71 resultados para P values


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increased renal resistive index (RRI) has been recently associated with target organ damage and cardiovascular or renal outcomes in patients with hypertension and diabetes mellitus. However, reference values in the general population and information on familial aggregation are largely lacking. We determined the distribution of RRI, associated factors, and heritability in a population-based study. Families of European ancestry were randomly selected in 3 Swiss cities. Anthropometric parameters and cardiovascular risk factors were assessed. A renal Doppler ultrasound was performed, and RRI was measured in 3 segmental arteries of both kidneys. We used multilevel linear regression analysis to explore the factors associated with RRI, adjusting for center and family relationships. Sex-specific reference values for RRI were generated according to age. Heritability was estimated by variance components using the ASSOC program (SAGE software). Four hundred women (mean age±SD, 44.9±16.7 years) and 326 men (42.1±16.8 years) with normal renal ultrasound had mean RRI of 0.64±0.05 and 0.62±0.05, respectively (P<0.001). In multivariable analyses, RRI was positively associated with female sex, age, systolic blood pressure, and body mass index. We observed an inverse correlation with diastolic blood pressure and heart rate. Age had a nonlinear association with RRI. We found no independent association of RRI with diabetes mellitus, hypertension treatment, smoking, cholesterol levels, or estimated glomerular filtration rate. The adjusted heritability estimate was 42±8% (P<0.001). In a population-based sample with normal renal ultrasound, RRI normal values depend on sex, age, blood pressure, heart rate, and body mass index. The significant heritability of RRI suggests that genes influence this phenotype.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: Increased altruism, self-transcendence, and quests for meaning in life (MiL) have been found in palliative care (PC) patients and their families who experience the finiteness of life. Similar changes were observed in healthy subjects who were experimentally confronted with their mortality. OBJECTIVES: The study investigated how daily experiences of the transitoriness of life influence PC health care professionals' (HCPs) values, MiL, and religiousness. METHODS: In a cross-sectional study, the Schwartz Value Survey, the Schedule for Meaning in Life Evaluation, and the Idler Index of Religiosity were used to investigate personal values, MiL, and private religiousness. HCPs working in PC (confronted with death) were compared with a control group of HCPs working at maternity wards (MWs) using multivariate models. Differences were considered to be statistically significant at P < 0.05. RESULTS: Seventy PC- and 70 MW-HCPs took part in the study (response rate 74.0%). No differences between the groups were found in overall MiL satisfaction scores. PC-HCPs were significantly more religious than MW-HCPs; they listed spirituality and nature experience more often as areas in which they experience MiL. Furthermore, hedonism was more important for PC-HCPs, and they had higher scores in openness-to-change values (stimulation and self-direction). MW-HCPs were more likely to list family as a MiL area. They assigned more importance to health and scored higher in conservation values (conformity and security). Duration of professional experience did not influence these results. CONCLUSION: Basic differences in values, MiL, and religiousness between PC-HCPs and MW-HCPs might have influenced the choice of working environment because no effect of job duration was observed. Longitudinal research is needed to confirm this hypothesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73+/-0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87+/-0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laboratory values of the most commonly assayed clinical chemistry variables were determined in selected elderly and healthy ambulatory populations. The upper and lower limits (2.5 and 97.5 fractiles) were compared with the adult reference values in use in university hospitals of Switzerland. The results suggest that conventional adult reference values can be used for most variables in the elderly and that these values are also useful in an ambulatory population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To identify risk factors associated with mortality in patients with severe community-acquired pneumonia (CAP) caused by S. pneumoniae who require intensive care unit (ICU) management, and to assess the prognostic values of these risk factors at the time of admission. METHODS: Retrospective analysis of all consecutive patients with CAP caused by S. pneumoniae who were admitted to the 32-bed medico-surgical ICU of a community and referral university hospital between 2002 and 2011. Univariate and multivariate analyses were performed on variables available at admission. RESULTS: Among the 77 adult patients with severe CAP caused by S. pneumoniae who required ICU management, 12 