91 resultados para Polyethylene glycol.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Barbiturates are regularly used as an anesthetic for animal experimentation and clinical procedures and are frequently provided with solubilizing compounds, such as ethanol and propylene glycol, which have been reported to affect brain function and, in the case of (1)H NMR experiments, originate undesired resonances in spectra affecting the quantification. As an alternative, thiopental can be administrated without any solubilizing agents. The aim of the study was to investigate the effect of deep thiopental anesthesia on the neurochemical profile consisting of 19 metabolites and on glucose transport kinetics in vivo in rat cortex compared with alpha-chloralose using localized (1)H NMR spectroscopy. Thiopental was devoid of effects on the neurochemical profile, except for the elevated glucose at a given plasma glucose level resulting from thiopental-induced depression of glucose consumption at isoelectrical condition. Over the entire range of plasma glucose levels, steady-state glucose concentrations were increased on average by 48% +/- 8%, implying that an effect of deep thiopental anesthesia on the transport rate relative to cerebral glucose consumption ratio was increased by 47% +/- 8% compared with light alpha-chloralose-anesthetized rats. We conclude that the thiopental-induced isoelectrical condition in rat cortex significantly affected glucose contents by depressing brain metabolism, which remained substantial at isoelectricity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The posterior inclination of the tibial component is an important factor that can affect the success of total knee arthroplasty. It can reduce the posterior impingement and thus increase the range of flexion, but it may also induce instability in flexion, anterior impingement between the polyethylene of postero-stabilizing knee prosthesis, and anterior conflict with the cortical bone and the stem. Although the problem is identified, there is still a debate on the ideal inclination angle and the surgical technique to avoid an excessive posterior inclination. The aim of this study was to predict the effect of a posterior inclination of the tibial component on the contact pattern on the tibial insert, using a numerical musculoskeletal model of the knee joint. Methods: A 3D finite element model of the knee joint was developed to simulate an active and loaded squat movement after total knee arthroplasty. Flexion was actively controlled by the quadriceps muscle and muscle activations were estimated from EMG data and were synchronized by a feedback algorithm. Two inclinations of the tibial tray were considered: a posterior inclination of 0° or 10°. During the entire range of flexion, the following quantities were calculated: the tibiofemoral and patello-femoral contact force, and the contact pattern on polyethylene insert. The antero-posterior displacement of the contact pattern was also measured. Abaqus 6.7 was used for all analyses. Results: The tibio-femoral and patello-femoral contact forces increased during flexion and reached respectively 4 and 7 BW (bodyweight) at 90° of flexion. They were slightly affected by the inclination of the tibial tray. Without posterior inclination, the contact pattern on the tibial insert remained centered. The contact pressure was lower than 5 MPa below 60° of flexion, but exceeded 20 MPa at 90° of flexion. The posterior inclination displaced the contact point posteriorly by 2 to 4 mm. Conclusion: The inclination of the tibial tray displaced the contactpattern towards the posterior border of the tibial insert. However, even for 10° of inclination, the contact center remained far from the posterior border (12 mm). There was no instability predicted for this movement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two types of hydrogel microspheres have been developed. Fast ionotropic gelation of sodium alginate (Na-alg) in the presence of calcium ions was combined with slow covalent cross-linking of poly(ethylene glycol) (PEG) derivatives. For the first type, the fast obtainable Ca-alg hydrogel served as spherical matrix for the simultaneously occurring covalent cross-linking of multi-arm PEG derivative. A two-component interpenetrating network was formed in one step upon extruding the mixture of the two polymers into the gelation bath. For the second type, heterobifunctional PEG was grafted onto Na-alg prior to gelation. Upon extrusion of the polymer solution into the gelation bath, fast Ca-alg formation ensured the spherical shape and was