76 resultados para SLAM RGB-D SlamDunk Android 3D mobile


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Xenobiotic exposure is a risk factor in the etiology of neurodegenerative disease. It was recently hypothesized that restricted exposure during brain development could predispose for a neurodegenerative disease later in life. As neuroinflammation contributes to progressive neurodegeneration, it is suspected that neurodevelopmental xenobiotic exposure could elicit a neuroinflammatory process, which over time may assume a detrimental character. We investigated the neurotoxic effects of paraquat (PQ) in three-dimensional whole rat brain cell cultures, exposed during an early differentiation stage, comparing immediate effects-directly post exposure-with long-term effects, 20 days after interrupted PQ-administration. Adverse effects and neuroinflammatory responses were assessed by measuring changes in gene- and protein-expression as well as by determining cell morphology changes. Differentiating neural cultures were highly susceptible to PQ and showed neuronal damage and strong astrogliosis. After the 20-day washout period, neurons partially recovered, whereas astrogliosis persisted, and was accompanied by microglial activation of a neurodegenerative phenotype. Our data shows that immediate and long-term effects of subchronic PQ-exposure differ. Also, PQ-exposure during this window of extensive neuronal differentiation led to a delayed microglial activation, of a character that could promote further pro-inflammatory signals that enable prolonged inflammation, thereby fueling further neurodegeneration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: To compare the different schemes that have been proposed during the last thirteen years to explain the renewal of the corneal epithelium. Material and Methods:We analyzed all the data present in the literature to explain the renewal of the corneal epithelium in mammals. According to the schemes proposed in the literature we developed a 3D animation to facilitate the understanding of the different concepts. Results:Three different schemes have been proposed to explain the renewal of the corneal epithelium in mammals during the last thirteen years. 1950-1981: the corneal epithelium was thought being renewed by mitosis of cells located in the basal layer. At this time scientist were not talking about stem cells. 1981-1986 was the period of the "XYZ hypothesis" or the transdifferentiation paradigm. At this time the conjunctival epithelium renewed the corneal epithelium in a centripetal migration. 1986-2008: the limbal stem cell paradigm, there were no stem cells in the corneal epithelium, all the corneal stem cells were located in the limbus and renewed the central cornea after a migration of 6 to 7 mm of transient amplifying cells toward the centre of the cornea. 2008, epithelial stem cells were found in the central cornea in mammals (Nature, Majo et al. November 2008). Discussion:We thought that the renewal of the corneal epithelium was completely defined. According to the last results we published in Nature, the current paradigm will be revisited. The experiments we made were on animals and the final demonstration on human has still to be done. If we find the same results in human, a new paradigm will be define and will change the way we consider ocular surface therapy and reconstruction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUME L'Institut de Géophysique de l'Université de Lausanne a développé au cours de ces dernières années un système d'acquisition de sismique réflexion multitrace à haute résolution 2D et 3D. L'objectif de cette thèse était de poursuivre ce développement tout améliorant les connaissances de la géologie sous le lac Léman, en étudiant en particulier la configuration des grands accidents sous-lacustres dans la Molasse (Tertiaire) qui forme l'essentiel du substratum des formations quaternaires. En configuration 2D, notre système permet d'acquérir des profils sismiques avec une distance inter-CDP de 1,25 m. La couverture varie entre 6 et 18 selon le nombre de traces et la distance inter-tir. Le canon à air (15/15 eu. in.), offre une résolution verticale de 1,25 ni et une pénétration maximale de 300 m sous le fond de l'eau. Nous avons acquis au total plus de 400 km de sections 2D dans le Grand Lac et le Haut Lac entre octobre 2000 et juillet 2004. Une campagne de sismique 3D a fourni des données au large d'Evian sur une surface de 442,5 m sur 1450 m, soit 0,64 km2. La navigation ainsi que le positionnement des hydrophones et de la source ont été réalisés avec des GPS différentiels. Nous avons utilisé un traitement sismique conventionnel, sans appliquer d'AGC et en utilisant une migration post-stack. L'interprétation du substratum antéquaternaire est basée sur l'identification des sismofaciès, sur leurs relations avec les unités géologiques adjacentes au lac, ainsi que sur quelques données de forages. Nous obtenons ainsi une carte des unités géologiques dans le Grand Lac. Nous précisons la position du chevauchement subalpin entre la ville de Lausanne, sur la rive nord, et le bassin de Sciez, sur la rive sud. Dans la