206 resultados para Purity of blood


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Control of blood pressure (BP) remains a major challenge in primary care. Innovative interventions to improve BP control are therefore needed. By updating and combining data from 2 previous systematic reviews, we assess the effect of pharmacist interventions on BP and identify potential determinants of heterogeneity. METHODS AND RESULTS: Randomized controlled trials (RCTs) assessing the effect of pharmacist interventions on BP among outpatients with or without diabetes were identified from MEDLINE, EMBASE, CINAHL, and CENTRAL databases. Weighted mean differences in BP were estimated using random effect models. Prediction intervals (PI) were computed to better express uncertainties in the effect estimates. Thirty-nine RCTs were included with 14 224 patients. Pharmacist interventions mainly included patient education, feedback to physician, and medication management. Compared with usual care, pharmacist interventions showed greater reduction in systolic BP (-7.6 mm Hg, 95% CI: -9.0 to -6.3; I(2)=67%) and diastolic BP (-3.9 mm Hg, 95% CI: -5.1 to -2.8; I(2)=83%). The 95% PI ranged from -13.9 to -1.4 mm Hg for systolic BP and from -9.9 to +2.0 mm Hg for diastolic BP. The effect tended to be larger if the intervention was led by the pharmacist and was done at least monthly. CONCLUSIONS: Pharmacist interventions - alone or in collaboration with other healthcare professionals - improved BP management. Nevertheless, pharmacist interventions had differential effects on BP, from very large to modest or no effect; and determinants of heterogeneity could not be identified. Determining the most efficient, cost-effective, and least time-consuming intervention should be addressed with further research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last issue of Blood Pressure Monitoring, (James K, Dolan E, O'Brien E. Making ambulatory blood pressure monitoring accessible in pharmacies. Blood Press Monit 2014;19:134-139) elegantly reported for the first time the characteristics of patients attending pharmacies for ambulatory blood pressure measurement (ABPM) and showed that they were similar to those undergoing ABPM through primary care practices. The authors concluded that pharmacies could be a valuable resource to perform ABPM. In the continuity of this study, we would like to emphasize the results of recent studies as well as recommenda-tions of pharmacist involvement in the management of hypertension, more specifically in a team approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Résumé : Un nombre croissant de cas de malaria chez les voyageurs et migrants a été rapporté. Bien que l'analyse microscopique des frottis sanguins reste traditionnellement l'outil diagnostic de référence, sa fiabilité dépend considérablement de l'expertise de l'examinateur, pouvant elle-même faire défaut sous nos latitudes. Une PCR multiplex en temps réel a donc été développée en vue d'une standardisation du diagnostic. Un ensemble d'amorces génériques ciblant une région hautement conservée du gène d'ARN ribosomial 18S du genre Plasmodium a tout d'abord été conçu, dont le polymorphisme du produit d'amplification semblait suffisant pour créer quatre sondes spécifiques à l'espèce P. falciparum, P. malariae, P. vivax et P. ovale. Ces sondes utilisées en PCR en temps réel se sont révélées capables de détecter une seule copie de plasmide de P. falciparum, P. malariae, P. vivax et P. ovale spécifiquement. La même sensibilité a été obtenue avec une sonde de screening pouvant détecter les quatre espèces. Quatre-vingt-dix-sept échantillons de sang ont ensuite été testés, dont on a comparé la microscopie et la PCR en temps réel pour 66 (60 patients) d'entre eux. Ces deux méthodes ont montré une concordance globale de 86% pour la détection de plasmodia. Les résultats discordants ont été réévalués grâce à des données cliniques, une deuxième expertise microscopique et moléculaire (laboratoire de Genève et de l'Institut Suisse Tropical de Bâle), ainsi qu'à l'aide du séquençage. Cette nouvelle analyse s'est prononcé en faveur de la méthode moléculaire pour tous les neuf résultats discordants. Sur les 31 résultats positifs par les deux méthodes, la même réévaluation a pu donner raison 8 fois sur 9 à la PCR en temps réel sur le plan de l'identification de l'espèce plasmodiale. Les 31 autres échantillons ont été analysés pour le suivi de sept patients sous traitement antimalarique. Il a été observé une baisse rapide du nombre de parasites mesurée par la PCR en temps réel chez six des sept patients, baisse correspondant à la parasitémie déterminée microscopiquement. Ceci suggère ainsi le rôle potentiel de la PCR en temps réel dans le suivi thérapeutique des patients traités par antipaludéens. Abstract : There have been reports of increasing numbers of cases of malaria