont pas encore élucidés. L'étude des variations d'expressions géniques dans les tissus-clés des voies sensorielles (notamment le ganglion spinal et la corne dorsale de la moelle épinière) à différents moments après une lésion nerveuse périphérique permettrait de mettre en évidence de nouvelles cibles thérapeutiques. Elles se détectent de manière sensible par reverse transcription quantitative real-time polymerase chain reaction (RT- qPCR). Pour garantir des résultats fiables, des guidelines ont récemment recommandé la validation des gènes de référence utilisés pour la normalisation des données ("Minimum information for publication of quantitative real-time PCR experiments", Bustin et al 2009). Après recherche dans la littérature des gènes de référence fréquemment utilisés dans notre modèle de douleur neuropathique périphérique SNI (spared nerve injury) et dans le tissu nerveux en général, nous avons établi une liste de potentiels bons candidats: Actin beta (Actb), Glyceraldehyde-3-phosphate dehydrogenase (GAPDH), ribosomal proteins 18S (18S), L13a (RPL13a) et L29 (RPL29), hypoxanthine phosphoribosyltransferase 1 (HPRT1) et hydroxymethyl-bilane synthase (HMBS). Nous avons évalué la stabilité d'expression de ces gènes dans le ganglion spinal et dans la corne dorsale à différents moments après la lésion nerveuse (SNI) en calculant des coefficients de variation et utilisant l'algorithme geNorm qui compare les niveaux d'expression entre les différents candidats et détermine la paire de gènes restante la plus stable. Il a aussi été possible de classer les gènes selon leur stabilité et d'identifier le nombre de gènes nécessaires pour une normalisation la plus précise. Les gènes les plus cités comme référence dans le modèle SNI ont été GAPDH, HMBS, Actb, HPRT1 et 18S. Seuls HPRT1 and 18S ont été précédemment validés dans des arrays de RT-qPCR. Dans notre étude, tous les gènes testés dans le ganglion spinal et dans la corne dorsale satisfont au critère de stabilité exprimé par une M-value inférieure à 1. Par contre avec un coefficient de variation (CV) supérieur à 50% dans le ganglion spinal, 18S ne peut être retenu. La paire de gènes la plus stable dans le ganglion spinal est HPRT1 et Actb et dans la corne dorsale il s'agit de RPL29 et RPL13a. L'utilisation de 2 gènes de référence stables suffit pour une normalisation fiable. Nous avons donc classé et validé Actb, RPL29, RPL13a, HMBS, GAPDH, HPRT1 et 18S comme gènes de référence utilisables dans la corne dorsale pour le modèle SNI chez le rat. Dans le ganglion spinal 18S n'a pas rempli nos critères. Nous avons aussi déterminé que la combinaison de deux gènes de référence stables suffit pour une normalisation précise. Les variations d'expression génique de potentiels gènes d'intérêts dans des conditions expérimentales identiques (SNI, tissu et timepoints post SNI) vont pouvoir se mesurer sur la base d'une normalisation fiable. Non seulement il sera possible d'identifier des régulations potentiellement importantes dans la genèse de la douleur neuropathique mais aussi d'observer les différents phénotypes évoluant au cours du temps après lésion nerveuse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Glioblastoma, the most common adult primary malignant brain tumor, confers poor prognosis (median survival of 15 months) notwithstanding aggressive treatment. Combination chemotherapy including carmustine (BCNU) or temozolomide (TMZ) with the MGMT inhibitor O6-benzylguanine (O6BG) has been used, but has been associated with dose-limiting hematopoietic toxicity. OBJECTIVE: To assess safety and efficacy of a retroviral vector encoding the O6BG-resistant MGMTP140K gene for transduction and autologous transplantation of hematopoietic stem cells (HSCs) in MGMT unmethylated, newly diagnosed glioblastoma patients in an attempt to chemoprotect bone marrowduring combination O6BG/TMZ therapy. METHODS: Three patients have been enrolled in the first cohort. Patients underwent standard radiation therapy without TMZ followed by G-CSF mobilization, apheresis, and conditioning with 600 mg/m2 BCNU prior to infusion of gene-modified cells. Posttransplant, patients were treated with 28-day cycles of single doseTMZ (472 mg/m2) with 48-hour intravenous O6BG (120 mg/m2 bolus, then 30 mg/m2/d). RESULTS: The BCNU dose was nonmyeloablative with ANC ,500/mL for ≤3 d and nadir thrombocytopenia of 28,000/mL. Gene marking in pre-infusion colony forming units (CFUs) was 70.6%, 79.0%, and 74.0% in Patients 1, 2, and 3, respectively, by CFU-PCR. Following engraftment, gene marking in white blood cells and sorted granulocytes ranged between 0.37-0.84 and 0.33-0.83 provirus copies, respectively, by real-time PCR. Posttransplant gene marking in CFUs from CD34-selected cells ranged