Molasse de Plateau, nous avons identifié les décrochements de Pontarlier et de St. Cergue ainsi que plusieurs failles non reconnues jusqu'ici. Nous avons cartographié les accidents qui affectent la Molasse subalpine ainsi que le plan de chevauchement du flysch sur la Molasse près de la rive sud du lac. Une nouvelle carte tectonique de la région lémanique a ainsi pu être dressée. L'analyse du substratum ne montre pas de failles suggérant une origine tectonique de la cuvette lémanique. Par contre, nous suggérons que la forme du creusement glaciaire, donc de la forme du lac Léman, a été influencée par la présence de failles dans le substratum antéquaternaire. L'analyse des sédiments quaternaires nous a permis de tracer des cartes des différentes interfaces ou unités qui les composent. La carte du toit du substratum antéquaternaire montre la présence de chenaux d'origine glaciaire dont la profondeur maximale atteint la cote -200 ni. Leur pente est dirigée vers le nord-est, à l'inverse du sens d'écoulement actuel des eaux. Nous expliquons cette observation par l'existence de circulations sous-glaciaires d'eau artésienne. Les sédiments glaciaires dont l'épaisseur maximale atteint 150 ni au centre du lac ont enregistré les différentes récurrences glaciaires. Dans la zone d'Evian, nous mettons en évidence la présence de lentilles de sédiments glaciolacustres perchées sur le flanc de la cuvette lémanique. Nous avons corrélé ces unités avec des données de forage et concluons qu'il s'agit du complexe inférieur de la pile sédimentaire d'Evian. Celui-ci, âgé de plus de 30 000 ans, serait un dépôt de Kame associé à un lac périglaciaire. La sismique réflexion 3D permet de préciser l'orientation de l'alimentation en matériel détritique de l'unité. La finesse des images obtenues nous permet également d'établir quels types d'érosion ont affecté certaines unités. Les sédiments lacustres, dont l'épaisseur maximale imagée atteint plus de 225 m et sans doute 400 ni sous le delta du Rhône, indiquent plusieurs mécanismes de dépôts. A la base, une mégaturbidite, épaisse d'une trentaine de mètres en moyenne, s'étend entre l'embouchure de la Dranse et le delta du Rhône. Au-dessus, la décantation des particules en suspension d'origine biologique et détritique fournit l'essentiel des sédiments. Dans la partie orientale du lac, les apports détritiques du Rhône forment un delta qui prograde vers l'ouest en s'imbriquant avec les sédiments déposés par décantation. La structure superficielle du delta a brutalement évolué, probablement à la suite de l'évènement catastrophique du Tauredunum (563 A.D.). Sa trace probable se marque par la présence d'une surface érosive que nous avons cartographiée. Le delta a ensuite changé de géométrie, avec notamment un déplacement des chenaux sous-lacustres. Sur l'ensemble de nos sections sismiques, nous n'observons aucune faille dans les sédiments quaternaires qui attesterait d'une tectonique postglaciaire du substratum. ABSTRACT During the last few years the institute of Geophysics of the University of Lausanne cleveloped a 2D and 3D high-resolution multichannel seismic reflection acquisition system. The objective of the present work was to carry on this development white improving our knowledge of the geology under Lake Geneva, in particular by studying the configuration of the large accidents affecting the Tertiary Molasse that makes up the basement of most Quaternary deposits. In its 2D configuration, our system makes it possible to acquire seismic profiles with a CDP interval of 1.25 m. The fold varies from 6 to 18 depending on the number of traces and the shooting interval. Our air gun (15/15 cu. in.) provides a vertical resolution of 1.25 m and a maximum penetration depth of approximately 300 m under water bottom. We acquired more than 400 km of 2D sections in the Grand Lac and the Haut Lac between October 2000 and July 2004. A 3D seismic survey off the city of Evian provided data on a surface of 442.5 m x 1450 m (0.64 km2). Ship's navigation as well as hydrophone- and source positioning were carried out with differential GPS. The seismic data were processed following a conventional sequence without .applying AGC and using post-stack migration. The interpretation of the pre-Quaternary substratum is based on sismofacies, on their relationships with terrestrial geological units and on some borehole data. We thus obtained a map of the geological units in the Grand Lac. We defined the location of the subalpine thrust from Lausanne, on the north shore, to the Sciez Basin, on the south shore. Within the Molasse de Plateau, we identified the already know Pontarlier and St Cergue transforms Fault as well as faults. We mapped faults that affect subalpine Molasse as well as the thrust fault plane between alpine flysch and Molasse near the lake's south shore. A new tectonic map of the Lake Geneva region could thus be drawn up. The substratum does not show faults indicating a tectonic origin for the Lake Geneva Basin. However, we suggest that the orientation of glacial erosion, and thus the shape of Lake Geneva, vas influenced by the presence of faults in the pre-Quaternary basement. The analysis of