71 resultados para Spherical cavities
Resumo:
Molecular docking softwares are one of the important tools of modern drug development pipelines. The promising achievements of the last 10 years emphasize the need for further improvement, as reflected by several recent publications (Leach et al., J Med Chem 2006, 49, 5851; Warren et al., J Med Chem 2006, 49, 5912). Our initial approach, EADock, showed a good performance in reproducing the experimental binding modes for a set of 37 different ligand-protein complexes (Grosdidier et al., Proteins 2007, 67, 1010). This article presents recent improvements regarding the scoring and sampling aspects over the initial implementation, as well as a new seeding procedure based on the detection of cavities, opening the door to blind docking with EADock. These enhancements were validated on 260 complexes taken from the high quality Ligand Protein Database [LPDB, (Roche et al., J Med Chem 2001, 44, 3592)]. Two issues were identified: first, the quality of the initial structures cannot be assumed and a manual inspection and/or a search in the literature are likely to be required to achieve the best performance. Second the description of interactions involving metal ions still has to be improved. Nonetheless, a remarkable success rate of 65% was achieved for a large scale blind docking assay, when considering only the top ranked binding mode and a success threshold of 2 A RMSD to the crystal structure. When looking at the five-top ranked binding modes, the success rate increases up to 76%. In a standard local docking assay, success rates of 75 and 83% were obtained, considering only the top ranked binding mode, or the five top binding modes, respectively.
Resumo:
La collaboration CLIC (Compact LInear Collider, collisionneur linéaire compact) étudie la possibilité de réaliser un collisionneur électron-positon linéaire à haute énergie (3 TeV dans le centre de masse) et haute luminosité (1034 cm-2s-1), pour la recherche en physique des particules. Le projet CLIC se fonde sur l'utilisation de cavités accélératrices à haute fréquence (30 GHz). La puissance nécessaire à ces cavités est fournie par un faisceau d'électrons de basse énergie et de haute intensité, appelé faisceau de puissance, circulant parallèlement à l'accélérateur linéaire principal (procédé appelé « Accélération à Double Faisceau »). Dans ce schéma, un des principaux défis est la réalisation du faisceau de puissance, qui est d'abord généré dans un complexe accélérateur à basse fréquence, puis transformé pour obtenir une structure temporelle à haute fréquence nécessaire à l'alimentation des cavités accélératrices de l'accélérateur linéaire principal. La structure temporelle à haute fréquence des paquets d'électrons est obtenue par le procédé de multiplication de fréquence, dont la manipulation principale consiste à faire circuler le faisceau d'électrons dans un anneau isochrone en utilisant des déflecteurs radio-fréquence (déflecteurs RF) pour injecter et combiner les paquets d'électrons. Cependant, ce type de manipulation n'a jamais été réalisé auparavant et la première phase de la troisième installation de test pour CLIC (CLIC Test Facility 3 ou CTF3) a pour but la démonstration à faible charge du procédé de multiplication de fréquence par injection RF dans un anneau isochrone. Cette expérience, qui a été réalisée avec succès au CERN au cours de l'année 2002 en utilisant une version modifiée du pré-injecteur du grand collisionneur électron-positon LEP (Large Electron Positron), est le sujet central de ce rapport. L'expérience de combinaison des paquets d'électrons consiste à accélérer cinq impulsions dont les paquets d'électrons sont espacés de 10 cm, puis à les combiner dans un anneau isochrone pour obtenir une seule impulsion dont les paquets d'électrons sont espacés de 2 cm, multipliant ainsi la fréquence des paquets d'électrons, ainsi que la charge par impulsion, par cinq. Cette combinaison est réalisée au moyen de structures RF résonnantes sur un mode déflecteur, qui créent dans l'anneau une déformation locale et dépendante du temps de l'orbite du faisceau. Ce mécanisme impose plusieurs contraintes de dynamique de faisceau comme l'isochronicité, ainsi que des tolérances spécifiques sur les paquets d'électrons, qui sont définies dans ce rapport. Les études pour la conception de la Phase Préliminaire du CTF3 sont détaillées, en particulier le nouveau procédé d'injection avec les déflecteurs RF. Les tests de haute puissance réalisés sur ces cavités déflectrices avant leur installation dans l'anneau sont également décrits. L'activité de mise en fonctionnement de l'expérience est présentée en comparant les mesures faites avec le faisceau aux simulations et calculs théoriques. Finalement, les expériences de multiplication de fréquence des paquets d'électrons sont décrites et analysées. On montre qu'une très bonne efficacité de combinaison est possible après optimisation des paramètres de l'injection et des déflecteurs RF. En plus de l'expérience acquise sur l'utilisation de ces déflecteurs, des conclusions importantes pour les futures activités CTF3 et CLIC sont tirées de cette première démonstration de la multiplication de fréquence des paquets d'électrons par injection RF dans un anneau isochrone.