from 28.5% to 47.4%. Patients have received 4, 3, and 2 cycles of O6BG/TMZ, respectively, with evidence for selection of gene-modified cells. One patient has received a single dose-escalated cycle at 590 mg/m2 TMZ. No additional extra-hematopoietic toxicity has been observed thus far and all three patients exhibit stable disease at 7-8 months since diagnosis CONCLUSIONS: We believe that these data demonstrate the feasibility of achieving significant engraftment of MGMTP140K-modified cells with a well-tolerated dose of BCNU. Further follow-up will determine whether this approach will allow for further dose escalation of TMZ and improved survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Species-specific chemical signals released through urine, sweat, saliva and feces are involved in communication between animals. Urinary biochemical constituents along with pheromones may contribute to variation across reproductive cycles and facilitate to estrus detection. Hence, the present study was designed to analyze such biochemical profiles, such as proteins, carbohydrates, lipids, fatty acids, in response with steroid hormones such as estradiol and progesterone. The experimental groups were normal, prepubertal, ovariectomized, and ovariectomized with estrogentreated female mice. In normal mice, the protein and lipid concentrations in urine were significantly higher in proestrus and estrus phases and the quantity of fatty acids was also comparatively higher in estrus. Furthermore, certain fatty acids, namely tridecanoic, palmitic and oleic acids, were present during proestrus and estrus phases, but were exclusively absent in ovariectomized mice. However, the carbohydrate level was equally maintained throughout the four phases of estrous cycle. For successful communication, higher concentrations of protein and specific fatty acids in estrus are directly involved. The significant increase in estradiol at estrus and progesterone at metestrus seems to be of greater importance in the expression pattern of biochemical constituents and may play a notable role in estrous cycle regulation. Thus, we conclude that the variations observed in the concentration of the biochemical constituents depend on the phase of the reproductive cycle as well as hormonal status of animals. The appearance of protein and specific fatty acids during estrus phase raises the possibility to use these as a urinary indicators for estrus detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boundaries for delta, representing a "quantitatively significant" or "substantively impressive" distinction, have not been established, analogous to the boundary of alpha, usually set at 0.05, for the stochastic or probabilistic component of "statistical significance". To determine what boundaries are being used for the "quantitative" decisions, we reviewed pertinent articles in three general medical journals. For each contrast of two means, contrast of two rates, or correlation coefficient, we noted the investigators' decisions about stochastic significance, stated in P values or confidence intervals, and about quantitative significance, indicated by interpretive comments. The boundaries between impressive and unimpressive distinctions were best formed by a ratio of greater than or equal to 1.2 for the smaller to the larger mean in 546 comparisons, by a standardized increment of greater than or equal to 0.28 and odds ratio of greater than or equal to 2.2 in 392 comparisons of two rates; and by an r value of greater than or equal to 0.32 in 154 correlation coefficients. Additional boundaries were also identified for "substantially" and "highly" significant quantitative distinctions. Although the proposed boundaries should be kept flexible, indexes and boundaries for decisions about "quantitative significance" are particularly useful when a value of delta must be chosen for calculating sample size before the research is done, and when the "statistical significance" of completed research is appraised for its quantitative as well as stochastic components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