Quaternary sediments enabled us to draw up maps of various discontinuities or internal units. The top pre-Quaternary basement map shows channels of glacial origin, the deepest of them reaching an altitude of 200 m a.s.l. The channel's slopes are directed to the North-East, in opposite direction of the present water flow. We explain this observation by the presence of artesian subglacial water circulation. Glacial sediments, the maximum thickness of which reaches 150 m in the central part of the lake, record several glacial recurrences. In the Evian area, we found lenses of glacio-lacustrine sediments set high up on the flank of the Lake Geneva Bassin. We correlated these units with on-land borehole data and concluded that they represent the lower complex of the Evian sedimentary pile. The lower complex is aider than 30 000 years, and it could be a Kame deposit associated with a periglacial lake. Our 3D seismic reflexion survey enables us to specify the supply direction of detrital material in this unit. With detailed seismic images we established how some units were affected by different erosion types. The lacustrine sediments we imaged in Lake Geneva are thicker than 225 m and 400 m or more Linder the Rhone Delta. They indicate several depositional mechanisms. Their base is a major turbidite, thirty meters thick on average, that spreads between the Dranse mouth and the Rhone delta. Above this unit, settling of suspended biological and detrital particles provides most of the sediments. In the eastern part of the lake, detrital contribution from the Rhone builds a delta that progrades to the west and imbricates with the settling sediments. The shallow structure of the Rhone delta abruptly evolved, probably after the catastrophic Tauredunum event (563 A.D.). It probably coincides with an erosive surface that we mapped. As a result, the delta geometry changed, in particular associated with a displacement of water bottom channels. In all our seismic sections, we do not observe fault in the Quaternary sediments that would attest postglacial tectonic activity in the basement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several molecular therapies require the implantation of cells that secrete biotherapeutic molecules and imaging the location and microenvironment of the cellular implant to ascertain its function. We demonstrate noninvasive in vivo magnetic resonance imaging (MRI) of self-assembled microcontainers that are capable of cell encapsulation. Negative contrast was obtained to discern the microcontainer with MRI; positive contrast was obtained in the complete absence of background signal. MRI on a clinical scanner highlights the translational nature of this research. The microcontainers were loaded with cells that were dispersed in an extracellular matrix, and implanted both subcutaneously and in human tumor xenografts in SCID mice. MRI was performed on the implants, and microcontainers retrieved postimplantation showed cell viability both within and proximal to the implant. The microcontainers are characterized by their small size, three dimensionality, controlled porosity, ease of parallel fabrication, chemical and mechanical stability, and noninvasive traceability in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Our objective was to compare two state-of-the-art coronary MRI (CMRI) sequences with regard to image quality and diagnostic accuracy for the detection of coronary artery disease (CAD). SUBJECTS AND METHODS: Twenty patients with known CAD were examined with a navigator-gated and corrected free-breathing 3D segmented gradient-echo (turbo field-echo) CMRI sequence and a steady-state free precession sequence (balanced turbo field-echo). CMRI was performed in a transverse plane for the left coronary artery and a double-oblique plane for the right coronary artery system. Subjective image quality (1- to 4-point scale, with 1 indicating excellent quality) and objective image quality parameters were independently determined for both sequences. Sensitivity, specificity, and accuracy for the detection of significant (> or = 50% diameter) coronary artery stenoses were determined as defined in invasive catheter X-ray coronary angiography. RESULTS: Subjective image quality was superior for the balanced turbo field-echo approach (1.8 +/- 0.9 vs 2.3 +/- 1.0 for turbo field-echo; p < 0.001). Vessel sharpness, signal-to-noise ratio, and contrast-to-noise ratio were all superior for the balanced turbo field-echo approach (p < 0.01 for signal-to-noise ratio and contrast-to-noise ratio). Of the 103 segments, 18% of turbo field-echo segments and 9% of balanced turbo field-echo segments had to be excluded from disease evaluation because of insufficient image quality. Sensitivity, specificity, and accuracy for the detection of significant coronary artery stenoses in the evaluated segments were 92%, 67%, 85%, respectively, for turbo field-echo and 82%, 82%, 81%, respectively, for balanced turbo field-echo. CONCLUSION: Balanced turbo field-echo offers improved image quality with significantly fewer nondiagnostic segments when compared with turbo field-echo. For the detection of CAD, both sequences