<br/><br/>The Compact LInear Collider (CLIC) collaboration studies the possibility of building a multi-TeV (3 TeV centre-of-mass), high-luminosity (1034 cm-2s-1) electron-positron collider for particle physics. The CLIC scheme is based on high-frequency (30 GHz) linear accelerators powered by a low-energy, high-intensity drive beam running parallel to the main linear accelerators (Two-Beam Acceleration concept). One of the main challenges to realize this scheme is to generate the drive beam in a low-frequency accelerator and to achieve the required high-frequency bunch structure needed for the final acceleration. In order to provide bunch frequency multiplication, the main manipulation consists in sending the beam through an isochronous combiner ring using radio-frequency (RF) deflectors to inject and combine electron bunches. However, such a scheme has never been used before, and the first stage of the CLIC Test Facility 3 (CTF3) project aims at a low-charge demonstration of the bunch frequency multiplication by RF injection into an isochronous ring. This proof-of-principle experiment, which was successfully performed at CERN in 2002 using a modified version of the LEP (Large Electron Positron) pre-injector complex, is the central subject of this report. The bunch combination experiment consists in accelerating in a linear accelerator five pulses in which the electron bunches are spaced by 10 cm, and combining them in an isochronous ring to obtain one pulse in which the electron bunches are spaced by 2 cm, thus achieving a bunch frequency multiplication of a factor five, and increasing the charge per pulse by a factor five. The combination is done by means of RF deflecting cavities that create a time-dependent bump inside the ring, thus allowing the interleaving of the bunches of the five pulses. This process imposes several beam dynamics constraints, such as isochronicity, and specific tolerances on the electron bunches that are defined in this report. The design studies of the CTF3 Preliminary Phase are detailed, with emphasis on the novel injection process using RF deflectors. The high power tests performed on the RF deflectors prior to their installation in the ring are also reported. The commissioning activity is presented by comparing beam measurements to model simulations and theoretical expectations. Eventually, the bunch frequency multiplication experiments are described and analysed. It is shown that the process of bunch frequency multiplication is feasible with a very good efficiency after a careful optimisation of the injection and RF deflector parameters. In addition to the experience acquired in the operation of these RF deflectors, important conclusions for future CTF3 and CLIC activities are drawn from this first demonstration of the bunch frequency multiplication by RF injection into an isochronous ring.<br/><br/>La collaboration CLIC (Compact LInear Collider, collisionneur linéaire compact) étudie la possibilité de réaliser un collisionneur électron-positon linéaire à haute énergie (3 TeV) pour la recherche en physique des particules. Le projet CLIC se fonde sur l'utilisation de cavités accélératrices à haute fréquence (30 GHz). La puissance nécessaire à ces cavités est fournie par un faisceau d'électrons de basse énergie et de haut courant, appelé faisceau de puissance, circulant parallèlement à l'accélérateur linéaire principal (procédé appelé « Accélération à Double Faisceau »). Dans ce schéma, un des principaux défis est la réalisation du faisceau de puissance, qui est d'abord généré dans un complexe accélérateur à basse fréquence, puis transformé pour obtenir une structure temporelle à haute fréquence nécessaire à l'alimentation des cavités accélératrices de l'accélérateur linéaire principal. La structure temporelle à haute fréquence des paquets d'électrons est obtenue par le procédé de multiplication de fréquence, dont la manipulation principale consiste à faire circuler le faisceau d'électrons dans un anneau isochrone en utilisant des déflecteurs radio-fréquence (déflecteurs RF) pour injecter et combiner les paquets d'électrons. Cependant, ce type de manipulation n'a jamais été réalisé auparavant et la première phase de la troisième installation de test pour CLIC (CLIC Test Facility 3 ou CTF3) a pour but la démonstration à faible charge du procédé de multiplication de fréquence par injection RF dans un anneau isochrone. L'expérience consiste à accélérer cinq impulsions, puis à les combiner dans un anneau isochrone pour obtenir une seule impulsion dans laquelle la fréquence des paquets d'électrons et le courant sont multipliés par cinq. Cette combinaison est réalisée au moyen de structures déflectrices RF qui créent dans l'anneau une déformation locale et dépendante du temps de la trajectoire du faisceau. Les résultats de cette expérience, qui a été réalisée avec succès au CERN au cours de l?année 2002 en utilisant une version modifiée du pré-injecteur du grand collisionneur électron-positon LEP (Large Electron Positon), sont présentés en détail.