accompanied by cross-linker-free covalent cross-linking of the PEG side chains. Thus, one-component hydrogel microspheres resulted. We present the physical properties of the hydrogel microspheres and demonstrate the feasibility of cell microencapsulation for both types of polymer networks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent findings suggest an association between exposure to cleaning products and respiratory dysfunctions including asthma. However, little information is available about quantitative airborne exposures of professional cleaners to volatile organic compounds deriving from cleaning products. During the first phases of the study, a systematic review of cleaning products was performed. Safety data sheets were reviewed to assess the most frequently added volatile organic compounds. It was found that professional cleaning products are complex mixtures of different components (compounds in cleaning products: 3.5 ± 2.8), and more than 130 chemical substances listed in the safety data sheets were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%), skin (50%) and by ingestion (60%) were the most reported. Monoethanolamine, a strong irritant and known to be involved in sensitizing mechanisms as well as allergic reactions, is frequently added to cleaning products. Monoethanolamine determination in air has traditionally been difficult and air sampling and analysis methods available were little adapted for personal occupational air concentration assessments. A convenient method was developed with air sampling on impregnated glass fiber filters followed by one step desorption, gas chromatography and nitrogen phosphorous selective detection. An exposure assessment was conducted in the cleaning sector, to determine airborne concentrations of monoethanolamine, glycol ethers, and benzyl alcohol during different cleaning tasks performed by professional cleaning workers in different companies, and to determine background air concentrations of formaldehyde, a known indoor air contaminant. The occupational exposure study was carried out in 12 cleaning companies, and personal air samples were collected for monoethanolamine (n=68), glycol ethers (n=79), benzyl alcohol (n=15) and formaldehyde (n=45). All but ethylene glycol mono-n-butyl ether air concentrations measured were far below (<1/10) of the Swiss eight hours occupational exposure limits, except for butoxypropanol and benzyl alcohol, where no occupational exposure limits were available. Although only detected once, ethylene glycol mono-n-butyl ether air concentrations (n=4) were high (49.5 mg/m3 to 58.7 mg/m3), hovering at the Swiss occupational exposure limit (49 mg/m3). Background air concentrations showed no presence of monoethanolamine, while the glycol ethers were often present, and formaldehyde was universally detected. Exposures were influenced by the amount of monoethanolamine in the cleaning product, cross ventilation and spraying. The collected data was used to test an already existing exposure modeling tool during the last phases of the study. The exposure estimation of the so called Bayesian tool converged with the measured range of exposure the more air concentrations of measured exposure were added. This was best described by an inverse 2nd order equation. The results suggest that the Bayesian tool is not adapted to predict low exposures. The Bayesian tool should be tested also with other datasets describing higher exposures. Low exposures to different chemical sensitizers and irritants should be further investigated to better understand the development of respiratory disorders in cleaning workers. Prevention measures should especially focus on incorrect use of cleaning products, to avoid high air concentrations at the exposure limits. - De récentes études montrent l'existence d'un lien entre l'exposition aux produits de nettoyages et les maladies respiratoires telles que l'asthme. En revanche, encore peu d'informations sont disponibles concernant la quantité d'exposition des professionnels du secteur du nettoyage aux composants organiques volatiles provenant des produits qu'ils utilisent. Pendant la première phase de cette étude, un recueil systématique des produits professionnels utilisés dans le secteur du nettoyage a été effectué. Les fiches de données de sécurité de ces produits ont ensuite été analysées, afin de répertorier les composés organiques volatiles les plus souvent utilisés. Il a été mis en évidence que les produits de nettoyage professionnels sont des mélanges complexes de composants chimiques (composants chimiques dans les produits de nettoyage : 3.5 ± 