336 resultados para Optimal monitoring
Resumo:
This paper presents a review of different methods enabling the monitoring of cerebral function in neonatal and paediatric intensive care. EEG, evoked potentials, conventional radiological studies, computerized tomography, ultrasound, intracranial pressure measurements, nuclear magnetic resonance, Doppler ultrasound, radioisotope studies, angiography, infra-red spectral analysis and last, but not least, clinical examination produce information regarding the neurological state of the patient which must be critically analysed in order to ensure optimal management of the case. Unfortunately, and in spite of impressive progress in non-invasive monitoring of the cerebral function, we are still forced to make important medical and ethical decisions without precise information about the neurological state of our patients.
Resumo:
Imaging mass spectrometry (IMS) is useful for visualizing the localization of phospholipids on biological tissue surfaces creating great opportunities for IMS in lipidomic investigations. With advancements in IMS of lipids, there is a demand for large-scale tissue studies necessitating stable, efficient and well-defined sample handling procedures. Our work within this article shows the effects of different storage conditions on the phospholipid composition of sectioned tissues from mouse organs. We have taken serial sections from mouse brain, kidney and liver thaw mounted unto ITO-coated glass slides and stored them under various conditions later analyzing them at fixed time points. A global decrease in phospholipid signal intensity is shown to occur and to be a function of time and temperature. Contrary to the global decrease, oxidized phospholipid and lysophospholipid species are found to increase within 2 h and 24 h, respectively, when mounted sections are kept at ambient room conditions. Imaging experiments reveal that degradation products increase globally across the tissue. Degradation is shown to be inhibited by cold temperatures, with sample integrity maintained up to a week after storage in −80 °C freezer under N2 atmosphere. Overall, the results demonstrate a timeline of the effects of lipid degradation specific to sectioned tissues and provide several lipid species which can serve as markers of degradation. Importantly, the timeline demonstrates oxidative sample degradation begins appearing within the normal timescale of IMS sample preparation of lipids (i.e. 1-2 h) and that long-term degradation is global. Taken together, these results strengthen the notion that standardized procedures are required for phospholipid IMS of large sample sets, or in studies where many serial sections are prepared together but analyzed over time such as in 3-D IMS reconstruction experiments.
Resumo:
Objective Biomonitoring of solvents using the unchanged substance in urine as exposure indicator is still relatively scarce due to some discrepancies between the results reported in the literature. Based on the assessment of toluene exposure, the aim of this work was to evaluate the effects of some steps likely to bias the results and to measure urinary toluene both in volunteers experimentally exposed and in workers of rotogravure factories. Methods Static headspace was used for toluene analysis. o-Cresol was also measured for comparison. Urine collection, storage and conservation conditions were studied to evaluate possible loss or contamination of toluene in controlled situations applied to six volunteers in an exposure chamber according to four scenarios with exposure at stable levels from 10 to 50 ppm. Kinetics of elimination of toluene were determined over 24 h. A field study was then carried out in a total of 29 workers from two rotogravure printing facilities. Results Potential contamination during urine collection in the field is confirmed to be a real problem but technical precautions for sampling, storage and analysis can be easily followed to control the situation. In the volunteers at rest, urinary toluene showed a rapid increase after 2 h with a steady level after about 3 h. At 47.1 ppm the mean cumulated excretion was about 0.005% of the amount of the toluene ventilated. Correlation between the toluene levels in air and in end of exposure urinary sample was excellent (r = 0.965). In the field study, the median personal exposure to toluene was 32 ppm (range 3.6-148). According to the correlations between environmental and biological monitoring data, the post-shift urinary toluene (r = 0.921) and o-cresol (r = 0.873) concentrations were, respectively, 75.6 mu g/l and 0.76 mg/g creatinine for 50 ppm toluene personal exposure. The corresponding urinary toluene concentration before the next shift was 11 mu g/l (r = 0.883). Conclusion Urinary toluene was shown once more time a very interesting surrogate to o-cresol and could be recommended as a biomarker of choice for solvent exposure. [Authors]
Resumo:
Near infrared spectroscopy (NIRS) is a non-invasive method of estimating the haemoglobin concentration changes in certain tissues. It is frequently used to monitor oxygenation of the brain in neonates. At present it is not clear whether near infrared spectroscopy of other organs (e.g. the liver as a corresponding site in the splanchnic region, which reacts very sensitively to haemodynamic instability) provides reliable values on their tissue oxygenation. The aim of the study was to test near infrared spectroscopy by measuring known physiologic changes in tissue oxygenation of the liver in newborn infants during and after feeding via a naso-gastric tube. The test-retest variability of such measurements was also determined. On 28 occasions in 25 infants we measured the tissue oxygenation index (TOI) of the liver and the brain continuously before, during and 30 minutes after feeding via a gastric tube. Simultaneously we measured arterial oxygen saturation (SaO2), heart rate (HR) and mean arterial blood pressure (MAP). In 10 other newborn infants we performed a test-retest analysis of the liver tissue oxygenation index to estimate the variability in repeated intra-individual measurements. The tissue oxygenation index of the liver increased significantly from 56.7 +/- 7.5% before to 60.3 +/- 5.6% after feeding (p < 0.005), and remained unchanged for the next 30 minutes. The tissue oxygenation index of the brain (62.1 +/- 9.7%), SaO2 (94.4 +/- 7.1%), heart rate (145 +/- 17.3 min-1) and mean arterial blood pressure (52.8 +/- 10.2 mm Hg) did not change significantly. The test-retest variability for intra-individual measurements was 2.7 +/- 2.1%. After bolus feeding the tissue oxygenation index of the liver increased as expected. This indicates that near infrared spectroscopy is suitable for monitoring changes in tissue oxygenation of the liver in newborn infants.
Resumo:
IMPORTANCE: New data and antiretroviral regimens expand treatment choices in resource-rich settings and warrant an update of recommendations to treat adults infected with human immunodeficiency virus (HIV). OBJECTIVE: To provide updated treatment recommendations for adults with HIV, emphasizing when to start treatment; what treatment to start; the use of laboratory monitoring tools; and managing treatment failure, switches, and simplification. DATA SOURCES, STUDY SELECTION, AND DATA SYNTHESIS: An International Antiviral Society-USA panel of experts in HIV research and patient care considered previous data and reviewed new data since the 2012 update with literature searches in PubMed and EMBASE through June 2014. Recommendations and ratings were based on the quality of evidence and consensus. RESULTS: Antiretroviral therapy is recommended for all adults with HIV infection. Evidence for benefits of treatment and quality of available data increase at lower CD4 cell counts. Recommended initial regimens include 2 nucleoside reverse transcriptase inhibitors (NRTIs; abacavir/lamivudine or tenofovir disoproxil fumarate/emtricitabine) and a third single or boosted drug, which should be an integrase strand transfer inhibitor (dolutegravir, elvitegravir, or raltegravir), a nonnucleoside reverse transcriptase inhibitor (efavirenz or rilpivirine) or a boosted protease inhibitor (darunavir or atazanavir). Alternative regimens are available. Boosted protease inhibitor monotherapy is generally not recommended, but NRTI-sparing approaches may be considered. New guidance for optimal timing of monitoring of laboratory parameters is provided. Suspected treatment failure warrants rapid confirmation, performance of resistance testing while the patient is receiving the failing regimen, and evaluation of reasons for failure before consideration of switching therapy. Regimen switches for adverse effects, convenience, or to reduce costs should not jeopardize antiretroviral potency. CONCLUSIONS AND RELEVANCE: After confirmed diagnosis of HIV infection, antiretroviral therapy should be initiated in all individuals who are willing and ready to start treatment. Regimens should be selected or changed based on resistance test results with consideration of dosing frequency, pill burden, adverse toxic effect profiles, comorbidities, and drug interactions.
Resumo:
Le monitoring de la problématique du cannabis en Suisse constitue un ensemble de travaux qui permet un suivi de la situation au niveau national et dont la mise en oeuvre est le fait d'un consortium d'instituts. Ce monitoring comprend l'étude présentée dans ce rapport, l'étude sentinelle. Elle s'intéresse à l'évolution de la situation en matière de cannabis ainsi qu'à la gestion de cette situation au niveau local. Ainsi, les observations relevées par des professionnels de terrain dans différents domaines (santé/social, école/formation professionnelle, police/justice) et dans quatre cantons suisses (St Gall, Tessin, Vaud, Zurich), dits "sentinelles", sont récoltées et analysées annuellement.