Resumo:
Un système efficace de sismique tridimensionnelle (3-D) haute-résolution adapté à des cibles lacustres de petite échelle a été développé. Dans le Lac Léman, près de la ville de Lausanne, en Suisse, des investigations récentes en deux dimension (2-D) ont mis en évidence une zone de faille complexe qui a été choisie pour tester notre système. Les structures observées incluent une couche mince (<40 m) de sédiments quaternaires sub-horizontaux, discordants sur des couches tertiaires de molasse pentées vers le sud-est. On observe aussi la zone de faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau de la Molasse Subalpine. Deux campagnes 3-D complètes, d?environ d?un kilomètre carré, ont été réalisées sur ce site de test. La campagne pilote (campagne I), effectuée en 1999 pendant 8 jours, a couvert 80 profils en utilisant une seule flûte. Pendant la campagne II (9 jours en 2001), le nouveau système trois-flûtes, bien paramétrés pour notre objectif, a permis l?acquisition de données de très haute qualité sur 180 lignes CMP. Les améliorations principales incluent un système de navigation et de déclenchement de tirs grâce à un nouveau logiciel. Celui-ci comprend un contrôle qualité de la navigation du bateau en temps réel utilisant un GPS différentiel (dGPS) à bord et une station de référence près du bord du lac. De cette façon, les tirs peuvent être déclenchés tous les 5 mètres avec une erreur maximale non-cumulative de 25 centimètres. Tandis que pour la campagne I la position des récepteurs de la flûte 48-traces a dû être déduite à partir des positions du bateau, pour la campagne II elle ont pu être calculées précisément (erreur <20 cm) grâce aux trois antennes dGPS supplémentaires placées sur des flotteurs attachés à l?extrémité de chaque flûte 24-traces. Il est maintenant possible de déterminer la dérive éventuelle de l?extrémité des flûtes (75 m) causée par des courants latéraux ou de petites variations de trajet du bateau. De plus, la construction de deux bras télescopiques maintenant les trois flûtes à une distance de 7.5 m les uns des autres, qui est la même distance que celle entre les lignes naviguées de la campagne II. En combinaison avec un espacement de récepteurs de 2.5 m, la dimension de chaque «bin» de données 3-D de la campagne II est de 1.25 m en ligne et 3.75 m latéralement. L?espacement plus grand en direction « in-line » par rapport à la direction «cross-line» est justifié par l?orientation structurale de la zone de faille perpendiculaire à la direction «in-line». L?incertitude sur la navigation et le positionnement pendant la campagne I et le «binning» imprécis qui en résulte, se retrouve dans les données sous forme d?une certaine discontinuité des réflecteurs. L?utilisation d?un canon à air à doublechambre (qui permet d?atténuer l?effet bulle) a pu réduire l?aliasing observé dans les sections migrées en 3-D. Celui-ci était dû à la combinaison du contenu relativement haute fréquence (<2000 Hz) du canon à eau (utilisé à 140 bars et à 0.3 m de profondeur) et d?un pas d?échantillonnage latéral insuffisant. Le Mini G.I 15/15 a été utilisé à 80 bars et à 1 m de profondeur, est mieux adapté à la complexité de la cible, une zone faillée ayant des réflecteurs pentés jusqu?à 30°. Bien que ses fréquences ne dépassent pas les 650 Hz, cette source combine une pénétration du signal non-aliasé jusqu?à 300 m dans le sol (par rapport au 145 m pour le canon à eau) pour une résolution verticale maximale de 1.1 m. Tandis que la campagne I a été acquise par groupes de plusieurs lignes de directions alternées, l?optimisation du temps d?acquisition du nouveau système à trois flûtes permet l?acquisition en géométrie parallèle, ce qui est préférable lorsqu?on utilise une configuration asymétrique (une source et un dispositif de récepteurs). Si on ne procède pas ainsi, les stacks sont différents selon la direction. Toutefois, la configuration de flûtes, plus courtes que pour la compagne I, a réduit la couverture nominale, la ramenant de 12 à 6. Une séquence classique de traitement 3-D a été adaptée à l?échantillonnage à haute fréquence et elle a été complétée par deux programmes qui transforment le format non-conventionnel de nos données de navigation en un format standard de l?industrie. Dans l?ordre, le traitement comprend l?incorporation de la géométrie, suivi de l?