285 resultados para Metagenomic comparison of endemic viruses


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The importance of direct and indirect alcohol markers to evaluate alcohol consumption in clinical and forensic settings is increasingly recognized. While some markers are used to prove abstinence from ethanol, other markers are suitable for detection of alcohol misuse. Phosphatidyl ethanol (PEth) is ranked among the latter. There is only little information about the correlation between PEth and other currently used markers (ethyl glucuronide, ethyl sulfate, carbohydrate deficient transferrin, gamma-glutamyl transpeptidase, and methanol) and about their decline during detoxification. To get more information, 18 alcohol-dependent patients in withdrawal therapy were monitored for these parameters in blood and urine for up to 19 days. There was no correlation between the different markers. PEth showed a rapid decrease at the beginning of the intervention, a slow decline after the first few days, and could still be detected after 19 days of abstinence from ethanol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A questionnaire investigating adolescents' opinions and experiences regarding marijuana use was administered to 163 adolescents and young adults (96 boys and 67 girls) aged 13 to 20 (mean age = 16.8, s.d. = 1.5). Items referred to marijuana and other substances' dangerousness, representations regarding the positive and negative consequences of marijuana use. Responses were compared according to marijuana use status (classified into never/occasional use, current regular use and past regular use). Results show that adolescents' opinions differ according to their experience with marijuana use. Current regular users evaluate marijuana as less dangerous, but alcohol and heroin as more dangerous in comparison with never/occasional and past users. Current and past users are more likely to define marijuana as a medical drug and a plant used in agriculture, and less likely to define it as an illegal drug. Current and past users evaluate marijuana use as a way to cope with stress, to relax to a greater extent than do never/occasional users do. The latter attribute more negative consequences to marijuana use such as diminished driving ability and school performance and a pathway to hard drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to compare foot plantar pressure distribution while jogging and running in highly trained adolescent runners. Eleven participants performed two constant-velocity running trials either at jogging (11.2 ± 0.9 km/h) or running (17.8 ± 1.4 km/h) pace on a treadmill. Contact area (CA in cm(2)), maximum force (F(max) in N), peak pressure (PP in kPa), contact time (CT in ms), and relative load (force time integral in each individual region divided by the force time integral for the total plantar foot surface, in %) were measured in nine regions of the right foot using an in-shoe plantar pressure device. Under the whole foot, CA, F(max) and PP were lower in jogging than in running (-1.2% [p<0.05], -12.3% [p<0.001] and -15.1% [p<0.01] respectively) whereas CT was higher (+20.1%; p<0.001). Interestingly, we found an increase in relative load under the medial and central forefoot regions while jogging (+6.7% and +3.7%, respectively; [p<0.05]), while the relative load under the lesser toes (-8.4%; p<0.05) was reduced. In order to prevent overloading of the metatarsals in adolescent runners, excessive mileage at jogging pace should be avoided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three different short versions of the NEO-PI-R were compared: The NEO-FFI, the NEO-FFI-R, and a new short version developed in the current study (NEO-60). This new version is intended to improve the psychometric characteristics of the original NEO-FFI, specially in regard to the factor structure at the item-level. A French version of the NEO-PI-R was given to 1090 Swiss subjects, whereas the Spanish (Castilian) version of the NEO-PI-R was administered to 1006 Spanish subjects. Results replicate the limitations of the NEO-FFI already found in other countries. Compared to the NEO-FFI, reliability coefficients and factor structure was enhanced by the NEO-FFI-R and the NEO-60 in both samples, although substantial differences were not found. The factor structure of the NEO-60 shows the best fit since only three items do not load mainly on their own factor in both samples. Besides, correlations between items and NEO-PI-R domain scores are also higher for the items included in the NEO-60 version. On the other hand, convergent correlations with the NEO-PI-R dimensions were satisfactory irrespective of the version, and confirmatory factor analyses show slight differences among the different models generated after the three short versions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Previous literature has suggested that laws and regulations may impact the use of palliative sedation. Our present study compares the attitudes of French-speaking physicians practicing in the Quebec and Swiss environments, where different laws are in place regarding physician-assisted suicide. METHOD: Data were drawn from two prior studies, one by Blondeau and colleagues and another by Beauverd and coworkers, employing the same two-by-two experimental design with length of prognosis and type of suffering as independent variables. Both the effect of these variables and the effect of their interaction on Swiss and Quebec physicians' attitudes toward sedation were compared. The written comments of respondents were submitted to a qualitative content analysis and summarized in a comparative perspective. RESULTS: The analysis of variance showed that only the type of suffering had an effect on physicians' attitudes toward sedation. The results of the Wilcoxon test indicated that the attitudes of physicians from Quebec and Switzerland tended to be different for two vignettes: long-term prognosis with existential suffering (p = 0.0577) and short-term prognosis with physical suffering (p = 0.0914). In both cases, the Swiss physicians were less prone to palliative sedation. SIGNIFICANCE OF RESULTS: The attitudes of physicians from Quebec and Switzerland toward palliative sedation, particularly regarding prognosis and type of suffering, seem similar. However, the results suggest that physicians from Quebec could be slightly more open to palliative sedation, even though most were not in favor of this practice as an answer to end-of-life existential