160 resultados para Power Doppler ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The suprascapular nerve (SSN) block is frequently performed for different shoulder pain conditions and for perioperative and postoperative pain control after shoulder surgery. Blind and image-guided techniques have been described, all of which target the nerve within the supraspinous fossa or at the suprascapular notch. This classic target point is not always ideal when ultrasound (US) is used because it is located deep under the muscles, and hence the nerve is not always visible. Blocking the nerve in the supraclavicular region, where it passes underneath the omohyoid muscle, could be an attractive alternative. METHODS: In the first step, 60 volunteers were scanned with US, both in the supraclavicular and the classic target area. The visibility of the SSN in both regions was compared. In the second step, 20 needles were placed into or immediately next to the SSN in the supraclavicular region of 10 cadavers. The accuracy of needle placement was determined by injection of dye and following dissection. RESULTS: In the supraclavicular region of volunteers, the nerve was identified in 81% of examinations (95% confidence interval [CI], 74%-88%) and located at a median depth of 8 mm (interquartile range, 6-9 mm). Near the suprascapular notch (supraspinous fossa), the nerve was unambiguously identified in 36% of examinations (95% CI, 28%-44%) (P < 0.001) and located at a median depth of 35 mm (interquartile range, 31-38 mm; P < 0.001). In the cadaver investigation, the rate of correct needle placement of the supraclavicular approach was 95% (95% CI, 86%-100%). CONCLUSIONS: Visualization of the SSN with US is better in the supraclavicular region as compared with the supraspinous fossa. The anatomic dissections confirmed that our novel supraclavicular SSN block technique is accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We studied the value of ultrasound (US) to define shoulder pathology and guide local steroid injection in comparison with a standard injection in the management of the acute painful shoulder. METHODS: Seventy consecutive patients with acute shoulder pain were assessed clinically and by US. Patients were randomized to receive either a standard subacromial infiltration of 7 mg of betamethasone or a US-guided injection according to the US diagnosis. Follow-up evaluations were performed by an independent assessor who was blinded to the results of the initial US and clinical assessments. RESULTS: Sixty-seven patients completed the study. Both groups showed a significant reduction in both daytime and night pain compared to baseline. The US injection group had significantly less pain at rest at 2 and 6 weeks (NRS: 1.6 vs 3.3, P<0.005; 3 vs 4.2, P<0.04). The percentage of good responders was significantly higher in US group at 2 weeks, (81% vs 54%, P<0.005) and 6 weeks (64% vs 38%, P<0.05). At 2 and 6 weeks, responder rate and activity pain scores as well as Constant score were in favour of US, though did not reach statistical significance. CONCLUSION: Local steroid injection for shoulder pain leads to significant improvements in pain and function for up to 12 weeks. An US examination to define the origin of shoulder pain as well as to guide injection provides significant additional benefits for up to 6 weeks. We recommend routine US examination as part of the management of acute shoulder pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test the ability of a novel phase-shifting medium (PSM) to provide sustained distension of the uterine cavity and produce saline infusion sonography (SIS)-like images in a simplified contrast ultrasound procedure. DESIGN: Prospective pilot feasibility trial of a new diagnostic procedure, contrast ultrasound. SETTING: Clinical reproductive endocrine and infertility unit of regional teaching hospital. PATIENT(S): Twenty-six asymptomatic infertile women (group I) and 27 women presenting with dysfunctional uterine bleeding (DUB) who were scheduled for exploratory surgery (group II). INTERVENTION(S): All women who were temporarily on oral contraceptive first had a regular pelvic ultrasound followed by the intrauterine instillation of up to 3 mL PSM, using a regular insemination catheter, after which all instruments were removed and a regular ultrasound was performed again. RESULT(S): In all 53 women, intrauterine instillation of 1-3 mL PSM resulted in a 3-7 mm uterine distension, sufficient to produce SIS-like images of the uterine cavity that lasted 7-10 min. Contrast ultrasound revealed an endometrial polyp in 3 asymptomatic women of group I. In group II. 12 of 14 women (86%) whose vaginal ultrasound were positive or dubious had positive findings with contrast ultrasound; 9 of 12 patients whose vaginal ultrasounds were negative also had positive contrast ultrasound findings. All the positive and negative findings of contrast ultrasound made in group II were confirmed anatomically (sensitivity and specificity of 100%), whereas the correlation for standard vaginal ultrasound was markedly lower at 57.1% and 85.7%, respectively. Most patients (46 of 53) reported no discomfort during or after the procedure, and 7 women described the procedure as mildly uncomfortable. CONCLUSION(S): Contrast ultrasound, a novel simple diagnostic procedure conducted after intrauterine instillation of 1-3 mL PSM using a simple plastic catheter, delivered SIS-quality images in asymptomatic (group I) and symptomatic (group II) patients while retaining the simplicity of standard ultrasound. We therefore foresee broad application of contrast ultrasound for sensitive and specific assessment for uterine pathologies in the physician's office.