2.8). Ainsi, plus de 130 substances listées dans les fiches de données de sécurité ont été retrouvées dans les 105 produits répertoriés. Les principales classes de substances chimiques identifiées étaient les parfums, les éthers de glycol, les agents de surface et les solvants; dans une moindre mesure, les phosphates, les sels, les détergents, les régulateurs de pH, les acides et les bases ont été identifiés. Plus de 75% des produits répertoriés contenaient des substances décrites comme irritantes (Xi), 64% nuisibles (Xn) et 28% corrosives (C). Les risques pour les yeux (59%), la peau (50%) et par ingestion (60%) était les plus mentionnés. La monoéthanolamine, un fort irritant connu pour être impliqué dans les mécanismes de sensibilisation tels que les réactions allergiques, est fréquemment ajouté aux produits de nettoyage. L'analyse de la monoéthanolamine dans l'air a été habituellement difficile et les échantillons d'air ainsi que les méthodes d'analyse déjà disponibles étaient peu adaptées à l'évaluation de la concentration individuelle d'air aux postes de travail. Une nouvelle méthode plus efficace a donc été développée en captant les échantillons d'air sur des filtres de fibre de verre imprégnés, suivi par une étape de désorption, puis une Chromatographie des gaz et enfin une détection sélective des composants d'azote. Une évaluation de l'exposition des professionnels a été réalisée dans le secteur du nettoyage afin de déterminer la concentration atmosphérique en monoéthanolamine, en éthers de glycol et en alcool benzylique au cours des différentes tâches de nettoyage effectuées par les professionnels du nettoyage dans différentes entreprises, ainsi que pour déterminer les concentrations atmosphériques de fond en formaldéhyde, un polluant de l'air intérieur bien connu. L'étude de l'exposition professionnelle a été effectuée dans 12 compagnies de nettoyage et les échantillons d'air individuels ont été collectés pour l'éthanolamine (n=68), les éthers de glycol (n=79), l'alcool benzylique (n=15) et le formaldéhyde (n=45). Toutes les substances mesurées dans l'air, excepté le 2-butoxyéthanol, étaient en-dessous (<1/10) de la valeur moyenne d'exposition aux postes de travail en Suisse (8 heures), excepté pour le butoxypropanol et l'alcool benzylique, pour lesquels aucune valeur limite d'exposition n'était disponible. Bien que détecté qu'une seule fois, les concentrations d'air de 2-butoxyéthanol (n=4) étaient élevées (49,5 mg/m3 à 58,7 mg/m3), se situant au-dessus de la frontière des valeurs limites d'exposition aux postes de travail en Suisse (49 mg/m3). Les concentrations d'air de fond n'ont montré aucune présence de monoéthanolamine, alors que les éthers de glycol étaient souvent présents et les formaldéhydes quasiment toujours détectés. L'exposition des professionnels a été influencée par la quantité de monoéthanolamine présente dans les produits de nettoyage utilisés, par la ventilation extérieure et par l'emploie de sprays. Durant la dernière phase de l'étude, les informations collectées ont été utilisées pour tester un outil de modélisation de l'exposition déjà existant, l'outil de Bayesian. L'estimation de l'exposition de cet outil convergeait avec l'exposition mesurée. Cela a été le mieux décrit par une équation du second degré inversée. Les résultats suggèrent que l'outil de Bayesian n'est pas adapté pour mettre en évidence les taux d'expositions faibles. Cet outil devrait également être testé avec d'autres ensembles de données décrivant des taux d'expositions plus élevés. L'exposition répétée à des substances chimiques ayant des propriétés irritatives et sensibilisantes devrait être investiguée d'avantage, afin de mieux comprendre l'apparition de maladies respiratoires chez les professionnels du nettoyage. Des mesures de prévention devraient tout particulièrement être orientées sur l'utilisation correcte des produits de nettoyage, afin d'éviter les concentrations d'air élevées se situant à la valeur limite d'exposition acceptée.