among migrants and travelers. Although microscopic examination of blood smears remains the "gold standard" in diagnosis, this method suffers from insufficient sensitivity and requires considerable expertise. To improve diagnosis, a multiplex real-time PCR was developed. One set of generic primers targeting a highly conserved region of the 18S rRNA gene of the genus Plasmodium was designed; the primer set was polymorphic enough internally to design four species-specific probes for P. falciparum, P. vivax, P. malarie, and P. ovale. Real-time PCR with species-specific probes detected one plasmid copy of P. falciparum, P. vivax, P. malariae, and P. ovale specifically. The same sensitivity was achieved for all species with real-time PCR with the 18S screening probe. Ninety-seven blood samples were investigated. For 66 of them (60 patients), microscopy and real-time PCR results were compared and had a crude agreement of 86% for the detection of plasmodia. Discordant results were reevaluated with clinical, molecular, and sequencing data to resolve them. All nine discordances between 18S screening PCR and microscopy were resolved in favor of the molecular method, as were eight of nine discordances at the species level for the species-specific PCR among the 31 samples positive by both methods. The other 31 blood samples were tested to monitor the antimalaria treatment in seven patients. The number of parasites measured by real-time PCR fell rapidly for six out of seven patients in parallel to parasitemia determined microscopically. This suggests a role of quantitative PCR for the monitoring of patients receiving antimalaria therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of devices, the additional information and indices that ABPM devices may provide, and the software requirements.At a practical level, the paper details the requirements for using ABPM in clinical practice, editing considerations, the number of measurements required, and the circumstances, such as obesity and arrhythmias, when particular care needs to be taken when using ABPM.The clinical indications for ABPM, among which white-coat phenomena, masked hypertension, and nocturnal hypertension appear to be prominent, are outlined in detail along with special considerations that apply in certain clinical circumstances, such as childhood, the elderly and pregnancy, and in cardiovascular illness, examples being stroke and chronic renal disease, and the place of home measurement of blood pressure in relation to ABPM is appraised.The role of ABPM in research circumstances, such as pharmacological trials and in the prediction of outcome in epidemiological studies is examined and finally the implementation of ABPM in practice is considered in relation to the issue of reimbursement in different countries, the provision of the technique by primary care practices, hospital clinics and pharmacies, and the growing role of registries of ABPM in many countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Children with elevated blood pressure are at risk of being hypertensive in adulthood and of developing complications such as ventricular hypertrophy. Obesity is a cause of hypertension. Because the prevalence of obesity is increasing, some authors argue that the systematic screening for hypertension in children and adolescents is justified for early prevention and treatment. Sex, age and height all influence children's blood pressure. When elevated blood pressure is identified, complementary investigations and treatment might be necessary. However, due to the difficulties of obtaining a valid estimate of blood pressure, to the moderate tracking of blood pressure from childhood to adulthood, and the rarity of hypertension cases in childhood, the usefulness of systematic screening of hypertension during childhood is still controversial. Un enfant dont la pression artérielle est élevée a un risque accru d'être hypertendu à l'âge adulte et de présenter des complications telles que l'hypertrophie ventriculaire gauche. L'augmentation de la prévalence de l'obésité justifierait selon certains auteurs le dépistage systématique de l'hypertension dès le plus jeune âge afin d'instaurer des mesures préventives ou curatives précoces. Les normes de pression dépendent du sexe, de l'âge et de la taille de l'enfant. En cas de pression élevée, des investigations complémentaires, voire un traitement, peuvent être indiqués. Au vu des difficultés pour obtenir une mesure fiable, des incertitudes entachant la valeur pronostique d'une pression artérielle élevée et de la rareté des cas d'hypertension, il n'y a pas de consensus sur l'utilité du dépistage systématique de l'hypertension durant l'enfance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Carbon monoxide (CO) poisoning is one of the mostcommon causes of fatal poisoning. Symptoms of CO poisoning arenonspecific and the documentation