414 resultados para Outcome measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: Therapeutic Drug Monitoring (TDM) has been introduced early 1970 in our hospital (CHUV). It represents nowadays an important routine activity of the Division of Clinical Pharmacology and Toxicology (PCL), and its impact and utility for clinicians required assessment. This study thus evaluated the impact of TDM recommendations in terms of dosage regimen adaptation. Design: A prospective observational study was conducted over 5 weeks. The primary objective was to evaluate the application of our TDM recommendations and to identify potential factors associated to variations in their implementation. The secondary objective was to identify pre-analytical problems linked to the collection and processing of blood samples. Setting: Four representative clinical units at CHUV. Main outcome measure: Clinical data, drug related data (intake, collection and processing) and all information regarding the implementation of clinical recommendations were collected and analyzed by descriptive statistics. Results: A total of 241 blood measurement requests were collected, among which 105 triggered a recommendation. 37% of the recommendations delivered were applied, 25 % partially applied and 34% not applied. In 4% it was not applicable. The factors determinant for implementation were the clinical unit and the mode of transmission of the recommendation (written vs oral). No clear difference between types of drugs could be detected. Pre-analytical problems were not uncommon, mostly related to completion of request forms and delays in blood sampling (equilibration or steady-state not reached). We have identified 6% of inappropriate and unusable drug level measurements that could cause a substantial cost for the hospital. Conclusion: This survey highlighted a better implementation of TDM recommendations in clinical units where this routine is well integrated and understood by the medical staff. Our results emphasize the importance of communication with the nurse or the physician in charge, either to transmit clinical recommendations or to establish consensual therapeutic targets in specific conditions. Development of strong partnerships between clinical pharmacists or pharmacologists and clinical units would be beneficial to improve the impact of this clinical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We examined the correlation between the quantitative margin analysis of two laboratory test methods (Berlin, Zurich) and the clinical outcome in Class V restorations. METHODS: Prospective clinical studies with an observation period of at least 18 months were searched in the literature, for which laboratory data were also available. The clinical outcome variables were retention loss, marginal discoloration, detectable margins and secondary caries. Forty-four clinical studies matched the inclusion criteria, including 34 adhesive systems for which laboratory data were also present. For both laboratory test methods and the clinical studies, an index was formulated to better compare the in vitro and in vivo results. Linear mixed models which included a random study effect were calculated. As most clinical data were available for 12 and 24 months, the main analysis was restricted to these recall intervals. RESULTS: The comparative analysis revealed a weak correlation between the clinical index and both in vitro indices. The correlation was statistically significant for the Berlin method but not for the Zurich method and only present if studies were compared which used the same composite in the in vitro and in vivo study. When defining specific cut-off values, the prognosis for the good clinical performance of an adhesive system based on in vitro results was 78% (Berlin) or 100% (Zurich). For poor performance it was 67% and 60%, respectively. No correlation was found between both in vitro methods. SIGNIFICANCE: The surrogate parameter "marginal adaptation" of restorations placed in extracted teeth has a mediocre value to predict the clinical performance of an adhesive system in cervical cavities. The composite is an important factor for a successful prediction. The comparison between in vitro/in vivo is sometimes hampered by the great variability of clinical results on the same adhesive system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the prognostic accuracy of perfusion computed tomography (CT), performed at the time of emergency room admission, in acute stroke patients. Accuracy was determined by comparison of perfusion CT with delayed magnetic resonance (MR) and by monitoring the evolution of each patient's clinical condition. Twenty-two acute stroke patients underwent perfusion CT covering four contiguous 10mm slices on admission, as well as delayed MR, performed after a median interval of 3 days after emergency room admission. Eight were treated with thrombolytic agents. Infarct size on the admission perfusion CT was compared with that on the delayed diffusion-weighted (DWI)-MR, chosen as the gold standard. Delayed magnetic resonance angiography and perfusion-weighted MR were used to detect recanalization. A potential recuperation ratio, defined as PRR = penumbra size/(penumbra size + infarct size) on the admission perfusion CT, was compared with the evolution in each patient's clinical condition, defined by the National Institutes of Health Stroke Scale (NIHSS). In the 8 cases with arterial recanalization, the size of the cerebral infarct on the delayed DWI-MR was larger than or equal to that of the infarct on the admission perfusion CT, but smaller than or equal to that of the ischemic lesion on the admission perfusion CT; and the observed improvement in the NIHSS correlated with the PRR (correlation coefficient = 0.833). In the 14 cases with persistent arterial occlusion, infarct size on the delayed DWI-MR correlated with ischemic lesion size on the admission perfusion CT (r = 0.958). In all 22 patients, the admission NIHSS correlated with the size of the ischemic area on the admission perfusion CT (r = 0.627). Based on these findings, we conclude that perfusion CT allows the accurate prediction of the final infarct size and the evaluation of clinical prognosis for acute stroke patients at the time of emergency evaluation. It may also provide information about the extent of the penumbra. Perfusion CT could therefore be a valuable tool in the early management of acute stroke patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Reported survival after cardiopulmonary resuscitation (CPR) in children varies considerably. We aimed to identify predictors of 1-year survival and to assess long-term neurological status after in- or outpatient CPR. DESIGN: Retrospective review of the medical records and prospective follow-up of CPR survivors. SETTING: Tertiary care pediatric university hospital. PATIENTS AND METHODS: During a 30-month period, 89 in- and outpatients received advanced CPR. Survivors of CPR were prospectively followed-up for 1 year. Neurological outcome was assessed by the Pediatric Cerebral Performance Category scale (PCPC). Variables predicting 1-year survival were identified by multivariable logistic regression analysis. INTERVENTIONS: None. RESULTS: Seventy-one of the 89 patients were successfully resuscitated. During subsequent hospitalization do-not-resuscitate orders were issued in 25 patients. At 1 year, 48 (54%) were alive, including two of the 25 patients with out-of-hospital CPR. All patients died, who required CPR after trauma or near drowning, when CPR began >10 min after arrest or with CPR duration >60 min. Prolonged CPR (21-60 min) was compatible with survival (five of 19). At 1 year, 77% of the survivors had the same PCPC score as prior to CPR. Predictors of survival were location of resuscitation, CPR during peri- or postoperative care, and duration of resuscitation. A clinical score (0-15 points) based on these three items yielded an area under the ROC of 0.93. CONCLUSIONS: Independent determinants of long-term survival of pediatric resuscitation are location of arrest, underlying cause, and duration of CPR. Long-term survivors have little or no change in neurological status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the sensitivity of the perfusion parameters derived from Intravoxel Incoherent Motion (IVIM) MR imaging to hypercapnia-induced vasodilatation and hyperoxygenation-induced vasoconstriction in the human brain. Materials and Methods: This study was approved by the local ethics committee and informed consent was obtained from all participants. Images were acquired with a standard pulsed-gradient spin-echo sequence (Stejskal-Tanner) in a clinical 3-T system by using 16 b values ranging from 0 to 900 sec/mm(2). Seven healthy volunteers were examined while they inhaled four different gas mixtures known to modify brain perfusion (pure oxygen, ambient air, 5% CO(2) in ambient air, and 8% CO(2) in ambient air). Diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), and blood flow-related parameter (fD*) maps were calculated on the basis of the IVIM biexponential model, and the parametric maps were compared among the four different gas mixtures. Paired, one-tailed Student t tests were performed to assess for statistically significant differences. Results: Signal decay curves were biexponential in the brain parenchyma of all volunteers. When compared with inhaled ambient air, the IVIM perfusion parameters D*, f, and fD* increased as the concentration of inhaled CO(2) was increased (for the entire brain, P = .01 for f, D*, and fD* for CO(2) 5%; P = .02 for f, and P = .01 for D* and fD* for CO(2) 8%), and a trend toward a reduction was observed when participants inhaled pure oxygen (although P > .05). D remained globally stable. Conclusion: The IVIM perfusion parameters were reactive to hyperoxygenation-induced vasoconstriction and hypercapnia-induced vasodilatation. Accordingly, IVIM imaging was found to be a valid and promising method to quantify brain