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyzed the initial adhesion and biofilm formation of Staphylococcus aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984) on various bone grafts and bone graft substitutes under standardized in vitro conditions. In parallel, microcalorimetry was evaluated as a real-time microbiological assay in the investigation of biofilm formation and material science research. The materials beta-tricalcium phosphate (beta-TCP), processed human spongiosa (Tutoplast) and poly(methyl methacrylate) (PMMA) were investigated and compared with polyethylene (PE). Bacterial counts (log(10) cfu per sample) were highest on beta-TCP (S. aureus 7.67 +/- 0.17; S. epidermidis 8.14 +/- 0.05) while bacterial density (log(10) cfu per surface) was highest on PMMA (S. aureus 6.12 +/- 0.2, S. epidermidis 7.65 +/- 0.13). Detection time for S. aureus biofilms was shorter for the porous materials (beta-TCP and processed human spongiosa, p < 0.001) compared to the smooth materials (PMMA and PE), with no differences between beta-TCP and processed human spongiosa (p > 0.05) or PMMA and PE (p > 0.05). In contrast, for S. epidermidis biofilms the detection time was different (p < 0.001) between all materials except between processed human spongiosa and PE (p > 0.05). The quantitative analysis by quantitative culture after washing and sonication of the material demonstrated the importance of monitoring factors like specific surface or porosity of the test materials. Isothermal microcalorimetry proved to be a suitable tool for an accurate, non-invasive and real-time microbiological assay, allowing the detection of bacterial biomass without removing the biofilm from the surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To control the selective adhesion of human endothelial cells and human serum proteins to bioceramics of different compositions, a multifunctional ligand containing a cyclic arginine-glycine-aspartate (RGD) peptide, a tetraethylene glycol spacer, and a gallate moiety was designed, synthesized, and characterized. The binding of this ligand to alumina-based, hydroxyapatite-based, and calcium phosphate-based bioceramics was demonstrated. The conjugation of this ligand to the bioceramics induced a decrease in the nonselective and integrin-selective binding of human serum proteins, whereas the binding and adhesion of human endothelial cells was enhanced, dependent on the particular bioceramics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The artificial dsRNA polyriboinosinic acid-polyribocytidylic acid, poly(I:C), is a potent adjuvant candidate for vaccination, as it strongly drives cell-mediated immunity. However, because of its effects on non-immune bystander cells, poly(I:C) administration may bear danger for the development of autoimmune diseases. Thus poly(I:C) should be applied in the lowest dose possible. We investigated microspheres carrying surface-assembled poly(I:C) as a two-in-one adjuvant formulation to stimulate maturation of monocyte-derived dendritic cells (MoDCs). Negatively charged polystyrene microspheres were equipped with a poly(ethylene glycol) corona through electrostatically driven surface assembly of a library of polycationic poly(l-lysine)-graft-poly(ethylene glycol) copolymers, PLL-g-PEG. Stable surface assembly of poly(I:C) was achieved by incubation of polymer-coated microspheres in an aqueous poly(I:C) solution. Surface-assembled poly(I:C) exhibited a strongly enhanced efficacy to stimulate maturation of MoDCs by up to two orders of magnitude, as compared to free poly(I:C). Multiple phagocytosis events were the key factor to enhance the efficacy. The cytokine secretion pattern of MoDCs after exposure to surface-assembled poly(I:C) differed from that of free poly(I:C), while their ability to stimulate T cell proliferation was similar. Overall, phagocytic signaling plays an important role in defining the resulting immune response to such two-in-one adjuvant formulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Photopolymerization is commonly used in a broad range of bioapplications, such as drug delivery, tissue engineering, and surgical implants, where liquid materials are injected and then hardened by means of illumination to create a solid polymer network. However, photopolymerization using a probe, e.g., needle guiding both the liquid and the curing illumination, has not been thoroughly investigated. We present a Monte Carlo model that takes into account the dynamic absorption and scattering parameters as well as solid-liquid boundaries of the photopolymer to yield the shape and volume of minimally invasively injected, photopolymerized hydrogels. In the first part of the article, our model is validated using a set of well-known poly(ethylene glycol) dimethacrylate hydrogels showing an excellent agreement between simulated and experimental volume-growth-rates. In the second part, in situ experimental results and simulations for photopolymerization in tissue cavities are presented. It was found that a cavity with a volume of 152  mm3 can be photopolymerized from the output of a 0.28-mm2 fiber by adding scattering lipid particles while only a volume of 38  mm3 (25%) was achieved without