édition des traces, de l?harmonisation des «bins» (pour compenser l?inhomogénéité de la couverture due à la dérive du bateau et de la flûte), de la correction de la divergence sphérique, du filtrage passe-bande, de l?analyse de vitesse, de la correction DMO en 3-D, du stack et enfin de la migration 3-D en temps. D?analyses de vitesse détaillées ont été effectuées sur les données de couverture 12, une ligne sur deux et tous les 50 CMP, soit un nombre total de 600 spectres de semblance. Selon cette analyse, les vitesses d?intervalles varient de 1450-1650 m/s dans les sédiments non-consolidés et de 1650-3000 m/s dans les sédiments consolidés. Le fait que l?on puisse interpréter plusieurs horizons et surfaces de faille dans le cube, montre le potentiel de cette technique pour une interprétation tectonique et géologique à petite échelle en trois dimensions. On distingue cinq faciès sismiques principaux et leurs géométries 3-D détaillées sur des sections verticales et horizontales: les sédiments lacustres (Holocène), les sédiments glacio-lacustres (Pléistocène), la Molasse du Plateau, la Molasse Subalpine de la zone de faille (chevauchement) et la Molasse Subalpine au sud de cette zone. Les couches de la Molasse du Plateau et de la Molasse Subalpine ont respectivement un pendage de ~8° et ~20°. La zone de faille comprend de nombreuses structures très déformées de pendage d?environ 30°. Des tests préliminaires avec un algorithme de migration 3-D en profondeur avant sommation et à amplitudes préservées démontrent que la qualité excellente des données de la campagne II permet l?application de telles techniques à des campagnes haute-résolution. La méthode de sismique marine 3-D était utilisée jusqu?à présent quasi-exclusivement par l?industrie pétrolière. Son adaptation à une échelle plus petite géographiquement mais aussi financièrement a ouvert la voie d?appliquer cette technique à des objectifs d?environnement et du génie civil.<br/><br/>An efficient high-resolution three-dimensional (3-D) seismic reflection system for small-scale targets in lacustrine settings was developed. In Lake Geneva, near the city of Lausanne, Switzerland, past high-resolution two-dimensional (2-D) investigations revealed a complex fault zone (the Paudèze thrust zone), which was subsequently chosen for testing our system. Observed structures include a thin (<40 m) layer of subhorizontal Quaternary sediments that unconformably overlie southeast-dipping Tertiary Molasse beds and the Paudèze thrust zone, which separates Plateau and Subalpine Molasse units. Two complete 3-D surveys have been conducted over this same test site, covering an area of about 1 km2. In 1999, a pilot survey (Survey I), comprising 80 profiles, was carried out in 8 days with a single-streamer configuration. In 2001, a second survey (Survey II) used a newly developed three-streamer system with optimized design parameters, which provided an exceptionally high-quality data set of 180 common midpoint (CMP) lines in 9 days. The main improvements include a navigation and shot-triggering system with in-house navigation software that automatically fires the gun in combination with real-time control on navigation quality using differential GPS (dGPS) onboard and a reference base near the lake shore. Shots were triggered at 5-m intervals with a maximum non-cumulative error of 25 cm. Whereas the single 48-channel streamer system of Survey I requires extrapolation of receiver positions from the boat position, for Survey II they could be accurately calculated (error <20 cm) with the aid of three additional dGPS antennas mounted on rafts attached to the end of each of the 24- channel streamers. Towed at a distance of 75 m behind the vessel, they allow the determination of feathering due to cross-line currents or small course variations. Furthermore, two retractable booms hold the three streamers at a distance of 7.5 m from each other, which is the same distance as the sail line interval for Survey I. With a receiver spacing of 2.5 m, the bin dimension of the 3-D data of Survey II is 1.25 m in in-line direction and 3.75 m in cross-line direction. The greater cross-line versus in-line spacing is justified by the known structural trend of the fault zone perpendicular to the in-line direction. The data from Survey I showed some reflection discontinuity as a result of insufficiently accurate navigation and positioning and subsequent binning errors. Observed aliasing in the 3-D migration was due to insufficient lateral sampling combined with the relatively high frequency (<2000 Hz) content of