perfusion in humans. © RSNA, 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the past twenty years, various instruments have been developed for the assessment of substance use in adolescents, mainly in the United States. However, few of them have been adapted to, and validated in, French-speaking populations. Consequently, although increasing alcohol and drug use among teenagers has become a major concern, the various health and social programs developed in response to this specific problem have received little attention with regard to follow-up and outcome assessment. A standardized multidimensional assessment instrument adapted for adolescents is needed to assess the individual needs of adolescents and assign them to the most appropriate treatment setting, to provide a single measurement within and across health and social systems, and to conduct treatment outcome evaluations. Moreover, having an available instrument makes it possible to develop longitudinal and transcultural research studies. For this reason, a French version of the Adolescent Drug Abuse Diagnosis (ADAD) was developed and validated at the University Child and Adolescent Psychiatric Clinic in Lausanne, Switzerland. This article aims to discuss the methodological issues that we faced when using the ADAD instrument in a 4-year longitudinal study including adolescent substance users. Methodological aspects relating to the content and format of the instrument, the assessment administration and the statistical analyses are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Introduction : Les naissances prématurées compliquent 6-10 % des grossesses dans les pays industrialisés et contribuent de façon notable aux taux de mortalité périnatale et de morbidité néonatale. Il a été démontré que la colonisation bactérienne du liquide amniotique joue un rôle dans l'étiologie des accouchements prématurés spontanés et des ruptures prématurées des membranes. Le but de ce travail était d'évaluer la présence de Mycoplasma hominis dans le liquide amniotique prélevé au 2eme trimestre de grossesse chez des patientes asymptomatiques et de déterminer son association avec une issue défavorable de la grossesse. Matériels et méthodes : Les échantillons de liquide amniotique de 456 patientes ayant subi une amniocentèse trans-abdominale entre les 15eme et I7eme semaines de grossesse pour diverses indications ont été testés par PCR (Polymerase Chain Reaction) afin d'identifier Mycoplasma hominis. Les produits ainsi amplifiés étaient ensuite détectés par ELISA (Enzyme-Linked Immunosorbent Assay). Les données cliniques étaient obtenues après l'accouchement. Résultats : Mycoplasma hominis a été identifié dans 29 (6,4%) des échantillons de liquide amniotique. Le taux de menace d'accouchement prématuré chez les patientes positives pour Mycoplasma hominis (14,3%) était plus élevé que chez les patientes négatives (3,3 %) (p=0,01). De même, les naissances prématurées spontanées avec membranes intactes étaient plus fréquentes chez les patientes positives (10,7%) que chez les patientes négatives (1,9 %) (p=0,02). Le taux de menace d'accouchement prématuré lors d'une grossesse antérieure était plus de trois fois plus élevé chez les patientes positives, cependant ce résultat n'était pas statistiquement significatif. Finalement, la présence du mycoplasme n'était pas corrélée à la gestose, au retard de croissance intra-utérin ou aux anomalies chromosomiques foetales. Conclusions : Les résultats montrent que la présence de Mycoplasma hominis dans le liquide amniotique prélevé entre les 15eme et I7eme semaines d' aménorrhée chez des patientes asymptomatiques est associée à un taux plus élevé de menace d'accouchement prématuré et de naissances prématurées spontanées. La détection de ce microorganisme au 2eme trimestre de la grossesse peut donc identifier les patientes à risque de menace d'accouchement et de naissance prématurées. Abstract Objective: The relationship between detection of Mycoplasma hominis in mid-trimester amniotic fluid and subsequent pregnancy outcome was investigated. Study design: Amniotic fluids from 456 women of European background who underwent a transabdominal amniocentesis at weeks 15-17 of pregnancy were tested for M. hominis by polymerase chain reaction (PCR). The amplicons were hybridized to an internal probe and detected by ELISA. Pregnancy outcomes and clinical data were subsequently obtained. Results: M. hominis were identified in 29 (6.4%) of the amniotic fluids. The rate of preterm labor in women positive for M. hominis (14.3%) was higher than in the negative women (3.3%) (p = 0.01). Similarly, a spontaneous preterm birth with intact membranes occurred in 10.7% of the M. hominis-posltive women as opposed to only 1.9% of the negative women (p = 0.02). The presence of this mycoplasma was not correlated with fetal chromosomal aberrations, intrauterine growth restriction or preeclampsia. Conclusions: Detection of M. hominis in second-trimester amniotic fluids can identify women