patients died (observed mortality rate 15.6 %). Univariate analysis indicated that septic shock and low C-reactive protein (CRP) values at admission were associated with an increased risk of death. In a multivariate model, after adjustment for age and gender, septic shock [odds ratio (OR), confidence interval 95 %; 4.96, 1.11-22.25; p = 0.036], and CRP (OR 0.99, 0.98-0.99 p = 0.034) remained significantly associated with death. Finally, we assessed the discriminative ability of CRP to predict mortality by computing its receiver operating characteristic curve. The CRP value cut-off for the best sensitivity and specificity was 169.5 mg/L to predict hospital mortality with an area under the curve of 0.72 (0.55-0.89). CONCLUSIONS: The mortality of patients with S. pneumoniae CAP requiring ICU management was much lower than predicted by severity scores. The presence of septic shock and a CRP value at admission <169.5 mg/L predicted a fatal outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract: This study aims at identifying the organisational antecedents of public service motivation (PSM). It focuses on human resources management (HRM) practices as one category of organisational factors that impact on PSM. Concretely, this research questions how intrinsic and extrinsic HRM practices are related to PSM and whether these relationships are direct or mediated by person-organisation (P-O) fit. The empirical findings are based on a survey of 6,885 civil servants working in Switzerland. Regression analyses highlight that intrinsic HRM practices are positively related to PSM, whereas extrinsic ones are negatively related to PSM. Furthermore, mediation tests shows that only the intrinsic HRM practices are mediated by PO fit. Thus, civil servants who value intrinsic work incentives maintain a high PSM level when they perceive congruence between their individual expectations and the values of their organisation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To determine inter-session and intra/inter-individual variations of the attenuations of aortic blood/myocardium with MDCT in the context of calcium scoring. To evaluate whether these variations are dependent on patients' characteristics. METHODS: Fifty-four volunteers were evaluated with calcium scoring non-enhanced CT. We measured attenuations (inter-individual variation) and standard deviations (SD, intra-individual variation) of the blood in the ascending aorta and of the myocardium of left ventricle. Every volunteer was examined twice to study the inter-session variation. The fat pad thickness at the sternum and noise (SD of air) were measured too. These values were correlated with the measured aortic/ventricular attenuations and their SDs (Pearson). Historically fixed thresholds (90 and 130 HU) were tested against different models based on attenuations of blood/ventricle. RESULTS: The mean attenuation was 46 HU (range, 17-84 HU) with mean SD 23 HU for the blood, and 39 HU (10-82 HU) with mean SD 18 HU for the myocardium. The attenuation/SD of the blood were significantly higher than those of the myocardium (p < 0.01). The inter-session variation was not significant. There was a poor correlation between SD of aortic blood/ventricle with fat thickness/noise. Based on existing models, 90 HU threshold offers a confidence interval of approximately 95% and 130 HU more than 99%. CONCLUSIONS: Historical thresholds offer high confidence intervals for exclusion of aortic blood/myocardium and by the way for detecting calcifications. Nevertheless, considering the large variations of blood/myocardium CT values and the influence of patient's characteristics, a better approach might be an adaptive threshold.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Pancreatic stone protein (PSP) has been identified as a promising sepsis marker in adults, children and neonates. However, data on population-based reference values are lacking. This study aimed to establish age-specific reference values for PSP. METHODS: PSP was determined using a specific ELISA. PSP serum concentrations were determined in 372 healthy subjects including 217 neonates, 94 infants and children up to 16 years, and 61 adults. The adjacent categories method was used to determine which age categories had significantly different PSP concentrations. RESULTS: PSP circulating levels were not gender-dependent and ranged from 1.0 to 99.4 ng/ml with a median of 9.2 ng/ml. PSP increased significantly between the age categories, from a median of 2.6 ng/ml in very preterm newborns, to 6.3 ng/ml in term newborns, to 16.1 ng/ml in older children (p < 0.001). PSP levels were higher on postnatal day three compared to levels measured immediately post delivery (p < 0.001). Paired umbilical artery and umbilical vein samples were strongly correlated (p < 0.001). Simultaneously obtained capillary heel-prick versus venous samples showed a good level of agreement for PSP (Rho 0.89, bias 19 %). CONCLUSIONS: This study provides age-specific normal values that may be used to define cut-offs for future trials on PSP. We demonstrate an age-dependent increase of PSP from birth to childhood.