showed comparable accuracy for the visualized segments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conditions for the analysis of selected doping substances by UHPSFC-MS/MS were optimized to ensure suitable peak shapes and maximized MS responses. A representative mixture of 31 acidic and basic doping agents was analyzed, in both ESI+ and ESI- modes. The best compromise for all compounds in terms of MS sensitivity and chromatographic performance was obtained when adding 2% water and 10mM ammonium formate in the CO2/MeOH mobile phase. Beside mobile phase, the nature of the make-up solvent added for interfacing UHPSFC with MS was also evaluated. Ethanol was found to be the best candidate as it was able to compensate for the negative effect of 2% water addition in ESI- mode and provided a suitable MS response for all doping agents. Sensitivity of the optimized UHPSFC-MS/MS method was finally assessed and compared to the results obtained in conventional UHPLC-MS/MS. Sensitivity was improved by 5-100-fold in UHPSFC-MS/MS vs. UHPLC-MS/MS for 56% of compounds, while only one compound (bumetanide) offered a significantly higher MS response (4-fold) under UHPLC-MS/MS conditions. In the second paper of this series, the optimal conditions for UHPSFC-MS/MS analysis will be employed to screen >100 doping agents in urine matrix and results will be compared to those obtained by conventional UHPLC-MS/MS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Une fois déposé, un sédiment est affecté au cours de son enfouissement par un ensemble de processus, regroupé sous le terme diagenèse, le transformant parfois légèrement ou bien suffisamment pour le rendre méconnaissable. Ces modifications ont des conséquences sur les propriétés pétrophysiques qui peuvent être positives ou négatives, c'est-à-dire les améliorer ou bien les détériorer. Une voie alternative de représentation numérique des processus, affranchie de l'utilisation des réactions physico-chimiques, a été adoptée et développée en mimant le déplacement du ou des fluides diagénétiques. Cette méthode s'appuie sur le principe d'un automate cellulaire et permet de simplifier les phénomènes sans sacrifier le résultat et permet de représenter les phénomènes diagénétiques à une échelle fine. Les paramètres sont essentiellement numériques ou mathématiques et nécessitent d'être mieux compris et renseignés à partir de données réelles issues d'études d'affleurements et du travail analytique effectué. La représentation des phénomènes de dolomitisation de faible profondeur suivie d'une phase de dédolomitisation a été dans un premier temps effectuée. Le secteur concerne une portion de la série carbonatée de l'Urgonien (Barrémien-Aptien), localisée dans le massif du Vercors en France. Ce travail a été réalisé à l'échelle de la section afin de reproduire les géométries complexes associées aux phénomènes diagénétiques et de respecter les proportions mesurées en dolomite. De plus, la dolomitisation a été simulée selon trois modèles d'écoulement. En effet, la dédolomitisation étant omniprésente, plusieurs hypothèses sur le mécanisme de dolomitisation ont été énoncées et testées. Plusieurs phases de dolomitisation per ascensum ont été également simulées sur des séries du Lias appartenant aux formations du groupe des Calcaire Gris, localisées au nord-est de l'Italie. Ces fluides diagénétiques empruntent le réseau de fracturation comme vecteur et affectent préférentiellement les lithologies les plus micritisées. Cette étude a permis de mettre en évidence la propagation des phénomènes à l'échelle de l'affleurement. - Once deposited, sediment is affected by diagenetic processes during their burial history. These diagenetic processes are able to affect the petrophysical properties of the sedimentary rocks and also improve as such their reservoir capacity. The modelling of diagenetic processes in carbonate reservoirs is still a challenge as far as neither stochastic nor physicochemical simulations can correctly reproduce the complexity of features and the reservoir heterogeneity generated by these processes. An alternative way to reach this objective deals with process-like methods, which simplify the algorithms while preserving all geological concepts in the modelling process. The aim of the methodology is to conceive a consistent and realistic 3D model of diagenetic overprints on initial facies resulting in petrophysical properties at a reservoir scale. The principle of the method used here is related to a lattice gas automata used to mimic diagenetic fluid flows and to reproduce the diagenetic effects through the evolution of mineralogical composition and petrophysical properties. This method developed in a research group is well adapted to handle dolomite reservoirs through the propagation of dolomitising fluids and has been applied on two case studies. The first study concerns a mid-Cretaceous rudist and granular platform of carbonate succession (Urgonian Fm., Les Gorges du Nan, Vercors, SE France), in which several main diagenetic stages have been identified. The modelling in 2D is focused on dolomitisation followed by a dédolomitisation stage. For the second