Resumo:
The study of natural T cell responses against pathogens or tumors, as well as the assessment of new immunotherapy strategies aimed at boosting these responses, requires increasingly precise ex vivo analysis of blood samples. For practical reasons, studies are often performed using purified PBMC samples, usually cryopreserved. Here, we report on FACS analyses of peripheral blood T cells, performed by direct antibody staining of non-purified total blood. For comparison, fresh PBMC, purified by Ficoll, were analysed. Our results show that the latter method can induce a bias in subpopulation distribution, in particular of CD8+ T cells, and sometimes lead to inaccurate measurement of antigen specific CD8+ T cell responses. Direct analysis of total blood can be applied to longitudinal immuno-monitoring of T cell-based therapy. While the need to purify and cryopreserve PBMC for subsequent studies is obvious, the use of whole blood has the advantage of providing unbiased results and only small amounts of blood are used.
Resumo:
The root-colonizing bacterium Pseudomonas fluorescens CHA0 was used to construct an oxygen-responsive biosensor. An anaerobically inducible promoter of Pseudomonas aeruginosa, which depends on the FNR (fumarate and nitrate reductase regulation)-like transcriptional regulator ANR (anaerobic regulation of arginine deiminase and nitrate reductase pathways), was fused to the structural lacZ gene of Escherichia coli. By inserting the reporter fusion into the chromosomal attTn7 site of P. fluorescens CHA0 by using a mini-Tn7 transposon, the reporter strain, CHA900, was obtained. Grown in glutamate-yeast extract medium in an oxystat at defined oxygen levels, the biosensor CHA900 responded to a decrease in oxygen concentration from 210 x 10(2) Pa to 2 x 10(2) Pa of O(2) by a nearly 100-fold increase in beta-galactosidase activity. Half-maximal induction of the reporter occurred at about 5 x 10(2) Pa. This dose response closely resembles that found for E. coli promoters which are activated by the FNR protein. In a carbon-free buffer or in bulk soil, the biosensor CHA900 still responded to a decrease in oxygen concentration, although here induction was about 10 times lower and the low oxygen response was gradually lost within 3 days. Introduced into a barley-soil microcosm, the biosensor could report decreasing oxygen concentrations in the rhizosphere for a 6-day period. When the water content in the microcosm was raised from 60% to 85% of field capacity, expression of the reporter gene was elevated about twofold above a basal level after 2 days of incubation, suggesting that a water content of 85% caused mild anoxia. Increased compaction of the soil was shown to have a faster and more dramatic effect on the expression of the oxygen reporter than soil water content alone, indicating that factors other than the water-filled pore space influenced the oxygen status of the soil. These experiments illustrate the utility of the biosensor for detecting low oxygen concentrations in the rhizosphere and other soil habitats.
Resumo:
The purpose of this study was to test melanoma vaccines consisting of peptides and immunological adjuvants for optimal immunogenicity and to evaluate laboratory immune monitoring for in vivo relevance. Forty-nine HLA-A2 positive patients with Melan-A positive melanoma were repeatedly vaccinated with Melan-A peptide, with or without immune adjuvant AS02B (QS21 and MPL) or IFA. Peptide-specific CD8 T cells in PBLs were analyzed ex vivo using fluorescent HLA-A2/Melan-A multimers and IFN-gamma ELISPOT assays. The vaccines were well tolerated. In vivo expansion of Melan-A-specific CD8 T cells was observed in 13 patients (1/12 after vaccination with peptide in AS02B and 12/17 after vaccination with peptide in IFA). The T cells produced IFN-gamma and downregulated CD45RA and CD28. T-cell responses correlated with inflammatory skin reactions at vaccine injection sites (P < 0.001) and with DTH reaction to Melan-A peptide (P < 0.01). Twenty-six of 32 evaluable patients showed progressive disease, whereas 4 patients had stable disease. The two patients with the strongest Melan-A-specific T-cell responses experienced regression of metastases in skin, lymph nodes, and lung. We conclude that repeated vaccination with Melan-A peptide in IFA frequently leads to sustained responses of specific CD8 T cells that are detectable ex vivo and correlate with inflammatory skin reactions.