particles. The proposed model provides a simple and robust method to solve complex photopolymerization problems, where the dimension of the light source is much smaller than the volume of the photopolymerizable hydrogel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Chronic hepatitis C infection is a major cause of end-stage liver disease. Therapy outcome is influenced by 25-OH vitamin D deficiency. To further address this observation, our study investigates the impact of the vitamin D receptor (NR1I1) haplotype and combined effects of plasma vitamin D levels in a well-described cohort of hepatitis C patients. METHODS: A total of 155 chronic hepatitis C patients were recruited from the Swiss Hepatitis C Cohort Study for NR1I1 genotyping and plasma 25-OH vitamin D level measurement. NR1I1 genotype data and combined effects of plasma 25-OH vitamin D level were analysed regarding therapy response (sustained virological response). RESULTS: A strong association was observed between therapy non-response and the NR1I1 CCA (bAt) haplotype consisting of rs1544410 (BsmI) C, rs7975232 (ApaI) C and rs731236 (TaqI) A alleles. Of the HCV patients carrying the CCA haplotype, 50.3% were non-responders (odds ratio [OR] 1.69, 95% CI 1.07, 2.67; P=0.028). A similar association was observed for the combinational CCCCAA genotype (OR 2.94, 95% CI 1.36, 6.37; P=0.007). The combinational CCCCAA genotype was confirmed as an independent risk factor for non-response in multivariate analysis (OR 2.50, 95% CI 1.07, 5.87; P=0.034). Analysing combined effects, a significant impact of low 25-OH vitamin D levels on sustained virological response were only seen in patients with the unfavourable NR1I1 CCA (bAt) haplotype (OR for non-SVR 3.55; 95% CI 1.005, 12.57; P=0.049). CONCLUSIONS: NR1I1 vitamin D receptor polymorphisms influence response to pegylated-interferon/ribavirin-based therapy in chronic hepatitis C and exert an additive genetic predisposition to previously described low 25-OH vitamin D serum levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By expressing an array of pattern recognition receptors (PRRs), fibroblasts play an important role in stimulating and modulating the response of the innate immune system. The TLR3 ligand polyriboinosinic acid-polyribocytidylic acid, poly(I:C), a mimic of viral dsRNA, is a vaccine adjuvant candidate to activate professional antigen presenting cells (APCs). However, owing to its ligation with extracellular TLR3 on fibroblasts, subcutaneously administered poly(I:C) bears danger towards autoimmunity. It is thus in the interest of its clinical safety to deliver poly(I:C) in such a way that its activation of professional APCs is as efficacious as possible, whereas its interference with non-immune cells such as fibroblasts is controlled or even avoided. Complementary to our previous work with monocyte-derived dendritic cells (MoDCs), here we sought to control the delivery of poly(I:C) surface-assembled on microspheres to human foreskin fibroblasts (HFFs). Negatively charged polystyrene (PS) microspheres were equipped with a poly(ethylene glycol) (PEG) corona through electrostatically driven coatings with a series of polycationic poly(L-lysine)-graft-poly(ethylene glycol) copolymers, PLL-g-PEG, of varying grafting ratios g from 2.2 up to 22.7. Stable surface assembly of poly(I:C) was achieved by incubation of polymer-coated microspheres with aqueous poly(I:C) solutions. Notably, recognition of both surface-assembled and free poly(I:C) by extracellular TLR3 on HFFs halted their phagocytic activity. Ligation of surface-assembled poly(I:C) with extracellular TLR3 on HFFs could be controlled by tuning the grafting ratio g and thus the chain density of the PEG corona. When assembled on PLL-5.7-PEG-coated microspheres, poly(I:C) was blocked from triggering class I MHC molecule expression on HFFs. Secretion of interleukin (IL)-6 by HFFs after exposure to surface-assembled poly(I:C) was distinctly lower as compared to free poly(I:C). Overall, surface assembly of poly(I:C) may have potential to contribute to the clinical safety of this vaccine adjuvant candidate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: A new ultra congruent, postero-stabilized total knee arthroplasty (TKA) with a mobile bearing, the FIRST knee prosthesis (Free Insert in Rotation Stabilized in Translation, Symbios SA), was designed and expected to significantly reduce polyethylene wear, to improve the range of motion and the overall stability of the knee while ensuring a physiological ligament balance. Gait analysis has proven to give really objective outcome