study, data collected from outcrops on the Venetian platform (Lias, Mont Compomolon NE Italy), in which several diagenetic stages have been identified. The main one is related to per ascensum dolomitisation along fractures. In both examples, the evolution of the effects of the mimetic diagenetic fluid on mineralogical composition can be followed through space and numerical time and help to understand the heterogeneity in reservoir properties. Carbonates, dolomitisation, dédolomitisation, process-like modelling, lattice gas automata, random walk, memory effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Un système efficace de sismique tridimensionnelle (3-D) haute-résolution adapté à des cibles lacustres de petite échelle a été développé. Dans le Lac Léman, près de la ville de Lausanne, en Suisse, des investigations récentes en deux dimension (2-D) ont mis en évidence une zone de faille complexe qui a été choisie pour tester notre système. Les structures observées incluent une couche mince (<40 m) de sédiments quaternaires sub-horizontaux, discordants sur des couches tertiaires de molasse pentées vers le sud-est. On observe aussi la zone de faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau de la Molasse Subalpine. Deux campagnes 3-D complètes, d?environ d?un kilomètre carré, ont été réalisées sur ce site de test. La campagne pilote (campagne I), effectuée en 1999 pendant 8 jours, a couvert 80 profils en utilisant une seule flûte. Pendant la campagne II (9 jours en 2001), le nouveau système trois-flûtes, bien paramétrés pour notre objectif, a permis l?acquisition de données de très haute qualité sur 180 lignes CMP. Les améliorations principales incluent un système de navigation et de déclenchement de tirs grâce à un nouveau logiciel. Celui-ci comprend un contrôle qualité de la navigation du bateau en temps réel utilisant un GPS différentiel (dGPS) à bord et une station de référence près du bord du lac. De cette façon, les tirs peuvent être déclenchés tous les 5 mètres avec une erreur maximale non-cumulative de 25 centimètres. Tandis que pour la campagne I la position des récepteurs de la flûte 48-traces a dû être déduite à partir des positions du bateau, pour la campagne II elle ont pu être calculées précisément (erreur <20 cm) grâce aux trois antennes dGPS supplémentaires placées sur des flotteurs attachés à l?extrémité de chaque flûte 24-traces. Il est maintenant possible de déterminer la dérive éventuelle de l?extrémité des flûtes (75 m) causée par des courants latéraux ou de petites variations de trajet du bateau. De plus, la construction de deux bras télescopiques maintenant les trois flûtes à une distance de 7.5 m les uns des autres, qui est la même distance que celle entre les lignes naviguées de la campagne II. En combinaison avec un espacement de récepteurs de 2.5 m, la dimension de chaque «bin» de données 3-D de la campagne II est de 1.25 m en ligne et 3.75 m latéralement. L?espacement plus grand en direction « in-line » par rapport à la direction «cross-line» est justifié par l?orientation structurale de la zone de faille perpendiculaire à la direction «in-line». L?incertitude sur la navigation et le positionnement pendant la campagne I et le «binning» imprécis qui en résulte, se retrouve dans les données sous forme d?une certaine discontinuité des réflecteurs. L?utilisation d?un canon à air à doublechambre (qui permet d?atténuer l?effet bulle) a pu réduire l?aliasing observé dans les sections migrées en 3-D. Celui-ci était dû à la combinaison du contenu relativement haute fréquence (<2000 Hz) du canon à eau (utilisé à 140 bars et à 0.3 m de profondeur) et d?un pas d?échantillonnage latéral insuffisant. Le Mini G.I 15/15 a été utilisé à 80 bars et à 1 m de profondeur, est mieux adapté à la complexité de la cible, une zone faillée ayant des réflecteurs pentés jusqu?à 30°. Bien que ses fréquences ne dépassent pas les 650 Hz, cette source combine une pénétration du signal non-aliasé jusqu?à 300 m dans le sol (par rapport au 145 m pour le canon à eau) pour une résolution verticale maximale de 1.1 m. Tandis que la campagne I a été acquise par groupes de plusieurs lignes de directions alternées, l?optimisation du temps d?acquisition du nouveau système à trois flûtes permet l?acquisition en géométrie parallèle, ce qui est préférable lorsqu?on utilise une configuration asymétrique (une source et un dispositif de récepteurs). Si on ne procède pas ainsi, les stacks sont différents selon la direction. Toutefois, la configuration de flûtes, plus courtes que pour la compagne I, a réduit la couverture nominale, la ramenant de 12 à 6. Une séquence classique de traitement 3-D a été adaptée à l?échantillonnage à haute fréquence et elle a été complétée par deux programmes qui transforment le format non-conventionnel de nos données de navigation en un format standard de l?industrie. Dans l?ordre, le traitement comprend l?incorporation de la géométrie, suivi de l?