suffering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Despite the increasing incidences of the publication of assessment frameworks intending to establish the "standards" of the quality of qualitative research, the research conducted using such empirical methods are still facing difficulties in being published or recognised by funding agencies. Methods: We conducted a thematic content analysis of eight frameworks from psychology/psychiatry and general medicine. The frameworks and their criteria are then compared against each other. Findings: The results illustrated the difficulties in reaching consensus on the definition of quality criteria. This showed the differences between the frameworks from the point of views of the underlying epistemology and the criteria suggested. Discussion: The aforementioned differences reflect the diversity of paradigms implicitly referred to by the authors of the frameworks, although rarely explicitly mentioned in text. We conclude that the increase in qualitative research and publications has failed to overcome the difficulties in establishing shared criteria and the great heterogeneity of concepts raises methodological and epistemological problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To better define the concordance of visual loss in patients with nonarteritic anterior ischemic optic neuropathy (NAION). METHODS The medical records of 86 patients with bilateral sequential NAION were reviewed retrospectively, and visual function was assessed using visual acuity, Goldmann visual fields, color vision, and relative afferent papillary defect. A quantitative total visual field score and score per quadrant were analyzed for each eye using the numerical Goldmann visual field scoring method. RESULTS Outcome measures were visual acuity, visual field, color vision, and relative afferent papillary defect. A statistically significant correlation was found between fellow eyes for multiple parameters, including logMAR visual acuity (P = .01), global visual field (P < .001), superior visual field (P < .001), and inferior visual field (P < .001). The mean deviation of total (P < .001) and pattern (P < .001) deviation analyses was significantly less between fellow eyes than between first and second eyes of different patients. CONCLUSIONS Visual function between fellow eyes showed a fair to moderate correlation that was statistically significant. The pattern of vision loss was also more similar in fellow eyes than between eyes of different patients. These results may help allow better prediction of visual outcome for the second eye in patients with NAION.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results ( n=29) and patient's clinical evolution ( n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer ( p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Percutaneous closure of patent foramen ovale (PFO) has been proposed as the treatment of choice for young high-risk patients who suffered cryptogenic stroke and/or peripheral paradoxical embolism. We sought to compare prospectively two different devices used for percutaneous PFO closure.Prospective data were collected on 40 high risk patients (females: 38%, mean age : 44 +/- 11 years, interatrial septal aneurysm >10 mm: 68%) who underwent percutaneous PFO closure after cryptogenic stroke (n = 38) or peripheral paradoxical embolism (n = 2). Chronologically, 20 patients were first treated by a PFO-Star (Cardia, Burnsville, MI) device. Then, 20 other patients received a Starflex occluder (NMT, Boston, MA). The primary endpoint was complete PFO closure at 6 months as assessed by transthoracic contrast echocardiography. Secondary endpoints were major peri- or post procedural complications and clinical recurrence at 1 year follow-up.Baseline clinical and anatomical characteristics were comparable for both groups. Complete PFO closure was observed in 50% (PFO-Star) and 90% (Starflex) of patients (p=0.001) respectively. Major peri-procedural complications occurred in the PFO-star group only: right-sided device thrombus (1 patient) and aorto-right atrial fistula (1 patient). At 1 year follow-up, no clinical recurrence occurred.In conclusion, despite the absence of clinical recurrence in this high-risk population with presumed paradoxical embolism, complete PFO closure at 6 months follow-up was significantly related to the type of closure device used

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: While there is interest in measuring the satisfaction of patients discharged from psychiatric hospitals, it might be important to determine whether surveys of psychiatric patients should employ generic or psychiatry-specific instruments. The aim of this study was to compare two psychiatric-specific and one generic questionnaires assessing patients' satisfaction after a hospitalisation in a psychiatric hospital. METHODS: We randomised adult patients discharged from two Swiss psychiatric university hospitals between April and September 2004, to receive one of three instruments: the Saphora-Psy questionnaire, the Perceptions of Care survey questionnaire or the Picker Institute questionnaire for acute care hospitals. In addition to the comparison of response rates, completion time, mean number of missing items and mean ceiling effect, we targeted our comparison on patients and asked them to answer ten evaluation questions about the questionnaire they had just completed. RESULTS: 728 out of 1550 eligible patients (47%) participated in the study. Across questionnaires, response rates were similar (Saphora-Psy: 48.5%, Perceptions of Care: 49.9%, Picker: 43.4%; P = 0.08), average completion time was lowest for the Perceptions of Care questionnaire (minutes: Saphora-Psy: 17.7, Perceptions of Care: 13.7, Picker: 17.5; P = 0.005), the Saphora-Psy questionnaire had the largest mean proportion of missing responses (Saphora-Psy: 7.1%, Perceptions of Care: 2.8%, Picker: 4.0%; P < 0.001) and the Perceptions of Care questionnaire showed the highest ceiling effect (Saphora-Psy: 17.1%, Perceptions of Care: 41.9%, Picker: 36.3%; P < 0.001). There were no differences in the patients' evaluation of the questionnaires. CONCLUSION: Despite differences in the intended target population, content, lay-out and length of questionnaires, none appeared to be obviously better based on our comparison. All three presented advantages and drawbacks and could be used for the satisfaction evaluation of psychiatric inpatients. However, if comparison across medical services or hospitals is desired, using a generic questionnaire might be advantageous.