of elevated carboxyhemoglobin(HbCO) levels in arterial blood sample is the only standard ofconfirming suspected exposure. The treatment of CO poisoning requiresnormobaric or hyperbaric oxygen therapy, according to the symptomsand HbCO levels. A new device, the Rad-57 pulse CO-oximeter allowsnoninvasive transcutaneous measurement of blood carboxyhemoglobinlevel (SpCO) by measurement of light wavelength absorptions.Methods: Prospective cohort study with a sample of patients, admittedbetween October 2008 - March 2009 and October 2009 - March 2010,in the emergency services (ES) of a Swiss regional hospital and aSwiss university hospital (Burn Center). In case of suspected COpoisoning, three successive noninvasive measurements wereperformed, simultaneously with one arterial blood HbCO test. A controlgroup includes patients admitted in the ES for other complaints (cardiacinsufficiency, respiratory distress, acute renal failure), but necessitatingarterial blood testing. Informed consent was obtained from all patients.The primary endpoint was to assess the agreement of themeasurements made by the Rad-57 (SpCO) and the blood levels(HbCO).Results: 50 patients were enrolled, among whom 32 were admittedfor suspected CO poisoning. Baseline demographic and clinicalcharacteristics of patients are presented in table 1. The median age was37.7 ans ± 11.8, 56% being male. Median laboratory carboxyhemoglobinlevels (HbCO) were 4.25% (95% IC 0.6-28.5) for intoxicated patientsand 1.8% (95% IC 1.0-5.3) for control patients. Only five patientspresented with HbCO levels >= 15%. The results disclose relatively faircorrelations between the SpCO levels obtained by the Rad-57 and thestandard HbCO, without any false negative results. However, theRad-57 tend to under-estimate the value of SpCO for patientsintoxicated HbCO levels >10% (fig. 1).Conclusion: Noninvasive transcutaneous measurement of bloodcarboxyhemoglobin level is easy to use. The correlation seems to becorrect for low to moderate levels (<15%). For higher values, weobserve a trend of the Rad-57 to under-estimate the HbCO levels. Apartfrom this potential limitation and a few cases of false-negative resultsdescribed in the literature, the Rad-57 may be useful for initial triageand diagnosis of CO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glucocorticoids affect physiology and behaviour, reproduction and potentially sexual selection as well. Shortterm and moderate glucocorticoid elevations are suggested to be adaptive, and prolonged and high elevations may be extremely harmful. This suggests that optimal reproductive strategies, and thus sexual selection, may be dose dependent. Here, we investigate effects of moderate and high elevations of blood corticosterone levels on intra- and intersexual behaviour and mating success of male common lizards Lacerta vivipara. Females showed less interest and more aggressive behaviour towards high corticosterone males and blood corticosterone levels affected male reproductive strategy. Males of moderate and high corticosterone elevations, compared with Control males, showed increased interest (i.e., higher number of chases, tongue extrusions, and approaches) towards females and high corticosterone males initiated more copulation attempts. However, neither increased male interest nor increased copulation attempts resulted in more copulations. This provides evidence for a best-of-a-bad-job strategy, where males with higher corticosterone levels compensated for reduced female interest and increased aggressive female behaviour directed towards them, by showing higher interest and by conducting more copulation attempts. Blood corticosterone levels affected intrasexual selection as well since moderate corticosterone levels positively affected male dominance, but dominance did not affect mating success. These findings underline the importance of female mate choice and are in line with adaptive compensatory behaviours of males. They further show that glucocorticoid effects on behaviour are dose dependent and that they have important implications for sexual selection and social interactions, and might potentially affect Darwinian fitness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A second collaborative exercise on RNA/DNA co-analysis for body fluid identification and STR profiling was organized by the European DNA Profiling Group (EDNAP). Six human blood stains, two blood dilution series (5-0.001 μl blood) and, optionally, bona fide or mock casework samples of human or non-human origin were analyzed by the participating laboratories using a RNA/DNA co-extraction or solely RNA extraction method. Two novel mRNA multiplexes were used for the identification of blood: a highly sensitive duplex (HBA, HBB) and a moderately sensitive pentaplex (ALAS2, CD3G, ANK1, SPTB and PBGD). The laboratories used different chemistries and instrumentation. All of