édition des traces, de l?harmonisation des «bins» (pour compenser l?inhomogénéité de la couverture due à la dérive du bateau et de la flûte), de la correction de la divergence sphérique, du filtrage passe-bande, de l?analyse de vitesse, de la correction DMO en 3-D, du stack et enfin de la migration 3-D en temps. D?analyses de vitesse détaillées ont été effectuées sur les données de couverture 12, une ligne sur deux et tous les 50 CMP, soit un nombre total de 600 spectres de semblance. Selon cette analyse, les vitesses d?intervalles varient de 1450-1650 m/s dans les sédiments non-consolidés et de 1650-3000 m/s dans les sédiments consolidés. Le fait que l?on puisse interpréter plusieurs horizons et surfaces de faille dans le cube, montre le potentiel de cette technique pour une interprétation tectonique et géologique à petite échelle en trois dimensions. On distingue cinq faciès sismiques principaux et leurs géométries 3-D détaillées sur des sections verticales et horizontales: les sédiments lacustres (Holocène), les sédiments glacio-lacustres (Pléistocène), la Molasse du Plateau, la Molasse Subalpine de la zone de faille (chevauchement) et la Molasse Subalpine au sud de cette zone. Les couches de la Molasse du Plateau et de la Molasse Subalpine ont respectivement un pendage de ~8° et ~20°. La zone de faille comprend de nombreuses structures très déformées de pendage d?environ 30°. Des tests préliminaires avec un algorithme de migration 3-D en profondeur avant sommation et à amplitudes préservées démontrent que la qualité excellente des données de la campagne II permet l?application de telles techniques à des campagnes haute-résolution. La méthode de sismique marine 3-D était utilisée jusqu?à présent quasi-exclusivement par l?industrie pétrolière. Son adaptation à une échelle plus petite géographiquement mais aussi financièrement a ouvert la voie d?appliquer cette technique à des objectifs d?environnement et du génie civil.<br/><br/>An efficient high-resolution three-dimensional (3-D) seismic reflection system for small-scale targets in lacustrine settings was developed. In Lake Geneva, near the city of Lausanne, Switzerland, past high-resolution two-dimensional (2-D) investigations revealed a complex fault zone (the Paudèze thrust zone), which was subsequently chosen for testing our system. Observed structures include a thin (<40 m) layer of subhorizontal Quaternary sediments that unconformably overlie southeast-dipping Tertiary Molasse beds and the Paudèze thrust zone, which separates Plateau and Subalpine Molasse units. Two complete 3-D surveys have been conducted over this same test site, covering an area of about 1 km2. In 1999, a pilot survey (Survey I), comprising 80 profiles, was carried out in 8 days with a single-streamer configuration. In 2001, a second survey (Survey II) used a newly developed three-streamer system with optimized design parameters, which provided an exceptionally high-quality data set of 180 common midpoint (CMP) lines in 9 days. The main improvements include a navigation and shot-triggering system with in-house navigation software that automatically fires the gun in combination with real-time control on navigation quality using differential GPS (dGPS) onboard and a reference base near the lake shore. Shots were triggered at 5-m intervals with a maximum non-cumulative error of 25 cm. Whereas the single 48-channel streamer system of Survey I requires extrapolation of receiver positions from the boat position, for Survey II they could be accurately calculated (error <20 cm) with the aid of three additional dGPS antennas mounted on rafts attached to the end of each of the 24- channel streamers. Towed at a distance of 75 m behind the vessel, they allow the determination of feathering due to cross-line currents or small course variations. Furthermore, two retractable booms hold the three streamers at a distance of 7.5 m from each other, which is the same distance as the sail line interval for Survey I. With a receiver spacing of 2.5 m, the bin dimension of the 3-D data of Survey II is 1.25 m in in-line direction and 3.75 m in cross-line direction. The greater cross-line versus in-line spacing is justified by the known structural trend of the fault zone perpendicular to the in-line direction. The data from Survey I showed some reflection discontinuity as a result of insufficiently accurate navigation and positioning and subsequent binning errors. Observed aliasing in the 3-D migration was due to insufficient lateral sampling combined with the relatively high frequency (<2000 Hz) content of the water gun source (operated at 140 bars and 0.3 m depth). These results motivated the use of a double-chamber bubble-canceling air gun for Survey II. A 15 / 15 Mini G.I air gun operated at 80 bars and 1 m depth, proved to be better adapted for imaging the complexly faulted target area, which has reflectors dipping up to 30°. Although its frequencies do not exceed 650 Hz, this air gun combines a penetration of non-aliased signal to depths of 300 m below the water bottom (versus 145 m for the water gun) with a maximum vertical resolution of 1.1 m. While Survey I was shot in patches of alternating directions, the optimized surveying time of the new threestreamer system allowed acquisition in parallel geometry, which is preferable when using an asymmetric configuration (single source and receiver array). Otherwise, resulting