the water gun source (operated at 140 bars and 0.3 m depth). These results motivated the use of a double-chamber bubble-canceling air gun for Survey II. A 15 / 15 Mini G.I air gun operated at 80 bars and 1 m depth, proved to be better adapted for imaging the complexly faulted target area, which has reflectors dipping up to 30°. Although its frequencies do not exceed 650 Hz, this air gun combines a penetration of non-aliased signal to depths of 300 m below the water bottom (versus 145 m for the water gun) with a maximum vertical resolution of 1.1 m. While Survey I was shot in patches of alternating directions, the optimized surveying time of the new threestreamer system allowed acquisition in parallel geometry, which is preferable when using an asymmetric configuration (single source and receiver array). Otherwise, resulting stacks are different for the opposite directions. However, the shorter streamer configuration of Survey II reduced the nominal fold from 12 to 6. A 3-D conventional processing flow was adapted to the high sampling rates and was complemented by two computer programs that format the unconventional navigation data to industry standards. Processing included trace editing, geometry assignment, bin harmonization (to compensate for uneven fold due to boat/streamer drift), spherical divergence correction, bandpass filtering, velocity analysis, 3-D DMO correction, stack and 3-D time migration. A detailed semblance velocity analysis was performed on the 12-fold data set for every second in-line and every 50th CMP, i.e. on a total of 600 spectra. According to this velocity analysis, interval velocities range from 1450-1650 m/s for the unconsolidated sediments and from 1650-3000 m/s for the consolidated sediments. Delineation of several horizons and fault surfaces reveal the potential for small-scale geologic and tectonic interpretation in three dimensions. Five major seismic facies and their detailed 3-D geometries can be distinguished in vertical and horizontal sections: lacustrine sediments (Holocene) , glaciolacustrine sediments (Pleistocene), Plateau Molasse, Subalpine Molasse and its thrust fault zone. Dips of beds within Plateau and Subalpine Molasse are ~8° and ~20°, respectively. Within the fault zone, many highly deformed structures with dips around 30° are visible. Preliminary tests with 3-D preserved-amplitude prestack depth migration demonstrate that the excellent data quality of Survey II allows application of such sophisticated techniques even to high-resolution seismic surveys. In general, the adaptation of the 3-D marine seismic reflection method, which to date has almost exclusively been used by the oil exploration industry, to a smaller geographical as well as financial scale has helped pave the way for applying this technique to environmental and engineering purposes.<br/><br/>La sismique réflexion est une méthode d?investigation du sous-sol avec un très grand pouvoir de résolution. Elle consiste à envoyer des vibrations dans le sol et à recueillir les ondes qui se réfléchissent sur les discontinuités géologiques à différentes profondeurs et remontent ensuite à la surface où elles sont enregistrées. Les signaux ainsi recueillis donnent non seulement des informations sur la nature des couches en présence et leur géométrie, mais ils permettent aussi de faire une interprétation géologique du sous-sol. Par exemple, dans le cas de roches sédimentaires, les profils de sismique réflexion permettent de déterminer leur mode de dépôt, leurs éventuelles déformations ou cassures et donc leur histoire tectonique. La sismique réflexion est la méthode principale de l?exploration pétrolière. Pendant longtemps on a réalisé des profils de sismique réflexion le long de profils qui fournissent une image du sous-sol en deux dimensions. Les images ainsi obtenues ne sont que partiellement exactes, puisqu?elles ne tiennent pas compte de l?aspect tridimensionnel des structures géologiques. Depuis quelques dizaines d?années, la sismique en trois dimensions (3-D) a apporté un souffle nouveau à l?étude du sous-sol. Si elle est aujourd?hui parfaitement maîtrisée pour l?imagerie des grandes structures géologiques tant dans le domaine terrestre que le domaine océanique, son adaptation à l?