parameters after lower limb surgery. The goal of our study was to compare the subjective and really objective results of this new TKA with two other widespread models of TKA. Methods: A clinical prospective monocentric cohort study of 100 consecutive patients (47-88 yrs) undergoing a FIRST TKA for primary osteoarthritis is currently being done. Pre- and post-operative follow-ups (6 weeks, 4 months and 1 year) were done with well-recognized subjective evaluations (EQ-5D and WOMAC scores) and semi-objective questionnaires (KSS score and radiography evaluation) as well as with a really objective evaluation using gait parameters from 6 walking trials, performed at different speeds (slow, normal and fast) with an ambulatory gait analysis system (Physilog®, BioAGM CH). The outcomes of the first 32 new TKA after one year of follow-up were compared to the results after 1 year of a randomized controlled clinical trial comparing 29 NexGen® postero-stabilized TKA (Zimmer Inc) with a fixed bearing and 26 NexGen® TKA with a mobile bearing using the same methods. Results: Subjective and semi-objective results were similar for the three types of TKA. As for the really objective parameters, the gait cycle time of the FIRST TKA was statistically significantly shorter at normal speed of walk, as well as double-support periods, as compared to both standard models. The extension (in terms of range of motion when walking) of the operated knee was significantly improved for all three types of walk in favour of the FIRST TKAs compared to both NexGen TKAs. The normal walking speed was significantly higher with faster swing speed and stride lengths for the new TKA. Significantly better coordination scores were observed at normal walking speed for the FIRST TKA as compared to the fixed-bearing TKAs. Conclusion: The FIRST TKAs showed statistically significantly better objective outcomes in terms of gait after one year of follow-up with similar subjective and semi-objective results in comparison with widespread TKA designs. These encouraging short-terms results will have to be confirmed at a 5 years follow-up of the FIRST TKAs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Recent studies have described a major impact of genetic variations near the IL28B gene on the natural course and outcome of antiviral therapy in chronic hepatitis C. We therefore, aimed to explore the impact of donor and recipient genotypes of these polymorphisms on hepatitis C virus (HCV) liver graft reinfection. METHODS: Donor and recipient genotypes of IL28B rs12979860C>T single nucleotide polymorphism were determined in 91 patients with HCV liver graft reinfection, 47 of whom were treated with pegylated interferon-α (PEG-IFN-α) and ribavirin. IL28B genetic polymorphisms were correlated with the natural course and treatment outcome of recurrent hepatitis C. RESULTS: Patients requiring liver transplantation due to end-stage chronic hepatitis C appeared to be selected toward the adverse genotypes rs12979860 CT/TT compared to non-transplanted HCV-infected patients (p=0.046). Patients with the donor genotype rs12979860 CC had higher peak ALT and HCV RNA serum concentrations than those with CT/TT (p=0.04 and 0.06, respectively). No association was observed between ALT/HCV RNA serum concentrations and recipient genotypes (p>0.3). More important, donor IL28B rs12979860 CC vs. CT/TT genotypes were associated with rapid, complete early, and sustained virologic response (RVR, cEVR, SVR) to treatment with PEG-IFN-α and ribavirin (p=0.003, 0.0012, 0.008, respectively), but weaker associations of recipient genotypes with RVR, cEVR, and SVR were observed as well (p=0.0046, 0.115, 0.118, respectively). CONCLUSIONS: We provide evidence for a dominant, but not exclusive impact of the donor rather than the recipient IL28B genetic background on the natural course and treatment outcome of HCV liver graft reinfection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The chemical functionalization of cell-surface proteins of human primary fetal bone cells with hydrophilic bioorthogonal intermediates was investigated. Toward this goal, chemical pathways were developed for click reaction-mediated coupling of alkyne derivatives with cellular azido-expressing proteins. The incorporation via a tetraethylene glycol linker of a dipeptide and a reporter biotin allowed the proof of concept for the introduction of cell-specific peptide ligands and to follow the reaction in living cells. Tuning the conditions of the click reaction resulted in chemical functionalization of living human fetal osteoblasts with excellent cell survival.