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Extension of retinoblastoma cells into the posterior chamber is a criterion for group E according to the international classification of intraocular retinoblastoma. Currently, the anterior extension of retinoblastoma is based on the presence of tumour cells in the anterior chamber assessed by biomicroscopy. AIM: To determine the value of ultrasound biomicroscopy (UBM) in the assessment of posterior chamber involvement in advanced retinoblastoma. METHODS: Retrospective review of all retinoblastoma cases enucleated at the Jules Gonin Eye Hospital from January 1996 to December 2009 for which UBM (35 MHz) evaluation was available. The patients' records were reviewed for patient and tumour features and histopathological findings. UBM findings were compared with histopathological features. RESULTS: UBM documentation was available in 31 cases. Retinoblastoma was detected by UBM in the posterior chamber in 18 cases and was absent in 13 cases while histopathological analysis demonstrated its presence in the posterior chamber in 22 cases and its absence in 9 cases. Among the 18 UBM-positive cases, 7 had biomicroscopic detectable involvement of the anterior chamber. There was a significant correlation between echodensities consistent with retinoblastoma on UBM in the posterior chamber and histopathological tumorous involvement of the posterior chamber (p=0.0001). The sensitivity of UBM in the assessment of posterior chamber invasion by retinoblastoma was 81% and the specificity was 100%. CONCLUSION: In selected cases of advanced retinoblastoma, UBM appears to represent a valuable tool in the precise evaluation of anterior extension of disease, with good sensitivity and specificity for the assessment of posterior chamber involvement. UBM may provide useful criteria governing the indication for enucleation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decreasing perinatal morbidity and mortality is one of the main goals of obstetrics. Prognosis of preterm births depends on gestational age and birthweight. Multidisciplinary management is discussed with the parents according to these two parameters. In other circumstances, a suspected macrosomy will influence the management of the last weeks of pregnancy. Induction of labor or Cesarean delivery will be considered to avoid shoulder dystocia, brachial plexus injury or perinatal asphyxia. Birthweight needs to be estimated with accuracy, and this article describes the efficiency of various ultrasound weight estimation formulae for small and large fetuses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative ultrasound of bone is a promising method for bone assessment: radiation-free, portable and predictive of hip fracture. Its portability allowed us to study the relationships between ultrasonic parameters of bone with age and with non-vertebral fractures in elderly women living in 19 nursing homes. Broadband ultrasound attenuation (BUA) and speed of sound (SOS) of the calcaneus were measured (and the stiffness index calculated) in a sample of 270 institutionalized women, aged 85 +/- 7 years, using an Achilles bone densitometer (Lunar). The effects of age, history of non-vertebral and non-traumatic fractures, body mass index, triceps skinfold and arm circumference were assessed on BUA, SOS and stiffness index. Furthermore, to evaluate longitudinally the influence of aging on the ultrasound parameters of bone, 60 subjects from the same group had a second ultrasound measurement after 1 year. The cross-sectional analysis of the data on all 270 women showed a significant decrease (p < 0.001) with age in BUA, SOS and stiffness index (-0.47%, -0.06%, and -1.01% respectively per year). In the 94 women, (35%) with a history of previous non-vertebral fractures, ultrasound parameters were significantly lower (p < 0.0001) than in the 176 women with no history of fracture (-8.3% for BUA, -1.3% for SOS, -18.9% for stiffness index). In contrast, there was no significant difference in anthropometric measurements between the groups with and without previous non-vertebral fractures, although the measurements decreased significantly with age. In the longitudinal study, repeated quantitative ultrasound after 11.4 +/- 0.8 months showed no significant decrease in BUA (-1%) but a significant decrease in SOS (-0.3%, p < 0.0001) and in stiffness index (-3.6%, p < 0.0002). In conclusion, quantitative ultrasound of the calcaneus measures properties of bone which continue to decline in institutionalized elderly women, and is able to discriminate women with previous non-vertebral fractures.