échelle lacustre ou fluviale n?a encore fait l?objet que de rares études. Ce travail de thèse a consisté à développer un système d?acquisition sismique similaire à celui utilisé pour la prospection pétrolière en mer, mais adapté aux lacs. Il est donc de dimension moindre, de mise en oeuvre plus légère et surtout d?une résolution des images finales beaucoup plus élevée. Alors que l?industrie pétrolière se limite souvent à une résolution de l?ordre de la dizaine de mètres, l?instrument qui a été mis au point dans le cadre de ce travail permet de voir des détails de l?ordre du mètre. Le nouveau système repose sur la possibilité d?enregistrer simultanément les réflexions sismiques sur trois câbles sismiques (ou flûtes) de 24 traces chacun. Pour obtenir des données 3-D, il est essentiel de positionner les instruments sur l?eau (source et récepteurs des ondes sismiques) avec une grande précision. Un logiciel a été spécialement développé pour le contrôle de la navigation et le déclenchement des tirs de la source sismique en utilisant des récepteurs GPS différentiel (dGPS) sur le bateau et à l?extrémité de chaque flûte. Ceci permet de positionner les instruments avec une précision de l?ordre de 20 cm. Pour tester notre système, nous avons choisi une zone sur le Lac Léman, près de la ville de Lausanne, où passe la faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau et de la Molasse Subalpine. Deux campagnes de mesures de sismique 3-D y ont été réalisées sur une zone d?environ 1 km2. Les enregistrements sismiques ont ensuite été traités pour les transformer en images interprétables. Nous avons appliqué une séquence de traitement 3-D spécialement adaptée à nos données, notamment en ce qui concerne le positionnement. Après traitement, les données font apparaître différents faciès sismiques principaux correspondant notamment aux sédiments lacustres (Holocène), aux sédiments glacio-lacustres (Pléistocène), à la Molasse du Plateau, à la Molasse Subalpine de la zone de faille et la Molasse Subalpine au sud de cette zone. La géométrie 3-D détaillée des failles est visible sur les sections sismiques verticales et horizontales. L?excellente qualité des données et l?interprétation de plusieurs horizons et surfaces de faille montrent le potentiel de cette technique pour les investigations à petite échelle en trois dimensions ce qui ouvre des voies à son application dans les domaines de l?environnement et du génie civil.
Resumo:
OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.
Resumo:
The aim of the present study was to develop novel daptomycin-loaded acrylic microparticles with improved release profiles and antibacterial activity against two clinically relevant methicillin-susceptible and methicillin-resistant Staphylococcus aureus strains (MSSA and MRSA, respectively). Daptomycin was encapsulated into poly(methyl methacrylate) (PMMA) and PMMA-Eudragit RL 100 (EUD) microparticles by a double emulsion-solvent evaporation method. For comparison purposes similar formulations were prepared with vancomycin. Particle morphology, size distribution, encapsulation efficiency, surface charge, physicochemical properties, in vitro release and biocompatibility were assessed. Particles exhibited a micrometer size and a spherical morphology. The addition of EUD to the formulation caused a shift in the surface charge of the particles from negative zeta potential values (100% PMMA formulations) to strongly positive. It also improved daptomycin encapsulation efficiency and release, whereas vancomycin encapsulation and release were strongly hindered. Plain and antibiotic-loaded particles presented comparable biocompatibility profiles. The antibacterial activity of the particles was assessed by isothermal microcalorimetry against both MSSA and MRSA. Daptomycin-loaded PMMA-EUD particles presented the highest antibacterial activity against both strains. The addition of 30% EUD to the daptomycin-loaded PMMA particles caused a 40- and 20-fold decrease in the minimum inhibitory (MIC) and bactericidal concentration (MBC) values, respectively, when compared to the 100% PMMA formulations. On the other hand, vancomycin-loaded microparticles presented the highest antibacterial activity in PMMA particles. Unlike conventional methods, isothermal microcalorimetry proved to be a real-time, sensitive and accurate method for assessment of antibacterial activity of antibiotic-loaded polymeric microparticles. Finally, the addition of EUD to formulations proved to be a powerful strategy to improve daptomycin encapsulation efficiency and release, and consequently improving the microparticles activity against two relevant S. aureus strains.
