65 resultados para Russian software industry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Several software packages (SWP) and models have been released for quantification of myocardial perfusion (MP). Although they all are validated against something, the question remains how well their values agree. The present analysis focused on cross-comparison of three SWP for MP quantification of 13N-ammonia PET studies. Materials & Methods. 48 rest and stress MP 13N-ammonia PET studies of hypertrophic cardiomyopathy (HCM) patients (Sciagrà et al., 2009) were analysed with three SW packages - Carimas, PMOD, and FlowQuant - by three observers blinded to the results of each other. All SWP implement the one-tissue-compartment model (1TCM, DeGrado et al. 1996), and first two - the two-tissue-compartment model (2TCM, Hutchins et al. 1990) as well. Linear mixed model for the repeated measures was fitted to the data. Where appropriate we used Bland-Altman plots as well. The reproducibility was assessed on global, regional and segmental levels. Intraclass correlation coefficients (ICC), differences between the SWPs and between models were obtained. ICC≥0.75 indicated excellent reproducibility, 0.4≤ICC<0.75 indicated fair to good reproducibility, ICC<0.4 - poor reproducibility (Rosner, 2010). Results. When 1TCM MP values were compared, the SW agreement on global and regional levels was excellent, except for Carimas vs. PMOD at RCA: ICC=0.715 and for PMOD vs. FlowQuant at LCX:ICC=0.745 which were good. In segmental analysis in five segments: 7,12,13, 16, and 17 the agreement between all SWP was excellent; in the remaining 12 segments the agreement varied between the compared SWP. Carimas showed excellent agreement with FlowQuant in 13 segments and good in four - 1, 5, 6, 11: 0.687≤ICCs≤0.73; Carimas had excellent agreement with PMOD in 11 segments, good in five_4, 9, 10, 14, 15: 0.682≤ICCs≤0.737, and poor in segment 3: ICC=0.341. PMOD had excellent agreement with FlowQuant in eight segments and substantial-to-good in nine_1, 2, 3, 5, 6,8-11: 0.585≤ICCs≤0.738. Agreement between Carimas and PMOD for 2TCM was good at a global level: ICC=0.745, excellent at LCX (0.780) and RCA (0.774), good at LAD (0.662); agreement was excellent for ten segments, fair-to-substantial for segments 2, 3, 8, 14, 15 (0.431≤ICCs≤0.681), poor for segments 4 (0.384) and 17 (0.278). Conclusions. The three SWP used by different operators to analyse 13N-ammonia PET MP studies provide results that agree well at a global level, regional levels, and mostly well even at a segmental level. Agreement is better for 1TCM. Poor agreement at segments 4 and 17 for 2TCM needs further clarification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Cet article examine le rôle joué par les normes internationales techniques dans la mondialisation des activités de service. Différentes approches d'économie considèrent que les spécificités des activités de services sont un frein à leur délocalisation, à leur industrialisation et à leur normalisation. A l'opposé de ces approches centrées sur les spécificités des activités de services, les approches d'économie politique internationale mettent en avant l'existence de configurations conflictuelles de pouvoir à l'oeuvre dans l'internationalisation des activités de services et ce, au-delà des limites sectorielles et nationales. Cet article examine le cas du secteur des centres d'appels et, plus généralement, celui de la sous-traitance des services aux entreprises (BPO) en Inde. Nos résultats suggèrent que les normes techniques sont importantes dans le secteur étudié, alors même que ces types de services sont conventionnellement identifiés comme étant peu susceptibles d'être soumis à des normes. Une perspective d'économie politique sur la normalisation des activités de service souligne comment la problématique du pouvoir investit la normalisation technique d'une dimension plus progressive à travers les thématiques du "travailleur", du "consommateur", ou de "l'environnement". Abstract This paper explores the role of international standards in the much-debated globalisation of the service economy. Various strands of economic analyses consider that core attributes of services affect their ability to be reliably delocalised, industrialised, and standardised. In contrast, international political economy approaches draw attention to power configurations supporting conflicting use of standards across industries and nations. The paper examines the case of the rising Indian service industry in customer centres and business process outsourcing to probe these opposing views. Our findings suggest that standards matter in types of services that conventional economic analyses identify as unlikely to be standardised, and that the standards used in the Indian BPO industry are widely accepted. Despite little conflict in actual definitions of market requirements, an international political economy perspective on service standardisation highlights the importance of potential power issues related to workers', consumers', and environmental concerns likely to be included in more progressive forms of standardisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.