stacks are different for the opposite directions. However, the shorter streamer configuration of Survey II reduced the nominal fold from 12 to 6. A 3-D conventional processing flow was adapted to the high sampling rates and was complemented by two computer programs that format the unconventional navigation data to industry standards. Processing included trace editing, geometry assignment, bin harmonization (to compensate for uneven fold due to boat/streamer drift), spherical divergence correction, bandpass filtering, velocity analysis, 3-D DMO correction, stack and 3-D time migration. A detailed semblance velocity analysis was performed on the 12-fold data set for every second in-line and every 50th CMP, i.e. on a total of 600 spectra. According to this velocity analysis, interval velocities range from 1450-1650 m/s for the unconsolidated sediments and from 1650-3000 m/s for the consolidated sediments. Delineation of several horizons and fault surfaces reveal the potential for small-scale geologic and tectonic interpretation in three dimensions. Five major seismic facies and their detailed 3-D geometries can be distinguished in vertical and horizontal sections: lacustrine sediments (Holocene) , glaciolacustrine sediments (Pleistocene), Plateau Molasse, Subalpine Molasse and its thrust fault zone. Dips of beds within Plateau and Subalpine Molasse are ~8° and ~20°, respectively. Within the fault zone, many highly deformed structures with dips around 30° are visible. Preliminary tests with 3-D preserved-amplitude prestack depth migration demonstrate that the excellent data quality of Survey II allows application of such sophisticated techniques even to high-resolution seismic surveys. In general, the adaptation of the 3-D marine seismic reflection method, which to date has almost exclusively been used by the oil exploration industry, to a smaller geographical as well as financial scale has helped pave the way for applying this technique to environmental and engineering purposes.<br/><br/>La sismique réflexion est une méthode d?investigation du sous-sol avec un très grand pouvoir de résolution. Elle consiste à envoyer des vibrations dans le sol et à recueillir les ondes qui se réfléchissent sur les discontinuités géologiques à différentes profondeurs et remontent ensuite à la surface où elles sont enregistrées. Les signaux ainsi recueillis donnent non seulement des informations sur la nature des couches en présence et leur géométrie, mais ils permettent aussi de faire une interprétation géologique du sous-sol. Par exemple, dans le cas de roches sédimentaires, les profils de sismique réflexion permettent de déterminer leur mode de dépôt, leurs éventuelles déformations ou cassures et donc leur histoire tectonique. La sismique réflexion est la méthode principale de l?exploration pétrolière. Pendant longtemps on a réalisé des profils de sismique réflexion le long de profils qui fournissent une image du sous-sol en deux dimensions. Les images ainsi obtenues ne sont que partiellement exactes, puisqu?elles ne tiennent pas compte de l?aspect tridimensionnel des structures géologiques. Depuis quelques dizaines d?années, la sismique en trois dimensions (3-D) a apporté un souffle nouveau à l?étude du sous-sol. Si elle est aujourd?hui parfaitement maîtrisée pour l?imagerie des grandes structures géologiques tant dans le domaine terrestre que le domaine océanique, son adaptation à l?échelle lacustre ou fluviale n?a encore fait l?objet que de rares études. Ce travail de thèse a consisté à développer un système d?acquisition sismique similaire à celui utilisé pour la prospection pétrolière en mer, mais adapté aux lacs. Il est donc de dimension moindre, de mise en oeuvre plus légère et surtout d?une résolution des images finales beaucoup plus élevée. Alors que l?industrie pétrolière se limite souvent à une résolution de l?ordre de la dizaine de mètres, l?instrument qui a été mis au point dans le cadre de ce travail permet de voir des détails de l?ordre du mètre. Le nouveau système repose sur la possibilité d?enregistrer simultanément les réflexions sismiques sur trois câbles sismiques (ou flûtes) de 24 traces chacun. Pour obtenir des données 3-D, il est essentiel de positionner les instruments sur l?eau (source et récepteurs des ondes sismiques) avec une grande précision. Un logiciel a été spécialement développé pour le contrôle de la navigation et le déclenchement des tirs de la source sismique en utilisant des récepteurs GPS différentiel (dGPS) sur le bateau et à l?extrémité de chaque flûte. Ceci permet de positionner les instruments avec une précision de l?ordre de 20 cm. Pour tester notre système, nous avons choisi une zone sur le Lac Léman, près de la ville de Lausanne, où passe la faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau et de la Molasse Subalpine. Deux campagnes de mesures de sismique 3-D y ont été réalisées sur une zone d?environ 1 km2. Les enregistrements sismiques ont ensuite été traités pour les transformer en images interprétables. Nous avons appliqué une séquence de traitement 3-D spécialement adaptée à nos données, notamment en ce qui concerne le positionnement. Après traitement, les