Resumo:
Postmortem imaging consists in the non-invasive examination of bodies using medical imaging techniques. However, gas volume quantification and the interpretation of the gas collection results from cadavers remain difficult. We used whole-body postmortem multi-detector computed tomography (MDCT) followed by a full autopsy or external examination to detect the gaseous volumes in bodies. Gases were sampled from cardiac cavities, and the sample compositions were analyzed by headspace gas chromatography-mass spectrometry/thermal conductivity detection (HS-GC-MS/TCD). Three categories were defined according to the presumed origin of the gas: alteration/putrefaction, high-magnitude vital gas embolism (e.g., from scuba diving accident) and gas embolism of lower magnitude (e.g., following a traumatic injury). Cadaveric alteration gas was diagnosed even if only one gas from among hydrogen, hydrogen sulfide or methane was detected. In alteration cases, the carbon dioxide/nitrogen ratio was often >0.2, except in the case of advanced alteration, when methane presence was the best indicator. In the gas embolism cases (vital or not), hydrogen, hydrogen sulfide and methane were absent. Moreover, with high-magnitude vital gas embolisms, carbon dioxide content was >20%, and the carbon dioxide/nitrogen ratio was >0.2. With gas embolisms of lower magnitude (gas presence consecutive to a traumatic injury), carbon dioxide content was <20% and the carbon dioxide/nitrogen ratio was often <0.2. We found that gas analysis provided useful assistance to the postmortem imaging diagnosis of causes of death. Based on the quantifications of gaseous cardiac samples, reliable indicators were determined to document causes of death. MDCT examination of the body must be performed as quickly as possible, as does gas sampling, to avoid generating any artifactual alteration gases. Because of cardiac gas composition analysis, it is possible to distinguish alteration gases and gas embolisms of different magnitudes.
Resumo:
PURPOSE: To characterize perifoveal intraretinal cavities observed around full-thickness macular holes (MH) using en face optical coherence tomography and to establish correlations with histology of human and primate maculae. DESIGN: Retrospective nonconsecutive observational case series. METHODS: Macular en face scans of 8 patients with MH were analyzed to quantify the areas of hyporeflective spaces, and were compared with macular flat mounts and sections from 1 normal human donor eye and 2 normal primate eyes (Macaca fascicularis). Immunohistochemistry was used to study the distribution of glutamine synthetase, expressed by Müller cells, and zonula occludens-1, a tight-junction protein. RESULTS: The mean area of hyporeflective spaces was lower in the inner nuclear layer (INL) than in the complex formed by the outer plexiform (OPL) and the Henle fiber layers (HFL): 5.0 × 10(-3) mm(2) vs 15.9 × 10(-3) mm(2), respectively (P < .0001, Kruskal-Wallis test). In the OPL and HFL, cavities were elongated with a stellate pattern, whereas in the INL they were rounded and formed vertical cylinders. Immunohistochemistry confirmed that Müller cells followed a radial distribution around the fovea in the frontal plane and a "Z-shaped" course in the axial plane, running obliquely in the OPL and HFL and vertically in the inner layers. In addition, zonula occludens-1 co-localized with Müller cells within the complex of OPL and HFL, indicating junctions in between Müller cells and cone axons. CONCLUSION: The dual profile of cavities around MHs correlates with Müller cell morphology and is consistent with the hypothesis of intra- or extracellular fluid accumulation along these cells.