at increased risk for subsequent preterm labor and delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To study the clinical outcome in hippocampal deep brain stimulation (DBS) for the treatment of patients with refractory mesial temporal lobe epilepsy (MTLE) according to the electrode location. METHODS: Eight MTLE patients implanted in the hippocampus and stimulated with high-frequency DBS were included in this study. Five underwent invasive recordings with depth electrodes to localize ictal onset zone prior to chronic DBS. Position of the active contacts of the electrode was calculated on postoperative imaging. The distances to the ictal onset zone were measured as well as atlas-based hippocampus structures impacted by stimulation were identified. Both were correlated with seizure frequency reduction. RESULTS: The distances between active electrode location and estimated ictal onset zone were 11±4.3 or 9.1±2.3mm for patients with a >50% or <50% reduction in seizure frequency. In patients (N=6) showing a >50% seizure frequency reduction, 100% had the active contacts located <3mm from the subiculum (p<0.05). The 2 non-responders patients were stimulated on contacts located >3mm to the subiculum. CONCLUSION: Decrease of epileptogenic activity induced by hippocampal DBS in refractory MTLE: (1) seems not directly associated with the vicinity of active electrode to the ictal focus determined by invasive recordings; (2) might be obtained through the neuromodulation of the subiculum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To establish if hyperglycaemia and cardiac Troponin I (cTnI) after congenital heart surgery on cardiopulmonary bypass in children could predict outcome in intensive care unit. Methods: retrospective cohort study including 274 children (mean age 4.6 years; range 0 - 17 years-old). CTnI and glucose values were retrieved from our database. Integrated values (area under the curve (AUC)) were calculated for evaluation of sustained hyperglycaemia and then normalised per hour (48h-Gluc/h). Maximal cTnI, fi rst glucose value (Gluc1) and 48h-Gluc/h were then correlated with duration of mechanical ventilation, ICU stay and mortality using cut-off values. Results: The mean duration of mechanical ventilation was 5.1 ± 7.2 days and ICU stay was 11.0 ± 13.3 days, 11 patients (3.9%) died. Hyperglycaemia (>6.1 mmol/l) was present in 68% of children at admission and was sustained in 85% for 48 hours. The mean value of Gluc1 (7.3 ± 2.7 vs. 11.8 ± 6.4 mmol/l, p < 0.0001), 48h-Gluc/h (7.4 ± 1.4 vs. 9.9 ± 4.6 mmol/l/h, p < 0.0001) and cTnI max (16.7 ± 21.8 vs. 59.2 ± 41.4 mcg/l, p < 0.0001) were signifi cantly lower in survivors vs. non survivors. Cut-off values and odds ratio are summarised in Table 1. Analyses for duration of mechanical ventilation and for length of stay in ICU are depicted in Table 2. Conclusions: Hyperglycaemia is frequent after cardiopulmonary bypass and sustained in the fi rst 48 hours. Admission glycaemia and cTnI max are associated with a high risk of mortality, prolonged duration of mechanical ventilation and prolonged length of stay in ICU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the clinical outcome of patients who were subjected to long-axis sacroplasty as first line treatment for sacral insufficiency fractures. Methods and materials: Nineteen patients with unilateral (n = 3) or bilateral (n = 16) sacral fractures were involved. Under local anaesthesia, each patient was subjected to CT guided sacroplasty using the long-axis approach through a single entry point. An average of 6 ml of PMMA was delivered along the path of each sacral fracture. For each individual patient, the VAS pain score before sacroplasty and at 1, 4, 24, and 48 weeks after the procedure was obtained. Furthermore, the use of analgesics (narcotic/non-narcotic) along with the evolution of post interventional patient mobility before and after sacroplasty was also recorded. Results: The mean pre-procedure VAS score was 8 ± 1.9. This has rapidly declined in the first week after the procedure (mean 4 ± 1.5) followed by gradual decrease along the rest of follow-up period at 4 weeks (mean 3 ± 1.2), 24 weeks (mean 2 ± 1.3), and 48 weeks (mean 1.3 ± 1.4), respectively. Eleven (58%) patients were under narcotic analgesia before sacroplasty, whereas, 8 (42%) patients were using non-narcotics. Corresponding values after the procedure were 2/19 (10%) (narcotic) and 10/19 53% (non-narcotic). Seven (37%) patients did not address post-procedure analgesic use. The evolution of post interventional mobility was favourable in the study group since they revealed a significant improvement in their mobility point scale. Conclusion: Long-axis percutaneous sacroplasty is a suitable minimally invasive treatment option for patients who present with sacral insufficiency fractures. Future studies with larger patient number are warranted to grasp any potential limitations of this therapeutic approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.