données font apparaître différents faciès sismiques principaux correspondant notamment aux sédiments lacustres (Holocène), aux sédiments glacio-lacustres (Pléistocène), à la Molasse du Plateau, à la Molasse Subalpine de la zone de faille et la Molasse Subalpine au sud de cette zone. La géométrie 3-D détaillée des failles est visible sur les sections sismiques verticales et horizontales. L?excellente qualité des données et l?interprétation de plusieurs horizons et surfaces de faille montrent le potentiel de cette technique pour les investigations à petite échelle en trois dimensions ce qui ouvre des voies à son application dans les domaines de l?environnement et du génie civil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'objectif principal de ce projet d'extension des prestations, de type Antenne d'intervention dans le milieu pour enfants et adolescents (AIMEA) aux foyers socio-éducatifs pour l'ensemble du canton de Vaud, vise à décloisonner les champs socio-éducatifs et pédopsychiatriques. 64 patients ont fait l'objet d'une évaluation au cours de la phase pilote (après une année de fonctionnement). De plus, une enquête de satisfaction a été effectuée soit à la fin du suivi, soit à la fin de la phase pilote de ce projet (au 31.12.2012). Cette expérience très positive, relevée par une grande majorité des acteurs impliqués dans la prise en charge socio-éducative et pédopsychiatrique des mineurs, suscite un désir d'extension des prestations de type équipe mobile à d'autres structures ou à d'autres types de situations. The main objective of this project about mobile team service extension to the socio-educational home of the whole Vaud canton targets to decompartmentalize the socio-educational and youth-psychiatry domains. 64 patient were assessed during this pilot phase (after one-year functioning). In addition, a satisfaction survey was done either at the end of the follow up or at the end of the pilot phase of the project (31.12.2012). This experience was very positive as highlighted by the vast majority of the person involved in the socio-educational and youth-psychiatric domains taking care of youth. A desire of extension of mobile team service to other institutional structure or other situations was expressed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evidences collected from smartphones users show a growing desire of personalization offered by services for mobile devices. However, the need to accurately identify users' contexts has important implications for user's privacy and it increases the amount of trust, which users are requested to have in the service providers. In this paper, we introduce a model that describes the role of personalization and control in users' assessment of cost and benefits associated to the disclosure of private information. We present an instantiation of such model, a context-aware application for smartphones based on the Android operating system, in which users' private information are protected. Focus group interviews were conducted to examine users' privacy concerns before and after having used our application. Obtained results confirm the utility of our artifact and provide support to our theoretical model, which extends previous literature on privacy calculus and user's acceptance of context-aware technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The decline of malaria and scale-up of rapid diagnostic tests calls for a revision of IMCI. A new algorithm (ALMANACH) running on mobile technology was developed based on the latest evidence. The objective was to ensure that ALMANACH was safe, while keeping a low rate of antibiotic prescription. METHODS: Consecutive children aged 2-59 months with acute illness were managed using ALMANACH (2 intervention facilities), or standard practice (2 control facilities) in Tanzania. Primary outcomes were proportion of children cured at day 7 and who received antibiotics on day 0. RESULTS: 130/842 (15∙4%) in ALMANACH and 241/623 (38∙7%) in control arm were diagnosed with an infection in need for antibiotic, while 3∙8% and 9∙6% had malaria. 815/838 (97∙3%;96∙1-98.4%) were cured at D7 using ALMANACH versus 573/623 (92∙0%;89∙8-94∙1%) using standard practice (p<0∙001). Of 23 children not cured at D7 using ALMANACH, 44% had skin problems, 30% pneumonia, 26% upper respiratory infection and 13% likely viral infection at D0. Secondary hospitalization occurred for one child using ALMANACH and one who eventually died using standard practice. At D0, antibiotics were prescribed to 15∙4% (12∙9-17∙9%) using ALMANACH versus 84∙3% (81∙4-87∙1%) using standard practice (p<0∙001). 2∙3% (1∙3-3.3) versus 3∙2% (1∙8-4∙6%) received an antibiotic secondarily. CONCLUSION: Management of children using ALMANACH improve clinical outcome and reduce antibiotic prescription by 80%. This was achieved through more accurate diagnoses and hence better identification of children in need of antibiotic treatment or not. The building on mobile technology allows easy access and rapid update of the decision chart. TRIAL REGISTRATION: Pan African Clinical Trials Registry PACTR201011000262218.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.