National and international registries are essential tools for establishing new standards and comparing success rates, but they do not take into account the total pregnancy/delivery rate per oocyte recovery. In Switzerland and Germany, because of legal constraints, a maximum of three two-pronuclear zygotes are allocated for transfer whereas all the supernumerary pronuclear zygotes are immediately cryopreserved, preventing selection of the transferred embryos. We report on a 10 years' experience (1993-2002) of our centre which performs transfers of unselected embryos and cryopreservation at the two-pronuclear zygote stage. As approximately 30% of all deliveries are from cryo cycles, it is essential to take into account the contribution of the cryo transfers, and we propose therefore to evaluate, as a measure of IVF performance, the cumulated delivery rate per oocyte pick-up. This delivery rate is broken down further into the cumulated singleton delivery rate (CUSIDERA) and the cumulated twin delivery rate (CUTWIDERA). The sum (S) of these two rates is a measure of efficacy while the ratio CUTWIDERA/S as a percentage is a measure of safety of IVF treatments. Using these new indexes, the average 10 year efficacy and safety of our IVF programme were 26 and 19%, respectively. Both CUSIDERA and CUTWIDERA can be calculated easily in any clinical situation and yield useful parameters for patient counselling and internal/external benchmarking purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, analysis of the genomes of many organisms has received increasing international attention. The bulk of the effort to date has centred on the Human Genome Project and analysis of model organisms such as yeast, Drosophila and Caenorhabditis elegans. More recently, the revolution in genome sequencing and gene identification has begun to impact on infectious disease organisms. Initially, much of the effort was concentrated on prokaryotes, but small eukaryotic genomes, including the protozoan parasites Plasmodium, Toxoplasma and trypanosomatids (Leishmania, Trypanosoma brucei and T. cruzi), as well as some multicellular organisms, such as Brugia and Schistosoma, are benefiting from the technological advances of the genome era. These advances promise a radical new approach to the development of novel diagnostic tools, chemotherapeutic targets and vaccines for infectious disease organisms, as well as to the more detailed analysis of cell biology and function.Several networks or consortia linking laboratories around the world have been established to support these parasite genome projects[1] (for more information, see http://www.ebi.ac.uk/ parasites/paratable.html). Five of these networks were supported by an initiative launched in 1994 by the Specific Programme for Research and Tropical Diseases (TDR) of the WHO[2, 3, 4, 5, 6]. The Leishmania Genome Network (LGN) is one of these[3]. Its activities are reported at http://www.ebi.ac.uk/parasites/leish.html, and its current aim is to map and sequence the genome of Leishmania by the year 2002. All the mapping, hybridization and sequence data are also publicly available from LeishDB, an AceDB-based genome database (http://www.ebi.ac.uk/parasites/LGN/leissssoft.html).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the diagnostic performance of respiratory self-navigation for whole-heart coronary magnetic resonance (MR) angiography in a patient cohort referred for diagnostic cardiac MR imaging. MATERIALS AND METHODS: Written informed consent was obtained from all participants for this institutional review board-approved study. Self-navigated coronary MR angiography was performed after administration of a contrast agent in 78 patients (mean age, 48.5 years ± 20.7 [standard deviation]; 53 male patients) referred for cardiac MR imaging because of coronary artery disease (n = 40), cardiomyopathy (n = 14), congenital anomaly (n = 17), or "other" (n = 7). Examination duration was recorded, and the image quality for each coronary segment was assessed with consensus reading. Vessel sharpness, length, and diameter were measured. Quantitative values in proximal, middle, and distal segments were compared by using analysis of variance and t tests. A double-blinded comparison with the results of x-ray angiography was performed when such results were available. RESULTS: When patients with different indications for cardiac MR imaging were examined with self-navigated postcontrast coronary MR angiography, whole-heart data sets with 1.15-mm isotropic spatial resolution were acquired in an average of 7.38 minutes ± 1.85. The main and proximal coronary segments could be visualized in 92.3% of cases, while the middle and distal segments could be visualized in 84.0% and 55.8% of cases, respectively. Subjective scores and vessel sharpness were significantly higher in the proximal segments than in the middle and distal segments (P < .05). Anomalies of the coronary arteries could be confirmed or excluded in all cases. Per-vessel sensitivity and specificity for stenosis detection were 64.7% and 85.0%, respectively, in the 31 patients for whom reference standard x-ray coronary angiography results were available. CONCLUSION: The self-navigated coronary MR angiography sequence shows promise for coronary imaging. However, technical improvements are needed to improve image quality, especially in the more distal coronary segments.