Resumo:
The aim of the present study was to develop novel daptomycin-loaded poly-epsilon-caprolactone (PCL) microparticles with enhanced antibiofilm activity against mature biofilms of clinically relevant bacteria, methicillin-resistant Staphylococcus aureus (MRSA) and polysaccharide intercellular adhesin-positive Staphylococcus epidermidis. Daptomycin was encapsulated into PCL microparticles by a double emulsion-solvent evaporation method. For comparison purposes, formulations containing vancomycin were also prepared. Particle morphology, size distribution, encapsulation efficiency, surface charge, thermal behavior, and in vitro release were assessed. All formulations exhibited a spherical morphology, micrometer size, and negative surface charge. From a very early time stage, the released concentrations of daptomycin and vancomycin were higher than the minimal inhibitory concentration and continued so up to 72 hours. Daptomycin presented a sustained release profile with increasing concentrations of the drug being released up to 72 hours, whereas the release of vancomycin stabilized at 24 hours. The antibacterial activity of the microparticles was assessed by isothermal microcalorimetry against planktonic and sessile MRSA and S. epidermidis. Regarding planktonic bacteria, daptomycin-loaded PCL microparticles presented the highest antibacterial activity against both strains. Isothermal microcalorimetry also revealed that lower concentrations of daptomycin-loaded microparticles were required to completely inhibit the recovery of mature MRSA and S. epidermidis biofilms. Further characterization of the effect of daptomycin-loaded PCL microparticles on mature biofilms was performed by fluorescence in situ hybridization. Fluorescence in situ hybridization showed an important reduction in MRSA biofilm, whereas S. epidermidis biofilms, although inhibited, were not eradicated. In addition, an important attachment of the microparticles to MRSA and S. epidermidis biofilms was observed. Finally, all formulations proved to be biocompatible with both ISO compliant L929 fibroblasts and human MG63 osteoblast-like cells.
Resumo:
In the wild, animals have developed survival strategies relying on their senses. The individual ability to identify threatening situations is crucial and leads to increase in the overall fitness of the species. Rodents, for example have developed in their nasal cavities specialized olfactory neurons implicated in the detection of volatile cues encoding for impending danger such as predator scents or alarm pheromones. In particular, the neurons of the Grueneberg ganglion (GG), an olfactory subsystem, are implicated in the detection of danger cues sharing a similar chemical signature, a heterocyclic sulfur- or nitrogen-containing motif. Here we used a "from the wild to the lab" approach to identify new molecules that are involuntarily emitted by predators and that initiate fear-related responses in the recipient animal, the putative prey. We collected urines from carnivores as sources of predator scents and first verified their impact on the blood pressure of the mice. With this approach, the urine of the mountain lion emerged as the most potent source of chemical stress. We then identified in this biological fluid, new volatile cues with characteristic GG-related fingerprints, in particular the methylated pyridine structures, 2,4-lutidine and its analogs. We finally verified their encoded danger quality and demonstrated their ability to mimic the effects of the predator urine on GG neurons, on mice blood pressure and in behavioral experiments. In summary, we were able to identify here, with the use of an integrative approach, new relevant molecules, the pyridine analogs, implicated in interspecies danger communication.
Resumo:
Understanding molecular recognition is one major requirement for drug discovery and design. Physicochemical and shape complementarity between two binding partners is the driving force during complex formation. In this study, the impact of shape within this process is analyzed. Protein binding pockets and co-crystallized ligands are represented by normalized principal moments of inertia ratios (NPRs). The corresponding descriptor space is triangular, with its corners occupied by spherical, discoid, and elongated shapes. An analysis of a selected set of sc-PDB complexes suggests that pockets and bound ligands avoid spherical shapes, which are, however, prevalent in small unoccupied pockets. Furthermore, a direct shape comparison confirms previous studies that on average only one third of a pocket is filled by its bound ligand, supplemented by a 50 % subpocket coverage. In this study, we found that shape complementary is expressed by low pairwise shape distances in NPR space, short distances between the centers-of-mass, and small deviations in the angle between the first principal ellipsoid axes. Furthermore, it is assessed how different binding pocket parameters are related to bioactivity and binding efficiency of the co-crystallized ligand. In addition, the performance of different shape and size parameters of pockets and ligands is evaluated in a virtual screening scenario performed on four representative targets.
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.