the 18 participating laboratories were able to successfully isolate and detect mRNA in dried blood stains. Thirteen laboratories simultaneously extracted RNA and DNA from individual stains and were able to utilize mRNA profiling to confirm the presence of blood and to obtain autosomal STR profiles from the blood stain donors. The positive identification of blood and good quality DNA profiles were also obtained from old and compromised casework samples. The method proved to be reproducible and sensitive using different analysis strategies. The results of this collaborative exercise involving a RNA/DNA co-extraction strategy support the potential use of an mRNA based system for the identification of blood in forensic casework that is compatible with current DNA analysis methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Millions of blood products are transfused every year; many lives are thus directly concerned by transfusion. The three main labile blood products used in transfusion are erythrocyte concentrates, platelet concentrates and fresh frozen plasma. Each of these products has to be stored according to its particular components. However, during storage, modifications or degradation of those components may occur, and are known as storage lesions. Thus, biomarker discovery of in vivo blood aging as well as in vitro labile blood products storage lesions is of high interest for the transfusion medicine community. Pre-analytical issues are of major importance in analyzing the various blood products during storage conditions as well as according to various protocols that are currently used in blood banks for their preparations. This paper will review key elements that have to be taken into account in the context of proteomic-based biomarker discovery applied to blood banking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values <0.040). Similar inverse associations were observed for paraxanthine and theophylline. Adjusted night-time systolic blood pressure in the first (lowest), second, third, and fourth (highest) quartile of paraxanthine urinary excretions were 110.3, 107.3, 107.3, and 105.1 mm Hg, respectively (P trend <0.05). No associations of urinary excretions with diastolic blood pressure were generally found, and theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To investigate the functional role of different alpha1-adrenergic receptor (alpha1-AR) subtypes in vivo, we have applied a gene targeting approach to create a mouse model lacking the alpha1b-AR (alpha1b-/-). Reverse transcription-PCR and ligand binding studies were combined to elucidate the expression of the alpha1-AR subtypes in various tissues of alpha1b +/+ and -/- mice. Total alpha1-AR sites were decreased by 98% in liver, 74% in heart, and 42% in cerebral cortex of the alpha1b -/- as compared with +/+ mice. Because of the large decrease of alpha1-AR in the heart and the loss of the alpha1b-AR mRNA in the aorta of the alpha1b-/- mice, the in vivo blood pressure and in vitro aorta contractile responses to alpha1-agonists were investigated in alpha1b +/+ and -/- mice. Our findings provide strong evidence that the alpha1b-AR is a mediator of the blood pressure and the aorta contractile responses induced by alpha1 agonists. This was demonstrated by the finding that the mean arterial blood pressure response to phenylephrine was decreased by 45% in alpha1b -/- as compared with +/+ mice. In addition, phenylephrine-induced contractions of aortic rings also were decreased by 25% in alpha1b-/- mice. The alpha1b-AR knockout mouse model provides a potentially useful tool to elucidate the functional specificity of different alpha1-AR subtypes, to better understand the effects of adrenergic drugs, and to investigate the multiple mechanisms involved in the control of blood pressure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The persistence of high blood pressure under antihypertensive treatment (resistant hypertension) entails an increased cardiovascular risk. It occurs in three of ten treated hypertensive patients, and has several possible contributing factors, notably insufficient therapeutic adherence. There are a number of ways to evaluate whether patients take their medication as prescribed. These include interviewing the patient, pill counting, prescription follow-up, assay of drugs in blood or urine, and use of electronic pill dispensers. None is perfect. However, the essential is to discuss with the patient the importance of complying with the treatment as soon as it is prescribed for the first time, and not waiting for the appearance of resistant hypertension. The measurement of blood pressure outside the medical office and the monitoring of adherence may help to identify patients in whom hypertension is truly resistant and so to tailor the measures required to improve the control of blood pressure in the most appropriate manner.