Resumo:
In addition to the monographs which were published last year by the working group "Drug Monitoring" of the Swiss Society of Clinical Chemistry (SSCC) [1], new monographs have been written. The aim of these monographs is to give an overview of the most important information necessary for ordering a drug analysis or interpreting the results. Therefore, the targeted readers comprise laboratory health professionals and all receivers of laboratory reports. There is information provided on the indication for therapeutic drug monitoring, protein binding, metabolic pathways and enzymes involved, elimination half-life and elimination routes, and on therapeutic or toxic concentrations. Preanalytical considerations are of particular importance for therapeutic drug monitoring. Therefore, information is provided regarding a reasonable timing for the determination of drug concentrations as well as steady-state concentrations after changing the dose. Furthermore, the stability of the drug and its metabolite(s) after blood sampling is described. For readers with a specific interest in drug analysis, references to important publications are given. The number of monographs will be continuously enlarged. The updated files are presented on the homepage of the SSCC (www.sscc.ch).
Resumo:
OBJECTIVE: To compare three spin-echo sequences, transverse T1-weighted (T1WI), transverse fat-saturated (FS) T2-weighted (T2WI), and transverse gadolinium-enhanced (Gd) FS T1WI, for the visualisation of normal and abnormal finger A2 pulley with magnetic resonance (MR) imaging at 3 tesla (T). MATERIALS AND METHODS: Sixty-three fingers from 21 patients were consecutively investigated. Two musculoskeletal radiologists retrospectively compared all sequences to assess the visibility of normal and abnormal A2 pulleys and the presence of motion or ghost artefacts. RESULTS: Normal and abnormal A2 pulleys were visible in 94% (59/63) and 95% (60/63) on T1WI sequences, in 63% (40/63) and 60% (38/63) on FS T2WI sequences, and in 87% (55/63) and 73% (46/63) on Gd FS T1WI sequences when read by the first and second observer, respectively. Motion and ghost artefacts were higher on FS T2WI sequences. Seven among eight abnormal A2 pulleys were detected, and were best depicted with Gd FS T1WI sequences in 71% (5/7) and 86% (6/7) by the first and the second observer, respectively. CONCLUSION: In 3-T MRI, the comparison between transverse T1WI, FS T2WI, and Gd FS T1WI sequences shows that transverse T1WI allows excellent depiction of the A2 pulley, that FS T2WI suffers from a higher rate of motion and ghost artefacts, and transverse Gd FS T1WI is the best sequence for the depiction of abnormal A2 pulley.
Resumo:
The consumption of mineral waters is increasing in industrialised countries. High intakes of Ca and other alkalising cations as well as a low acid intake are beneficial to bone. We examined which components of mineral waters are conditioning their Ca content and their alkalinising power, in order to define the optimal profile. European mineral waters were randomly selected on the Internet: 100 waters with less than 200 mg Ca/l (9.98 mEq/l) and fifty with more than 200 mg/l, all with complete data for SO4, P, Cl, Na, K, Mg and Ca, and most also for HCO3. For comparison, forty North American mineral waters were randomly chosen. The potential renal acid load (PRAL) was calculated for each mineral water. North American waters did not reveal significant results because of their low mineralisation. We performed correlations between all eight components in order to explore the properties of the mineral waters. In the European waters, twenty-six out of twenty-eight correlations showed a P value of <or= 0.01. In waters with PRAL >0 (acidifying waters), PRAL was positively correlated with SO4, Ca, K and Mg (P < 0.001). In those with PRAL < 0 (alkalinising waters), PRAL was negatively correlated with HCO3, Na, Mg, Ca, K, Cl and SO4 (P < 0.001). SO4 and HCO3 were not found together in high quantities in the same water for geochemical reasons. A high Ca content is associated with either a high SO4 or a high HCO3 content. SO4 theoretically increases Ca excretion, while HCO3 and low PRAL values are associated with positive effects on bone. Therefore, the best waters for bone health are rich in both HCO3 and Ca, and by consequence low in SO4.